My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3080 S Harbor Blvd - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Harbor Blvd
>
3080 S Harbor Blvd
>
3080 S Harbor Blvd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:08 AM
Creation date
2/13/2026 5:00:37 AM
Metadata
Fields
Template:
Plan
Permit Number
101123703
101123704
Full Address
3080 S Harbor Blvd
Street Number
3080
Street Direction
S
Street Name
Harbor
Street Suffix
Blvd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DOOR TYPE ELEVATIONS <br />A B C <br />- <br />11 <br />- <br />15 <br />- <br />11 <br />- <br />15 <br />NOT USED <br />NOT USED <br />3' <br /> <br />- <br /> <br />0 <br />" <br />- <br />17 <br />- <br />17 <br />D <br />GROUP H1 (CARD READER ENTRY, SINGLE DOOR) <br />ELECTRIC LOCKSET:BY TENANT VENDOR <br />ELECTRIC HINGE:BY TENANT VENDOR <br />BALL BEARING HINGE:HAGER BB 4-1/2" X 4-1/2" <br />CLOSER: NORTON 1600 SERIES <br />DOOR STOP:QUALITY 331 <br />GROUP H2 (KEYED ENTRY, SINGLE DOOR) <br />ENTRY LOCKSET:BUILDING STANDARD <br />BALL BEARING HINGE:HAGER BB 4-1/2" X 4-1/2" <br />CLOSER: NORTON 1600 SERIES <br />DOOR STOP:QUALITY 331 <br />GROUP H3 (OFFICE) <br />OFFICE LOCKSET SCHLAGE L SERIES, LEVER <br />STANDARD HINGE:HAGER 4-1/2" X 4-1/2" <br />DOOR STOP:QUALITY 331 <br />GROUP H4 (PASSAGE) <br />PASSAGE LATCHSET:SCHLAGE L SERIES, LEVER <br />BALL BEARING HINGE:HAGER BB 4-1/2" X 4-1/2" <br />CLOSER: NORTON 1600 SERIES <br />DOOR STOP:QUALITY 331 <br />GROUP H5 (STORAGE) <br />STOREROOM LOCKSET:SCHLAGE L SERIES, LEVER <br />BALL BEARING HINGE:HAGER BB 4-1/2" X 4-1/2" <br />CLOSER:NORTON 1600 SERIES <br />DOOR STOP:QUALITY 331 <br />HARDWARE SCHEDULE <br />GROUP H6 (PRIVACY) <br />PRIVACY LOCKSET:SCHLAGE L SERIES, LEVER <br />BALL BEARING HINGE:HAGER BB 4-1/2" X 4-1/2" <br />CLOSER:NORTON 1600 SERIES <br />DOOR STOP:QUALITY 331 <br />WALL TYPE PER PLAN <br />METAL TRACK <br />DOUBLE METAL STUD HEADER <br />CONTINUOUS SEALANT -BOTH SIDES <br />HOLLOW METAL DOOR FRAME <br />DOOR -REFER TO DOOR SCHEDULE <br />HEAD <br />FRAME ANCHOR -3 PER JAMB <br />DOOR -REFER TO DOOR SCHEDULE <br />HOLLOW METAL DOOR FRAME <br />CONTINUOUS SEALANT -BOTH SIDES <br />WALL TYPE PER PLAN <br />DOUBLE STUDS AT JAMB <br />VA <br />R <br />I <br />E <br />S <br /> <br />P <br />E <br />R <br /> <br />W <br />A <br />L <br />L <br /> <br />T <br />Y <br />P <br />E <br />JAMB <br />STEEL STUD ANCHORSBASE CLIPS <br />2" <br />VERIFY <br />VE <br />R <br />I <br />F <br />Y <br />2" <br />RETAINER CLIP <br />DOOR -REFER TO SCHEDULE <br />VA <br />R <br />I <br />E <br />S <br /> <br />P <br />E <br />R <br /> <br />W <br />A <br />L <br />L <br /> <br />T <br />Y <br />P <br />E <br />VE <br />R <br />I <br />F <br />Y <br />STEEL KNOCK-DOWN FRAME <br />DOUBLE STUDS AT JAMB <br />WALL TYPE PER PLAN <br />VERIFY <br />DOOR -REFER TO SCHEDULE <br />STEEL KNOCK-DOWN FRAME <br />DOUBLE METAL STUD HEADER <br />METAL TRACK <br />WALL TYPE PER PLAN <br />HEAD <br />JAMB <br />39 <br />" <br />>1/2 W <br />W <br />>1/2 W <br />39 <br />" <br />W <br />>1/2W <br />NOTES: <br />1. 15 LBS <br />2. LENGTH OF PUSH PAD SHALL BE GREATER THAN HALF OF <br />THE WIDTH OF THE ACTIVE DOOR LEAF <br />3/4" CONDUIT STUBBED <br />INTO ACCESSIBLE CEILING SPACE <br />SINGLE <br />CARD READER ON J-BOX <br />ELECTRIFIED MORTISE LOCK <br />3/4" C. <br />DOOR CONTACTS <br />WIRE PATHWAY IN DOOR <br />TERMINATE CONDUIT IN <br />DOOR FRAME ADJACENT <br />TO ELECTRIC HINGE <br />REQUEST TO EXIT INFRARED <br />SENSOR MOUNTED ON J-BOX <br />(ON OPPOSITE FACE OF WALL) <br />1/2" C. <br />1/2" C. <br />TERMINATE CONDUIT IN <br />DOOR FRAME <br />ADJACENT <br />TO ELECTRIC HINGE <br />WIRE PATHWAY IN DOOR <br />PAIR <br />CARD READER ON J-BOX <br />ELECTRIFIED MORTISE <br />LOCK <br />REQUEST TO EXIT INFRARED <br />SENSOR MOUNTED ON J-BOX <br />(ON OPPOSITE FACE OF <br />WALL) <br />3/4" CONDUIT STUBBED <br />INTO ACCESSIBLE CEILING <br />SPACE <br />1/2" C. <br />1/2 <br />" <br />C. <br />3/4" C. <br />DOOR CONTACTS <br />A <br />B <br />AT THIN-SET TILE <br />AT MORTAR BED TILE <br />2 <br />11/ <br />4 <br />" <br />1/ <br />4 <br />" <br />2 <br />1 <br />1/ <br />4 <br />" <br />1/ <br />4 <br />" <br />ADJACENT FLOOR <br />ADJACENT FLOOR <br />MARBLE THRESHOLD W/ POLISHED <br />FINISH -FULL DEPTH OF DOOR <br />FRAME. NOTCH AT JAMB <br />DOOR PER SCHEDULE (DOOR <br />BOTTOM WHERE OCCURS) <br />1/4" WIDE CONT. SEALANT BEAD - <br />BOTH SIDES <br />CERAMIC FLOOR TILE <br />CONC. SLAB <br />MARBLE THRESHOLD W/ POLISHED <br />FINISH -FULL DEPTH OF DOOR <br />FRAME. NOTCH AT JAMB <br />DOOR PER SCHEDULE (DOOR <br />BOTTOM WHERE OCCURS) <br />1/4" WIDE CONT. SEALANT BEAD - <br />BOTH SIDES <br />CERAMIC FLOOR TILE <br />MORTAR BED <br />SECTION <br />ASTRAGALGUIDE <br />SEAL <br />ROLLING DOOR <br />CHAIN KEEPER PADLOCK <br />BY G.C MAX. 1/4"∅SHANK <br />MID-HOOD SUPPORT; <br />WHEN REQUIRED; SOLID <br />WALL CONSTRUCTION <br />REQ'D.SPRING <br />ADJUSTOR <br />HOOD <br />AUXILIARY <br />HAND CHAIN <br />HOOD <br />BAFFLE <br />PLAN OF OPENING <br />STEEL BRACKET PLATE ABOVE <br />WEATHER STRIPPING <br />GUIDE TRACK PER MFR. <br />ELEVATION <br />OP <br />E <br />N <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />OV <br />E <br />R <br />A <br />L <br />L <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />2"15" <br />20 <br />" <br /> <br />+ <br />/ <br />- <br />2" <br />5" <br />8"8" <br />OPENING WIDTH <br />1/2" CLEAR TEMPERED GLASS <br />BOTTOM CORNER PATCH <br />FINISHED CONCRETE FLOOR <br />TOP PIVOT HARDWARE WITH <br />CORNER PATCH WITH RECESSED, <br />CONCEALED CLOSER <br />EXISTING FLOOR STRUCTURE ABOVE <br />SLOTTED HEAD TRACK (ICC-ESR-3064P) <br />ATTACHED TO STRUCTURE WITH <br />FASTENERS @ 24" O.C. AND 2" FROM <br />EACH END (HILTI-ICC-ESR-2269) - <br />REFER TO DETAIL <br />25 GAUGE METAL STUDS GANGED <br />TO FORM TOP HEADER <br />5/8" TYPE 'X' GYP. BD. OVER METAL <br />STUD FRAMING <br />SEISMIC BRACING @ 48" O.C., EACH <br />DIRECTION AS REQUIRED <br />BOTTOM PIVOT ASSEMBLY <br />HHENDY.COM <br />T (949) 851-3080 <br />4770 Campus Dr., Suite 100 <br />Newport Beach, CA 92660 <br />H ndy <br />ISSUES AND REVISIONS <br />JOB NUMBER <br />SCALE <br />PROJECT <br />TEAM <br />All specifications, drawings, concepts, designs, arrangements, intellectual and written material represented herein constitute <br />unique and unpublished work of H. Hendy Associates and may not be copied, used by or disclosed to others without written <br />consent of H. Hendy Associates. <br /> 2023 H.HendyAssociatesc <br />DATE <br />As indicated <br />04463.0000.24 <br />3080 S. HARBOR BLVD. <br />SANTA ANA, CA 92704 <br />DOOR SCHEDULE & DETAILS <br />IA-8.1 <br />MCGUFF <br />AB/CD <br />DOOR <br />NUMBER <br />FIRE RATING <br />(MIN) <br />DOOR FRAME HARDWARE <br />COMMENTS <br />TY <br />P <br />E <br />WI <br />D <br />T <br />H <br />HE <br />I <br />G <br />H <br />T <br />MA <br />T <br />E <br />R <br />I <br />A <br />L <br />FI <br />N <br />I <br />S <br />H <br />MA <br />T <br />E <br />R <br />I <br />A <br />L <br />FI <br />N <br />I <br />S <br />H <br />GR <br />O <br />U <br />P <br />PA <br />N <br />I <br />C <br />AC <br />C <br />E <br />S <br />S <br /> <br />C <br />O <br />N <br />T <br />R <br />O <br />L <br />101 - - 6' - 0" 9' - 0" - Y EXISTING DOOR -RETROFIT WITH CARD READER <br />102 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />103 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />104 - - 3' - 0" 7' - 0" Y EXISTING DOOR -RETROFIT WITH CARD READER <br />105 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />106 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />107 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />108 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />109 - - 6' - 0" 9' - 0" - EXISTING TO REMAIN <br />109A - - 6' - 0" 7' - 0" - EXISTING TO REMAIN <br />111 - - 3' - 0" 9' - 0" Y EXISTING DOOR -RETROFIT WITH CARD READER <br />111A - C 12' - 0" 14' - 0" MTL MFR MFR MFR MFR - - COOKSON THERMISER MAX MODEL ESD30 <br />112 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />113 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />114 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />114A - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />115 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />116 - A 3' - 0" 8' - 0" WD PT KD PT H4 - - - <br />118 - - 3' - 0" 8' - 0" - EXISTING DOOR -RETROFIT WITH CARD READER <br />118A - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />119 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />120 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />120A - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />120A1 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />120A2 - - 3' - 0" 9' - 0" Y EXISTING DOOR -RETROFIT WITH CARD READER <br />121 - - 3' - 0" 9' - 0" Y EXISTING DOOR -RETROFIT WITH CARD READER <br />122 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />123 - A 3' - 0" 8' - 0" WD PT KD PT H5 - - - <br />124 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />124A - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />125 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />126 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />127 - - 3' - 0" 9' - 0" Y EXISTING DOOR -RETROFIT WITH CARD READER <br />127A - C 12' - 0" 14' - 0" MTL MFR MFR MFR MFR - - COOKSON THERMISER MAX MODEL ESD30 <br />200 - - 3' - 0" 8' - 0" Y EXISTING DOOR -RETROFIT WITH CARD READER <br />200A - - 3' - 0" 8' - 0" Y - <br />201 - D 6' - 0" 8' - 0" GLASS TEMPER MFR MFR MFR HERCULITE DOOR AND FRAME <br />202 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />203 - - 3' - 0" 8' - 0" - - <br />204 - A 3' - 0" 8' - 0" WD PT KD PT H5 - - EXISTING TO REMAIN <br />204A - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />205 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />206 - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />206A - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />207 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />208 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />209 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />210 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />303 - A 4' - 0" 8' - 0" WD PT KD PT H4 - - - <br />304A - A 3' - 0" 8' - 0" WD PT KD PT H6 - - - <br />304B - A 3' - 0" 8' - 0" WD PT KD PT H6 - - - <br />307 - - 3' - 0" 9' - 0" Y COOKSON THERMISER MAX MODEL ESD30 <br />307 - - 3' - 0" 7' - 0" - EXISTING DOOR -RETROFIT WITH CARD READER <br />308 - A 3' - 0" 8' - 0" WD PT KD PT H4 - - - <br />311 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />311A - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />401 - - 3' - 0" 9' - 0" - EXISTING TO REMAIN <br />401A - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />401B - - 3' - 0" 7' - 0" - EXISTING TO REMAIN <br />402 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />403 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />404 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />405 - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />405A - - 3' - 0" 8' - 0" - EXISTING TO REMAIN <br />DOOR SCHEDULE <br />ABBREVIATIONS: <br />AL ALUMINUM <br />ANO ANODIZED <br />FF FACTORY FINISH <br />HM HOLLOW METAL <br />KD KNOCK DOWN <br />MIN MINUTE <br />P PAINT; REFER TO FINISH SCHEDULE FOR COLOR <br />STL STEEL <br />WD WOOD <br />Y YES <br />SCALE <br />3" = 1'-0"11HOLLOW METAL DOOR FRAMESCALE <br />3" = 1'-0"15KNOCK DOWN FRAME <br />SCALE <br />1/2" = 1'-0"9PANIC HARDWARE <br />SCALE <br />1/2" = 1'-0"10TYPICAL CARD READER CONNECTION <br />SCALE <br />6" = 1'-0"13MARBLE THRESHOLDSCALE <br />1/2" = 1'-0"17COILING DOOR <br />NO. DESCRIPTION DATE <br />PLAN CHECK SUBMITTAL 3/17/25 <br />NOTE: <br />REFINISH STAIN GRADE DOORS IF DAMAGEDSCALE <br />3" = 1'-0"19HERCULITE DOOR <br />19 <br />-
The URL can be used to link to this page
Your browser does not support the video tag.