Laserfiche WebLink
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, PROJECT BOUNDARIES AND EXISTING CONDITIONS AT THE SITE <br />PRIOR TO COMMENCEMENT OF WORK AND IMMEDIATELY NOTIFY STRUCTURAL ENGINEER OF RECORD (SEOR) AND <br />ARCHITECT OF RECORD (AOR) OF ANY DISCREPANCY. THE CONTRACTOR SHALL CHECK DETAILS AND <br />DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RE LATED REQUIREMENTS ON OTHER CONTRACT <br />DOCUMENTS. <br /> <br />2. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE STRUCTURAL ENGINEER OF RECORD (SEOR) OF ANY <br />CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER CONSTRUCTION DOCUMENTS OR EXISTING <br />CONDITIONS NOT SHOWN OR DIFFERENT THAN THOSE SHOWN ON CONTRACT DOCUMENT PRIOR TO <br />COMMENCEMENT OF WORK. THE CONTRACTOR SHALL NOT ORDER MATERIAL, FABRICATE ELEMENTS, OR <br />CONSTRUCT ANY PORTION OF STRUCTURE THAT IS IN CONFLICT UNTIL RESOLUTION IS MADE. IN THE EVENT OF <br />CONFLICTS, INCONSISTENCIES AND DISCREPANCIES BETWEEN OR AMONG THE CONTRACT DOCUMENTS THE <br />AOR/SEOR DECIDE WHICH OF THE CONFLICTING REQUIREMENTS WILL GOVERN BASED UPON THE MOST <br />STRINGENT OF THE REQUIREMENTS. THE CONTRACTOR SHALL PERFORM THE WORK CONSISTENT WITH THE <br />AOR/SEOR'S DECISION WITHOUT ADJUSTMENT OF THE CONTRACT SUM OR CONTRACT TIME. <br />3. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED BY CONTRACTOR AGAINST ARCHITECTURAL <br />DIMENSIONS. WHERE DIMENSIONS ARE UNCLEAR OR OMITTED, REQUEST CLARIFICATION FROM THE STRUCTURAL <br />ENGINEER OF RECORD (SEOR) AND ARCHITECT OF RECORD (AOR). DO NOT SCALE DRAWINGS. UNLESS NOTED <br />OTHERWISE, PLAN DIMENSIONS INDICATE CENTERLINE OF BEAMS AND COLUMNS. LIGHT-FRAMED WALLS ARE <br />DIMENSIONED TO FACE OF STUDS, AND FOOTINGS ARE CENTERED UNDER THE ELEMENTS THEY SUPPORT. <br />ALL DIMENSIONS RELATED TO EXISTING CONDITIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO <br />START OF WORK. <br />4. SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF DOOR AND WINDOW OPENINGS IN STRUCTURAL <br />WALLS; SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS AND SLAB EDGES; SIZE AND LOCATION OF NON- <br />BEARING WALLS AND OPENINGS; SIZE AND LOCATION OF CONCRETE CURBS, SLOPES, DEPRESSIONS, DRAINS, <br />NON-STRUCTURAL PARTITIONS, CHANGES IN LEVEL, CHAMFERS AND REVEALS, INSERTS FOR FINISH SYSTEMS; <br />EXTERIOR WALL FINISHES; STAIR SIZE, LOCATION, FRAMING AND DETAILS, UNLESS DETAILED ON STRUCTURAL <br />DRAWINGS; DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS. <br />5. PROJECT SPECIFICATIONS SHALL BE A PART OF THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR <br />BETWEEN GENERAL NOTES, PLANS, DETAILS AND SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS SHALL <br />GOVERN. SPECIFIC NOTES AND DETAILS ON DRAWINGS GOVERN OVER GENERAL NOTES AND TYPICAL DETAILS. <br />NOTIFY THE ARCHITECT OF RECORD (AOR) AND STRUCTURAL ENGINEER OF RECORD (SEOR) IMMEDIATELY WHERE <br />CONFLICT OCCURS BETWEEN DRAWINGS AND SPECIFICATIONS. AOR/SEOR DECIDE WHICH OF THE CONFLICTING <br />REQUIREMENTS WILL GOVERN BASED UPON THE MOST STRINGENT OF THE REQUIREMENTS. <br />6. REFER TO THE TYPICAL DETAIL SHEETS FOR TYPICAL CONS TRUCTION DETAILS. TYPICAL DETAILS APPLY TO ALL <br />CONSTRUCTION DOCUMENTS AND MAY NOT BE SPECIFICALLY REFERENCED THEREIN. UNLESS SPECIFICALLY <br />NOTED OR SHOWN OTHERWISE, CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING THESE TYPICAL DETAILS PRIOR <br />TO COMMENCEMENT OF WORK. WHERE CONDITIONS REQUIRE M ODIFICATIONS OF A TYPICAL DETAIL, THE <br />CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD <br />(SEOR) PRIOR TO FABRICATION AND INSTALLATION. DETAIL OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME <br />NATURE AS THOSE SHOWN FOR SIMILAR CONSTRUCTION. <br />7. SCHEDULE CONSTRUCTION OPERATIONS IN SEQUENCE REQUIRED TO OBTAIN THE BEST RESULTS, WHERE <br />INSTALLATION OF ONE PART OF THE WORK DEPENDS ON INSTALLATION OF OTHER COMPONENTS, BEFORE OR <br />AFTER ITS OWN INSTALLATION. COORDINATE INSTALLATION OF DIFFERENT COMPONENTS TO ENSURE MAXIMUM <br />PERFORMANCE AND ACCESSIBILITY FOR REQUIRED MAINTENANCE, SERVICE, AND REPAIR. <br /> <br />8. THESE DOCUMENTS SHALL NOT BE CONSTRUED AS STAND-ALONE DOCUMENTS. CONTRACTOR SHALL <br />COORDINATE WITH ALL OTHER CONSULTANTS' WORK. <br />9. MODIFICATIONS AND SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON STRUCTURAL DRAWINGS MUST BE <br />ACCEPTED IN WRITING BY STRUCTURAL ENGINEER OF RECORD (SEOR) PRIOR TO COMMENCEMENT OF WORK. <br />CURRENT EVALUATION REPORTS AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE STRUCTURAL <br />ENGINEER DEMONSTRATING ADEQUACY OF THE REQUIRED CAPACITY AND PERFORMANCE OF THE MATERIAL TO <br />BE SUBSTITUTED. ARCHITECT OF RECORD (AOR) AND STRUCTURAL ENGINEER OF RECORD (SEOR), AT THEIR <br />DISCRETION, MAKE DETERMINATION AS TO WHETHER OR NOT THE PROPOSED CONTRACTOR'S MODIFICATIONS <br />AND/OR SUBSTITUTIONS IS ACCEPTABLE. <br />10. CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE MEANS AND <br />METHODS OF CONSTRUCTION OR NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THE CONTRACTOR IS <br />SOLELY RESPONSIBLE FOR THE DESIGN OF TEMPORARY ERECTION AIDS, FORMWORK, SCAFFOLDING, SAFETY <br />MEASURES, SHORING OF ANY PORTION OF WORK DUE TO CONSTRUCTION EQUIPMENT, MACHINERY AND <br />MATERIALS, AND PROTECTION OF ADJACENT PROPERTIES. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE <br />WORK AND SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS AND METHODS, TECHNIQUES, SEQUENCES <br />AND PROCEDURES. VISITS TO THE SITE BY THE STRUCTURAL ENGINEER OF RECORD (SEOR) AND ARCHITECT OF <br />RECORD (AOR) SHALL NOT CONSTITUTE ACCEPTANCE OF CONSTRUCTION MEANS AND METHODS AND DO NOT IN <br />ANY WAY RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES FOR THE ABOVE. CONSTRUCTION MATERIALS AND <br />ERECTION LOADS SHALL BE DISTRIBUTED WHEN PLACED ON THE STRUCTURE SUCH THAT THEY DO NOT EXCEED <br />DESIGN LIVE LOADS OR RESULT IN AN UNBALANCED LOADING CONDITION. CONSTRUCTION LOADS ON ELEVATED <br />SLABS SHALL NOT RESULT IN EXCESSIVE SHORT-TERM OR LONG-TERM DEFLECTIONS. <br /> <br />11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS OF THE LATEST EDITION <br />OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF CALIFORNIA, AND ALL OCCUPATIONAL <br />SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS AS THEY APPLY TO THE PROJECT. THE <br />STRUCTURAL ENGINEER OF RECORD (SEOR) AND THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR THE <br />CONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS. <br />12. ALL STRUCTURAL FRAMING SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY BRACING, AS REQUIRED, <br />SHALL BE INSTALLED AND LEFT IN PLACE UNTIL ADEQUATE PORTION OF THE STRUCTURE IS CONSTRUCTED FOR <br />STABILITY. <br />13. MAXIMUM PERMANENT EQUIPMENT WEIGHTS, POSTED LOAD LIMITS OR OTHER RESTRICTIONS NOTED ON THE <br />STRUCTURAL DRAWINGS SHALL NOT BE EXCEEDED WITHOUT PRIOR WRITTEN APPROVAL BY THE STRUCTURAL <br />ENGINEER OF RECORD (SEOR). UNLESS SPECIFICALLY STATED, THE STRUCTURE IS NOT DESIGNED TO SUPPORT <br />TRAFFIC FROM FORK LIFTS, CRANES OR OTHER HEAVY CONSTRUCTION VEHICLES. ADEQUACY OF THE <br />STRUCTURE TO SUPPORT TEMPORARY LOADS DURING CONSTRUCTION SHALL BE VERIFIED BY A LICENSED <br />SHORING ENGINEER RETAINED BY CONTRACTOR. SHORING SYSTEM SHALL BE DESIGNED AS A COMPLETE SYSTEM <br />THAT INCLUDES BUT NOT LIMITED TO GRAVITY LOADS AND LATERAL LOADS. <br />14. THESE DRAWINGS SHALL NOT BE USED FOR CONSTRUCTION IF THE STRUCTURAL ENGINEER'S SEAL AND <br />SIGNATURE IS NOT AFFIXED TO THESE DRAWINGS. <br />15. CONTRACTOR SHALL ESTABLISH AND VERIFY SIZE AND LOCATION OF ALL OPENINGS AND INSERTS BY ALL TRADES <br />PRIOR TO SUBMITTAL OF SHOP DRAWINGS AND CONSTRUCTION. PENETRATION THROUGH SLABS AND WALLS <br />SHALL BE IDENTIFIED BY CONTRACTOR AND SUBMITTED TO STRUCTURAL ENGINEER OF RECORD (SEOR) FOR <br />REVIEW AND APPROVAL PRIOR TO PLACEMENT OF CONCRETE OR CMU. CORE DRILLING SHALL ONLY BE <br />PERMITTED WHERE AUTHORIZED IN WRITING BY SEOR PRIOR TO PROCEEDING WITH THE WORK. CORE DRILLS <br />SHALL NOT CUT ANY REINFORCING, UNLESS PERMITTED BY SEOR IN WRITING. INSPECTOR OF RECORD (IOR) <br />SHALL BE PRESENT DURING CORE DRILLING FOR VERIFICATION. THE IOR IS TO DOCUMENT CORES EXAMINED <br />INDICATING AN ABSENCE OF REINFORCING. <br />16. STRUCTURAL DRAWINGS INDICATE THE APPROXIMATE LOCATION OF EQUIPMENTS AND THEIR SECONDARY <br />FRAMING SUPPORTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN <br />SUBCONTRACTORS. IN ORDER TO PROVIDE NECESSARY DIMENSIONS IN A TIMELY MANNER TO ALL PARTIES <br />INVOLVED. SECONDARY FRAMING SUPPORTING EQUIPMENTS SHALL BE PER TYPICAL DETAILS UNLESS <br />SPECIFICALLY NOTED OTHERWISE ON PLANS. <br />17. SEE MECHANICAL, ELECTRICAL, AND PLUMBING (MEP) DRAWINGS FOR SIZE AND LOCATION OF EQUIPMENT PADS, <br />EQUIPMENT ANCHORAGE TO STRUCTURE, AND EQUIPMENT WEIGHTS; ANCHORAGE AND SEISMIC BRACING OF <br />DUCTWORK, PIPING, ELECTRICAL CONDUITS TO STRUCTURE; ELECTRICAL CONDUIT RUNS, OUTLETS AND BOXES IN <br />CONCRETE SLABS AND WALLS; PIPE SLEEVES, TRENCHES, OPENINGS THROUGH WALLS AND SLABS FOR <br />DUCTWORK, PIPE RUNS, AND ELECTRICAL CONDUIT RUNS. <br />18. MAKE ALLOWANCE FOR SHIM SPACE AT HEADERS AND JAMBS TO ALLOW FOR SETTLEMENT, DEFELCTION, AND <br />MOVEMENT OF FRAMING. INSTALL WINDOWS, DOORS AND OTHER INSET ITEMS IN WALLS AFTER BUILDING LOADS <br />ARE FULLY APPLIED. <br />19. STRUCTURAL JOINT DIMENSIONS SHOWN ON STRUCTURAL DRAWINGS (EXPANSION, SEISMIC, SEPARATION, ETC) <br />INDICATE THE MINIMUM CLEAR DISTANCE REQUIRED STRUCTURALLY. REFER TO ARCHITECTURAL DRAWINGS FOR <br />ADDITIONAL REQUIREMENTS AND INFORMATION. ALL PIPES, DUCTS, CONDUIT, ETC., CROSSING SUCH JOINTS <br />SHALL HAVE FLEXIBLE LINES WITH ADEQUATE RANGE OF MOTION. <br />20. REFER TO THE PROJECT SPECIFICATIONS FOR SHOP DRAWING REQUIREMENTS AND SUBMITTALS. SHOP <br />DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD (SEOR) PRIOR TO FABRICATION. <br />ALLOW FOR A REVIEW DURATION OF MINIMUM 10 BUSINESS DAYS. SUBMITTALS SHALL CONSIST OF EITHER <br />ELECTRONIC FILES OR TWO HARD COPIES (ONE SET TO BE KEPT BY THE STRUCTURAL ENGINEER OF RECORD AND <br />ONE REPRODUCIBLE SET TO BE RETURNED TO CONTRACTOR). <br />1. GOVERNING CODE: <br />ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 CALIFORNIA BUILDING CODE (CBC 2022), INCLUDING ALL <br />AMENDMENTS AND SUPPLEMENTS BY GOVERNING CODE AUTHORITY, AND OTHER CODES AND STANDARDS <br />REFERENCED IN THE CONTRACT DOCUMENTS. ALL CODES AND STANDARDS REFERENCED IN CONTRACT <br />DOCUMENTS SHALL BE THE LATEST EDITION AS NOTED BY CBC 2022, CHAPTER 35, UNO. <br />2. GOVERNING CODE AUTHORITY: <br />CITY OF SANTA ANA -BUILDING AND SAFETY DIVISION. <br />3. GRAVITY DESIGN LOADS: <br />ROOF LIVE LOAD.................................................................................................................................................................20 PSF <br />4. WIND DESIGN DATA: <br />BASIC DESIGN WIND SPEED...........................................................................................................................................95 MPH <br />WIND EXPOSURE.........................................................................................................................................................................C <br />RISK CATEGORY..........................................................................................................................................................................II <br />BUILDING ENCLOSURE.........................................................................................................................PARTIALLY ENCLOSED <br />INTERNAL PRESSURE COEFFICIENT.................................................................................................................................+0.18 <br />5. EARTHQUAKE DESIGN DATA: <br />SITE LATITUDE...........................................................................................................................................................33.706123 N <br />SITE LONGITUDE...................................................................................................................................................-117.920384 W <br />RISK CATEGORY...........................................................................................................................................................................II <br />SEISMIC IMPORTANCE FACTOR, Ie.......................................................................................................................................1.00 <br />SITE CLASS...................................................................................................................................................................................D <br />SHORT-PERIOD SITE COEFFICIENT, Fa.................................................................................................................................1.2 <br />LONG-PERIOD SITE COEFFICIENT, Fv................................................................................................................................1.833 <br />SITE-SPECIFIC SPECTRAL RESPONSE ACCELERATION, Ss......................................................................................1.315 g <br />SITE-SPECIFIC SPECTRAL RESPONSE ACCELERATION, S1.......................................................................................0.472 g <br />DESIGN SPECTRAL RESPONSE ACCELERATION, SDS.................................................................................................1.052 g <br />DESIGN SPECTRAL RESPONSE ACCELERATION, SD1.................................................................................................0.577 g <br />SEISMIC DESIGN CATEGORY....................................................................................................................................................D <br />SEISMIC BASE......................................................................................................................GROUND LEVEL (DATUM EL 41.2) <br />6. SEISMIC FORCE-RESISTING SYSTEM (SFRS): <br />NON-STRUCTURAL ELEMENTS <br />21.REVIEW OF SHOP DRAWINGS AND SUBMITTALS BY THE ARCHITECT OF RECORD (AOR) AND STRUCTURAL <br />ENGINEER OF RECORD (SEOR) IS FOR GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS AND DOES NOT <br />CONSTITUTE AUTHORIZATION TO DEVIATE FROM TERMS AND CONDITIONS OF THE CONTRACT. THE CONTRACTOR <br />WILL REMAIN RESPONSIBLE FOR ALL ERRORS IN DETAILING, FABRICATION, AND FOR CORRECT FITTING OF ALL <br />STRUCTURAL MEMBERS, INCLUDING COORDINATION WITH OTHER TRADES. <br />22. SHOP DRAWINGS AND SUBMITTALS DO NOT CONSTITUTE CHANGE ORDERS. ANY PROPOSED CHANGES TO THE <br />STRUCTURAL DOCUMENTS MUST BE SUBMITTED IN WRITING AS A REQUEST FOR SUBSTITUTION TO THE <br />ARCHITECT AND SEOR FOR APPROVAL. <br />23. PREPARE TO-SCALE PROJECT-SPECIFIC SHOP DRAWINGS. SHOP DRAWINGS SHALL BE INDEPENDENTLY <br />PRODUCED BY THE CONTRACTOR AND SHALL NOT BE A COPY OR REPRODUCTION OF THE CONTRACT <br />DOCUMENTS. <br />24. ALL WORK IS NEW UNLESS INDICATED AS EXISTING (E). <br />25. IN AN EXISTING STRUCTURE WHERE MODIFICATIONS TO AN EXISTING LOAD-BEARING WALL IS REQUIRED, <br />PROVIDE TEMPORARY BRACING/SHORING UNTIL NEW LOAD-BEARING WALL CONSTRUCTION IS COMPLETED AND <br />LOAD PATH IS RESTORED. <br />GENERAL REQUIREMENTS GENERAL REQUIREMENTS (CONTINUED) <br />STRUCTURAL DESIGN CRITERIA <br />1. REVIEW OF SHOP DRAWINGS AND SUBMITTALS BY THE AOR AND SEOR IS FOR GENERAL COMPLIANCE WITH THE <br />CONTRACT DOCUMENTS. <br />2. SHOP DRAWINGS SHALL BE SUBMITTED TO THE SEOR FOR REVIEW PRIOR TO FABRICATION. THE CONTRACTOR <br />WILL REMAIN RESPONSIBLE FOR ALL ERRORS OF DETAILING, FABRICATION, AND FOR CORRECT FITTING OF ALL <br />STRUCTURAL MEMBERS INCLUDING COORDINATION WITH OTHER TRADES. <br />3. SHOP DRAWINGS SHALL BE SUBMITTED TO THE SEOR (ALLOW FOR A REVIEW DURATION OF 10 BUSINESS DAYS), <br />AND SHALL CONSIST OF EITHER ELECTRONIC FILES OR ONLY ONE SET FOR OUR RECORDS AND ONE <br />REPRODUCIBLE SET. <br />4. SEOR WILL RETURN THE ELECTRONIC FILES OR REPRODUCIBLE SET CLEARLY MARKED WITH COMMENTS. ANY <br />REQUIRED RECORD SET COPIES SHALL BE MADE FROM THIS RETURNED SET. <br />5. REPRODUCTION OF STRUCTURAL PLANS & DETAILS FOR SHOP DRAWINGS IS PROHIBITED. <br />SUBCONTRACTOR/FABRICATOR IS TO PROVIDE INDEPENDENTLY CREATED DRAWINGS BASED ON THE <br />STRUCTURAL PLANS AND DETAILS. <br />6. SHOP DRAWINGS AND SUBMITTALS DO NOT CONSTITUTE CHANGE ORDERS. ANY PROPOSED CHANGES TO THE <br />STRUCTURAL DOCUMENTS MUST BE SUBMITTED IN WRITING AS A REQUEST FOR SUBSTITUTION TO THE <br />ARCHITECT AND SEOR FOR APPROVAL. <br />7. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND OR SEISMIC FORCE-RESISTING <br />SYSTEM, DESIGNATED SEISMIC SYSTEM OR A WIND-OR SEISMIC-RESISTING COMPONENT LISTED IN THE <br />STATEMENT OF SPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE <br />BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR <br />COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL CONTAIN ACKNOWLEDGEMENT OF <br />AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTION. <br />8. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL DOCUMENTS MAY BE CONSIDERED <br />WITH MATERIALS HAVING EQUIVALENT OR GREATER CAPACITY AND PERFORMANCE. CURRENT EVALUATION <br />REPORTS AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE SEOR DEMONSTRATING EQUIVALENT <br />QUALITIES OF THE MATERIAL TO BE SUBSTITUTED. <br />THE FOLLOWING LIST SUMMARIZES IMPORTANT STRUCTURAL SUBMITTALS FOR THIS PROJECT. <br />REFER TO THE SPECIFICATIONS FOR A COMPLETE LIST AND ADDITIONAL REQUIREMENTS. <br />GENERAL <br />•QUALIFICATION DATA FOR APPROVED INSTALLERS AND FABRICATORS <br />•CERTIFICATES OF CONFORMANCE FOR PREFABRICATED MEMBERS <br />CONCRETE FORMWORK <br />•MANUFACTURER'S PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR PROPRIETARY MATERIALS <br />INCLUDING FORM COATINGS, MANUFACTURED FORM SYSTEMS, TIES AND ACCESSORIES <br />•SHOP DRAWINGS FOR FABRICATION AND ERECTION OF FORMWORK AND SHORING <br />CONCRETE REINFORCEMENT <br />•MANUFACTURER'S PRODUCT DATA, SPECIFICATIONS AND INSTALLATION PROCEDURES FOR PROPRIETARY <br />MATERIALS AND REINFORCEMENT <br />•STEEL PRODUCER'S CERTIFICATES OF MILL ANALYSIS, TENSILE AND BEND TESTS <br />•SHOP DRAWINGS FOR FABRICATION, BENDING AND PLACEMENT <br />CAST-IN-PLACE CONCRETE <br />•DESIGN MIX FOR EACH CONCRETE MIX <br />•MATERIAL TEST REPORTS <br />•MATERIAL CERTIFICATES FOR CEMENT, AGGREGATES AND ADMIXTURES <br />•MANUFACTURER'S PRODUCT DATA FOR WATERSTOPS, BONDING AGENTS, VAPOR RETARDERS, JOINT FILLER, <br />CURING MATERIALS AND FLOOR TREATMENTS <br />•SHOP DRAWINGS FOR PROPOSED LOCATIONS OF ADDITIONAL CONSTRUCTION OR CONTROL JOINTS NOT <br />SHOWN <br />ON THE STRUCTURAL PLANS <br />•MINUTES FROM PREINSTALLATION CONFERENCE <br />STRUCTURAL STEEL <br />•MANUFACTURER'S MILL CERTIFICATES <br />•MILL TEST REPORTS <br />•SHOP DRAWINGS FOR FABRICATION AND ASSEMBLY OF MEMBERS <br />•ERECTION PLAN SEQUENCE AND PROCEDURES <br />•WELDING PROCEDURE SPECIFICATIONS (WPS) <br />•TEST REPORTS FOR SHOP AND FIELD WELDED AND BOLTED CONNECTIONS <br />COLD-FORMED METAL FRAMING <br />•SHOP DRAWINGS INDICATING LAYOUT AND DETAILS <br />•ENGINEERING CALCULATIONS <br />ROUGH CARPENTRY <br />•PRODUCT DATA FOR TREATMENTS AND PRESERVATIVES <br />•MATERIAL CERTIFICATES FOR DIMENSION LUMBER <br />PREFABRICATED WOOD PRODUCTS <br />•SHOP DRAWINGS INDICATING LAYOUT & DETAILS <br />•ENGINEERING CALCULATIONS <br />GLUE LAMINATED BEAMS <br />•SHOP DRAWINGS INDICATING LAYOUT <br />•CERTIFICATE OF CONFORMANCE <br />STRUCTURAL SUBMITTALS <br />1. SEE "AS-BUILT" DRAWINGS FOR EXISTING BUILDING ITEMS NOT SHOWN OR NOTED. <br />2. FIELD VERIFY ALL CONDITIONS & DIMENSIONS PRIOR TO SHOP DRAWING PRODUCTION AND FABRICATION OF <br />STRUCTURAL ELEMENTS. <br />3. WHERE ALL OTHER EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE SHOWN ON THESE DRAWINGS, <br />THE STRUCTURAL ENGINEER SHALL BE NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT <br />CONDITIONS. <br />4. SHORE ALL EXISTING CONSTRUCTION AS REQUIRED, INCLUDING WHERE WELDING TO EXISTING STEEL FRAMING. <br />SHORING DESIGN BY OTHERS. <br />5. ALL EXISTING CONCRETE SURFACES TO BE IN CONTACT WITH NEW CONCRETE SHALL BE ROUGHENED TO 1/4" <br />MINIMUM AMPLITUDE. USE ICC APPROVED BONDING AGENT ON EXISTING CONCRETE PRIOR TO PLACING NEW <br />CONCRETE. <br />6. VERIFY LOCATION OF EXISTING REBAR BEFORE FABRICATION USING NON-DESTRUCTIVE TESTING. EXISTING <br />REINFORCING SHALL BE AVOIDED WHERE DRILLING FOR POST-INSTALLED ANCHORS OR CONCRETE DOWELS. <br />7. THE GENERAL CONTRACTOR SHALL COORDINATE THE WEIGHT AND SPECIFIC LOCATION OF ALL MECHANICAL <br />EQUIPMENT WITH THE STRUCTURAL FRAMING. IF THE EQUIPMENT DEVIATES IN WEIGHT OR LOCATION FROM <br />THOSE INDICATED IN THE DRAWINGS, THE STRUCTURAL ENGINEER'S APPROVAL MUST BE OBTAINED PRIOR TO <br />INSTALLATION OF THE UNITS. <br />8. ALL EXISTING WOOD FRAMING MEMBERS SUPPORTING NEW MECHANICAL UNITS SHALL BE INSPECTED FOR <br />DAMAGE AND DETERIORATION PRIOR TO INSTALLATION OF THE UNITS. NOTIFY THE STRUCTURAL ENGINEER IF <br />DAMAGE OR DETERIORATION IS DISCOVERED. <br />9. ALL EXISTING (E) WOOD ELEMENTS TO REMAIN SHALL BE FIELD INSPECTED DURING CONSTRUCTION AND <br />TREATED FOR DRYROT REMOVAL / CONTROL. WHERE EXISTING GLUE LAMINATED TIMBER BEAMS TO REMAIN ARE <br />FOUND TO HAVE EXTENSIVE DRYROT DEEPER THAN THE TOP TWO LAMINATIONS (3"), THE STRUCTURAL <br />ENGINEER SHALL BE NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT GLUE LAMINATED <br />TIMBER BEAMS . <br />10. ALL EXISTING CONNECTIONS AT ELEMENTS TO BE REPLACED SHALL BE REPLACED OR RE-ATTACHED TO MATCH <br />EXISTING CONDITIONS. <br />11. SEE PROJECT REPORTS AND ARCHITECTURAL DRAWINGS FOR HAZARDOUS MATERIALS (LEAD, ASBESTOS, ETC.) <br />ABATEMENT REQUIREMENTS. <br />12. DO NOT CUT OR DAMAGE EXISTING CONCRETE OR MASONRY REINFORCEMENT EXCEPT AS CLEARLY INDICATED <br />ON STRUCTURAL DRAWINGS. MAINTAIN AT LEAST 2 INCHES CLEAR TO EXISTING REINFORCEMENT, CONDUIT AND <br />OTHER EMBEDDED ITEMS FROM CUTS, CORES, DRILL HOLES, SHOTPINS, ETC. IN AREAS OF WORK, MARK <br />LOCATIONS OF SUCH ITEMS USING NONDESTRUCTIVE METHODS SUCH AS GROUND PENETRATING RADAR OR X- <br />RAY. <br />1. POST-INSTALLED ANCHORS INCLUDE EXPANSION ANCHORS, SCREW ANCHORS, EPOXY ANCHORS/DOWELS, <br />AND POWDER-ACTUATED FASTENERS. <br />2. INSTALL POST-INSTALLED ANCHORS PER MANUFACTURER'S RECOMMENDED SPECIFICATIONS. <br />3. WHEN INSTALLING POWER-INSTALLED ANCHORS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE, <br />USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCING BARS OR OTHER EMBEDDED <br />ITEMS SUCH AS ELECTRICAL/TELECOMMUNICATIONS CONDUIT AND GAS LINES. WHEN INSTALLING DRILL-IN <br />ANCHORS INTO PRESTRESSED CONCRETE (PRE OR POST-TENSIONED), LOCATE TENDONS DURING <br />INSTALLATION BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE <br />AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM <br />CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. <br />4. WHERE SPECIFIED ANCHOR EMBEDMENT DEPTH, SPACING OR EDGE DISTANCE CANNOT BE PROVIDED, NOTIFY <br />THE SEOR AND IOR PRIOR TO INSTALLATION. <br />5. PATCH ABANDONED HOLES AND SPALLS USING NON-SHRINK GROUT AND REPAIR FINISHES AS REQUIRED. <br />ANCHORS PENETRATING THROUGH WATER PROOFING OR VAPOR MEMBRANES SHALL BE SEALED OR <br />FLASHED. <br />6. TESTING OF POST-INSTALLED ANCHORS IS REQUIRED UNO. TEST ANCHORS IN ACCORDANCE WITH THE <br />PROVISIONS OF CBC 19010A.5 AND THE FOLLOWING: <br />a. TEST 100% OF ANCHORS AT ALL STRUCTURAL APPLICATIONS UNO. <br />b. TEST 50% OF ANCHORS AT ALL-NON-STRUCTURAL APPLICATIONS SUCH AS EQUIPMENT <br />ANCHORAGE, UNO. <br />c. IF ANY ANCHOR FAILS TESTING, TEST ALL ANCHORS OF THE SAME TYPE NOT PREVIOUSLY <br />TESTED UNTIL TWENTY (20) CONSECUTIVE ANCHORS PASS, THEN RESUME INITIAL TEST <br />FREQUENCY. IF THE ANCHORS ARE USED FOR THE SUPPORT AND BRACING OF NON-STRCTURAL <br />COMPONENTS (PIPE, DUCT, OR CONDUIT), THE TWENTY (20) SHALL BE ONLY THOSE ANCHORS <br />INSTALLED BY THE SAME TRADE. <br />d. ALL POST-INSTALLED ANCHORS ARE TO BE TENSION TESTED WITH THE EXCEPTION THAT <br />TORQUE TESTING IS ALLOWED IF THE ANCHORS ARE SPECIFICALLY DESIGNED AS TORQUE <br />CONTROLLED. <br />e. TENSION TESTS ACCEPTANCE: APPLY PROOF TEST LOADS TO ANCHORS WITHOUT REMOVING <br />NUT IS POSSIBLE. IF NOT, REMOVE NUT AND INSTALL A THREADED COUPLER TO THE SAME <br />TIGHTNESS OF THE ORIGINAL NUT USING A TORQUE WRENCH AND APPLY LOAD. ANCHORS <br />TESTED WITH A HYDRAULIC JACK OR SPRING LOADED DEVICES SHALL MAINTAIN THE TEST LOAD <br />FOR A MINIMUM OF 15 SECONDS AND SHALL EXHIBIT NO DISCERNIBLE MOVEMENT DURING THE <br />TENSION TEST, E.G. AS EVIDENCED BY LOOSENING OF THE WASHER UNDER THE NUT. <br />f. TORQUE TESTS ACCEPTANCE: ANCHORS TESTED WITH A CALIBRATED TORQUE WRENCH MUST <br />ATTAIN THE MANUFACTURER'S RECOMMENDED TORQUE WITHIN 1/2 TURN OF THE NUT. <br />g. TEST EQUIPMENT IS TO BE CALIBRATED BY AN APPROVED TESTING LABORATORY IN <br />ACCORDANCE WITH STANDARD RECOGNIZED PROCEDURES. <br />h. FIELD TESTING SHALL BE DONE IN THE PRESENCE OF THE SPECIAL INSPECTOR OR INSPECTOR <br />OF RECORD. <br />i. TESTING SHOULD OCCUR 24 HOURS MINIMUM AFTER INSTALLATION OF THE SUBJECT ANCHORS. <br />j. INSPECTOR OF RECORDS SHALL REQUEST PROOF TEST VALUES FROM SEOR FOR EACH TYPE <br />OF POST-INSTALLED ANCHORS AT LEAST 48 HOURS PRIOR TO TESTING. <br />7. INSTALLERS PLACING HORIZONTALLY OR UPWARDLY INCLINED ADHESIVE ANCHORS SHALL BE CERTIFIED BY <br />ACI OR APPROVED EQUIVALENT. <br />8.RE-USE OF SCREW ANCHORS OR HOLES IS NOT PERMITTED. <br />POST-INSTALLED ANCHOR <br />POWDER ACTUATED FASTENERS (PAF) <br />EXISTING CONDITIONS <br />1. ALLOWABLE POWDER-ACTUATED FASTENERS (PAF) SHALL BE EITHER ONE OF THE FOLLOWING UNO: HILTI X-U <br />(ICC ESR-2269), SIMPSON POWER-DRIVEN FASTENERS (ICC ESR-2138), DEWALT CSI SPIRAL DRIVE PIN (ICC <br />ESR-2024) <br />2. INSTALL PER MANUFACTURER'S RECOMMENDED SPECIFICATIONS. <br />3. PROVIDE 0.08" THICK x 1.1" SQUARE OR 1.425" ROUND WASHERS FOR ALL POWDER-ACTUATED FASTENERS. <br />4. THE MINIMUM EMBEDMENT OF PAF INTO CONCRETE SHALL BE 1" UNO. <br />5. THE EMBEDMENT OF PAF INTO STEEL SHALL BE THAT REQUIRED BY PAF MANUFACTURER ICC ESR REPORT. <br />6. TESTING OF PAF IS NOT REQUIRED. <br />7. MAINTAIN ALL APPLICABLE EDGE DISTANCE AT CURBS AND SLAB EDGES PER MANUFACTURER'S ICC ESR <br />REPORT. <br />1. DEMOLITION WORK SHALL BE CONDUCTED IN SUCH A MANNER AS TO NOT DAMAGE EXISTING ELEMENTS THAT <br />ARE TO REMAIN IN THE FINISHED BUILDING. <br />2. VERIFY EXISTING BUILDING DIMENSIONS AND ELEVATIONS. NOTIFY AOR/SEOR OF ANY DISCREPANCIES BEFORE <br />PROCEEDING WITH WORK. <br />3. PROVIDE MEASURES NECESSARY TO PROTECT THE EXISTING STRUCTURE DURING DEMOLITION WORK. <br />PROTECTIVE MEASURES SHALL REMAIN IN PLACE UNTIL THE FINAL STRUCTURAL ELEMENTS ARE IN PLACE AND <br />ABLE TO SAFELY CARRY ALL IMPOSED EXISTING BUILDING LOADS. SUCH MEASURES INCLUDE, BUT NOT LIMITED <br />TO, BRACING AND SHORING. <br />4. EXISTING ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN IN THE FINISHED BUILDING SHALL BE PROTECTED <br />AS NECESSARY TO MINIMIZE DAMAGE DURING DEMOLITION WORK, ANY SUCH DAMAGE SHALL BE REPAIRED <br />AND/OR REPLACED AT NO ADDED COST. <br />5. ROUGHEN EXISTING CONCRETE SURFACES AGAINST WHICH FRESH CONCRETE IS TO BE PLACED TO A FULL <br />AMPLITUDE OF 1/4 INCH. <br />6. EXISTING CONCRETE ELEMENTS THAT ARE TO BE REMOVED BY CHIPPING SHALL BE STARTED WITH A 3/4 INCH <br />DEEP SAW CUT. CORNERS SHALL BE DRILLED TO PREVENT OVER-CUTTING. EXPOSED SAW CUT LINES SHALL BE <br />CLEAN, STRAIGHT AND SMOOTH. <br />7. EXISTING REINFORCING STEEL TO REMAIN SHALL BE CLEANED TO BARE METAL. <br />8. DEMOLISHED MATERIAL PLACED ON EXISTING FLOORS SHALL BE SPREAD OUT SUCH THAT IMPOSED LOADS DO <br />NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING WHERE OVERLOAD IS <br />ANTICIPATED. <br />DEMOLITION <br />1. DESIGN, FABRICATION AND ERECTION OF COLD-FORMED STEEL FRAMING SHALL CONFORM TO THE CURRENT <br />CBC ADOPTED EDITION OF THE SPECIFICATIONS AND STANDARD OF THE AMERICAN IRON AND STEEL INSTITUTE <br />(AISI), AS CONTAINED IN THE "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL <br />MEMBERS", INCLUDING ALL APPLICABLE AMENDMENTS. <br />2. ALL COLD-FORMED STEEL FRAMING SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY BRACING <br />SHALL BE INSTALLED AND LEFT IN PLACE UNTIL OTHER MEANS IS PROVIDED TO ADEQUATELY BRACE THE <br />STRUCTURE. ALL COLD-FORMED STEEL FRAMING SHALL BE BRACED AS REQUIRED BY SECTION D3 OF THE AISI <br />SPECIFICATION. <br />3. COLD-FORMED STEEL GRADES (ASTM A1003): <br />18 GA (43 MILS) OR THINNER.................................................................................................................GRADE 33 (Fy = 33 KSI) <br />16 GA (54 MILS) AND THICKER...............................................................................................................GRADE 50 (Fy = 50 KSI) <br />4. SUBMIT COLD-FORMED STEEL FRAMING SHOP DRAWINGS AND SPECIFICATIONS TO THE SEOR AND AOR FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />5. COLD-FORMED STEEL STUDS AND TRACKS ARE TO BE ATTACHED WITH SHEET METAL SCREWS (SMS) WITH <br />SIZES CALLED OUT ON THE DETAILS. PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHALL NOT BE <br />LESS THAN 3 EXPOSED THREADS. SCREWS SHALL BE DART SELF DRILLING SCREWS (ICC ESR-1408) OR ITW <br />BUILDEX TEKS <br />(ICC ESR-1976) AND SHALL BE INSTALLED AND TIGHTENED IN ACCORDANCE WITH SCREW MANUFACTURER'S <br />RECOMMENDATIONS. SHEET METAL SCREWS SHALL COMPLY WITH ASTM C1513, SELF-DRILLING AND TAPPING <br />TYPE, WITH PANCAKE FRAMER HEAD TYPE FOR #10 SMS AND HEX WASHER HEAD TYPE FOR #12 AND #14 (1/4"Ø) <br />SMS UNLESS NOTED OTHERWISE. <br />6. COLD-FORMED STUD MEMBERS SHALL BE UNPUNCHED WHERE USED FOR THE FOLLOWING: HEADERS AND <br />SILLS OF OPENINGS WIDER THAN 3'-0", AND BUILT-UP BOX AND BACK-TO-BACK SECTIONS. PUNCH-OUTS SHALL <br />BE LOCATED IN THE CENTER OF THE WEB WITH A MINIMUM SPACING OF 24"OC, HAVE A MAXIMUM WIDTH OF <br />HALF THE MEMBER DEPTH OR 2 1/2", WHICHEVER IS LESS, AND A MAXIMUM LENGTH OF 4 1/2". THE MINIMUM <br />DISTANCE BETWEEN THE END OF THE MEMBER AND THE NEAR EDGE OF THE PUNCH-OUT SHALL BE 12". <br />7. WELDING OF LIGHT GAGE STEEL SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) D1.3. <br />COLD-FORMED STEEL FRAMING <br />STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) <br />3300 IRVINE AVE. SUITE 245 <br />NEWPORT BEACH, CALIFORNIA 92660 <br />T:(949)862-8500 WWW.BJSCE.COM <br />JOB#: <br />No. 6250 <br />FFOHSIB <br />RYANW. <br />REGISTEREDPROFESSIONALENGINEER <br />STRUCTURALSTATEOFCALIFORNIA <br />DATE: <br />FOR BRANDOW & JOHNSTON <br />ISSUES AND REVISIONS <br />JOB NUMBER <br />SCALE <br />PROJECT <br />TEAM <br />All specifications, drawings, concepts, designs, arrangements, intellectual and written material represented herein constitute <br />unique and unpublished work of H. Hendy Associates and may not be copied, used by or disclosed to others without written <br />consent of H. Hendy Associates. <br /> 2023 H.HendyAssociatesc <br />DATE <br />240254 <br />12" = 1'-0" <br />04463.0000.24 <br />3080 S HARBOR BLVD <br />SANTA ANA, CA 92704 <br />GENERAL NOTES <br />S1.0.1 <br />MCGUFF <br />03/11/25 <br />SHEET LIST - TI <br />Sheet Number Sheet Name <br />S1.0.1 GENERAL NOTES <br />S1.0.2 GENERAL NOTES <br />S1.0.3 GENERAL NOTES <br />S1.1.1 TYPICAL CONCRETE DETAILS <br />S1.1.2 DETAILS <br />S1.1.3 DETAILS <br />S1.1.4 METAL STUD DETAILS <br />S1.1.5 METAL STUD DETAILS <br />S1.1.6 DETAILS <br />S1.2.1 FIRST FLOOR PLAN <br />S1.2.2 ROOF FRAMING PLAN <br />NO. DESCRIPTION DATE <br />PLAN CHECK SUBMITTAL 3/17/25 <br />3/17/2025