Laserfiche WebLink
DESIGNED BY: <br />REVISED BY: <br />REVISIONS: <br />DATE:BY: <br />PROJECT: <br />A PROJECT FOR: <br />PROJECT ADDRESS: <br />SHEET TITLE <br />DATE: <br />SHEET: <br />PROJECT INFO <br />PROJECT # <br />DRAWN BY: <br />CHECKED BY: <br />SCALE: <br />AS SHOWN <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />29 <br />2 <br />3 <br /> <br />W <br /> <br />R <br />A <br />Y <br />M <br />A <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />- <br />U <br />N <br />I <br />T <br /># <br />2 <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />SANTA ANA, CA 92704 <br />2923 W RAYMAR STREET-UNIT#2 <br />DESIGN ENGINEER: VISAL TE <br />LEGEND <br />Ceiling fixture <br />Wall mounted light <br />C <br />SD <br />Silent toggle switch <br />F Ventilation fan 60 cfm min. with humidistat <br />30" CLR <br />24 <br />" <br /> <br />C <br />L <br />R <br />1 <br />1 <br />2 <br /> and shall be installed in accordance with NFPA 72 <br />Carbon monoxide hard wired with battery backup <br />and shall be installed in accordance with NFPA 72 <br />Smoke detector hard wired with battery backup <br />G <br />Duplex convenient GFCI outlet, tamper-resistant <br />Duplex convenient AFCI outlet, tamper-resistant <br />(N) 4' X 4' SLIDING WINDOW U-0.3 SHG-0.23 <br />insulated door <br />(N) 3'-0" X 6'-8" exterior door, 0.2. AN NFRC <br />AND SECTION <br />FLOOR PLAN, ROOF PLAN <br />(N) 32" X 6'-8" hollow core interior door <br />2 (N) 3' X 1'-6" SLIDING WINDOW U-0.3 SHG-0.23 <br />A-2 <br />A-2 <br />15" <br />NFRC window labels to be removed only by owners after final building inspectiond. <br />room without the use of keys, tools or special knowledge (R310.1.1 <br />Emergency escape and rescue openings shall be clear of any obstruction and operational from the inside of the c. <br />opening not greater than 44 inches measured from the floor (R310.2.2). <br />Where a window is provided as the emergency escape and rescue opening, it shall have the bottom of the clear b. <br />minimum net clear opening height of 24 inches and width of 20 inches (R310.2.1). <br />All emergency escape and rescue openings shall have a minimum clear opening of 5.7 square feet with a a. <br />NOTE: <br />SCALE: 1/4" = 1' <br />PROPOSED FLOOR PLAN <br />SCALE: 1/4" = 1'SCALE: 1/4" = 1' <br />1 HR FIRE WALL <br />STC 50- SOUND WALL <br />3' <br /> <br />0 <br />" <br />2' x 6' <br />CLOSET <br />9' 10" <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />( <br />F <br />E <br />N <br />C <br />E <br />) <br />AND VERTICALLY <br />HORIZONTALLY <br />BLOCKING AT 10'-0" <br />PROVIDE FIRE <br />SEE STRUCTURAL DRAWING <br />MIN 2x4 STOUS AT 24" O.C., <br />BATT INSULATION <br />3" MIN, <br />EACH SIDE <br />TYPE 'X'GYP, BD. <br />1 LAYER 5/8" <br />TO JOISTS AT 16" O.C. <br />PERPENDICULAR <br />RESILENET CHANNELS <br />(E) MAIN HOUSE <br />(E) WALL <br />(E) WALL TO BE DEMOLISHED <br />(N) WALL <br />3' X 6' <br />SHOWER <br />13 <br />' <br /> <br />5 <br />" <br />11 <br />' <br /> <br />7 <br />" <br />Silent toggle switch with motion sensorV <br />3' x 3' <br />LANDING <br />3 sones max. <br />100 cfm min. <br />Provide kitchen hood <br />R-21 insulation <br />R-15 insulation <br />BEDROOM <br />LIVING ROOM <br />LIVING ROOM <br />BATHROOMKITCHEN <br />BEDROOM <br />IN-FILLED WALL <br />IN-FILLED WALL <br />(FOR ADU) <br />WATER HEATER <br />(N) TANKLESS <br />(N) MINI SPLIT UNIT <br />(N) ELECTRIC PANEL <br />STC 50-SOUND WALL <br />1HR FIRE WALL <br />W/D <br />Stackable <br />1 1 <br />2 <br />1 2 <br />2 <br />10' 2" <br />7' <br /> <br />7 <br />" <br />3' 6" <br />20" x 30" <br />ARTIC ACCESS <br />(E) GATE <br />BEDROOM BEDROOM <br />DINING ROOMKITCHEN <br />BATH <br />BATH <br />C <br />SD <br />SD <br />G G G <br />G <br />FV <br />V <br />SCALE: 1/4" = 1' <br />CROSS SECTION <br />R-15 insulation <br />BEDROOMLIVING ROOM <br />R-15 insulation R-21 insulation STC 50- SOUND WALL <br />1 HR FIRE WALL <br />SCALE: 1/4" = 1' <br />CROSS SECTION <br />TEMP <br />(N) 1 HR FIRE WALL <br />R-15 insulation <br />R-15 insulation <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />( <br />F <br />E <br />N <br />C <br />E <br />) <br />BEDROOM BEDROOM <br />LIVING ROOM <br />(E) MAIN HOUSE <br />BATH <br />BEDROOM <br />BATH <br />KITCHEN DINING ROOM <br />SCALE: 1/4" = 1' <br />EXISTING FLOOR PLAN <br />(E) GATE <br />(E) WINDOW 10' x 4' <br />C <br />A-2 <br />A-A <br />A-2 <br />B-B <br />A-2 <br />C <br />A-2 <br />A-A <br />A-2 <br />B-B <br />A-2 <br />2/2/2025 <br />DIGITAL <br />100 amp.