Laserfiche WebLink
1 FOUNDATION, SEE STRUCTURAL PLANS <br />2 3" CONCRETE DUST SLAB <br />3 FLOOR JOIST, SEE STRUCTURAL PLANS <br />4 PLYWOOD SUB-FLOOR, SEE STRUCTRUAL <br />5 FINISH FLOOR ASSEMBLY, SEE ARCHITECTUAL DETAILS <br />6 BATT INSULATION, SEE TITEL 24 <br />7 RIGID SPRAY ON INSULATION <br />8 5/8" TYPE "X" GYPSUM BOARD WITH VENEER PLASTER, SEE SPECIFICATIONS <br />9 SPECIALTY PLASTER FINISH, SEE SPECIFICATIONS <br />10 EXTERIOR CEMENT PLASTER (STUCCO), SEE SPECIFICATIONS <br />11 FIBER CEMENT PANELS <br />12 GUARDRAIL AT 42" ABOVE FINISH FLOOR <br />13 HANDRAIL AT 34" - 38" ABOVE FINISH FLOOR <br />14 CEILING JOIST, SEE STRUCTURAL PLANS <br />15 ROOF RAFTERS, SEE STRUCTURAL PLANS <br />16 ROOF SHEATHING, SEE STRUCTURAL PLANS <br />17 CLASS "A" ROOFING ASSEMBLY, SEE ROOF PLAN FOR SPECIFICATIONS <br />18 BELOW GRADE WATERPROOFING, SEE DETAILS AND SPECIFICATIONS <br />SECTION KEY NOTES <br />BUILDING SECTION NOTES <br />CONTRACTOR TO FIELD VERIFY BUILDING HEIGHTS AND THE ALLOWABLE <br />BUILDING ENVELOPE. INFORM ARCHITECT OF ANY DISCREPANCIES <br />A. <br />CONTRACTOR TO FIELD VERIFY BUILDING HEIGHTS AND THE ALLOWABLE <br />BUILDING ENVELOPE. INFORM ARCHITECT OF ANY DISCREPANCIES <br />B. <br />PROVIDE A CONTINUOUS METAL WEEP SCREED AS REQUIRED BY CODE SECTION <br />R703.6.2.1, SEE DETAILS <br />C. <br />AT MECHANICALLY ATTACHED STONE AND BRICK, PROVIDE FLASHING AND <br />MINIMUM 3/8" DIA. WEEP HOLES AT 30" MIN. O.C. AS REQUIRED PER SEC R703.7.2 <br />D. <br />STONE INSTALLATION SYSTEM SHALL BE REVIEWED AND APPROVED BY THE <br />STRUCTURAL ENGINEER PRIOR TO INSTALLATION <br />E. <br />CONTRACTOR SHALL PROVIDE MOCK-UPS OF ALL EXTERIOR FINISHES AND <br />ASSEMBLIES FOR OWNER'S AND ARCHITECT'S REVIEW AND APPROVAL <br />F. <br />ALL EXTERIOR STUDS SHALL BE 2X8 FRAMING OR MULTIPLE ROWS OF 2X6 <br />FRAMING UNLESS OTHERWISE NOTED. ALL INTERIOR WALLS SHALL BE 2X6 <br />FRAMING UNLESS OTHERWISE NOTED. SPACING AND SPECIFICATION ARE PER <br />STRUCTURAL <br />G <br />PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON ALL GARAGE WALLS, CEILING, POSTS, <br />AND SUPPORTING BEAMS AND SHALL EXTEND FROM TOP OF CONCRETE TO AND <br />INCLUDING THE CEILING <br />H <br />PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS IN ENCLOSED <br />USEABLE SPACE UNDER STAIRS <br />I <br />STRUCTURE SHALL COMPLY TO LOCAL GOVERNING HIGH FIRE HAZARD SEVERITY <br />ZONE AS REQUIRED <br />J <br />FIRE BLOCKING SHALL BE PROVIDED IN WOOD-FRAMED CONSTRUCTION IN THE <br />FOLLOWING LOCATIONS: <br />K <br />a. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, <br />INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS, <br />VERTICALLY AT THE CEILING AND FLOOR LEVELS HORIZONTALLY AT <br />INTERVALS NOT EXCEEDING 10 FEET <br />b. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND <br />HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, <br />AND COVE CEILINGS <br />c. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP <br />AND BOTTOM OF THE RUN <br />d. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, AND WIRES <br />AT CEILING AND FLOOR LEVELINSULATION: PROVIDE R-19 MIN. AT ALL EXTERIOR WALLS, INCLUDING GARAGE. <br />PROVIDE R-30 INSULATION IN ATTIC SPACES. PROVIDE R-19 INSULATION AT ALL <br />INTERIOR WALLS. PROVIDE R-30 INSULATION AT ALL FLOOR FRAMING. SEE TITLE <br />24 FOR ADDITIONAL REQUIREMENTS. PROVIDE INSULATION AROUND PLUMBING <br />PIPES AND HVAC DUCTS, SEE MECHANICAL AND PLUMBING PLANS FOR <br />ADDITIONAL REQUIREMENTS <br />L <br />ATTIC INSULATION SHALL HAVE A VAPOR BARRIER WITH A TRANSMISSION RATE <br />NOT EXCEEDING 1 PERM IN ACCORDANCE WITH ASTM E96 INSTALLED ON THE <br />WARM SIDE OF THE ATTIC INULSATION <br />M <br />AN APPROVED WEATHERPROOFING CONSULTANT MUST CERTIFY THE <br />WEATHERPROOFING ELEMENTS OF THE BUILDING HAVE BEEN INSTALLED IN <br />ACCORDANCE WITH THE APPROVED PLANS AS REQUIRED BY LOCAL CODES AND <br />PER MANUFACTURER'S RECOMMENDATIONS <br />N <br />CONTRACTOR SHALL VERIFY WITH MECHANICAL. ELECTRICAL, AND PLUMBING <br />PLANS ALL LOCATIONS OF MECHANICAL UNITS, DUCTS, REGISTERS, ELECTRICAL <br />PANELS, ACCESS TO PLUMBING FIXTURES, ETC. <br />OLEVEL 1 SUB <br />(N) T.O. PLATE <br />LEVEL 2 SUB <br />1 <br />A-6.1 <br />8' - 0 1/2" <br />BEDROOM 1 <br />104 <br />LIVING / <br />KITCHEN <br />102 <br />6 <br />FINISH GRADE <br />7 <br />5 <br />1 <br />PROVIDE MIN <br />1HR/ STC 50 <br />RATING <br />LEVEL 1 SUB <br />(N) T.O. PLATE <br />LEVEL 2 SUB <br />2 <br />A-6.1 <br />LIVING / <br />KITCHEN <br />102 <br />BATHROOM <br />103 <br />6 <br />5 <br />14 <br />7 <br />8' - 0 1/2" <br />FINISH GRADE <br />1 <br />PROVIDE MIN <br />1HR/ STC 50 <br />RATING <br />A <br /> <br />R <br /> <br /> <br />C <br /> <br /> <br />H <br /> <br /> <br />I <br /> <br /> <br />T <br /> <br /> <br />E <br /> <br /> <br />C <br /> <br /> <br />T <br /> <br /> <br />U <br /> <br /> <br />R <br /> <br /> <br />E <br />D <br /> <br />I <br /> <br /> <br />A <br /> <br /> <br />L <br /> <br /> <br />E <br /> <br /> <br />C <br /> <br /> <br />T <br /> <br /> <br />I <br /> <br /> <br />C <br /> <br />80 <br />1 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />9 <br />1 <br />7 <br /> <br />| <br /> <br />L <br />O <br />S <br /> <br />A <br />N <br />G <br />E <br />L <br />E <br />S <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />0 <br />0 <br />1 <br />7 <br />62 <br />6 <br />. <br />3 <br />7 <br />5 <br />. <br />2 <br />8 <br />7 <br />3 <br /> <br />| <br /> <br />W <br />W <br />W <br />. <br />D <br />I <br />A <br />L <br />E <br />C <br />T <br />I <br />C <br />A <br />R <br />C <br />H <br />. <br />C <br />O <br />M <br /> <br />| <br /> <br /> <br />D <br />I <br />A <br />L <br />E <br />C <br />T <br />I <br />C <br />A <br />R <br />C <br />H <br />@ <br />G <br />M <br />A <br />I <br />L <br />. <br />C <br />O <br />M <br />REVISIONS <br />ISSUE DATE: <br />PROJECT #: <br />DRAWN BY: <br />CHECKED BY: <br />SCALE: <br />DIGITAL STAMP <br />As indicated <br />PI <br />N <br />E <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br /> <br />A <br />D <br />U <br /> <br />2 <br />A-6.1 <br />SECTIONS <br />Checker <br />2401.00 <br />VF <br />03.12.2025 <br />PERMIT SET <br />42 <br />3 <br /> <br />E <br /> <br />P <br />I <br />N <br />E <br /> <br />S <br />T <br /> <br />& <br /> <br />4 <br />2 <br />3 <br /> <br />P <br />I <br />N <br />E <br /> <br />S <br />T <br />. <br /> <br />UN <br />I <br />T <br /> <br /># <br />E <br /> <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />SCALE: 1/4" = 1'-0"CROSS SECTION 2 <br />SCALE: 1/4" = 1'-0"LONG SECTION 1