My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Apt TI - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Apt TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:47 AM
Creation date
2/13/2026 5:00:39 AM
Metadata
Fields
Template:
Plan
Permit Number
101120329
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. MIN. 10'-0" DISTANCE SHALL BE MAINTAINED BETWEEN THE OA INTAKE & EXHAUST DUCTS. <br />2. ALL KITCHEN HOODS ARE VENTLESS. <br />3. ALL TOILET EXHAUST FANS SERVING THE RESIDENTIAL UNITS SHALL BE ENERGY STAR <br />RATED. <br />4. OA DUCT TO BE INSULATED FOR 1ST 10'-0" FROM THE INTAKE LOUVER. <br />5. PER CODE ALL SMOKE, FIRE AND COMBINATION SMOKE & FIRE DAMPERS SHALL REQUIRE <br />ACCESS THAT SHALL NOT REQUIRE THE USE OF TOOLS, KEYS OR SPECIAL KNOWLEDGE. <br />ALL ACCESS POINTS SHALL BE PERMANENTLY IDENTIFIED ON THE EXTERIOR BY A LABEL <br />WITH LETTERS NOT LESS THAN 1/2" IN HEIGHT READING: "SMOKE DAMPER" , "FIRE <br />DAMPER" OR "COMBINATION F/S DAMPER". <br />6. FOR ALL NON-DUCTED RETURN AIR SYSTEMS IN NON-DWELLING UNITS, ALL MATERIALS <br />EXPOSED IN A RETURN PLENUM / CEILING SHALL BE NON-COMBUSTIBLE, PLENUM RATED <br />OR HAVE FLAME SPREAD INDEX NO GREATER THAN 25 AND A SMOKE DEVELOPED INDEX <br />NO GREATER THAN 50. <br />7. PROVIDE A MIN. OF 100 SQ. INCHES OPENING FOR MAKE-UP AIR IN THE LAUNDRY CLOSET <br />DOORS OF EACH DWELLING UNIT. <br />8. EXHAUST OPENINGS TERMINATING TO THE OUTDOORS SHALL BE COVERED WITH <br />CORROSION RESISTANT SCREEN HAVING NOT LESS THAN 1/4" NOR LARGER THAN 1/2" <br />OPENINGS. <br />9. EACH AC INDOOR UNIT SHALL BE PROVIDED WITH MIN. OF 2" THICK MERV-13 FILTERS. <br />10. FILTERS SHALL HAVE A DESIGNATED EFFICIENCY EQUAL TO OR GREATER THAN MERV-13 <br />WHEN TESTED IN ACCORDANCE WITH ASHRAE STD 52.2 OR A PARTICLE SIZE EFFICIENCY <br />RATING EQUAL TO OR GREATER THAN 50% IN THE 0.3 - 1.0 MICRONS RANGE AND EQUAL <br />TO OR GREATER THAN 85% IN THE 1.0-3.0 MICRONS RANGE WHEN TESTED IN <br />ACCORDANCE WITH AHRI STD 680. <br />R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R08R11' <br />8x6 SA <br />175 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA <br />255 CFMA <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />10x6 SA <br />245 CFM <br />(TYP. OF 2) <br />A <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />10x6 SA <br />225 CFM <br />(TYP. OF 2) <br />A <br />40"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10x6 SA <br />255 CFMA <br />22x22 RA <br />420 CFMEEF <br />1 <br />22x22 RA <br />440 CFME <br />8x6 SA <br />175 CFM <br />(TYP. OF 2) <br />A <br />OA DUCT TO BE INSULATED FOR 1ST <br />10'-0" FROM THE INTAKE LOUVER <br />(TYP.) <br />EF <br />1 <br />6ø <br /> <br />O <br />A <br />6ø <br /> <br />T <br />E <br />6ø <br /> <br />T <br />E <br />6ø <br /> <br />O <br />A <br />4ø <br /> <br />K <br />E <br />4ø <br /> <br />K <br />E <br />8x <br />8 <br /> <br />O <br />A <br />6ø TE <br />4ø <br /> <br />K <br />E <br />6ø TE <br />4ø <br /> <br />K <br />E <br />8ø <br /> <br />O <br />A <br />4ø KE <br />6ø TE <br />8ø <br /> <br />O <br />A <br />4ø KE <br />6ø TE <br />6ø OA4ø <br /> <br />K <br />E <br />6ø TE 6ø TE <br />6ø OA <br />4ø <br /> <br />K <br />E <br />N.I.C N.I.C <br />8ø SA <br />245 CFM <br />(TYP. OF 2) <br />B <br />22x22 RA <br />345 CFME <br />IDU <br />LXX-C01 10x6 SA12x8 SA <br />10x6 SA <br />MEP ROOM <br />R08J10 <br />VESTIBULE <br />R08H09 <br />ELEVATOR <br />LOBBY <br />R08H10 <br />VESTIBULE <br />R08H11 <br />TRASH ROOM <br />R08G15 <br />ELEVATOR <br />LOBBY <br />R08H14 <br />VESTIBULE <br />R08H15 <br />ELEVATOR 01 <br />R149 <br />ELEVATOR 02 <br />R150 <br />STAIR 01 <br />R151 <br />STAIR 02 <br />R152 <br />ELEVATOR 03 <br />R153 <br />CIRCULATION <br />R08G13 <br />CIRCULATION <br />R08G09 2BR_2 <br />R08G10 <br />ST_1 <br />R08F09A <br />ST_1 <br />R08F09B <br />ST_1 <br />R08F10A <br />ST_1 <br />R08F10B <br />1BR_2 <br />R08F11A <br />ST_1 <br />R08F11B <br />1BR_2 <br />R08F12 <br />1BR_2 <br />R08F13 <br />ST_1 <br />R08F14A <br />ST_1 <br />R08F14B <br />ST_1 <br />R08F15A <br />ST_1 <br />R08F15B <br />2BR_2 <br />R08G16 <br />1BR_1 <br />R08J09 <br />1BR_2 <br />R08J11 <br />ST_1 <br />R08H11A <br />ST_1 <br />R08H12A <br />ST_1 <br />R08H12B <br />1BR_1 <br />R08H131BR_1 <br />R08H16 <br />IDU <br />LXX-R01B <br />IDU <br />LXX-R02 <br />IDU <br />LXX-R03 <br />IDU <br />LXX-R04 <br />IDU <br />LXX-R05 <br />IDU <br />LXX-R06 <br />EF <br />1 <br />EF <br />1 <br />IDU <br />LXX-C02 <br />IDU <br />LXX-R07 <br />IDU <br />LXX-R08 <br />IDU <br />LXX-R09 IDU <br />LXX-R10 <br />IDU <br />LXX-R11 <br />IDU <br />LXX-R12 <br />IDU <br />LXX-R13 <br />IDU <br />LXX-R16 <br />IDU <br />LXX-R15 <br />IDU <br />LXX-R17 <br />IDU <br />LXX-R18 <br />IDU <br />LXX-R19IDU <br />LXX-R20 <br />IDU <br />LXX-R21 <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15B <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08F15A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET AND <br />KITCHEN EXHAUST <br />DUCTWORKS ARE SIMILAR TO <br />UNIT: 1BR_2 -R08F11A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST <br />DUCTWORKS ARE <br />SIMILAR TO UNIT: ST_1 - <br />R08H11A <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET AND <br />KITCHEN EXHAUST <br />DUCTWORKS ARE SIMILAR TO <br />UNIT: 1BR_1 -R08H13 <br />SUPPLY & RETURN <br />ARRANGEMENT, TOILET AND <br />KITCHEN EXHAUST <br />DUCTWORKS ARE SIMILAR TO <br />UNIT: 1BR_1 -R08H16 <br />22x22 RA <br />225 CFME <br />22x22 RA <br />225 CFME <br />IDU <br />LXX-R01A <br />BCC <br />XA-02 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />IDU <br />LXX-R14A <br />IDU <br />LXX-R14B <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />14 <br />x <br />6 <br /> <br />S <br />A <br />14 <br />x <br />6 <br /> <br />S <br />A <br />26"X6" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />(TYP. OF 2) <br />22x22 RA <br />365 CFME22x22 RA <br />365 CFME <br />38"X6" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />38"X6" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10x6 SA <br />245 CFM <br />(TYP. OF 2) <br />A <br />18 <br />x <br />6 <br /> <br />S <br />A <br />18 <br />x <br />6 <br /> <br />S <br />A <br />10x6 SA 10x6 SA <br />10x6 SA <br />225 CFM <br />(TYP. OF 2) <br />A <br />12x8 SA 10x6 SA <br />18x6 RA <br />255 CFMC <br />12"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />22x22 RA <br />420 CFME <br />40"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />12"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />12"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10x6 SA <br />235 CFMA <br />10x6 SA <br />200 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA 12x8 SA <br />12 <br />x <br />1 <br />0 <br /> <br />S <br />A <br />18x6 RA <br />235 CFMC <br />22x22 RA <br />380 CFME <br />8ø <br /> <br />O <br />A <br />12"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />12x8 SA 10x6 SA <br />12 <br />x <br />1 <br />0 <br /> <br />S <br />A <br />12 <br />x <br />1 <br />0 <br /> <br />S <br />A <br />18x6 RA <br />255 CFMC <br />12"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />18x6 RA <br />255 CFMC <br />40"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10x6 SA 12x8 SA <br />10x6 SA <br />225 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA <br />255 CFMA <br />12 <br />x <br />1 <br />0 <br /> <br />S <br />A <br />8x6 OA <br />150-OA <br />8x4 OA <br />8x <br />6 <br /> <br />O <br />A <br />6ø <br /> <br />O <br />A <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />22x22 RA <br />880 CFME <br />22"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10x6 SA <br />275 CFM <br />(TYP. OF 2) <br />A <br />14x10 SA <br />12 <br />x <br />6 <br /> <br />S <br />A <br />12x6 SA <br />295 CFMA <br />10x6 SA <br />225 CFM <br />(TYP. OF 2) <br />A <br />12x6 SA <br />295 CFMA <br />8x6 SA <br />100 CFMA <br />14 <br />x <br />6 <br /> <br />S <br />A <br />14x10 SA <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />30x6 RA <br />450 CFMC <br />22"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø TE <br />6ø TE <br />BCC <br />XB-01 <br />BCC <br />XB-02 <br />BCC <br />XA-01 <br />105-OA <br />6ø OA <br />6ø OA <br />10x6 SA <br />200 CFM <br />(TYP. OF 2) <br />A <br />12x10 SA <br />30x6 RA <br />400 CFMC <br />16"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />22x22 RA <br />750 CFME <br />12x6 SA <br />205 CFMA <br />8x6 SA <br />100 CFMA <br />10 <br />x <br />8 <br /> <br />S <br />A <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />20"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />30"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø TE <br />12x6 SA <br />205 CFMA <br />12 <br />x <br />6 <br /> <br />S <br />A <br />6ø <br /> <br />O <br />A <br />10x6 SA <br />250 CFM <br />(TYP. OF 2) <br />A <br />12x10 SA <br />6ø TE <br />6ø OA <br />36x6 RA <br />550 CFMC <br />36x6 RA <br />500 CFMC <br />12x8 SA <br />4ø KE4ø KE <br />6ø OA <br />SHEET NOTES GENERAL NOTES KEY PLAN <br />NORTH <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />EXP: 12/31/2025 <br />As indicated <br />6/12/2024 7:42:07 AM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/228011-04_3RD-B_MECH_R20.rvt <br />R2.M2.108 <br />MECHANICAL DUCTWORK PLAN - <br />LEVEL 08 - LEVEL 14 <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />SCALE:1/8" = 1'-0" <br />MECHANICAL DUCTWORK PLAN - LEVEL 08 - LEVEL 141 <br />BCC <br />XY-ZZ <br />BCC -VRF BRANCH CONTROLLER <br />X -FLOORS 08 TO 14 <br />Y -CONDENSING UNIT, SYSTEM A OR B FOR RESPECTIVE FLOOR <br />ZZ -COUNT <br />IDU <br />LXX-YZZ <br />IDU -VRF INDOOR UNIT <br />XX -FLOORS 08 TO 14 <br />Y - A=AMENITY, C=CORRDIOR OR R=RESIDENCE <br />ZZ -COUNT <br />LEGEND: <br />2 <br />2 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />1 08.10.2022 REISSUE FOR PLAN CHECK <br />2 06.17.2024 REVISION TO PERMIT <br />1/15/2025