Laserfiche WebLink
SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />1 INSULATION OF PIPING, VALVES AND FITTINGS <br />2 PIPE RISER SUPPORT-CONCRETE FLOOR <br />3 NO-HUB PIPE BRACING FOR VERTICAL PIPING <br />4 TYPICAL PIPE SUPPORT DETAIL <br />5 DETAIL OF PIPE HANGERS <br />6 NO-HUB PIPE BRACING FOR HORIZONTAL PIPING <br />7 HUB DRAIN AT FIRE RISER <br />8 CONDENSATE DRAIN CONN. TO LAV TAILPIECE <br />SECTIONAL <br />INSULATION <br />FIBERGLASS <br />3" <br />FIRE RETARDANT JACKET <br />WRAP WITH FIBERGLASS REINFORCING CLOTH. <br />PREMOLDED FIBERGLASS OR RADIAL MITERED <br />FINISH COAT OF MASTIC <br />COAT OF MASTIC <br />OVERLAP 2 INCHES ON PIPE INSULATION. <br />SKIM COAT OF INSULATION CEMENT. <br />PIPE INSULATION. <br />EXPOSED VALVES AND FITTINGS <br />MITERED FITTING <br />PREMOLDED FITTING <br />WRAP WITH 1 INCH THICK, 1 POUND DENSITY TO <br />VAPOR SEAL HORIZONTAL COLD WATER PIPING. <br />SECURE WITH WIRE OR TAPE. <br />CONCEALED VALVES AND FITTINGS <br />BUTT STRIP AT JOINTS. SECURE WITH <br />ADHESIVE AND OUTER HOLDING BAND OR USE <br />SELF-SEALING LAPS TYPICAL AT ALL JOINTS. <br />REQUIRED PIPE INSULATION THICKNESS. <br />SEALING LAP. SECURE WITH ADHESIVE ALL SEALS AND LAPS AT TOP. <br />NOTES: <br />1. PIPE PENETRATION THROUGH RATED AND NON-RATED FLOOR ASSEMBLIES. REFER TO <br />MANUFACTURER INSTALLATION INSTRUCTIONS FOR MATERIALS REQUIRED TO MAINTAIN FIRESTOP <br />RATING. <br />2. SELECT RISER CLAMP AS REQUIRED TO SUPPORT MINIMUM 1.5X THE DESIGN OPERATING WEIGHT OF <br />EACH PIPE SECTION. <br />PROVIDE FIRE STOP MATERIAL <br />WHERE REQUIRED TO MAINTAIN <br />RATED ASSEMBLY. <br />4-BOLT RISER CLAMP <br />1/4" STEEL PLATE <br />PIPE <br />GALVANIZED FINISH. <br />HANGER, ROD & INSERT SHALL BE ALL <br />METAL SHIELD <br />GALVANIZED <br />NOTE: <br />INSULATION <br />THREADED ROD <br />CLEVIS HANGER <br />DOUBLE LOCKNUTS <br />FELT LINING 1/4" MIN <br />THICKNESS <br />DOUBLE LOCKNUTS <br />(TYPICAL) <br />(TYPICAL) <br />COPPER PIPING <br />STANDARD <br />COVERING <br />SHIELD <br />NOTES: <br />1. EQUAL TO TOLCO CLEVIS HANGER WITH FELT <br />LINING. <br />2. UTILIZE FOR SUSPENSION OF ALL WATER PIPING. <br />INSULATED PIPES <br />(HOT OR COLD) <br />(BELOW 4") <br />UNINSULATED PIPES <br />(BELOW 4") <br />COVERING SHIELD <br />STANDARD PIPE <br />(4" AND ABOVE) <br />(COLD) <br />INSULATED PIPES <br />SPREADER TO BE <br />USED ON PIPE <br />SIZES 10" AND <br />ABOVE <br />UNINSULATED PIPES <br />(4" AND ABOVE) <br />(COLD) <br />SPREADER TO BE <br />USED ON PIPE <br />SIZES 10" AND <br />ABOVE <br />NOTES: <br />1. OBTAIN APPROVAL FROM STRUCTURAL <br />ENGINEER FOR PROPOSED TYPES OF <br />STRUCTURAL ATTACHMENTS. <br />1"2" <br />24" <br />6" W <br />SECURED TO WALL <br />8"∅ HUB DRAIN <br />6" X 8" INCREASER <br />4" VENT <br />1/2" TP <br />DRAIN RISER FROM ELECTRONIC TRAP PRIMER <br />INSULATED CNDS LINE <br />CHROME PLATED ESCUTCHEON <br />CHROME PLATED COPPER TUBING <br />1 1/4" TAILPIECE <br />TEE CONNECTION <br />1 1/2" TAILPIECE <br />WALL <br />LAVATORY <br />FIN. FLOOR <br />BRANCH <br />FRICTION CLAMP AND RODS. <br />OPENING OR CHANGE OF DIRECTION. <br />INSTALL ON EVERY BRANCH <br />TYPICAL BRACE TO PREVENT <br />ON EACH SIDE OF JOINT WITH <br />TO BUILDING STRUCTURE OR <br />AND LARGER. SECURE BRACE <br />LOCATE ON ALL PIPING 6 INCH <br />HORIZONTAL MOVEMENT. <br />TYPICAL COUPLING <br />6" AND LARGER <br />PER CPC REQUIREMENTS <br />ALL PIPES SHALL BE SUPPORTED <br />TYPICAL HANGER A <br />FLOOR <br />ROOF <br />A <br />ELEV. A-A <br />10-FT MAX. <br />TYPICAL FRICTION CLAMP AT EACH <br />FLOOR. SEE DETAIL BELOW <br />NOTES : <br />1. PIPE SEISMIC BRACING DETAILS SHALL BE PROVIDED BY <br />ISAT ENGINEERS ON SEPARATE SUBMITTALS. <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2015 <br />NOT FOR <br />CONSTRUCTION <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />Job No.: <br />Contact: <br />www.glumac.com <br />18200 Von Karman Ave., Suite 100 <br />Irvine, CA 92612 <br />T. 949.833.8190 <br />6/12/2024 7:40:12 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_MEP_WEST_R20.rvt <br />R1-P9.1 <br />PLUMBING DETAILS <br />21US00608 <br />3rd & Broadway West <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />21US00608 <br />TG <br />1 9/21/2021 REISSUE FOR PLAN CHECK <br />2 01/18/2022 REISSUE FOR PLAN CHECK <br />4 06/17/2024 REVISION TO PERMIT <br />EOR: SEAN AGUON <br />LIC#: M41274 <br />10/11/2024