My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Apt TI - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Apt TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:47 AM
Creation date
2/13/2026 5:00:39 AM
Metadata
Fields
Template:
Plan
Permit Number
101120329
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DESCRIPTIONSYMBOL <br />VALVES & GAUGES <br />DESCRIPTIONSYMBOL <br />GENERAL <br />HVAC LEGENDABBREVIATIONS <br />DESCRIPTIONSYMBOL <br />DUCTWORK <br />DESCRIPTIONSYMBOL <br />HYDRONIC <br />DESCRIPTIONSYMBOL <br />PIPING <br />DESCRIPTIONSYMBOL <br />MISCELLANEOUS <br />DESCRIPTIONSYMBOL <br />CONTROLS <br />150 <br />MECHANICAL DRAWING LIST <br />NEW WORK <br />EXISTING WORK TO REMAIN <br />EXISTING WORK TO BE REMOVED <br />FUTURE WORK <br />EXISTING RELOCATED <br />CENTER LINE <br />POINT OF CONNECTION OR <br />POINT OF DISCONNECTION <br />DETAIL 1, DRAWING M-1 <br />SECTION A, DRAWING M-1 <br />ELEVATION 1, DRAWING M-1 <br />RISER IDENTIFICATION <br />EXHAUST #1 <br />EQUIPMENT IDENTIFICATION <br />HEAT PUMP UNIT #1 <br />KITCHEN EQUIPMENT TAG <br />KEYED NOTE <br />DIRECTION OF TRANSFER AIRFLOW (150 CFM) <br />78 DEGREES FAHRENHEIT <br />(ER) <br />1 <br />M-1 <br />A <br />M-1 <br />1 <br />M-1 <br />EXH <br />1 <br />HP <br />1 <br /># <br />78°F <br />DIRECTION OF SLOPE <br />DIRECTION OF FLOW <br />PIPE UP (OR UP & DOWN WITH NOTATION) <br />PIPE DOWN <br />PIPE DROP/PIPE RISE <br />TOP CONNECTION - BRANCH LINE <br />BOTTOM CONNECTION - BRANCH LINE <br />PIPE ANCHOR <br />TEE UP <br />TEE DOWN <br />STRAINER <br />STRAINER WITH BLOW OFF <br />INLINE PUMP <br />BASE MOUNTED PUMP <br />TEST TAP (PETE'S PLUG) <br />MANUAL AIR VENT <br />AUTOMATIC AIR VENT <br />VACUUM BREAKER <br />VENT THRU ROOF <br />PIPE GUIDE <br />EXPANSION JOINT <br />FLEXIBLE CONNECTOR <br />UNION <br />CAPPED OR PLUGGED TEE <br />BLIND FLANGE, CAP <br />CONCENTRIC REDUCER <br />EXPANSION LOOP <br />VALVE ON RISE <br />PIPE SIZE (DIAMETER IN INCHES) <br />REFRIGERANT DISCHARGE <br />REFRIGERANT SUCTION <br />PNEUMATIC CONTROL VALVE <br />AIR LINE <br />SOUND TRAP <br />COOLING COIL <br />HEATING COIL <br />RADIANT HEATER <br />BASEBOARD HEATER <br />CHILLED BEAM <br />THRUST BLOCK <br />TEMPERATURE SENSOR <br />THERMOSTAT OR THERMOMETER <br />CARBON DIOXIDE SENSOR <br />OCCUPANCY SENSOR <br />HUMIDITY SENSOR OR HUMIDISTAT <br />STATIC PRESSURE SENSOR <br />REFRIGERANT SENSOR <br />CARBON MONOXIDE SENSOR <br />HYDROGEN SENSOR <br />DUCT SMOKE DETECTOR <br />TEMPERATURE SENSOR <br />STATIC PRESSURE SENSOR <br />PRESSURE SENSOR OR SWITCH <br />DIFFERENTIAL PRESSURE SENSOR <br />AIR FLOW MEASURING STATION <br />HUMIDITY SENSOR <br />FLOW SENSOR OR SWITCH <br />FLOW METER <br />CURRENT SENSOR <br />MOTOR <br />ACTUATOR <br />HYDROGEN MONITOR <br />REFRIGERANT MONITOR <br />ANALOG INPUT <br />ANALOG OUTPUT <br />DIGITAL INPUT <br />DIGITAL OUTPUT <br />BUILDING AUTOMATION SYSTEM <br />PULSING INPUT <br />CHILLED WATER SUPPLY <br />CHILLED WATER RETURN <br />HEATING WATER SUPPLY <br />HEATING WATER RETURN <br />CONDENSER WATER SUPPLY <br />CONDENSER WATER RETURN <br />BALL VALVE <br />SOLENOID CONTROL VALVE <br />PRESSURE AND TEMP. RELIEF VALVE <br />BUTTERFLY VALVE <br />MOTORIZED BUTTERFLY VALVE <br />GATE VALVE <br />BALANCING VALVE <br />ANGLE GATE VALVE <br />GLOBE VALVE <br />ANGLE GLOBE VALVE <br />CHECK VALVE <br />2-WAY CONTROL VALVE <br />3-WAY CONTROL VALVE <br />NON-SLAM WAFER CHECK VALVE <br />PRESSURE REDUCING VALVE (PRV) <br />DIAPHRAGM VALVE <br />LOCK SHIELD VALVE <br />NEEDLE VALVE <br />QUICK OPENING VALVE <br />VENTURI FLOW METER <br />PRESSURE GAUGE <br />PRESS. GAUGE WITH COCK AND SNUBBER <br />THERMOMETER <br />ACCESS DOOR / ACCESS PANEL <br />FLEXIBLE CONNECTION <br />FLEXIBLE DUCT RUNOUT TO DIFFUSER <br />RECTANGULAR DUCT SIZE <br />(WIDTH x DEPTH IN INCHES) <br />ROUND DUCT SIZE <br />(DIAMETER IN INCHES) <br />OVAL DUCT SIZE <br />(WIDTH x DEPTH IN INCHES) <br />DUCT THROUGH BEAM PENETRATION <br />DUCT OFFSET (RISE OR DROP) <br />VOLUME DAMPER OR REMOTE VOLUME DAMPER <br />FIRE, SMOKE OR FIRE/SMOKE DAMPER <br />SUPPLY DUCT UP <br />SUPPLY DUCT DOWN <br />EXHAUST DUCT UP <br />EXHAUST DUCT DOWN <br />RETURN DUCT UP <br />RETURN DUCT DOWN <br />CROSS SECTION OF SUPPLY DUCT <br />CROSS SECTION OF EXHAUST AIR DUCT <br />CROSS SECTION OF RETURN AIR DUCT <br />CROSS SECTION OF ROUND DUCT <br />DUCT ELBOW WITH TURNING VANES <br />SMOOTH RADIUS DUCT ELBOW WITHOUT TURNING <br />VANES <br />CONICAL BRANCH FITTING <br />45 DEGREE BOOT LO-LOSS BRANCH FITTING <br />WYE BRANCH FITTING <br />ACOUSTICAL LINING DUCT <br />(DIMENSION IS INSIDE DIMENSION) <br />MOTORIZED DAMPER INSIDE DUCT <br />TRANSFER DUCT (WITH LINER) <br />INDICATES 8'11" TO BOTTOM OF DUCT <br />RECTANGULAR OR ROUND SUPPLY DIFFUSER <br />OR REGISTER (SEE SCHEDULE). 4-WAY THROW <br />UNLESS INDICATED OTHERWISE. EXAMPLE: <br />SB12X12-400 REFERS TO TAG SB WITH <br />12"X12" NECK AND 400 CFM <br />RECTANGULAR OR ROUND EXHAUST GRILLE OR <br />REGISTER (SEE SCHEDULE) <br />RECTANGULAR OR ROUND RETURN GRILLE OR <br />REGISTER (SEE SCHEDULE) <br />WALL SUPPLY GRILLE OR REGISTER (SEE SCHEDULE) <br />WALL RETURN OR EXHAUST GRILLE OR REGISTER (SEE <br />SCHEDULE) <br />LINEAR SLOT DIFFUSER (SEE SCHEDULE FOR NUMBER <br />OF SLOTS ). 2-WAY THROW UNLESS NOTED <br />OTHERWISE. EXAMPLES: SN10-48-250 REFERS TO TAG <br />SN WITH 10" ROUND NECK, 48" SLOT LENGTH AND 250 <br />CFM. <br />VARIABLE AIR VOLUME TERMINAL UNIT <br />VARIABLE AIR VOLUME TERMINAL UNIT W/ REHEAT <br />FAN POWERED TERMINAL UNIT <br />FAN POWERED TERMINAL UNIT W/ REHEAT <br />AD/AP <br />TS <br />6" <br />RD <br />RS <br />A <br />CHWS <br />CHWR <br />HWS <br />HWR <br />CWS <br />CWR <br />(E) <br />(D) <br />AI <br />AO <br />DI <br />DO <br />BAS <br />PI <br />ST <br />CC <br />HC <br />RHT <br />BHT <br />CB <br />12x6 <br />18ø <br />24x12ø <br />VD RVD <br />FD SD FSD <br />12x6 <br />8' - 11" BOD <br />TAG NECK SIZE-CFM <br />TAG NECK SIZE-CFM <br />TAG NECK SIZE-CFM <br />TAG NECK SIZE-CFM <br />TAG NECK SIZE-CFM <br />TAG NECK SIZE-CFM <br />TAG NECK SIZE-LENGTH-CFM <br />1 <br />M <br />R D <br />(F) <br />NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS ARE APPLICABLE TO THIS <br />PROJECT. REFER TO DETAILS AND NOTES FOR MOUNTING HEIGHTS. <br />T <br />CO2 <br />H <br />SP <br />RS <br />CO <br />H <br />TS <br />DSD <br />SP <br />PS <br />DPS <br />AFMS <br />FS <br />FM <br />CS <br />M <br />A <br />HM <br />RM <br />OS <br />TS <br />HS <br />EQ <br />U <br />I <br />P <br />M <br />E <br />N <br />T <br /> <br />/ <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br /> <br />D <br />E <br />V <br />I <br />C <br />E <br />WA <br />L <br />L <br /> <br />/ <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br />MO <br />U <br />N <br />T <br />E <br />D <br /> <br />D <br />E <br />V <br />I <br />C <br />E <br />AAV AUTOMATIC AIR VENT <br />AC AIR CONDITIONING <br />ACCEPT ACCEPTANCE <br />ACCU AIR COOLED CONDENSING UNIT <br />ACU AIR CONDITIONING UNIT <br />AD ACCESS DOOR <br />AFF ABOVE FINISHED FLOOR <br />AFMS AIR FLOW MEASURING STATION <br />AFUE ANNUAL FUEL UTILIZATION EFFICIENCY <br />AG AIR GAP <br />AHJ AUTHORITY HAVING JURISDICTION <br />AHU AIR HANDLING UNIT <br />AMB AMBIENT <br />A AMPERE <br />AP ACCESS PANEL <br />APPROX APPROXIMATELY <br />ARCH ARCHITECT <br />ARI AMERICAN REFIRGERATION INSTITUTE <br />AS AIR SEPARATOR <br />AUTO AUTOMATIC <br />AUX AUXILIARY <br />B BOILER <br />BAS BUILDING MANAGEMENT SYSTEM <br />BCC BRANCH CIRCUIT CONTROLLER <br />BDD BACKDRAFT DAMPER <br />BHP BRAKE HORSEPOWER <br />BOD BOTTOM OF DUCT <br />BOP BOTTOM OF PIPE <br />BFP BACKFLOW PREVENTER <br />BSMT BASEMENT <br />BTU BRITISH THERMAL UNIT <br />BTUH BTU PER HOUR <br />BV BALL VALVE OR BALANCING VALVE <br />BYV BUTTERFLY VALVE <br />C COMMON, CONDENSATE OR CONDUIT <br />CA CONTROL AIR <br />CAP CAPACITY <br />CAV CONSTANT AIR VOLUME <br />CB CHILLED BEAM <br />CC COOLING COIL OR CONTROLS CONTRACTOR <br />CEG CEILING EXHAUST GRILLE <br />CER CEILING EXHAUST REGISTER <br />CFF CAP FOR FUTURE <br />CFM CUBIC FEET PER MINUTE <br />CFS CUBIC FEET PER SECOND <br />CHWP CHILLED WATER PUMP <br />CHWR CHILLED WATER RETURN <br />CHWS CHILLED WATER SUPPLY <br />CH CHILLER <br />CHV CHECK VALVE <br />CL CENTERLINE <br />CLG CEILING <br />CO CLEANOUT <br />CONN CONNECTION <br />CONT CONTINUATION <br />CONTR CONTRACTOR <br />COP COEFFICIENT OF PERFORMANCE <br />CP CONTROL PANEL OR CONDENSATE PUMP <br />CR CONDENSATE RETURN <br />CRG CEILING RETURN GRILLE <br />CRR CEILING RETURN REGISTER <br />CSD CEILING SUPPLY DIFFUSER <br />CTE CONNECT TO EXISTING <br />CUFT CUBIC FEET <br />CUIN CUBIC INCHES <br />CV CONSTANT VOLUME OR CONTROL VALVE <br />CW COLD WATER <br />CWP CONDENSER WATER PUMP <br />CWR CONDENSER WATER RETURN <br />CWS CONDENSER WATER SUPPLY <br />DBT DRY BULB TEMPERATURE <br />DDC DIRECT DIGITAL CONTROL <br />DIA DIAMETER <br />DIFF DIFFERENCE <br />DN DOWN <br />DP DIFFERENTIAL PRESSURE <br />DPT DEW POINT TEMPERATURE <br />DSD DUCT SMOKE DETECTOR <br />DWG(S) DRAWINGS(S) <br />DX DIRECT EXPANSION <br />(E) EXISTING <br />EA EXHAUST AIR OR EACH <br />EAD EXHAUST AIR DAMPER <br />EAT ENTERING AIR TEMPERATURE <br />EC ELECTRICAL CONTRACTOR <br />ECON ECONOMIZER <br />EDB ENTERING DRY BULB TEMPERATURE <br />EWT ENTERING WATER TEMPERATURE <br />EER ENERGY EFFICIENCY RATING <br />EF EXHAUST FAN <br />EFF EFFICIENCY <br />ELEC ELECTRICAL <br />EQUIP EQUIPMENT <br />(ER) EXISTING RELOCATED <br />ESP EXTERNAL STATIC PRESSURE <br />ET EXPANSION TANK <br />EWB ENTERING WET BULB TEMPERATURE <br />EXH EXHAUST <br />EXT EXTERNAL <br />F FAHRENHEIT <br />FPB FAN POWERED BOX <br />FC FLEXIBLE CONNECTION OR FAIL CLOSED <br />FCU FAN COIL UNIT <br />FD FIRE DAMPER <br />FF FINAL FILTER OR FINISHED FLOOR <br />FFA/FFB FROM FLOOR ABOVE/BELOW <br />FO FAIL OPEN <br />FPI FINS PER INCH <br />FPM FEET PER MINUTE <br />FPS FEET PER SECOND <br />FSD FIRE/SMOKE DAMPER <br />FT FOOT OR FEET <br />GA GAUGE <br />GAL GALLONS <br />GALV GLAVANIZED <br />GC GENERAL CONTRACTOR <br />GLV GLOBE VALVE <br />GPM GALLONS PER MINUTE <br />GND GROUND <br />GV GATE VALVE <br />H HEIGHT <br />HB HOSE BIBB <br />HC HEATING COIL <br />HD HEAD <br />HOR HORIZONTAL <br />HP HIGH PRESSURE <br />HP HORSEPOWER <br />HP HEAT PUMP <br />HPC HIGH PRESSURE CONDENSATE <br />HPS HIGH PRESSURE STEAM <br />HR HOUR(S) <br />HRU HEAT RECOVERY UNIT <br />HS HUMIDITY SENSOR <br />HV HOSE VALVE <br />HVAC HEATING, VENTILATING AND AIR CONDITIONING <br />HW HEATING WATER <br />HWP HEATING WATER PUMP <br />HWR HEATING WATER RETURN <br />HWS HEATING WATER SUPPLY <br />HX HEAT EXCHANGER <br />HZ FREQUENCY (HERTZ) <br />ID INSIDE DIAMETER <br />IDU INDOOR UNIT (VRF) <br />IN INCH(ES) <br />INPLV INTEGRATED PART LOAD VALUE <br />KE KITCHEN EXHAUST DUCT <br />KW KILOWATT <br />KWH KILOWATT HOUR <br />L LENGTH <br />LAT LEAVING AIR TEMPERATURE <br />LBS POUNDS <br />LDB LEAVING DRY BULB <br />LF LINEAR FEET <br />LP LOW PRESSURE <br />LPC LOW PRESSURE CONDENSATE <br />LPS LOW PRESSURE STEAM <br />LWB LEAVING WET BULB <br />LWT LEAVING WATER TEMPERATURE <br />M MOTOR <br />MA MIXED AIR <br />MAD MIXED AIR DAMPER <br />MAX MAXIMUM <br />MBH THOUSAND BTU PER HOUR <br />MC MECHANICAL CONTRACTOR <br />MCA MINIMUM CIRCUIT AMPACITY <br />MCC MOTORIZED CONTROL CENTER <br />MD MOTORIZED DAMPER <br />MECH MECHANICAL <br />MERV MINIMUM EFFICIENCY RATING VALUE <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MOCP MINIMUM OVER CURRENT PROTECTION <br />MV MANUAL AIR VENT <br />(N) NEW <br />N/A NOT APPLICABLE <br />NC NORMALLY CLOSED <br />NIC NOT IN CONTRACT <br />NO NORMALLY OPEN OR NUMBER <br />NOM NOMINAL <br />NPSH NET POSITIVE SUCTION HEAD <br />NTS NOT TO SCALE <br />OA OUTSIDE AIR <br />OAD OUTSIDE AIR DAMPER <br />OAT OUTSIDE AIR TEMPERATURE <br />OBD OPPOSED BLADE DAMPER <br />OC ON CENTER <br />OD OUTSIDE DAMPER <br />ODU OUTDOOR UNIT (VRF) <br />OFCI OWNER FURNISHED CONTRACTOR INSTALLED <br />OFOI OWNER FURNISHED OWNER INSTALLED <br />OPER OPERATING <br />OV OUTLET VELOCITY <br />P PUMP OR PRESSURE OR POLE <br />PC PUMPED CONDENSATE <br />PD PRESSURE DROP <br />PF PREFILTER <br />PG PIPE GUIDE OR PRESSURE GAUGE <br />PH PHASE (ELECTRICAL) <br />PHC PREHEAT COIL <br />POC POINT OF CONNECTION <br />POD POINT OF DISCONNECTION <br />PRESS PRESSURE <br />PRV PRESSURE REDUCING VALVE <br />PS PRESSURE SENSOR <br />PSI POUNDS PER SQUARE INCH <br />PSIA PSI ABSOLUTE <br />PSIG PSI GAUGE <br />QTY QUANTITY <br />R RELOCATE, RISE, RISER <br />RA RETURN AIR <br />RAD RETURN AIR DAMPER <br />RD REFRIGERANT DISCHARGE <br />REF ROOFTOP EXHAUST FAN <br />REFRIG REFRIGERATION <br />REV REVISE, REVISION OR REVOLUTIONS <br />RF RETURN FAN <br />RH RELATIVE HUMIDITY <br />RHC REHEAT COIL <br />RHT RADIANT HEATER <br />RPM REVOLUTIONS PER MINUTE <br />RS REFRIGERANT SUCTION <br />RTU ROOFTOP UNIT <br />S SUPPLY OR SLOPE <br />SA SUPPLY AIR <br />SCFM CFM, STANDARD CONDITIONS <br />SD SMOKE DAMPER <br />SEER SEASONAL ENERGY EFFICIENCY RATING <br />SEN SENSIBLE <br />SF SUPPLY FAN OR SQUARE FEET <br />SIU SPLIT INDOOR UNIT <br />SOU SPLIT OUTDOOR UNIT <br />SP STATIC PRESSURE <br />SPD SPLITTER DAMPER <br />SPEC SPECIFICATIONS <br />SQ IN SQUARE INCH <br />ST STRAINER OR SOUND TRAP <br />STD STANDARD <br />T THERMOSTAT (NOT TEMPERATURE SENSOR) <br />T THERMOMETER <br />TA TRANSFER AIR <br />TCP TEMPERATURE CONTROL PANEL <br />TD TRANSFER DUCT <br />TDH TOTAL DYNAMIC HEAD <br />TE TOILET EXHAUST DUCT <br />TEMP TEMPERATURE <br />TFA/TFB TO FLOOR ABOVE/BELOW <br />TI TENANT IMPROVEMENT <br />TRG TRANSFER GRILLE <br />TS TEMPERATURE SENSOR <br />TSP TOTAL STATIC PRESSURE <br />TT TEST TAP OR TEST TEE <br />TXV THERMAL EXPANSION VALVE <br />(TYP) TYPICAL <br />U HEAT TRANSFER COEFFICIENT <br />UG UNDERGROUND <br />UH UNIT HEATER <br />UON UNLESS OTHERWISE NOTED <br />V VENT OR VOLUME OR VELOCITY <br />VAV VARIABLE AIR VOLUME <br />VB VACUUM BREAKER <br />VD VOLUME DAMPER <br />VEL VELOCITY <br />VERT VERTICAL <br />VFD VARIABLE FREQUENCY DRIVE <br />VOL VOLUME <br />W WASTE OR WIDTH OR WATTS <br />W/ WITH <br />W/O WITHOUT <br />WB WET BULB TEMPERATURE <br />WC WATER COLUMN <br />WEG WALL EXHAUST GRILLE <br />WG WATER GAUGE <br />WP WORKING PRESSURE <br />WPD WATER PRESSURE DROP <br />WRR WALL RETURN REGISTER <br />WSHP WATER-SOURCE HEAT PUMP <br />WSR WALL SUPPLY REGISTER <br />WT WEIGHT <br />Z ZONE <br />ZD ZONE DAMPER <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />EXP: 12/31/2025 <br />N.T.S <br />6/14/2024 2:08:07 AM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/228011-04_3RD-B_MECH_R20.rvt <br />R2.M0.0 <br />MECHANICAL SYMBOLS,NOTES AND <br />ABBREVIATIONS <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />R2-M9.003 MECHANICAL DETAILS X <br />R2-M9.002 MECHANICAL DETAILS X <br />R2-M9.001 MECHANICAL DETAILS X <br />R2-M6.005 REFRIGERANT PIPING SCHEMATIC DIAGRAM X <br />R2-M6.004 REFRIGERANT PIPING SCHEMATIC DIAGRAM X <br />R2-M6.003 REFRIGERANT PIPING SCHEMATIC DIAGRAM X <br />R2-M6.002 REFRIGERANT PIPING SCHEMATIC DIAGRAM X <br />R2-M6.001 REFRIGERANT PIPING SCHEMATIC DIAGRAM X <br />R2-M4.116 REFRIGERANT PIPING PLAN - ROOF X <br />R2-M4.115 REFRIGERANT PIPING PLAN - LEVEL 15 X <br />R2-M4.108 REFRIGERANT PIPING PLAN - LEVEL 08 - LEVEL 14 X <br />R2-M4.107 REFRIGERANT PIPING PLAN - LEVEL 07 X <br />R2-M4.106 REFRIGERANT PIPING PLAN - LEVEL 06 X <br />R2-M4.105 REFRIGERANT PIPING PLAN - LEVEL 05 X <br />R2-M4.102 REFRIGERANT PIPING PLAN - LEVEL 02 X <br />R2-M4.101 REFRIGERANT PIPING PLAN - LEVEL 01 X <br />R2-M3.115 HVAC ZONING PLAN - LEVEL 15 X <br />R2-M3.108 HVAC ZONING PLAN - LEVEL 08 - LEVEL 14 X <br />R2-M3.107 HVAC ZONING PLAN - LEVEL 07 X <br />R2-M3.106 HVAC ZONING PLAN - LEVEL 06 X <br />R2-M3.101 HVAC ZONING PLAN - LEVEL 01 X <br />R2-M2.115 MECHANICAL DUCTWORK PLAN - LEVEL 15 X <br />R2-M2.108 MECHANICAL DUCTWORK PLAN - LEVEL 08 - LEVEL 14 X <br />R2-M2.107 MECHANICAL DUCTWORK PLAN - LEVEL 07 X <br />R2-M2.106 MECHANICAL DUCTWORK PLAN - LEVEL 06 X <br />R2-M2.101 MECHANICAL DUCTWORK PLAN - LEVEL 01G X <br />R2-M0.7 ENERGY CALCULATIONS X <br />R2-M0.6 ENERGY CALCULATIONS X <br />R2-M0.5 ENERGY CALCULATIONS X <br />R2-M0.4 MECHANICAL SCHEDULES X <br />R2-M0.3 MECHANICAL SCHEDULES X <br />R2-M0.2 MECHANICAL SCHEDULES X <br />R2-M0.1 BASIS OF DESIGN AND GENERAL NOTES X <br />R2-M0.0 MECHANICAL SYMBOLS,NOTES AND ABBREVIATIONS X <br />SHEET <br />NUMBER SHEET NAME <br />IS <br />S <br />U <br />E <br /> <br />F <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> 0 <br />6 <br />. <br />1 <br />7 <br />. <br />2 <br />0 <br />2 <br />4 <br />PROJECT No. 228011.04 MECHANICAL DRAWING LIST <br />3RD & BROADWAY RESIDENTIAL TOWER <br />2 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />1 08.10.2022 REISSUE FOR PLAN CHECK <br />2 06.17.2024 REVISION TO PERMIT <br />1/15/2025 <br />Revision to 40136842 (issued on <br />12/1/2023) <br />Rev #40139372 <br />APPROVALS: <br />MECH - CSG
The URL can be used to link to this page
Your browser does not support the video tag.