8" MAX.
<br />PERIMETER SEISMIC CLIP
<br />ANGLE MOLDING EDGE TRIM
<br />SCREWED TO EACH STUDCROSS TEE
<br /><10'-0" : TWO 1-5/8" (25GA) METAL STUD
<br /><15'-0" : TWO 2-1/2" (25GA) METAL STUD
<br /><20'-0" : TWO 3-5/8" (25GA) METAL STUD
<br />STUD
<br />ORIENTATION
<br />Specifications:
<br />Ceiling grid
<br />classification: Heavy-Duty
<br />Manufacturer's
<br />catalog number
<br />Main runner:
<br />Cross runner:
<br />Runner splice:
<br />Armstrong
<br />Prelude XL15__
<br />16
<br />"
<br />7301
<br />7340
<br />Armstrong
<br />Suprafine XL 9__
<br />16
<br />"
<br />7501
<br />7540
<br />USG DONN
<br />DX/DXT 15__
<br />16
<br />"
<br />ZXLA26
<br />ZXLA424
<br />TFS-1
<br />USG DONN
<br />DX/DXT 9__
<br />16
<br />"
<br />DXT26
<br />DXT424
<br />TFS-1
<br />SUSPENDED CEILING NOTES (INSTALLATION REQUIREMENTS): COMPLY WITH CBC 2501A.5 AND ASCE 7
<br />Fixture Attachment: Attach all light fixtures and
<br />ceiling mounetd air terminals to the ceiling grid
<br />runnders to resist a horizontal force equal to the
<br />weight of the fixtures. Screws or approved fasteners
<br />are requried.
<br />Flush or recessed light fixtures and air terminals
<br />weighing less than 56 lbs. may be supported directly
<br />on the runners of a heavy duty grid system, but in
<br />addition, must have a minimum of (2) #12 ga. slack
<br />safety wires attached to the fixture at diagonal
<br />corners and anchored to the structure above. All 4'x4'
<br />fixtures must have slack safety sires at each corner.
<br />All flush or recessed light fixtures and air terminals
<br />weighing 56 lbs. or more must be independently
<br />supported by not less than (4) taut #12 ga. wires,
<br />each attached to the fixture and to the structure
<br />above regardless of the type of grid system used.
<br />Surface Mounted Light Fixtures: Support surface
<br />mounted light fixtures by at least two positive devices
<br />which surround the ceiling runner and which are
<br />each supported from the structure ababove by a #12
<br />ga. wire. Spring clips or clamps that connect only to
<br />the runner are not acceptable. Provide additional
<br />supports when light fixtures are 8 feet or longer.
<br />Pendant Mounted Light Fixtures: Support pendant
<br />mounted light fixtures directly from the structure
<br />wabove with hanger wires or cables passing through
<br />each pendant hanger and capable of supporting (4)
<br />times the weight of the fixture. A bracing assembly is
<br />required where the pendant hanger penetrates the
<br />ceiling.
<br />Free Wall: at the perimeter of the ceiling area where main or
<br />cross runners are not connected to the adjacent wall, provide
<br />interconnection between the runners at the free end to prevent
<br />lateral spreading. A metal strut or a #16 ga. wire with a
<br />mechanical connection to the runner may be used. Where the
<br />perpendicular distance fromt he wall to the first parallel runner
<br />is 12" or less, this interlock is not requried.
<br />Seismic Bracing: Provide bracing assemblies consisting of a
<br />compression strut and (4) #12 ga. splayed bracing wires
<br />oriented 90 degress from each other at 12' x 12' on center, 6'
<br />maximum from each perimeter wall and at the edge of vertical
<br />ceiling offsets. Ceiling areas of 144 SF. or less, surrounded by
<br />walls which connect directly to the structure above, do not
<br />require bracing assemblies when attached to two adjacent
<br />walls.
<br />Fastening: Fasten hanger wires with not less than (3) tight
<br />turns. Fasten bracing wires with (4) tight turns. Make all tight
<br />turns within a distance of 1 1/2". Hanger or bracing wire
<br />anchors to the structure should be installed i nsuch a manner
<br />that the direction of the anchor aligns as closely as possible
<br />with the direction of the wire.
<br />Separation: Separate all ceilign hanger and bracing wires at
<br />least 6: from all unbraced ducts, pipes, conduit, etc.,
<br />Field Tests: Whe drilled-in concrete anchors or shot-in
<br />anchors are used in reinforced concrete for hanger wires, 1
<br />out of 10 must be field tested for 200 lbs. in tension. When
<br />drilled-in anchors are used for bracing wires, 1 out of 2 must
<br />be field tested for 400 lbs. in tension. Shot-in anchors for
<br />concrete are not permited for bracing wires.
<br />Hanger Wires: #12 ga. wires may be used for up to and including 4 ft. by 4 ft.
<br />grid spacing and shall be attached to main runners.
<br />Perimeter: Provide #12 ga. hanger wires at the ends of all main and cross
<br />runners within 8" of the support or within 1/4 th of the length of the end tee,
<br />whichever is least, for the perimeter of the ceiling area.
<br />Obstructions: Provide trapeze or other supplementary support members at
<br />ovstructions to gypical hanger spacing. Provide additional hangers, or braces as
<br />requried at all ceiling breakes, soffits or discontinuous areas. Hanger wires that
<br />are more than 1 in 6 out of plumb are to have counter-sloping wires.
<br />Wall Attachment: Ceiling grid members may be attached to not more than 2
<br />adjacent walls. Ceiling grid members shall be at least 1/2" clear of other walls. If
<br />walls run diagonally to ceiling grid system runenrs, one end of main and cross
<br />members should be free, and a minimum of 1/2" clear of wall.
<br />WHERE THE DISTANCE BETWEEN THE CEILING GRID
<br />AND THE SLAB ABOVE IS LESS THAN 8'-0": PROVIDE
<br />3-5/8" (25 GA.) METAL STUD. ATTACH TO MAIN
<br />RUNNERS WITH 2" OF FROSS RUNNER WITH (2) #12
<br />SELF-DRILLING, SELF-TAPPING SCREWS AND TO
<br />CONCRETE/ STEEL STRUCTURE WITH 3/16" DIA.
<br />ANCHOR.
<br />IF DISTANCE BETWEEN CEILNIG GRID AND SLAB
<br />ABOVE IS 8'-0" OR GREATER: USE THE SCHEDULE
<br />BELOW FOR STUD SIZES:
<br />METAL STUDS ORIENTED AS SHOWN, CONNECTED EVERY
<br />12" ALONG THEIR LENGTH
<br />COMPRESSION STRUT AT 12' O.C. BOTH
<br />DIRECTIONS
<br />12" GA. HANGER WIRES AT 48" O.C. ALONG MAIN
<br />TEE RUNNERS
<br />(4) 12 GA. SPLAYED SEISMIC BRACING
<br />WIRES AT 12' O.C. BOTH DIRECTIONS
<br />.
<br />45 DEGREE MAX.
<br />MAIN TEE RUNNER
<br />2" MAX.
<br />CROSS TEE RUNNER
<br />AT STEEL BEAM
<br />VERTICAL
<br />HANGER
<br />AT CONCRETE
<br />SPLAYED SEISMIC
<br />BRACING
<br />AT CONCRETE
<br />STEEL BEAM
<br />(SEE TYPICAL NOTES)
<br />#9 VERTICAL HANGER
<br />WIRE (200# TEST) w/ (3)
<br />TIGHT TURNS MIN.
<br />WOOD JOIST/BEAM
<br />CEILING CLIP, 13GA. x 3/4"
<br />MIN. - HILTI CC-27
<br />(ESR-2184) OR EQUAL
<br />1/4"" DIA. THREADED WOOD
<br />SCREW w/ 1 1/4" MIN.
<br />EMBEDMENT
<br />45°#12 SPLAYED SEISMIC
<br />WIRE (440# TEST) w/ (4)
<br />TIGHT TURNS MIN.
<br />STEEL STRAP, 1" WIDE x
<br />2" LONG x 12GA. MIN.
<br />WOOD JOIST/ BEAM
<br />1/4" DIA. THREADED WOOD
<br />SCREW w/ 1 1/4" MIN.
<br />EMBEDMENT
<br />5/8" MAX.
<br />5/8" MAX.
<br />B CARPET TO CERAMIC TILE
<br />CARPET TO RESILIENTA
<br />CARPET
<br />ALUM. TRANSITION STRIP
<br />VCT OR SHEET VINYL
<br />CONCRETE FLOOR
<br />SLAB W/ CLEAR SEALER
<br />D VCT TO CONCRETE
<br />VCT TO CERAMIC TILEC
<br />1/
<br />4
<br />"
<br />1/
<br />2
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />VCT
<br />THREASHOLD
<br />CERAMIC TILE
<br />CONCRETE FLOOR
<br />SLAB W/ CLEAR
<br />SEALER
<br />CARPET CLEAR ANODIZED ALUMINUM
<br />STRIP, SECURE TO SLAB
<br />CERAMIC TILE
<br />CLEAVAGE
<br />MEMBRANE OVER
<br />CONC. SLAB
<br />EPOXY GROUT, TAPER
<br />UP TO MEET CERAMIC
<br />TILE FINISH (IF
<br />REQUIRED)
<br />1/
<br />2
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />1/
<br />2
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />THRESHOLD VCT
<br />CONC. FLOOR
<br />SLAB W/ CLEAR
<br />SEALER
<br />METAL STUD FRAMING.
<br />SEE PARTITION PLAN
<br />5/8" TYPE 'X' GYP. BOARD
<br />SEMI-RECESSED FIRE EXTINGUISHER CABINET-
<br />SEE PARTITION PLAN LEGEND FOR SPEC. SEE
<br />PARTITION PLAN FOR LOCATIONS. CABINET
<br />FINISH TO BE PAINTED TO MATCH ADJACENT
<br />SURFACE, UNO.
<br />FACE OF WALL BEYOND
<br />5/8" TYPE 'X' GYP. BOARDA.
<br />F
<br />.
<br />F
<br />.
<br />
<br />T
<br />O
<br />
<br />K
<br />N
<br />O
<br />B
<br />.
<br />40
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />8"
<br />
<br />M
<br />I
<br />N
<br />.
<br />EXISTING CONC. WALL PANEL
<br />CONT. SEALANT BEAD
<br />TWO PIECE GALV. MTL. REGLET
<br />CAP SHEET
<br />FLASHING SHEETS
<br />CANT
<br />BUILT-UP ROOFING
<br />1/4" DENS DECK PROTECTION BOARD
<br />6" POLYISOCYANURATE RIGID
<br />INSULATION BOARDS (R-30 MIN.)
<br />EXISTING ROOF SUBSTRATE
<br />1. ASPHALT AND MBR UTILITY CEMENT NOT SHOWN FOR CLARITY
<br />2. LEAD FLASHING SHALL BE 2.5 LBS. PER SQUARE FOOT MINIMUM.
<br />3. IT IS ACCEPTABLE TO RUN FIELD MEMBRANE PLY THROUGH DRAIN CENTER AND OMIT
<br />TARGET SHEET IF DRAIN SUMP IS SHALLOW ENOUGH TO ALLOW INSTALLATION WITHOUT
<br />WRINKLES OR FISHMOUTHS. STEEP SUMPS WILL REQUIRE THE INSTALLATION OF A TARGET
<br />PATCH WITHIN DRAINSUMP.
<br />4. USE ASPHALT PRIMER ON LEAD FLANGES WHEN USING MBR UTILITY CEMENT. USE
<br />PERMAFLASH PRIMER ON LEAD FLANGES WHEN USING MBR FLASHING CEMENT.
<br />5. EXTEND ALL PLIES TO EDGE OF DRAIN BOWL. NO SEAMS ARE ALLOWED THROUGH THE DRAIN.
<br />SHEET LEAD, MIN. 30" x 30" PRIME
<br />LEAD WITH PRIMER ON BOTH
<br />SIDES, (SEE NOTES) ROLL LEAD
<br />DOWN BOWL. (SET IN MBR UTILITY
<br />CEMENT OR MBR FLASHING
<br />CEMENT)
<br />CLAMPING RING
<br />DRAIN STRAINER
<br />SUMP CORNER
<br />CAP SHEET UNDER
<br />CLAMPING RING
<br />BACKER PLY
<br />4" MIN.
<br />4" MIN.
<br />SMOOTH
<br />SURFACE PLY
<br />BELOW CAP
<br />SHEET
<br />INSULATION TAPERED
<br />TO DRAIN
<br />UNDERDECK DRAIN
<br />CLAMP (AS REQUIRED)
<br />LEAD SHEET
<br />RIGID INSULATIONNOTES:
<br />6. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND
<br />CONSTRUCTED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS AND/OR PROJECT
<br />SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED BY A LICENSED
<br />DESIGN PROFESSIONAL.
<br />7. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF
<br />INSTALLATION INSTRUCTIONS AND REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS
<br />DETAIL.
<br />CAP SHEET
<br />ROOF ASSEMBLY
<br />SEALANT
<br />SURFACED FLASHING PLY (SEE NOTE 5.)
<br />DRAWBAND
<br />FLASHING COLLAR (8" TALL MIN.)
<br />STORM COLLAR (INJECT POLYURETHANE
<br />SEALANT BETWEEN COLLAR AND PIPE. TIGHTEN
<br />DRAWBAND AND TOOL SEALANT BLEEDOUT
<br />AROUND PIPE.)
<br />FLASHING PLIES (INSTALL MIN. TWO (2)
<br />FLASHING PLIES, AND FEATHER EACH
<br />PLY 3" MIN.)
<br />BITUMINOUS ROOF CEMENT OR
<br />POLYUREHANE SEALANT (INSTALL
<br />AT BASE OF PENETRATION.)
<br />FLASHING COLLAR FLANGE (PRIME BOTH
<br />SIDES OF HORIZONTAL FLANGES AND SET
<br />IN BED OF BITUMOUS ROOF CEMENT ON
<br />FINISHED FIELD PLIES. IF REQUIRED, NAIL
<br />TO DECK APPROX 3" O.C. STAGGERED.)
<br />MULTIPLE-PLY POLYMER MODIFIED
<br />BITUMEN ROOFING FIELD PLIES
<br />BASE SHEET (MECHANICALLY
<br />ATTACH AS REQUIRED.)
<br />PIPE PENETRATION
<br />SECURED TO
<br />STRUCTURAL FRAMING
<br />FIRE SAFING INSULATION
<br />REQUIRED AT HOT
<br />STACK CONDITION
<br />1. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE APPROXIMATE TO ALLOW FOR RESONABLE
<br />TOLERANCES DUE TO FIELD CONDITIONS.
<br />2. THIS DETAIL IS SUITABLE FOR FLASHING ROUND PIPES USED TO SUPPORT EQUIPMENT, ELECTRICAL CONDUIT,
<br />WATER AND GASE LINES, SHEET METAL FLUES, AND OTHER SIMILAR PENETRATIONS.
<br />3. THE HORIZONTAL FLASHING FLANGES TO BE A MINIMUM OF 4" WIDE.
<br />4. SET METAL FLASHING FLANGES ON FINISHED FIELD PLIES AND STRIP-IN BEFORE SURFACING.
<br />5. SURFACED FLASHING PLY IS RECOMMENDED TO HAVE WHITE OR OTHER LIGHT REFLECTING SURFACE TO
<br />MINIMIZE HEAT GAIN AND THERMAL MOVEMENT. FOR AGGREGATE-SURFACE MEMBRANES, EXTEND AGGREGATE
<br />COVERAGE TO OUTSIDE OF COLLAR.
<br />ROOF ASSEMBLY
<br />COUNTERFLASHING
<br />SKIRT (SEE NOTE 2.)
<br />3" MIN.
<br />3" MIN.
<br />SURFACED
<br />FLASHING PLY
<br />(SEE NOTE 3.)
<br />SHEET METAL
<br />COUNTERFLASHING
<br />GASKETED SCREW
<br />FASTENERS
<br />BASE FLASHING MEMBRANE
<br />(EXTEND TO TOP OF CURB AND
<br />FASTEN 6" O.C. EXTEND ONTO
<br />ROOF SURFACE BEYOND TOE
<br />OF CANT.)
<br />MULTIPLE-PLY POLYMER MODIFIED
<br />BITUMEN ROOFING (OPTION: FIELD
<br />PLIES MAY BE EXTENDED OR
<br />FEATHERED ABOVE HEAD OF CANT.)
<br />BASE SHEET
<br />(MECHANICALLY ATTACH
<br />AS REQUIRED.)
<br />FIBER CANT STRIP (SET FIBER
<br />CANT IN HOT ASPHALT OR
<br />BITUMOUS ROOF CEMENT
<br />OVER BASE SHEET.)
<br />PRE-FABRICATED 18 GA. GALV.
<br />EQUIPMENT CURB 8" HIGH MIN.
<br />W/ FACTORY WOOD NAILER AT
<br />TOP, PRESERVATIVE TREATED,
<br />AND RIGID INSULATION
<br />NOTES:
<br />1. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE
<br />APPROXIMATE AND TO ALLOW FOR REASONABLE TOLERANCES DUE TO
<br />FIELD CONDITIONS.
<br />2. COUNTERFLASHING SKIRT IS RECOMMENDED WHEN PRE-
<br />MANUFACTGURED FLASHING FLANGE EXTENDS LESS THAN 2" OVER
<br />MEMBRANE BASE FLASHING, OR WHEN BASE FLASHING FASTENERS ARE
<br />EXPOSED.
<br />3. SURFACED FLASHING PLY IS RECOMMENDED TO HAVE WHITE OR OTHER
<br />LIGHT REFLECTING SURFACE TO MINIMIZE HEAT GAIN AND THERMAL
<br />MOVEMENT.
<br />DETAIL VIEW
<br />Approx.
<br />6" O.C.
<br />ROOF DECK
<br />SHEET METAL CAP
<br />3" MIN.3" MIN.
<br />SURFACED FLASHING PLY
<br />(SEE NOTE 4.)
<br />MEMBRANE BASE
<br />FLASHING (FASTEN TO
<br />TOP OF CURB AT
<br />APPROX. 6" O.C. EXTEND
<br />ONTO FIELD OF ROOF
<br />BEYOND TOE OF CANT.)
<br />MULTIPLE-PLY POLYMER MODIFIED BITUMEN
<br />ROOFING (OPTION: FIELD PLIES MAY BE
<br />EXTENDED OR FEATHERED ABOVE HEAD OF
<br />CANT.)
<br />BASE SHEET (MECHANICALLY
<br />ATTACH AS REQUIRED.)
<br />FIBER CANT, SET CANT OVER
<br />BASE SHEET IN HOT ASPHALT
<br />OR BITUMOUS ROOF CEMENT
<br />WOOD CURB (EXTEND 8"
<br />MIN. ABOVE FINISHED ROOF
<br />SURFACE. PRESERVATIVE
<br />TREATMENT OPTIONAL.)
<br />Notes:
<br />1. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE APPROXIMATE TO
<br />ALLOW FOR REASONABLE TOLERANCES DUE TO FIELD CONDITIONS.
<br />2. ATTACH TOP OF MEMBRANE BASE FLASHING APPROXIMATELY 6" O.C.
<br />3. SURFACE FLASHING PLY IS RECOMMENDED TO HAVE WHITE OR OTHER LIGHT
<br />REFLECTING SURFACE TO MINIMIZE HEAT GAIN AND THERMAL MOVEMENT.
<br />HIGH-DOMED CAPPED, GASKETED SELF-
<br />TAPPING SCREW (FASTEN AT
<br />APPROXIMATELY 18" O.C.)MEMBRANE BASE
<br />FLASHING (LAP AT TOP
<br />FOR DOUBLE LAYER.)
<br />HHENDY.COM
<br />T (949) 851-3080
<br />4770 Campus Dr., Suite 100
<br />Newport Beach, CA 92660
<br />H ndy
<br />ISSUES AND REVISIONS
<br />JOB NUMBER
<br />SCALE
<br />PROJECT
<br />TEAM
<br />All specifications, drawings, concepts, designs, arrangements, intellectual and written material represented herein constitute
<br />unique and unpublished work of H. Hendy Associates and may not be copied, used by or disclosed to others without written
<br />consent of H. Hendy Associates.
<br /> 2023 H.HendyAssociatesc
<br />DATE
<br />As indicated
<br />04463.0000.24
<br />3080 S. HARBOR BLVD.
<br />SANTA ANA, CA 92704
<br />DETAILS
<br />IA-7.1
<br />MCGUFF
<br />AB/CD
<br />SCALE
<br />3" = 1'-0"2PERIMETER TRIM
<br />SCALE
<br />12" = 1'-0"3ACCOUSTICAL CEILING SUSPENSION SYSTEM
<br />SCALE
<br />3" = 1'-0"4SUSPENDED CEILING ATTACHMENT POINTS
<br />SCALE
<br />6" = 1'-0"9FLOORING TRANSITIONS
<br />SCALE
<br />1 1/2" = 1'-0"10FIRE EXTINGUISHER CABINET
<br />SCALE
<br />1 1/2" = 1'-0"16ROOF AT PARAPET
<br />SCALE
<br />1 1/2" = 1'-0"14ROOF AT DRAIN
<br />SCALE
<br />3" = 1'-0"13B.U.R. PIPE PENETRATION
<br />SCALE
<br />3" = 1'-0"19CURB FLASHING
<br />SCALE
<br />1 1/2" = 1'-0"17SLEEPER FLASHING
<br />NO. DESCRIPTION DATE
<br />PLAN CHECK SUBMITTAL 3/17/25
|