My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Apt TI - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Apt TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:47 AM
Creation date
2/13/2026 5:00:39 AM
Metadata
Fields
Template:
Plan
Permit Number
101120329
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
? <br />? <br />R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R08R11' <br />EF <br />7-2 <br />12x6 TE <br />12x6 TE <br />12 <br />x <br />8 <br /> <br />T <br />E <br />12 <br />x <br />8 <br /> <br />T <br />E <br />EF <br />7-1 <br />REFER TO PERMITS: <br />B-101107992, <br />B-101107990, <br />B-101107993 <br />POOL SPACE N.I.C <br />N.I.C N.I.C <br />315-OA <br />IDU <br />L07-A04 <br />IDU <br />L07-A01 <br />8"X8" WALL <br />OPENING ABOVE <br />SA DUCT <br />U <br />UU <br />IDU <br />L07-A03 <br />VESTIBULE <br />R07H11 <br />ELEVATOR <br />LOBBY <br />R07H10 VESTIBULE <br />R07H09 <br />MEP ROOM <br />R07J10 <br />VESTIBULE <br />R07H15 <br />ELEVATOR <br />LOBBY <br />R07H14 <br />TRASH ROOM <br />R07G15 <br />FITNESS STUDIO <br />R07J13 <br />YOGA STUDIO <br />R07H13 <br />JANITOR <br />R07H12A <br />MEN <br />R07H12B <br />CORRIDOR <br />R07H12C <br />LIFT STORAGE <br />R07H12D WOMEN <br />R07H12E <br />CORRIDOR <br />R07J11A <br />CLUB HOUSE <br />R07J11B <br />STAIR 02 <br />R116 <br />ELEVATOR 03 <br />R117 <br />STAIR 01 <br />R118 <br />ELEVATOR 01 <br />R119 <br />ELEVATOR 02 <br />R121 <br />POOL DECK <br />R122 <br />CIRCULATION <br />R07G13 <br />CIRCULATION <br />R07G09 <br />2BR_2 <br />R07G08 <br />ST_1 <br />R07F09A <br />ST_1 <br />R07F09B <br />2BR_1 <br />R07F10 <br />ST_1 <br />R07F11A <br />ST_1 <br />R07F11B <br />ST_1 <br />R07F12 <br />2BR_1 <br />R07F13 <br />ST_1 <br />R07F14A <br />ST_1 <br />R07F14B <br />ST_1 <br />R07F15 <br />2BR_2 <br />R07G16 <br />ST_1 <br />R07H16 <br />1BR_1 <br />R07J09 <br />18"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />IDU <br />L07-R01A <br />EF <br />1 <br />14x10 SA <br />10x6 SA <br />275 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA <br />245 CFMA <br />10x6 SA <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />14"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />14x10 SA <br />30x6 RA <br />380 CFMC <br />10x6 SA <br />190 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA <br />225 CFMA <br />8x6 SA <br />100 CFMA <br />6ø OA <br />14x6 SA <br />6ø TE <br />EF <br />1 <br />IDU <br />L07-R01B <br />22x22 RA <br />570 CFME <br />4ø KE <br />6ø TE <br />36x6 RA <br />460 CFMC <br />6ø OA <br />IDU <br />L07-R02 <br />IDU <br />L07-R03 <br />IDU <br />L07-R04 <br />IDU <br />L07-R05 <br />IDU <br />L07-R06 <br />IDU <br />L07-R07 <br />IDU <br />L07-R08 <br />IDU <br />L07-R09 <br />IDU <br />L07-R10 <br />IDU <br />L07-R11 <br />IDU <br />L07-R12A <br />IDU <br />L07-R12B <br />IDU <br />L07-R13 <br />IDU <br />L07-C02 <br />IDU <br />L07-A02A <br />IDU <br />L07-R14 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />8x6 SA <br />175 CFM <br />(TYP. OF 2) <br />A <br />235-OA <br />26"X6" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø OA <br />6ø <br /> <br />T <br />E <br />4ø <br /> <br />K <br />E <br />14 <br />x <br />6 <br /> <br />S <br />A <br />22x22 RA <br />225 CFME <br />SUPPLY & RETURN ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 -R08H13 <br />10x6 SA <br />195 CFM <br />(TYP. OF 2) <br />A <br />8x6 SA <br />85 CFM <br />(TYP. OF 2) <br />A <br />8x6 SA <br />145 CFM <br />(TYP. OF 2) <br />A <br />12x6 RA <br />165 CFMC <br />20x6 RA <br />285 CFMC <br />14"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />8"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />36"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />22x22 RA <br />395 CFME <br />6x8 SA <br />12x10 SA <br />14x10 SA <br />6x10 SA <br />6ø <br /> <br />T <br />E <br />6ø TE <br />4ø KE <br />8x10 OA <br />14"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />8"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />36"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø TE <br />4ø KE <br />6ø <br /> <br />T <br />E <br />6x10 SA <br />12x10 SA <br />14x10 SA <br />6x8 SA <br />8x6 SA <br />85 CFM <br />(TYP. OF 2) <br />A8x6 SA <br />145 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA <br />195 CFM <br />(TYP. OF 2) <br />A <br />22x22 RA <br />395 CFME <br />12x6 RA <br />165 CFMC20x6 RA <br />285 CFMC <br />8x10 OA <br />4ø KE <br />6ø <br /> <br />O <br />A <br />24"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />12x6 SA <br />300 CFM <br />(TYP. OF 2) <br />A <br />12x10 SA <br />10x6 SA <br />10x6 SA <br />245 CFMA <br />10 <br />x <br />6 <br /> <br />S <br />A <br />6ø TE <br />24x12 RA <br />600 CFMC <br />16"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />12 <br />x <br />8 <br /> <br />S <br />A <br />10x6 SA <br />190 CFM <br />(TYP. OF 2) <br />A <br />10 <br />x <br />8 <br /> <br />S <br />A <br />8x6 SA <br />100 CFMA <br />10x6 SA <br />225 CFMA <br />30x6 RA <br />380 CFMC <br />6ø TE <br />6ø OA <br />22x22 RA <br />670 CFME <br />20-OA <br />6ø <br /> <br />O <br />A <br />6ø <br /> <br />O <br />A <br />8ø <br /> <br />O <br />A <br />8ø OA <br />8ø <br /> <br />O <br />A <br />10ø SA <br />250 CFM <br />(TYP. OF 2) <br />B <br />12x8 SA 12x6 SA <br />22x22 RA <br />265 CFME <br />20x16 SA <br />22x22 RA <br />2260 CFME <br />300-OA <br />235-OA (TYP. OF 2) <br />10 <br />ø <br /> <br />O <br />A <br />22x22 RA <br />2260 CFM <br />(TYP. OF 2) <br />E <br />14x10 SA <br />45-OA <br />6ø <br /> <br />O <br />A <br />10x10 TE <br />200 CFMD <br />10x10 TE <br />250 CFMD <br />22x22 RA <br />140 CFME <br />22x22 RA <br />140 CFME <br />8x8 SA <br />6ø SA <br />140 CFM <br />(TYP. OF 2) <br />B <br />16x14 SA <br />16x14 SA <br />20x16 SA <br />16x12 SA <br />14x6 SA <br />355 CFM <br />(TYP. OF 2) <br />A <br />30x6 RA <br />355 CFM <br />(TYP. OF 2) <br />C <br />8x <br />4 <br /> <br />E <br />A <br />44 <br />x <br />1 <br />2 <br /> <br />S <br />A <br />20x16 SA <br />24x6 SA <br />565 CFM <br />(TYP. OF 8) <br />A <br />55 <br />x <br />1 <br />2 <br /> <br />R <br />A <br />12ø SA <br />565 CFM <br />(TYP. OF 4) <br />B <br />12ø SA <br />8ø <br /> <br />O <br />A <br />55x15 RA <br />IDU <br />L07-A02B <br />BCC <br />7A-01 <br />BCC <br />7A-02 <br />BCC <br />7B-01 <br />BCC <br />7B-02 <br />1. MIN. 10'-0" DISTANCE SHALL BE MAINTAINED BETWEEN THE OA INTAKE & <br />EXHAUST DUCTS. <br />2. ALL KITCHEN HOODS ARE VENTLESS. <br />3. ALL TOILET & JANITOR EXHAUST FANS SHALL BE ENERGY STAR RATED. <br />4. OA DUCT TO BE INSULATED FOR 1ST 10'-0" FROM THE INTAKE LOUVER. <br />5. PER CODE ALL SMOKE, FIRE AND COMBINATION SMOKE & FIRE DAMPERS <br />SHALL REQUIRE ACCESS THAT SHALL NOT REQUIRE THE USE OF TOOLS, <br />KEYS OR SPECIAL KNOWLEDGE. ALL ACCESS POINTS SHALL BE <br />PERMANENTLY IDENTIFIED ON THE EXTERIOR BY A LABEL WITH LETTERS <br />NOT LESS THAN 1/2" IN HEIGHT READING: "SMOKE DAMPER" , "FIRE <br />DAMPER" OR "COMBINATION F/S DAMPER". <br />6. FOR ALL NON-DUCTED RETURN AIR SYSTEMS IN NON-DWELLING UNITS, ALL <br />MATERIALS EXPOSED IN A RETURN PLENUM / CEILING SHALL BE NON- <br />COMBUSTIBLE, PLENUM RATED OR HAVE FLAME SPREAD INDEX NO <br />GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NO GREATER THAN 50. <br />7. PROVIDE A MIN. OF 100 SQ. INCHES OPENING FOR MAKE-UP AIR IN THE <br />LAUNDRY CLOSET DOORS OF EACH DWELLING UNIT. <br />8. EXHAUST OPENINGS TERMINATING TO THE OUTDOORS SHALL BE <br />COVERED WITH CORROSION RESISTANT SCREEN HAVING NOT LESS THAN <br />1/4" NOR LARGER THAN 1/2" OPENINGS. <br />9. EACH AC INDOOR UNIT SHALL BE PROVIDED WITH MIN. OF 2" THICK <br />MERV-13 FILTERS. <br />10. FILTERS SHALL HAVE A DESIGNATED EFFICIENCY EQUAL TO OR GREATER <br />THAN MERV-13 WHEN TESTED IN ACCORDANCE WITH ASHRAE STD 52.2 OR <br />A PARTICLE SIZE EFFICIENCY RATING EQUAL TO OR GREATER THAN 50% IN <br />THE 0.3 - 1.0 MICRONS RANGE AND EQUAL TO OR GREATER THAN 85% IN <br />THE 1.0-3.0 MICRONS RANGE WHEN TESTED IN ACCORDANCE WITH AHRI <br />STD 680. <br />SHEET NOTES GENERAL NOTES KEY PLAN <br />NORTH <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />EXP: 12/31/2025 <br />As indicated <br />6/12/2024 7:41:48 AM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/228011-04_3RD-B_MECH_R20.rvt <br />R2.M2.107 <br />MECHANICAL DUCTWORK PLAN - <br />LEVEL 07 <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />SCALE:1/8" = 1'-0" <br />MECHANICAL DUCTWORK PLAN - LEVEL 071 <br />BCC <br />XXY-ZZ <br />BCC -VRF BRANCH CONTROLLER <br />XX -FLOOR No. <br />Y -CONDENSING UNIT, SYSTEM A OR B FOR RESPECTIVE FLOOR <br />ZZ -COUNT <br />IDU <br />LXX-YZZ <br />IDU -VRF INDOOR UNIT <br />XX -FLOOR No. <br />Y - A=AMENITY, C=CORRDIOR OR R=RESIDENCE <br />ZZ -COUNT <br />LEGEND: <br />2 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />1 08.10.2022 REISSUE FOR PLAN CHECK <br />2 06.17.2024 REVISION TO PERMIT <br />1/15/2025
The URL can be used to link to this page
Your browser does not support the video tag.