1. THE STRUCTURAL PRODUCT SCHEDULE INDICATES BASIS-OF-DESIGN MANUFACTURERS AND PRODUCTS FOR USE <br />ON THIS PROJECT. WHERE STRUCTURAL PRODUCTS ARE NOT EXPLICITLY NAMED IN THE CONSTRUCTION <br />DOCUMENTS, PROVIDE A LISTED PRODUCT. <br />2. PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER’S INSTALLATION INSTRUCTIONS AS AMENDED BY THE <br />REFERENCED PRODUCT ACCEPTANCE REPORTS (ICC, IAPMO, ETC.) FOR THE INTENDED USE. <br />3. AT CONTRACTOR’S OPTION, SUBSTITUTION REQUESTS MAY BE MADE FOR LIKE PRODUCTS WHICH DEMONSTRATE <br />QUALITIES THAT EQUAL OR EXCEED THOSE OF SPECIFIED PRODUCTS. <br />25675 <br />22668 <br />25469 <br />SHOTPIN <br />25897 <br />25741 <br />25808 <br />SCREW ANCHOR <br />TO CONCRETE <br />25964 <br />26028 <br />- <br />26035 <br />25960 <br />NA <br />ADHESIVE <br />ANCHOR TO <br />CONCRETE <br />NA <br />25831 <br />25891 <br />STRUCTURAL PRODUCT SCHEDULE <br />LARR <br />EXPANSION <br />ANCHOR TO <br />CONCRETE <br />ESR-2269 <br />ESR-1799 <br />ESR-2138 <br />ESR-3027 <br />ESR-2713 <br />ESR-2526 <br />ESR-3187 <br />ESR-3814 <br />ESR-4027 <br />ESR-3298 <br />ER-0263 <br />ESR-4057 <br />ESR-4266 <br />ESR-2502 <br />ESR-3037 <br />HILTI LOW-VELOCITY X-U <br />ITW RAMSET POWER-DRIVEN <br />SIMPSON POWDER-ACTUATED <br />HILTI KWIK HUS-EZ, -EZ 1 <br />SIMPSON TITEN HD <br />DEWALT/POWERS WEDGE-BOLT+ <br />HILTI HIT-HY 200 <br />HILTI HIT-RE 500-V3 <br />DEWALT/POWERS AC200+ <br />DEWALT/POWERS PURE110+ <br />SIMPSON AT-XP <br />SIMPSON SET-3G <br />HILTI KWIK BOLT TZ2 <br />DEWALT/POWERS-STUD+ SD2 <br />SIMPSON STRONG-BOLT 2 <br />ICC / IAPMOPRODUCTTYPE <br />PRODUCT SPECIFICATION <br />25620 <br />26050 <br />FIBER-REINFORCED <br />POLYMER (FRP) <br />SYSTEMS <br />REINFORCEMENT <br />BAR TERMINATOR <br />25342 <br />25347 <br />24507 <br />REINFORCEMENT <br />BAR COUPLER <br />02725 <br />25860 <br />WELDED STUD <br />25815 <br />25893 <br />ESR-2103 <br />ESR-2606 <br />ESR-2495 <br />ESR-2746 <br />ER-0129 <br />ESR-2856 <br />ESR-2907 <br />ESR-2746 <br />ER-0188 <br />FYFE TYFO FIBRWRAP <br />STRUCTURAL TECH V-WRAP <br />DAYTON BAR LOCK L-SERIES <br />HRC 500/510 XTENDER <br />LENTON <br />NELSON SHEAR CONNECTOR STUDS <br />NELSON D2L DEFORMED BAR ANCHOR <br />HRC 555/670 HEADED REINF. BARS <br />LENTON TERMINATOR <br />1. REINFORCING GRADES FOR CONCRETE OR MASONRY (UNO): <br />A. ALL BARS EXCEPT THOSE TO BE WELDED......................................................................................ASTM A615, GRADE 60 <br />B. TIES AND STIRRUPS ............................................................................................................................ASTM A615, GRADE 60 <br />C. WELDED WIRE FABRIC ..........................................................................................................................................ASTM A1064 <br />D. ALL BARS TO BE WELDED ..................................................................................................................ASTM A706, GRADE 60 <br />NOTE: ALL BARS SHALL BE DEFORMED. <br />2. MAINTAIN SPECIFIED CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF ALL REINFORCEMENT AS <br />FOLLOWS (UNO): <br />3. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH THE LATEST EDITION OF CONCRETE REINFORCING <br />STEEL INSTITUTE (CRSI) "MANUAL OF STANDARD PRACTICE". EACH REINFORCING BAR SHALL BE WIRED TO A <br />CROSS BAR AT A MAXIMUM SPACING OF 24"OC. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT <br />REINFORCING IN POSITIONS SHOWN ON THE PLANS. DO NOT USE WOOD OR BRICK TO SUPPORT REINFORCING. <br />4. SPLICES IN CONTINUOUS REINFORCEMENT AS USED IN WALLS, WALL FOOTINGS, ETC., SHALL HAVE A CLASS "B" <br />LAP (1'-6" MIN) AND THE SPLICES IN ADJACENT BARS SHALL BE NOT LESS THAN 5'-0" APART. VERTICAL WALL BARS <br />SHALL BE SPLICED AT OR NEAR FLOOR LINES. BARS MAY BE WIRED TOGETHER AT SPLICES OR LAPS EXCEPT FOR <br />TOP REINFORCING OF BEAMS AND SLABS OR WHERE SPECIFICALLY DETAILED TO BE SEPARATED. WELDED WIRE <br />FABRIC SHALL BE LAPPED 12" MINIMUM. ADJACENT WELDED WIRE FABRIC (WWF) SHEET SHALL BE LAPPED 12 <br />INCHES MINIMUM. <br />5. PROVISION FOR LAP SPLICES OR DOWELS SHALL BE PROVIDED ACROSS ALL CONSTRUCTION JOINTS AND SHALL <br />BE THE SAME GRADE, SIZE AND SPACING AS REINFORCING CONTINUING BEYOND UNLESS NOTED OTHERWISE. IN <br />LIEU OF SPLICES OR DOWELS, THE CONTRACTOR MAY SUBMIT FOR SEOR APPROVAL THE LOCATION AND <br />MANUFACTURER DATA OF FORMSAVERS OR COUPLERS PRIOR TO THEIR USE. <br />6. ALL DOWELS, ANCHOR BOLTS AND OTHER HARDWARE TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR <br />TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED <br />ITEMS SHALL BE PERFORMED DURING PLACEMENT OF CONCRETE. <br />7. BEND REINFORCING BARS COLD. <br />8. REINFORCING BARS SHALL BE KEPT CLEAN AND FREE OF RUST. <br />9. DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE <br />MAIN REINFORCING UNO. <br />10. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN THE FINAL IN PLACE INSPECTION IS <br />MADE. <br />11. CHAIRS OR SPACERS FOR REINFORCING SHALL BE PLASTIC WHEN RESTING ON EXPOSED SURFACES. <br />12. WHERE LONGITUDINAL REINFORCING BARS ARE PLACED IN 2 OR MORE LAYERS, BARS IN THE UPPER LAYERS <br />SHALL BE PLACED DIRECTLY ABOVE BARS IN THE BOTTOM LAYER. <br />13. ALL BENDS WITHIN STIRRUPS, HOOPS, AND CROSS-TIES SHALL ENGAGE A LONGITUDINAL BAR. PROVIDE #4 <br />SPACER BAR WHERE A LONGITUDINAL BAR IS NOT SPECIFICALLY DETAILED. <br />14. WELDING OF REINFORCING BARS SHALL BE ASTM A706 AND BE PERFORMED PER AMERICAN WELDING SOCIETY <br />(AWS) D1.4 USING MATCHING FILLER MATERIALS PER AWS TABLE 7.1, MINIMUM E80XX ELECTRODES. <br />15. THE FOLLOWING REINFORCEMENT SHALL COMPLY WITH ASTM A706: <br />A. VERTICAL REINFORCEMENT AT INTERSECTIONS AND ENDS OF CONCRETE WALLS ENCLOSED IN TIES OR <br />STIRRUPS (BOUNDARY ELEMENTS). <br />B. LONGITUDINAL MOMENT FRAME BEAMS AND COLUMNS REINFORCING BARS. <br />C. WELDED REINFORCING. <br />SPECIFIED CONCRETE COVER FOR CAST-IN-PLACE <br />NON-PRESTRESSED CONCRETE MEMBERS <br />CONCRETE EXPOSURE MEMBER REINFORCEMENT <br />CAST AGAINST AND PERMANENTLY <br />IN CONTACT WITH GROUND ALL ALL <br />SPECIFIED <br />COVER (IN) <br />3 <br />EXPOSED TO WEATHER OR <br />IN CONTACT WITH GROUND ALL <br />NO. 6 THROUGH NO. 18 BARS 2 <br />NO. 5 BAR, W31 OR D31 WIRE, <br />AND SMALLER 1 1/2 <br />NOT EXPOSED TO WEATHER OR <br />IN CONTACT WITH GROUND <br />SLABS, JOISTS, <br />AND WALLS <br />NO. 14 AND NO.18 BARS <br />NO. 11 BAR AND SMALLER <br />1 1/2 <br />3/4 <br />BEAMS, COLUMNS, <br />PEDESTALS, <br />AND TENSION TIES <br />PRIMARY REINFORCEMENT, <br />STIRRUPS, TIES, <br />SPIRALS, AND HOOPS <br />1 1/2 <br />SPECIFIED CONCRETE COVER FOR CAST-IN-PLACE <br />PRESTRESSED CONCRETE MEMBERS <br />CONCRETE EXPOSURE MEMBER REINFORCEMENT <br />CAST AGAINST AND PERMANENTLY <br />IN CONTACT WITH GROUND ALL ALL <br />SPECIFIED <br />COVER (IN) <br />3 <br />EXPOSED TO WEATHER OR <br />IN CONTACT WITH GROUND <br />ALL 1 <br />ALL 1 1/2 <br />NOT EXPOSED TO WEATHER OR <br />IN CONTACT WITH GROUND <br />SLABS, JOISTS, <br />AND WALLS ALL <br />PRIMARY REINFORCEMENT <br />3/4 <br />1 1/2 <br />BEAMS, COLUMNS, <br />PEDESTALS, <br />AND TENSION TIES STIRRUPS, TIES, <br />SPIRALS, AND HOOPS 1 <br />SLABS, JOISTS, <br />AND WALLS <br />ALL OTHER <br />REINFORCING STEEL <br />CONCRETE <br />TYPE <br />MAX <br />AGGREGATE <br />SIZE <br />MIN COMPRESSIVE <br />STRENGTH AT <br />28 DAYS (f'c) <br />LOCATION MAX W/CM <br />RATIO <br />SLAB-ON-GRADE 4,000 PSI 1"0.45 <br />CONCRETE CURB FOR <br />ROOF TOP AHU 5,000 PSI 3/4"N/A <br />ALL OTHER STRUCTURAL <br />CONCRETE (UNO)3,000 PSI 1"0.50 <br />NORMAL-WEIGHT <br />LIGHT-WEIGHT <br />NORMAL-WEIGHT <br />GRADE BEAM 5,000 PSI <br />FOUNDATIONS (UNO)5,000 PSI NORMAL-WEIGHT 1 1/2"0.50 <br />3/4"0.50NORMAL-WEIGHT <br />3. STRUCTURAL CONCRETE SHALL CONFORM TO PROJECT SPECIFICATIONS AND THE FOLLOWING REQUIREMENTS: <br />A. MAXIMUM DRY UNIT WEIGHT OF LIGHT-WEIGHT CONCRETE SHALL NOT EXCEED 110 ± 3 PCF (PER ASTM C138). <br />MAXIMUM DRY UNIT WEIGHT OF NORMAL-WEIGHT CONCRETE SHALL NOT EXCEED 150 ± 3 PCF. <br />B. WHEN PLASTICIZER OR WATER REDUCER IS USED, MAXIMUM SLUMP SHALL BE 4" PRIOR TO ADMIXTURE AND 8" <br />INCLUDING ADMIXTURE AT THE POINT OF DISCHARGE. IN THE ABSENCE OF PLASTICIZER AND WATER REDUCER, <br />SLUMP AT THE POINT OF DISCHARGE SHALL NOT EXCEED 4" IN FLATWORK AND 5" ELSEWHERE. <br />C. W/CM INDICATES WATER TO CEMENTITOUS MATERIALS RATIO BASED ON ALL CEMENTITIOUS AND <br />SUPPLEMENTARY CEMENTITIOUS MATERIALS IN THE CONCRETE MIXTURE. THE MAXIMUM WATER-CEMENTITOUS <br />MATERIAL RATIO (W/CM) FOR SLABS-ON-GRADE AND ALL OTHER SLABS RECEIVING ADHERED FLOORING <br />FINISHES SENSITIVE TO MOISTURE SHALL NOT EXCEED 0.45, WATER-CEMENTITOUS MATERIAL RATIO (W/CM) FOR <br />CONCRETE ON METAL DECK WITH WITH VENTED FLUTES MAY BE 0.50, UNO. <br />D. SLABS ON GRADE, TOPPING SLABS, AND ELEVATED CONCRETE FLOORS (INCLUDING CONCRETE ON METAL <br />DECK) SHALL HAVE A MAXIMUM SHRINKAGE RATE OF 0.045% AT 28 DAYS PER ASTM C 157. SUBMIT SHRINKAGE <br />TEST RESULTS AS PART OF CONCRETE MIX DESIGN FOR REVIEW AND APPROVAL BY SEOR. <br />E. MAXIMUM AGGREGATE SIZE SHALL BE AS NOTED IN TABLE ABOVE, BUT NOT LARGER THAN THE LEAST OF ONE- <br />FIFTH THE NARROWEST DIMENSION BETWEEN SIDES OF FORMS, ONE-THIRD THE DEPTH OF SLAB, AND THREE- <br />FOURTH THE MINIMUM SPECIFIED CLEAR SPACING BETWEEN INDIVIDUAL REINFORCING BARS OR TENDONS. <br />F. AGGREGATE GRADATION OF 3/8" MAXIMUM (PEA GRAVEL) SHALL NOT BE USED WHERE FINISHED CONCRETE <br />SURFACE IS EXPOSED TO VIEW. <br />G. FOR CONCRETE EXPOSURE CATEGORIES AND CLASSES REFER TO TABLE 19.3.1.1 OF ACI 318. CONCRETE <br />MIXTURES SHALL CONFORM TO THE MOST RESTRICTIVE REQUIREMENTS OF TABLE 19.3.2.1 OF ACI 318 BASE ON <br />EXPOSURE CLASSES ASSIGNED. <br />H. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE FINISHES SHALL BE COMPATIBLE WITH TILE AND <br />ADHESIVES OR GROUTS IN ACCORDANCE WITH MANUFACTURER'S DATA. <br />I. MAXIMUM W/CM LIMITS DO NOT APPLY TO LIGHTWEIGHT CONCRETE. <br />J. AIR CONTENT OF CONCRETE MIXTURE SHALL COMPLY WITH R EQUIREMENTS OF SECTION 19.3.3 OF ACI 318. <br />K. FOR EXPOSURE CLASS S1, S2 OR S3, MINERAL FILLERS DERIVED FROM CARBONATE AGGREGATE ARE <br />PROHIBITED. <br />4. CONCRETE MIX PROPORTIONING SHALL BE BASED ON FIELD DATA AND/OR LABORATORY TRIAL MIXES AS REQUIRED <br />BY CBC, ACI 318, ACI 214R AND ACI 301. THE CONCRETE SHALL BE WORKABLE AND MEET DURABILITY AND <br />STRENGTH REQUIREMENT OF THE CODE. SUBMIT CONCRETE MIX PROPORTIONING DATA INCLUDING HISTORICAL <br />STRENGTH RECORDS AND/OR LABORATORY TRIAL MIXES FOR EACH TYPE AND COMPRESSIVE STRENGTH <br />PREPARED, SIGNED AND SEALED BY A CALIFORNIA LICENSED CIVIL OR STRUCTURAL ENGINEER FOR REVIEW AND <br />APPROVAL BY AOR/SEOR AND DSA'S LABORATORY ACCEPTANCE PROGRAM (LEA) PRIOR TO CONCRETE <br />PLACEMENT. <br />5. AGGREGATES IN NORMAL-WEIGHT CONCRETE SHALL BE HARD ROCK AND CONFORM TO ASTM C33. AGGREGATES IN <br />LIGHT-WEIGHT CONCRETE SHALL BE EXPANDED SHALE AND CONFORM TO ASTM C330. FOR CONCRETE IDENTIFIED <br />AS BEING EXPOSED TO WATER IN SERVICE, EVIDENCE SHALL BE SUBMITTED THAT AGGREGATES IN THE CONCRETE <br />MIXTURE ARE NOT ALKALI-SILICA REACTIVE OR ALKALI-CARBONATE REACTIVE. <br />6. CEMENTITIOUS MATERIALS USED IN CONCRETE MIXTURE SHALL COMPLY WITH TABLE 26.4.1.1.1(a) AND TABLE <br />19.3.2.1 OF ACI 318. MILL TESTS WITH CERTIFICATES OF COMPLIANCE SHALL BE SUBMITTED. FLY ASH OR OTHER <br />POZZOLANS CONFORMING TO ASTM C618 CLASS F MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND <br />CEMENT BY WEIGHT IF THE MIX DESIGN IS PROPORTIONED BY FIELD EXPERIENCE OR TRIAL MIXTURES. WHERE <br />CONCRETE IS SUBJECT TO CYCLES OF FREEZING AND THAWING AND APPLICATION OF DEICING CHEMICALS, <br />SUPPLEMENTARY CEMENTITIOUS MATERIALS SHALL NOT EXCEED THE MAXIMUM PERCENTAGES ALLOWED IN TABLE <br />26.4.2.2(b) AND SECTION 26.4.2.2 OF ACI 318. <br />7. READY-MIXED CONCRETE SHALL BE BATCHED, MIXED AND DELIVERE D IN CONFORMANCE WITH ASTM C94. <br />8. ADMIXTURES SHALL CONFORM WITH THE FOLLOWING REQUIREMENTS: WATER REDUCER AND SETTING TIME <br />MODIFICATION IN CONFORMANCE WITH ASTM C494 (TYPE F OR G) SUPERPLASTICIZER IN CONFORMANCE WITH ASTM <br />C1017 (TYPE I OR II). AIR ENTRAINMENT IN CONFORMANCE WITH ASTM C260. INHIBITING CHLORIDE-INDUCED <br />CORROSION IN CONFORMANCE WITH ASTM C1582. <br />9. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL OR CAUSE SEGREGATION OF AGGREGATES. IN <br />SUCH CASES, HOPPERS AND VERTICAL CHUTES OR TRUNKS SHALL BE USED. CHUTES OR TRUNKS SHALL BE OF <br />VARIABLE LENGTHS SO THAT FREE UNCONFINED FALL OF CONCRETE SHALL NOT EXCEED SIX FEET. A SUFFICIENT <br />NUMBER OF CHUTES OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETE IS KEPT LEVEL AT ALL TIMES. <br />10. CONSTRUCTION JOINTS SHALL BE CLEANED AND ROUGHENED BY REMOVING THE ENTIRE SURFACE TO EXPOSE <br />CLEAN AGGREGATE SOLIDLY EMBEDDED IN THE MORTAR MATRIX. SEE PLANS AND DETAILS FOR LOCATION AND <br />TYPE OF CONSTRUCTION JOINT. LOCATIONS OF ADDITIONAL CONSTRUCTION JOINTS NOT SHOWN ON THESE PLANS <br />SHALL BE SUBMITTED TO SEOR FOR APPROVAL PRIOR TO CONCRETE PLACEMENT. <br />11. LEAN CONCRETE, WHERE SPECIFICALLY INDICATED, SHALL CONTAIN 2 SACKS OF CEMENT PER CUBIC YARD OF <br />CONCRETE. <br />12. DRYPACK OR NON-SHRINK GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI, AND <br />CONSIST OF MASTERFLOW 713, EUCON NS GROUT, SIKA GROUT 212, OR APPROVED EQUAL. FOR THICK GROUT <br />LAYERS FOLLOW MANUFACTURER'S GUIDELINES TO ATTAIN THE REQUIRED STRENGTH, WHICH MAY INCLUDE THE <br />ADDITION OF PEA FINE AGGREGATES. FOR BASE PLATES LARGER THAN 6 SQUARE FEET, USE HI-FLOW GROUT OR <br />MASTERFLOW 928. <br />13. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIX SHALL BE CLEAN AND <br />POTABLE. <br />14. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION, CONCRETE MUST REACH AN UNCONFINED <br />COMPRESSION STRENGTH OF MINIMUM 75% f'c AS DETERMINED BY TESTING OR PREVIOUSLY DOCUMENTED DATA <br />FOR THE MIX DESIGN USED UNDER SIMILAR CONDITIONS, AND MUST BE ALLOWED TO CURE FOR A MINIMUM OF 3 <br />DAYS. <br />15. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION FOR A MINIMUM OF 7 DAYS <br />AFTER PLACEMENT UNLESS OTHERWISE ACCEPTED BY SEOR. <br />16. SEE ARCHITECTURAL DRAWINGS FOR WALL OPENING SIZES AND LOCATIONS, WALL OFFSETS, CHAMFERS, KERFS, <br />DRIPS AND FOR EXTENT OF DEPRESSIONS, RAMPS, ETC. <br />17. PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND FOOTINGS WHERE SHOWN ON THESE <br />DRAWINGS. CORING IS NOT PERMITTED WITHOUT PRIOR APPROVAL BY THE SEOR. <br />18. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE FORMED WITH 3/4" CHAMFER OR 1/2" <br />RADIUS TOOLED EDGE, UNO. <br />19. SUBMIT SHOP DRAWINGS INDICATING LOCATIONS OF CONCRETE CONSTRUCTION JOINTS TO SEOR FOR REVIEW <br />AND APPROVAL PRIOR TO CONCRETE PLACEMENT. LOCATE CONSTRUCTION JOINTS TO MINIMIZE EFFECTS OF <br />SHRINKAGE AND AT POINTS OF LOW STRESS. HORIZONTAL CONSTRUCTION JOINTS ARE NOT PERMITTED IN BEAMS <br />AND SLABS UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS OR APPROVED BY SEOR PRIOR TO CONCRETE <br />PLACEMENT. <br />20. PRIOR TO PLACING CONCRETE, REINFORCING BARS (INCLUDING WELDED WIRE REINFORCEMENT), EMBEDDED <br />PLATES, ANCHOR BOLTS, AND OTHER CONCRETE EMBEDMENTS SHALL BE WELL SECURED IN POSITION. <br />21. CONCRETE PLACEMENT SHALL CONFORM TO ACI 304 AND CONTRACT DOCUMENTS. INTENTIONALLY ROUGHEN ALL <br />PREVIOUSLY HARDENED CONCRETE SURFACES TO A FULL AMPLITUDE OF 1/4-INCH AGAINST WHICH FRESH <br />CONCRETE IS PLACED. <br />22. CURING COMPOUNDS, SEALERS, HARDENERS, ETC., USED ON CONCRETE THAT RECEIVES A FINISH SHALL BE <br />APPROVED BY THE ARCHITECT BEFORE USE. <br />1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH THE CURRENT CBC ADOPTED EDITION OF <br />ACI 318, ACI 301, AND PROJECT SPECIFICATIONS. <br />2. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA UNLESS NOTED OTHERWISE: <br />CAST-IN-PLACE CONCRETE <br />CONCRETE OVER METAL <br />DECK, CURBS & PADS 4,000 PSI 3/4"N/ALIGHT-WEIGHT <br />CONCRETE WALLS/ <br />BASEMENT WALLS 4,000 PSI 3/4"0.50NORMAL-WEIGHT <br />CONCRETE PEDESTALS 4,000 PSI 3/4"0.50NORMAL-WEIGHT <br />EXPOSURE CATEGORIES <br />AND CLASSES <br />F0 S0 W2 C1 <br />F0 S0 W0 C0 <br />F0 S0 W1 C1 <br />F0 S0 W0 C0 <br />F0 S0 W1 C0 <br />F0 S0 W0 C0 <br />F0 S0 W0 C0 <br />F0 S0 W0 C0 <br />1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE CURRENT CBC ADOPTED <br />EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "SPECIFICATION FOR STRUCTURAL STEEL <br />BUILDINGS" (ANSI/AISC 360) AND AISC "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS" (ANSI/AISC 341). <br />2. ALL WORK SHALL BE IN CONFORMANCE WITH ANY AND ALL TESTING, INSPECTION, QUALIFICATION, AND QUALITY <br />ASSURANCE PROVISIONS AS REQUIRED BY THE CALIFORNIA BUILDING CODE AND ANY APPLICABLE STANDARDS <br />(LATEST ADOPTED EDITION OF CURRENT CBC). <br />• ANSI/AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" <br />• ANSI/AISC 341 "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS" <br />• AWS D1.1 "STRUCTURAL WELDING CODE -STEEL" <br />• AWS D1.8 "STRUCTURAL WELDING CODE -SEISMIC SUPPLEMENT" <br />• RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS" <br />• ANSI/AISC 303 " CODE OF STANDARD PRACTICE FOR STEEL BUILDING AND BRIDGES" <br />• ANSI/AISC 358 " PREQUALIFIED CONNECTIONS FOR SPECIAL AND INTERMEDIATE STEEL MOMENT FRAMES FOR <br />SEISMIC APPLICATIONS" <br />CONFORMANCE TO SUPPLEMENTS TO THESE STANDARDS, IF PUBLISHED ON OR BEFORE THE DATE OF PERMIT <br />ISSUANCE, IS ALSO REQUIRED. ALTHOUGH THESE CONTRACT DOCUMENTS INCLUDE GENERAL REFERENCES TO <br />CODES AND STANDARDS, AND REFERENCES TO OR INCLUSIONS OF SPECIFIED PROVISIONS, OMISSIONS OF ANY <br />APPLICABLE CODE, STANDARD, OR PROVISION DOES NOT RELIEVE THE GENERAL CONTRACTOR FROM <br />COMPLIANCE TO THE APPLICABLE REQUIREMENTS. COORDINATION OF QUALITY CONTROL AND QUALITY <br />ASSURANCE IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. <br />3. STRUCTURAL STEEL MATERIAL SHALL CONFORM TO THE FOLLOWING ASTM STANDARDS, UNO: <br />WIDE FLANGE SECTIONS....................................................................................................................................................ASTM A992 <br />PLATE, ANGLE, CHANNEL & TEES............................................................................................................................ASTM A36 (UNO) <br />PLATES USED IN SFRS..........................................................................................................................................ASTM A572 (50 KSI) <br />SQUARE OR RECTANGULAR HSS....................................................................................................ASTM A500, GRADE C (50 KSI) <br />ROUND HSS..........................................................................................................................................ASTM A500, GRADE C (46 KSI) <br />PIPES........................................................................................................................................................ASTM A53, GRADE B (35 KSI) <br />4. HEADED STUD ANCHORS (SHEAR CONNECTOR STUDS ) IN CONCRETE SHALL BE NELSON TYPE S3L (ICC ESR-2856) <br />OR AN APPROVED EQUAL, AND SHALL CONFORM TO ASTM A29-12, GRADES 1010 THROUGH 1020, COLD-DRAWN <br />STEEL, WITH A MINIMUM ULTIMATE TENSILE STRENGTH OF 65 KSI. HEADED STUDS WELDING TEST AND INSPECTION <br />SHALL CONFORM TO AWS D1.1, CHAPTER 7. <br />5. FABRICATOR SHALL BE LICENSED IN CONFORMANCE WITH THE BUILDIND CODE AND IN ACCORDANCE WITH THE <br />AUTHORITY HAVING JURISDICTION. <br />6. ALL STEEL NOT ENCASED IN CONCRETE, MASONRY, OR FIREPROOFING SHALL BE SHOP PRIMED AND PAINTED PER <br />SPECIFICATIONS, EXCEPT FOR TOP FLANGE OF BEAMS SUPPORTING METAL DECK. ANY ABRASIONS OR UNPAINTED <br />AREAS SHALL BE REPAIRED AFTER ERECTION. <br />7. ALL STRUCTURAL STEEL AND MISCELLANEOUS STEEL PERMANENTLY EXPOSED TO WEATHER OR GROUND SHALL <br />BE HOT-DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A385 UNLESS A WEATHER PROOF <br />COATING IS SPECIFIED BY THE ARCHITECT, UNO. STAINLESS AND WEATHERING STEELS, WHERE SPECIFIED, ARE <br />EXEMPT FROM THIS REQUIREMENT. GALVANIZED SURFACES SHALL BE PROTECTED DURING CONSTRUCTION AND <br />SHALL BE REPAIRED AS NECESSARY. BOLTED CONNECTIONS PERMANENTLY EXPOSED TO WEATHER SHALL USE <br />GALVANIZED HIGH-STRENGTH BOLTS ASTM F3125 GRADE A325 TYPE 1 OR GALVANIZED ASTM F3125 GRADE F1852 <br />TYPE 1. WELDED CONNECTIONS PERMANENTLY EXPOSED TO WEATHER SHALL RECEIVE ZINC RICH TOUCH UP PAINT <br />(COORDINATE WITH AOR). STEEL IN CONTACT WITH TREADED WOOD SHALL BE HOT DIP GALVANIZED, UNO. <br />8. PROVIDE UPWARD CAMBER FOR ALL BEAMS SPECIFIED TO HAVE CAMBER. AMOUNT MEASURES IN THE FIELD PRIOR <br />TO ERECTION SHALL NOT DEVIATE MORE THAN ALLOWED BY AISC SPECIFICATIONS. BEAMS WITHOUT SPECIFIED <br />CAMBER SHALL BE FABRICATED SO THAT ANY MINOR CAMBER DUE TO ROLLING SHALL BE UPWARD AFTER <br />ERECTION. <br />9. COMPOSITE STRUCTURAL BEAMS AND GIRDERS ARE DESIGNED FOR UNSHORED CONSTRUCTION UNLESS NOTED <br />OTHERWISE. <br />10. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY WITH AISC "CODE OF STANDARD <br />PRACTICE FOR STEEL BUILDINGS AND BRIDGES" (ANSI/AISC 303), SECTION 10. <br />11. SEE ARCHITECTURAL DRAWINGS FOR NAILER HOLES, WELDED STUDS OR OTHER ITEMS NOT SHOWN IN <br />STRUCTURAL DRAWINGS. <br />12. FOR STEEL EMBEDDED IN CONCRETE OR MASONRY WHICH WILL INTERFERE WITH CONTINUOUS REINFORCING <br />BARS, REQUEST CLARIFICATION FROM THE SEOR WHETHER TO PROVIDE HOLES FOR PASSAGE. DO NOT CUT HOLES <br />IN STRUCTURAL STEEL WITHOUT PRIOR APPROVAL OF SEOR. <br />13. DO NOT CUT HOLES IN STRUCTURAL STEEL WITHOUT WRITTEN APPROVAL OF THE SEOR. <br />14. PLACE NON-SHRINK OR DRYPACK GROUT UNDER ALL BASE PLATES AND ALLOW TO CURE BEFORE APPLYING ANY <br />LOAD. <br />15. ALL STRUCTURAL STEEL SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY BRACING SHALL BE INSTALLED <br />AND SHALL BE LEFT IN PLACE UNTIL OTHER MEANS IS PROVIDED TO ADEQUATELY BRACE THE STRUCTURE. <br />16. SUBMIT SHOP DRAWINGS TO AOR AND SEOR FOR REVIEW AND, UPON REQUEST, TO GOVERNING CODE AUTHORITY. <br />INDICATE AN ERECTION SEQUENCE OF WELDING TO MINIMIZE LOCKED-UP STRESSES OR DISTORTION FOR MOMENT- <br />RESISTING STEEL FRAMES. <br />17. HOURLY FIRE RESISTIVE REQUIREMENTS FOR STRUCTURAL STEEL MEMBERS SHALL BE DETERMINED PER CBC <br />TABLE 601. REFER TO ARCHITECTURAL DRAWINGS FOR BUILDING TYPES OF CONSTRUCTION AND FIREPROOFING <br />MATERIALS. <br />18. MECHANICAL CONTRACTOR TO VERIFY ALL MECHANICAL UNIT LOCATIONS, SIZES AND OPENINGS. <br />NOTIFY SEOR OF ANY DISCREPANCY PRIOR TO START OF WORK. <br />19. STEEL FABRICATOR TO LOCATE ALL BEAMS BASED ON INFORMATION FROM MECHANICAL CONTRACTOR AND <br />SUBMIT STEEL BEAM LOCATION TO THE AOR AND SEOR FOR REVIEW AND APPROVAL. <br />20. REFER TO "HIGH-STRENGTH BOLT" , "WELDING" AND "STEEL IN SEISMIC FORCE RESISTING SYSTEM (SFRS)" FOR <br />RELATED SPECIFIC REQUIREMENTS AND NOTES FOR ADDITIONAL INFORMATION. <br />21. THE USE OF ROLLED STEEL SECTIONS AND/OR BOLTS MANUFACTURED OUTSIDE OF THE UNITED STATES WILL <br />REQUIRE VERIFICATION THAT THE PRODUCTS COMPLY WITH APPLICABLE ASTM STANDARDS. MILL CERTIFICATES <br />WILL BE REQUIRED FOR ALL STEEL. STEEL GRADES OTHER THAN ASTM A36 WILL REQUIRE TESTING BY AN <br />APPROVED LABORATORY. ALL FOREIGN BOLTS MUST BE APPROVED BY COUNTY OF LOS ANGELES BUILDING AND <br />SAFETY PRIOR TO THEIR USE. <br />STRUCTURAL STEEL <br />1. SEE "STRUCTURAL STEEL" NOTES FOR ADDITIONAL INFORMATION. <br />2. JOINT ASSEMBLIES USING HIGH-STRENGTH BOLTS SHALL BE IN ACCORDANCE WITH THE CURRENT CBC <br />ADOPTED EDITION OF THE "AISC (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH <br />BOLTS". <br />3. HIGH-STRENGTH BOLTS, NUTS AND WASHERS SHALL CONFORM TO THE "SPECIFICATION FOR STRUCTURAL <br />JOINTS USING HIGH-STRENGTH BOLTS" PREPARED BY RCSC AND AS AMENDED BY CBC SECTION 2204. <br />PROVIDE STANDARD-SIZE HOLES UNLESS NOTED OTHERWISE. <br />4. ALL BOLTS SHALL BE HIGH-STRENGTH BOLTS, UNLESS NOTED OTHERWISE. <br />5. BOLTS WITH UPSET THREADS ARE NOT ALLOWED UNLESS NOTED OTHERWISE. <br />6. BOLTED CONNECTIONS SHALL CONFORM TO THE FOLLOWING ASTM STANDARDS UNO: <br />MACHINE BOLTS (MB)..............................................................................................................................................ASTM A307 <br />HIGH-STRENGTH BOLTS (TYP UNO ON DRAWINGS)......................................ASTM F3125 GRADE A325 (TYPE 1) UNO <br />HIGH-STRENGTH BOLTS (TWIST-OFF-TYPE TENSION-CONTROLLED)................ASTM F3125 GRADE F1852 (TYPE 1) <br />UNO THREADED RODS USED AS ANCHOR BOLTS...........................................................ASTM F1554, GRADE 36 (UNO) <br />THREADED RODS USED IN SFRS...................................ASTM F1554, GRADE 55 (WELDABLE WITH SUPPLEMENT S1) <br />7. PAINT SHALL NOT BE PERMITTED ON CONTACT SURFACES UNLESS NOTED OTHERWISE. CONTACT SURFACES <br />OF BOLTED PARTS SHALL BE DESCALED AND FREE OF DIRT, OIL, BURRS, PITS, AND OTHER DEFECTS WHICH <br />PREVENT SOLID SEATING OF PARTS. <br />8. ALL HIGH-STRENGTH BOLTS SHALL BE TIGHTENED TO SNUG-TIGHT CONDITION USING ASTM F3125 GRADE <br />A325 BEARING TYPE BOLTS WITH THREADS INCLUDED IN SHEAR PLANE UNLESS NOTED OTHERWISE. <br />9. PROVIDE SLIP-CRITICAL CONNECTIONS IN SEISMIC FORCE RESISTANCE SYSTEM (SFRS). SLIP-CRITICAL <br />BOLTS SHALL HAVE CLASS "A" FAYING SURFACES. SLIP-CRITICAL JOINT ASSEMBLIES SHALL BE FULLY PRE- <br />TENSIONED BY TURN-OF-NUT TIGHTENING, TENSION CONTROL CALIBRATED WRENCH TIGHTENING, TWIST- <br />OFF BOLTS CONFORMING TO ASTM F3125 GRADE F1852, OR BY DIRECT TENSION INDICATOR TIGHTENING <br />CONFORMING TO ASTM F959. <br />(a) HIGH-STRENGTH BOLTS: <br />STRUCTURAL+CIVIL ENGINEERS (B&J HBK, INC.) <br />3300 IRVINE AVE. SUITE 245 <br />NEWPORT BEACH, CALIFORNIA 92660 <br />T:(949)862-8500 WWW.BJSCE.COM <br />JOB#: <br />No. 6250 <br />FFOHSIB <br />RYANW. <br />REGISTEREDPROFESSIONALENGINEER <br />STRUCTURALSTATEOFCALIFORNIA <br />DATE: <br />FOR BRANDOW & JOHNSTON <br />ISSUES AND REVISIONS <br />JOB NUMBER <br />SCALE <br />PROJECT <br />TEAM <br />All specifications, drawings, concepts, designs, arrangements, intellectual and written material represented herein constitute <br />unique and unpublished work of H. Hendy Associates and may not be copied, used by or disclosed to others without written <br />consent of H. Hendy Associates. <br /> 2023 H.HendyAssociatesc <br />DATE <br />240254 <br />12" = 1'-0" <br />04463.0000.24 <br />3080 S HARBOR BLVD <br />SANTA ANA, CA 92704 <br />GENERAL NOTES <br />S1.0.2 <br />MCGUFF <br />03/11/25 <br />NO. DESCRIPTION DATE <br />PLAN CHECK SUBMITTAL 3/17/25 <br />3/17/2025