Laserfiche WebLink
© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />EXP: 12/31/2025 <br />10/4/2024 2:11:34 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/228011-04_3RD-B_MECH_R20.rvt <br />R2.M0.5 <br />ENERGY CALCULATIONS <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />1 06.17.2024 REVISION TO PERMIT <br />2 10.04.2024 REVISION TO PERMIT REVIEW <br />2 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />This document is used to demonstrate compliance for mechanical systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive <br />path outlined in §140.4, or §141.0(b)2  for alterations. <br />Project Name: 3rd & Broadway West Building Report Page: (Page 1 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />A. GENERAL INFORMATION <br />01 Project Location (city)Santa Ana 04 Total Conditioned Floor Area 176200 <br />02 Climate Zone 8 05 Total Unconditioned Floor Area 205000 <br />03 Occupancy Types Within Project:06 # of Stories (Habitable Above Grade)10 <br />Office (B)Retail (M)Non-refrigerated Warehouse (S) <br />Hotel/ Motel Guest Rooms (R-1)School (E)Healthcare Facility (I) <br />High-Rise Residential (R-2/R-3)Relocatable Class Bldg (E)Other (Write In) <br />B. PROJECT SCOPE <br />This table Includes mechanical systems or components that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in <br />§140.4, or §141.0(b)2  for alterations. <br />01 02 03 <br />Air System(s)Wet System Components Dry System Components <br />Heating Air System Water Economizer Air Economizer <br />Cooling Air System Pumps Electric Resistance Heat <br />Mechanical Controls System Piping Fan Systems <br />Mechanical Controls (existing to remain, altered <br />or new)Cooling Towers Ductwork (existing to remain, altered or new) <br />Chillers Ventilation <br />Boilers Zonal Systems/ Terminal Boxes <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 3 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) <br />This table is used to demonstrate compliance for mechanical equipment with mandatory requirements found in §110.1  and §110.2(a)  and prescriptive requirements found in §140.4(a), <br />§140.4(b)  and §140.4(k)  or §141.0(b)2  for alterations. <br />Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters) <br />01 02 03 04 05 06 07 08 09 10 11 <br />Name or Item <br />Tag <br />Equipment Category per <br />Tables 110.2 <br />Equipment Type per Tables 110.2 / Title <br />20 <br />Smallest Size <br />Available1 <br />§140.4(a)  <br />Equipment Sizing per Mechanical Schedule (kBtu/h) <br />§140.4 (a&b) <br />Heating Output2,3 Cooling Output2,3 Load Calculations3,4 <br />Per Design <br />(kBtu/h) <br />Rated <br />(kBtu/h) <br />Supp. <br />Heating <br />Output <br />(kBtu/h) <br />Sensible <br />Per Design <br />(kBtu/h) <br />Rated <br />(kBtu/h) <br />Total <br />Heating <br />Load <br />(kBtu/h) <br />Total <br />Sensible <br />Cooling <br />Load <br />(kBtu/h) <br />ACCU-R01 Variable Refrigerant Flow VRF heat pump, air cooled Yes 189 189 0 168 168 88.3 159.6 <br />ACCU-R03C Variable Refrigerant Flow VRF heat pump, air cooled Yes 81 81 0 72 72 32.8 55.9 <br />ACCU-R07A Variable Refrigerant Flow VRF heat pump, air cooled Yes 216 216 0 192 192 75.9 76.5 <br />ACCU-R07B Variable Refrigerant Flow VRF heat pump, air cooled Yes 162 162 0 216 216 120.9 137.1 <br />ACCU-R08A <br />THRU <br />ACCU-R14A <br />(TYP.) <br />Variable Refrigerant Flow VRF heat pump, air cooled Yes 162 162 0 144 144 100.4 134 <br />ACCU-R08B <br />THRU <br />ACCU-R14B <br />(TYP.) <br />Variable Refrigerant Flow VRF heat pump, air cooled Yes 216 216 0 192 192 135.4 161.1 <br />ACCU-R15A & <br />15B Variable Refrigerant Flow VRF heat pump, air cooled Yes 216 216 0 192 192 129.6 191.8 <br />1FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per <br />§140.4(a). Healthcare facilities are excepted. <br />2It is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables. <br />3 If equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank. <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 4 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) <br />Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters) <br />01 02 03 04 05 06 07 08 09 10 11 <br />4 Authority Having Jurisdiction may ask for load calculations used for compliance per §140.4(b). <br />Dry System Equipment Efficiency (other than Package Terminal Air Conditioners (PTAC) and Package Terminal Heat Pumps (PTHP)) <br />01 02 03 04 05 06 07 08 09 <br />Name or Item <br />Tag <br />Size Category <br />(Btu/h) <br />Heating Mode Cooling Mode <br />Rating <br />Condition <br />( °F) <br />Efficiency Unit <br />Minimum <br />Efficiency <br />Required per <br />Tables 110.2 / <br />Title 20 <br />Design Efficiency Efficiency Unit <br />Minimum <br />Efficiency <br />Required per <br />Tables 110.2 / <br />Title 20 <br />Design Efficiency <br />ACCU-R01 >=135,000 and <240,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.2 3.2 EER <br />IEER <br />10.6 <br />13.9 <br />11.1 <br />21.9 <br />ACCU-R03C >=65,000 and <135,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.3 3.48 EER <br />IEER <br />11 <br />14.6 <br />13 <br />23.6 <br />ACCU-R07A >=135,000 and <240,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.2 3.53 EER <br />IEER <br />10.6 <br />13.9 <br />11 <br />23 <br />ACCU-R07B >=135,000 and <240,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.2 3.53 EER <br />IEER <br />10.6 <br />13.9 <br />11.1 <br />21.9 <br />ACCU-R08A <br />THRU <br />ACCU-R14A <br />(TYP.) <br />>=135,000 and <240,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.2 3.84 EER <br />IEER <br />10.6 <br />13.9 <br />12.1 <br />23 <br />ACCU-R08B <br />THRU <br />ACCU-R14B <br />(TYP.) <br />>=135,000 and <240,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.2 3.75 EER <br />IEER <br />10.6 <br />13.9 <br />11 <br />23 <br />ACCU-R15A & <br />15B >=135,000 and <240,000 47 °Fdb/ 43 <br />°Fwb OSA HSPF 3.2 3.75 EER <br />IEER <br />10.6 <br />13.9 <br />11 <br />23 <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 5 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />G. PUMPS <br />This section does not apply to this project. <br />H. FAN SYSTEMS & AIR ECONOMIZERS <br />This section does not apply to this project. <br />I. SYSTEM CONTROLS <br />This table is used to demonstrate compliance with mandatory controls in §110.2  and §120.2  and prescriptive controls in §140.4(f)  and (n) or requirements in §141.0(b)2E  for altered <br />space conditioning systems. <br />01 02 03 04 05 06 07 08 09 <br />System Name System <br />Zoning <br />Conditioned <br />Floor Area <br />Being Served <br />(ft2) <br />Thermostats <br />§110.2(b)  & (c)1, <br />§120.2(a)or §141.0(b)2E  <br />Shut-Off <br />Controls <br />§120.2(e)  <br />Isolation <br />Zone <br />Controls <br />§120.2(g)  <br />Demand Response <br />§110.12  and §120.2(b)  <br />Supply Air <br />Temp. Reset <br />§140.4(f)  <br />Window Interlocks per <br />§140.4(n)  <br />IDU-LXX-RXXX (VRF <br />INDOOR UNITS -DWELLING <br />UNITS) <br />Single zone <= 25,000 ft2 Setback NA: HRR <br />dwelling unit <br />NA: Single <br />Zone DR Tstat per §110.12 NA: Single <br />Zone NA: HRR dwelling unit <br />IDU-LXX-CXX (VRF INDOOR <br />UNITS FOR RESIDENTIAL <br />CORRIODORS FLR 7-15) <br />Single zone <= 25,000 ft2 Setback NA: HRR <br />dwelling unit <br />NA: Single <br />Zone DR Tstat per §110.12 NA: Single <br />Zone NA: HRR dwelling unit <br />IDU-L07-AXXX (VRF <br />INDOOR UNITS OF <br />AMENITY SPACES ON 7TH <br />FLR) <br />Single zone <= 25,000 ft2 Setback Occ. Sensor Occ. Sensor DR Tstat per §110.12 NA: Single <br />Zone NA: No operable windows <br />IDU-L06-XX (VRF INDOOR <br />UNITS OF AMENITY SPACES <br />ON 6TH FLR) <br />Single zone <= 25,000 ft2 Setback Occ. Sensor Occ. Sensor DR Tstat per §110.12 NA: Single <br />Zone NA: No operable windows <br />IDU-L06-CXX (VRF INDOOR <br />UNITS FOR 6TH FLR <br />CORRIODORS) <br />Single zone <= 25,000 ft2 Setback Occ. Sensor NA: Single <br />Zone DR Tstat per §110.12 NA: Single <br />Zone NA: No operable windows <br />IDU-L01-XX (VRF INDOOR <br />UNITS ON 1ST FLR)Single zone <= 25,000 ft2 Setback Occ. Sensor Occ. Sensor DR Tstat per §110.12 NA: Single <br />Zone NA: No operable windows <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 7 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />J. VENTILATION AND INDOOR AIR QUALITY <br />04 05 06 07 <br />System Name ACCU-R01, IDU-L01-05 System Design OA CFM <br />Airflow1 60 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />Level 1 - Mail <br />Room <br />R01G17 <br />Corridor 371 3 55.65 <br />DCV NA: Not required per <br />§120.1(d)3  <br />Occ Sensor Provided per <br />§120.1(d)5  <br />17 Total System Required Min OA CFM 55.65 18 Ventilation for this System Complies?Yes <br />04 05 06 07 <br />System Name ACCU-R01, IDU-L01-03 System Design OA CFM <br />Airflow1 535 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />Level 1 - West <br />Lobby <br />R01H16 <br />Lobbies 1070 5 535 <br />DCV <br />NA: Area < 150ft2 or <br />design occupancy < <br />10 people <br />Occ Sensor Provided per <br />§120.1(d)5  <br />17 Total System Required Min OA CFM 535 18 Ventilation for this System Complies?Yes <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 8 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />J. VENTILATION AND INDOOR AIR QUALITY <br />04 05 06 07 <br />System Name ACCU-R03C, IDU-L01-01 System Design OA CFM <br />Airflow1 480 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />Level 1 - East <br />Lobby <br />R01H08 <br />Lobbies 955 5 477.5 <br />DCV <br />NA: Area < 150ft2 or <br />design occupancy < <br />10 people <br />Occ Sensor Provided per <br />§120.1(d)5  <br />17 Total System Required Min OA CFM 477.5 18 Ventilation for this System Complies?Yes <br />04 05 06 07 <br />System Name ACCU-R03C, IDU-L01-02 System Design OA CFM <br />Airflow1 35 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />Level 1 - <br />Elevator <br />Lobby <br />R01H10 <br />Corridor 232 1 34.8 <br />DCV <br />NA: Area < 150ft2 or <br />design occupancy < <br />10 people <br />Occ Sensor Provided per <br />§120.1(d)5  <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 9 of 26) <br />Project Address: Date Prepared: 2024-06-14T02:27:10-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-06-13 23:27:15 <br />J. VENTILATION AND INDOOR AIR QUALITY <br />17 Total System Required Min OA CFM 34.8 18 Ventilation for this System Complies?Yes <br />04 05 06 07 <br />System Name ACCU-R06, IDU-L06-02 System Design OA CFM <br />Airflow1 125 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />Level 6 - <br />Conference <br />Room R06F15 <br />Conference/ meeting 243 8 121.5 <br />DCV <br />NA: Area < 150ft2 or <br />design occupancy < <br />10 people <br />Occ Sensor <br />NA: System < 2kW <br />demand + manual <br />shutoff per <br />§120.2(e)3  exception <br />17 Total System Required Min OA CFM 121.5 18 Ventilation for this System Complies?Yes <br />04 05 06 07 <br />System Name ACCU-R06, IDU-L06-01 System Design OA CFM <br />Airflow1 125 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 2 of 26) <br />Project Address: Date Prepared: 2024-09-27T16:57:22-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-09-27 13:57:29 <br />C. COMPLIANCE RESULTS <br />Table C will indicate if the project data input into the compliance document is compliant with mechanical requirements. This table is not editable by the user. If this table says "DOES <br />NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D., or the table indicated as not compliant for guidance. <br />01 <br />AND <br />02 <br />AND <br />03 <br />AND <br />04 <br />AND <br />05 <br />AND <br />06 <br />AND <br />07 <br />AND <br />08 09 <br />System <br />Summary <br />§110.1, <br />§110.2, <br />§140.4  <br />Pumps <br />§140.4(k)  <br />Fans/ <br />Economizers <br />§140.4(c), <br />§140.4(e)  <br />System <br />Controls <br />§110.2, <br />§120.2, <br />§140.4(f)  <br />Ventilation <br />§120.1  <br />Terminal Box <br />Controls <br />§140.4(d)  <br />Distribution <br />§120.3, <br />§140.4(l)  <br />Cooling Towers <br />§110.2(e)2 Compliance Results <br />(See Table F)(See Table G)(See Table H)(See Table I)(See Table J)(See Table K)(See Table L)(See Table M) <br />Yes AND AND AND Yes AND Yes AND AND Yes AND COMPLIES <br />Mandatory Measures Compliance (See Table Q for Details)COMPLIES <br />D. EXCEPTIONAL CONDITIONS <br />This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. <br />Table J indicates continuous ventilation is being used as an alternative to a balanced systems. However, Table J also indicates that both supply and exhaust fans are being used. Please <br />verify the same ventilation type is being used in all dwelling units. <br />E. ADDITIONAL REMARKS <br />This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. <br />{General Remarks} This form is being submitted under Tenant Interior scope only. Only VRF Indoor units (IDU) are part of Tenant Interior scope. All the Condensing units listed on the <br />form (ACCU) are under Core & Shell scope, submitted under Permit No. B-101107990, B-101107992 & B-101107993. For Core and shell NRCC compliance forms, refer to the Core & <br />Shell Mechanical Drawings. <br />STATE OF CALIFORNIA <br />Mechanical Systems <br />NRCC-MCH-E CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: 3rd & Broadway West Building Report Page: (Page 6 of 26) <br />Project Address: Date Prepared: 2024-09-27T16:57:22-04:00 <br />Registration Number:Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 <br />Schema Version: rev 20200601 <br />Compliance ID: 206053 <br />Report Generated: 2024-09-27 13:57:29 <br />I. SYSTEM CONTROLS <br />1FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non-central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to <br />have setback thermostats. <br />*Notes: Controls with a * require a note in the space below explaining how compliance is achieved. EX: system 1: SA Temp Reset: Exempt because zones compliant with §140.4(d) ; <br />EXCEPTION 1 to §140.4(f)  <br />J. VENTILATION AND INDOOR AIR QUALITY <br />This table is used to demonstrate compliance with mandatory ventilation requirements in §120.1  and §120.2(e)3B  for all nonresidential, high-rise residential and hotel/motel <br />occupancies. For alterations, only ventialtion systems being altered within the scope of the permit application need to be documented in this table. In lieu of this table, the required <br />outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented in a spreadsheet. <br />01 Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table. <br />02 Check this box if the project included Nonresidential or Hotel/Motel spaces <br />Check this box if the project included new or altered high-rise residential dwelling units. <br />03 Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per §120.1(c)2. <br />Nonresidential and Hotel/ Motel Ventilation Systems <br />04 05 06 07 <br />System Name ACCU-R01, IDU-L01-04 System Design OA CFM <br />Airflow1 45 System Design <br />Transfer Air CFM 0 <br />Air Filtration per §120.1(c)  and §141.0(b)2 2 <br />Provided per §120.1(c)  (NR and <br />Hotel/Motel)) <br />08 09 10 11 12 13 14 15 16 <br />Space Name <br />ot item Tag <br />Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4  <br />DCV or Sensor Controls per §120.1(d)3, <br />§120.1(d)5, and §120.1(e)3 6Occupancy Type4 <br />Conditioned <br />Floor Area <br />(ft2) <br /># of Shower <br />heads/ <br />toilets <br /># of <br />people5 <br />Required <br />Min OA <br />CFM <br />Required <br />Min CFM <br />Provided per Design <br />CFM <br />Level 1 - <br />Leasing Office <br />R01G16 <br />Office space 300 3 45 <br />DCV <br />NA: Area < 150ft2 or <br />design occupancy < <br />10 people <br />Occ Sensor Provided per <br />§120.1(d)5  <br />17 Total System Required Min OA CFM 45 18 Ventilation for this System Complies?Yes <br />1/15/2025