Laserfiche WebLink
EAST <br />LOBBY <br />R01H08 <br />ELEVATOR <br />03 <br />R01E14 <br />R09R10 <br />RH <br />RJ <br />R08 <br />MEP ROOM <br />R01H09 <br />ELEVATOR <br />LOBBY <br />R01H10 <br />STORAGE <br />R01J09 <br />F-01 EM <br />F-01 EM F-01 <br />F-01 <br />F-01 <br />F-01 EM <br />F-03 <br />F-03 <br />F-03 <br />F-03 <br />F-03 <br />F-03 <br />F02 <br />F02 <br />F-01 EM <br />F-01 <br />F-01 <br />NORMAL LTG - PANEL H1-17 <br />EM LTG - PANEL E1H1-21 <br />PC PCOS <br />X2 <br />2 1 <br />D abc <br />OS <br />OS <br />OS <br />OS <br />OS <br />OS <br />OS <br />X2 <br />a <br />b <br />c <br />abc <br />abc abc abc <br />abcabc <br />abc <br />abc <br />a a <br />a a a <br />c <br />c <br />cc <br />c <br />d <br />d <br />d <br />R2.E6.15 <br />1. <br />2. <br />PRIMARY DAYLIGHT ZONE TO DIM DOWN WHEN <br />ABLE TO MEET TARGET DAYLIGHT LEVELS PER <br />THE SPACE TYPE. <br />SECONDARY DAYLIGHT ZONE TO DIM DOWN <br />WHEN ABLE TO MEET TARGET DAYLIGHT <br />LEVELS PER THE SPACE TYPE. <br />A. <br />B. <br />C. <br />D. <br />E. <br />F. <br />G. <br />H. <br />COORDINATE LOCATION OF LIGHTING <br />CONTROLS WITH ARCHITECT AND OWNER <br />PRIOR TO INSTALL. <br />COORDINATE EXACT LUMINAIRE FIXTURE <br />PLACEMENTS WITH ARCHITECT PRIOR TO <br />INSTALL. <br />CEILING SENSOR SWITCHES IN SAME SPACE <br />WITH SAME SWITCH DESIGNATION ARE TO BE <br />WIRED IN PARALLEL SUCH THAT EITHER <br />SENSOR WILL ACTIVATE ALL DESIGNATED <br />LIGHTS. <br />SWITCHES SERVING SAME AREA AS <br />OCCUPANCY SENSOR SHALL PROVIDE MANUAL <br />OFF CONTROL OF LIGHTING. <br />CONTRACTOR IS RESPONSIBLE TO REVIEW <br />ARCHITECTURAL DRAWINGS TO CONFIRM <br />CEILING TYPES IN ALL ROOMS (ACCESSIBLE, <br />EXPOSED, OR HARD) AND TO USE THE <br />APPROPRIATE WIRING METHOD FOR EACH <br />TYPE. INSURE ALL J-BOXES ARE ACCESSIBLE <br />AFTER ALL OTHER TRADE'S WORK IS <br />COMPLETED. DO NOT LOCATED ANY J-BOXES <br />ON HARD CEILINGS UNLESS OTHERWISE <br />NOTED; ALL WIRING MUST BE ACCESSIBLE <br />THROUGH LUMINAIRE ONLY IN DAISY-CHAIN <br />METHOD OR WITH DEDICATED HOME RUNS TO <br />EACH LUMINAIRE. J-BOXES MAY BE LOCATED <br />ABOVE OTHER TRADE'S ACCESS DOORS IF <br />FEASIBLE AND DOES NOT INTERFERE WITH <br />ACCESS. <br />ALL LOW VOLTAGE CABLING TO LIGHTING <br />FIXTURES AND CONTROL DEVICES SHALL BE <br />PLENUM RATED. <br />CONTRACTOR SHALL CONFIRM ALL EXIT SIGN <br />LOCATIONS AND DIRECTIONAL CHEVRONS <br />WITH THE ARCHITECTURAL EGRESS PLANS <br />AND REFLECTED CEILING PLANS. <br />ELECTRICAL CONTRACTOR TO PROVIDE ALL OF <br />SWITCHES SHOWN COMBINED IN ONE GANG <br />BOX; SHOWN IN THE DRAWING AS MULTIPLE <br />SWITCHES FOR CLARITY ONLY. <br />SCALE: 1/4" = 1'-0" <br />LIGHTING PLAN - LEVEL 01 GARAGE - EAST GROUND FLOOR LOBBY1 <br />NORTH <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />5/ <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />6 <br />: <br />1 <br />8 <br />: <br />3 <br />1 <br /> <br />P <br />M <br />D: <br />\ <br />_ <br />D <br />E <br />L <br />E <br />T <br />E <br />\ <br />2 <br />2 <br />8 <br />0 <br />1 <br />1 <br />_ <br />R <br />2 <br />0 <br />\ <br />3 <br />R <br />D <br />- <br />B <br />_ <br />A <br />R <br />C <br />H <br />_ <br />W <br />E <br />S <br />T <br />_ <br />R <br />2 <br />0 <br />. <br />r <br />v <br />t <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />301 N. Broadway, Santa Ana, CA <br />06/13/2022 Issue for Plan Check <br />A 08/10/2022 Reissue for Plan Check <br />B 06/17/2024 Revision to Permit <br />ENLARGED ELECTRICAL LIGHTING PLAN - <br />LEVEL 1 EAST LOBBY <br />SHEET NOTES <br />GENERAL NOTES <br />1/16/2025