Laserfiche WebLink
? <br />? <br />R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R08R11' <br />SUPPLY & RETURN ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST DUCTWORKS ARE <br />SIMILAR TO UNIT: 2BR_1 -R15F15 <br />SUPPLY & RETURN ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST DUCTWORKS ARE <br />SIMILAR TO UNIT: 2BR_1 -R15F13 <br />EF <br />1 <br />EF <br />1 <br />6ø <br /> <br />T <br />E <br />6ø <br /> <br />O <br />A <br />4ø <br /> <br />K <br />E <br />4ø <br /> <br />K <br />E <br />6ø <br /> <br />T <br />E <br />6ø <br /> <br />O <br />A <br />22x22 RA <br />400 CFME <br />EF <br />1 <br />4ø KE <br />6ø TE <br />ARCHITECT TO PROVIDE 0.5 SQ FT MINIMUM <br />FREE AREA EXHAUST LOUVER FOR JANITOR <br />ROOM LOCATED MINIMUM 10 FT AWAY FROM <br />OPENINGS IF NOT 3 FT ABOVE <br />ARCHITECT TO PROVIDE 1.0 SQ FT MINIMUM <br />FREE AREA EXHAUST LOUVER FOR <br />RESTROOMS <br />EF <br />15-1 <br />EF <br />15-2 <br />8x <br />8 <br /> <br />T <br />E <br />12 <br />x <br />6 <br /> <br />T <br />E <br />8ø EA <br />REFER TO PERMITS: <br />B-101107992, <br />B-101107990, <br />B-101107993 <br />N.I.C <br />N.I.C <br />N.I.C <br />IDU <br />L15-R02 IDU <br />L15-R03 <br />IDU <br />L15-R04 <br />IDU <br />L15-R05 <br />IDU <br />L15-R07 <br />IDU <br />L15-R08 <br />IDU <br />L15-R09IDU <br />L15-R10 <br />STAIR 01 <br />R16D23 <br />VESTIBULE <br />R15H11 <br />STAIR 02 <br />R35 <br />ELEVATOR <br />LOBBY <br />R15H10 <br />STORAGE <br />R15H09 <br />ELEVATOR 03 <br />R38 <br />TRASH ROOM <br />R15F16 <br />VESTIBULE <br />R15H15 <br />ELEVATOR <br />LOBBY <br />R15H14 <br />ELEVATOR 01 <br />R154 <br />ELEVATOR 02 <br />R155 <br />ALL GENDER RR <br />R15F09A <br />VESTIBLE <br />R15F09B <br />ALL GENDER RR <br />R15F09C <br />JANITOR <br />R15F09D <br />EAST CORR. <br />R15F09E <br />CIRCULATION <br />R15G13 <br />STAIR 01 <br />R169 <br />STORAGE <br />R15J10 <br />CIRCULATION <br />R15G15 <br />2BR_1 <br />R15F10 <br />ST_1 <br />R15F11 <br />2BR_1 <br />R15F12 <br />2BR_1 <br />R15F132BR_1 <br />R15F15 <br />2BR_2 <br />R15G16 <br />2BR_1 <br />R15J11 <br />ST_1 <br />R15H12 <br />2BR_1 <br />R15H13 <br />1BR_1 <br />R15H16 <br />IDU <br />L15-C02B <br />IDU <br />L15-C02A <br />IDU <br />L15-C01 <br />IDU <br />L15-R01B <br />ACCESS DOOR <br />2'X2' <br />SUPPLY & RETURN ARRANGEMENT, TOILET <br />AND KITCHEN EXHAUST DUCTWORKS ARE <br />SIMILAR TO UNIT: 2BR_1 -R15H13 <br />IDU <br />L15-R01A <br />28"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />EF <br />1 <br />EF <br />1 EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 EF <br />1 EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />EF <br />1 <br />IDU <br />L15-R06 <br />EF <br />1 <br />8ø OA 8ø OA <br />8ø OA <br />14 <br />x <br />8 <br /> <br />S <br />A <br />10x6 SA <br />265 CFM <br />(TYP. OF 2) <br />A <br />26"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />22x22 RA <br />365 CFME <br />12 <br />x <br />8 <br /> <br />S <br />A <br />10x6 SA <br />250 CFM <br />(TYP. OF 2) <br />A <br />12"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />12x6 SA <br />300 CFMA <br />14x6 SA <br />365 CFM <br />(TYP. OF 2) <br />A <br />22x22 RA <br />480 CFME <br />10"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />4ø KE <br />6ø TE <br />6ø TE <br />10x6 SA <br />240 CFM <br />(TYP. OF 2) <br />A <br />8x6 SA <br />175 CFM <br />(TYP. OF 2) <br />A <br />8x6 SA <br />100 CFM <br />(TYP. OF 2) <br />A <br />24x6 RA <br />350 CFMC <br />18"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />46"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø OA <br />6ø <br /> <br />T <br />E <br />BCC <br />15A-01 <br />BCC <br />15A-02 <br />BCC <br />15B-01 <br />BCC <br />15B-02 <br />44"X12" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />28"X12" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />4ø KE <br />46"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10x8 SA <br />12x14 SA <br />14x10 SA <br />14x12 SA <br />22x22 RA <br />770 CFME <br />8ø <br /> <br />O <br />A <br />12x6 RA <br />300 CFMC <br />8x10 OA <br />8x10 SA <br />14x10 SA <br />16x6 RA <br />200 CFMC <br />18x10 SA6x8 SA <br />8x6 SA <br />175 CFM <br />(TYP. OF 2) <br />A <br />8x6 SA <br />100 CFM <br />(TYP. OF 2) <br />A <br />14x10 SA <br />10x6 SA <br />240 CFM <br />(TYP. OF 2) <br />A <br />8x10 SA <br />18x10 SA <br />6x8 SA <br />24x6 RA <br />350 CFMC <br />16x6 RA <br />200 CFMC <br />18"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />46"X10" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />10"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø TE <br />4ø KE <br />22x22 RA <br />480 CFME <br />6ø <br /> <br />T <br />E <br />8x10 OA <br />25-OA <br />6ø OA <br />155-OA <br />165-OA <br />6ø OA <br />8x6 SA <br />170 CFM <br />(TYP. OF 2) <br />A <br />16x6 SA <br />450 CFM <br />(TYP. OF 2) <br />A <br />10x6 SA <br />255 CFM <br />(TYP. OF 2) <br />A <br />8x12 SA <br />18x14 SA <br />8x10 SA <br />4ø KE <br />EF <br />1 <br />6ø TE <br />6ø TE <br />6ø TE 6ø TE <br />6ø <br /> <br />T <br />E <br />18"X12" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />22x22 RA <br />895 CFME <br />18"X8" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />66"X12" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />6ø TE <br />6ø <br /> <br />T <br />E <br />8x10 OA <br />36x6 RA <br />510 CFMC24x6 RA <br />340 CFMC <br />16x14 SA <br />8x <br />1 <br />2 <br /> <br />S <br />A <br />6x6 TE <br />365 CFMD <br />6x6 TE <br />150 CFMD <br />8x <br />6 <br /> <br />T <br />E <br />6ø TE <br />6ø <br /> <br />O <br />A <br />16x12 SA <br />16x6 SA <br />410 CFM <br />(TYP. OF 2) <br />A <br />24x12 RA <br />820 CFMC <br />12x8 SA <br />16x6 SA <br />440 CFM <br />(TYP. OF 2) <br />A <br />22x22 RA <br />1120 CFME <br />24x12 RA <br />670 CFMC <br />22"X12" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />44"X12" WALL OPENING ABOVE <br />CEILING FOR TRANSFER AIR <br />14x6 SA <br />335 CFM <br />(TYP. OF 2) <br />A <br />16x12 SA <br />8x6 SA <br />150 CFMA <br />14 <br />x <br />8 <br /> <br />S <br />A <br />6ø TE <br />6ø OA <br />1. MIN. 10'-0" DISTANCE SHALL BE MAINTAINED BETWEEN THE OA INTAKE & EXHAUST DUCTS. <br />2. ALL KITCHEN HOODS ARE VENTLESS. <br />3. ALL TOILET EXHAUST FANS SERVING THE RESIDENTIAL UNITS & POOL RESTROOM SHALL BE <br />ENERGY STAR RATED. <br />4. OA DUCT TO BE INSULATED FOR 1ST 10'-0" FROM THE INTAKE LOUVER. <br />5. PER CODE ALL SMOKE, FIRE AND COMBINATION SMOKE & FIRE DAMPERS SHALL REQUIRE <br />ACCESS THAT SHALL NOT REQUIRE THE USE OF TOOLS, KEYS OR SPECIAL KNOWLEDGE. <br />ALL ACCESS POINTS SHALL BE PERMANENTLY IDENTIFIED ON THE EXTERIOR BY A LABEL <br />WITH LETTERS NOT LESS THAN 1/2" IN HEIGHT READING: "SMOKE DAMPER" , "FIRE DAMPER" <br />OR "COMBINATION F/S DAMPER". <br />6. FOR ALL NON-DUCTED RETURN AIR SYSTEMS IN NON-DWELLING UNITS, ALL MATERIALS <br />EXPOSED IN A RETURN PLENUM / CEILING SHALL BE NON-COMBUSTIBLE, PLENUM RATED OR <br />HAVE FLAME SPREAD INDEX NO GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NO <br />GREATER THAN 50. <br />7. PROVIDE A MIN. OF 100 SQ. INCHES OPENING FOR MAKE-UP AIR IN THE LAUNDRY CLOSET <br />DOORS OF EACH DWELLING UNIT. <br />8. EXHAUST OPENINGS TERMINATING TO THE OUTDOORS SHALL BE COVERED WITH <br />CORROSION RESISTANT SCREEN HAVING NOT LESS THAN 1/4" NOR LARGER THAN 1/2" <br />OPENINGS. <br />9. EACH AC INDOOR UNIT SHALL BE PROVIDED WITH MIN. OF 2" THICK MERV-13 FILTERS. <br />10. FILTERS SHALL HAVE A DESIGNATED EFFICIENCY EQUAL TO OR GREATER THAN MERV-13 <br />WHEN TESTED IN ACCORDANCE WITH ASHRAE STD 52.2 OR A PARTICLE SIZE EFFICIENCY <br />RATING EQUAL TO OR GREATER THAN 50% IN THE 0.3 - 1.0 MICRONS RANGE AND EQUAL TO <br />OR GREATER THAN 85% IN THE 1.0-3.0 MICRONS RANGE WHEN TESTED IN ACCORDANCE <br />WITH AHRI STD 680. <br />SHEET NOTES GENERAL NOTES KEY PLAN <br />NORTH <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />EXP: 12/31/2025 <br />As indicated <br />6/12/2024 7:42:25 AM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/228011-04_3RD-B_MECH_R20.rvt <br />R2.M2.115 <br />MECHANICAL DUCTWORK PLAN - <br />LEVEL 15 <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />SCALE:1/8" = 1'-0" <br />MECHANICAL DUCTWORK PLAN - LEVEL 151 <br />BCC <br />XXY-ZZ <br />BCC -VRF BRANCH CONTROLLER <br />XX -FLOOR No. <br />Y -CONDENSING UNIT, SYSTEM A OR B FOR RESPECTIVE FLOOR <br />ZZ -COUNT <br />IDU <br />LXX-YZZ <br />IDU -VRF INDOOR UNIT <br />XX -FLOOR No. <br />Y - A=AMENITY, C=CORRDIOR OR R=RESIDENCE <br />ZZ -COUNT <br />LEGEND: <br />2 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />1 08.10.2022 REISSUE FOR PLAN CHECK <br />2 06.17.2024 REVISION TO PERMIT <br />1/15/2025