DESIGNED BY:
<br />REVISED BY:
<br />REVISIONS:
<br />DATE:BY:
<br />PROJECT:
<br />A PROJECT FOR:
<br />PROJECT ADDRESS:
<br />SHEET TITLE
<br />DATE:
<br />SHEET:
<br />PROJECT INFO
<br />PROJECT #
<br />DRAWN BY:
<br />CHECKED BY:
<br />SCALE:
<br />AS SHOWN
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />4
<br />29
<br />2
<br />3
<br />
<br />W
<br />
<br />R
<br />A
<br />Y
<br />M
<br />A
<br />R
<br />
<br />S
<br />T
<br />R
<br />E
<br />E
<br />T
<br />-
<br />U
<br />N
<br />I
<br />T
<br />#
<br />2
<br />AC
<br />C
<br />E
<br />S
<br />S
<br />O
<br />R
<br />Y
<br />
<br />D
<br />W
<br />E
<br />L
<br />L
<br />I
<br />N
<br />G
<br />
<br />U
<br />N
<br />I
<br />T
<br />SANTA ANA, CA 92704
<br />2923 W RAYMAR STREET-UNIT#2
<br />AND SECTION
<br />FLOOR PLAN, ROOF PLAN
<br />A-2
<br />A-3
<br />VENTULATION CALCULATION
<br />
<br />Provided: (4) 12x24 domer vent - cover 576 sq. inches
<br />506 sf/150 = 3.37 sf or 485.76 sq. inches
<br />Roof area= 22 x 23 = 506 sf
<br />4:12
<br />SCALE: 1/4" = 1'
<br />EAST VIEW
<br />SCALE: 1/4" = 1'
<br />WEST VIEW
<br />SCALE: 1/4" = 1'
<br />SOUTH VIEW
<br />8"
<br />7'
<br />
<br />4
<br />"
<br />5'
<br />
<br />1
<br />"
<br />12" x 24"
<br />DOMER VENT
<br />SCALE: 1/4" = 1'
<br />ROOFVIEW
<br />4:12
<br />2'
<br />
<br />8
<br />"
<br />2'
<br />
<br />8
<br />"
<br />5'
<br />
<br />2
<br />"
<br />4'x4'
<br />WINDOW
<br />(EGRESS)
<br />4'x4'
<br />WINDOW
<br />3'x1'6"
<br />WINDOW
<br />(E) ROOF 12" x 24"
<br />DOMER VENT
<br />ASTM D1758
<br />ASPHALT SHINGLE
<br />(E) ROOF
<br />FORMALEHYDE EMISSION STANDARDS.
<br />PARTICLE BOARD, MEDIUM DENSITY FIBERBOAD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW
<br />GREEN BUILDING STANDARD CODE, SECTION 4. 504. 4
<br />(VOLOTILE ORGANIC COMPOUND) LIMITS. SEE CALIFORNIA80 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH VOC
<br />DOCUMENTATIONS SHALL BE PROVIDED TO VERIFY THAT COMPLAINT VOC (VOLOTILE ORGANIC COMPOUND) LIMIT FINISH MATERIALS HAVE BEEN USED.
<br />MANUALS ARE TO REMAIN WITH THE BUILDING THROUGHOUT THE LIFE CYCLE OF THE STRUCTURE.
<br />OPERATION AND MAINTENANCE INSTRUCTIONS FOR ALL EQUIPMENT INSTALLED SHALL BE GIVEN TO OWNER, WITH THE INSTRUCTIONS, THAT THESE
<br />CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION AND NOTIFY DESIGNER OF ANY DISCREPANCIES.
<br /> :GENERAL NOTES
<br />1.8 GALLON/MINUTE KITCHEN FAUCETS AT 60 PSI
<br />1.2 GALLON /MINUTE LAVATORY FAUCETS AT 60 PSI
<br />2.0 GALLON/MINUTE SINGLE SHOWER HEAD AT 80 PSI*
<br />1.28 GALL/FLUSH TOILET
<br />2019 CALIFORNIA BUILDING CODE (SECTION 4.303) ARE:
<br />WATER CONSERVING PLUMBING FIXTURES & FITTINGS AS DEFINED BY
<br />WATER LINE OF TYPE "L" COPPER
<br />ALL PLUMBING FIXTURES SHALL COMPLY TO SENATE BILL 407
<br />PLUMBING REQUIREMENTS
<br />ADEQUATE STRAINER SHALL BE INSTALLED. (CPC SEC 608.2)
<br />80 PSI AN APPROVED PRESSURE REGULATOR PROCEEDED BY AN
<br />WHERE STATIC PRESSURE IN THE WATER SUPPLY PIPING IS EXCEEDING
<br />GENERAL
<br />WATER MAIN, WITH AN EXPANSION TANK. CPC SEC. 608.2 & 608.3
<br />PREVENTS DISSIPATION OF BUILDING PRESSURE BACK INTO THE
<br />BACKFLOW PREVENTER OR OTHER NORMALLY CLOSED DEVICE THAT
<br />PROVIDE WATER SYSTEM WITH A PRESSURE REGULATOR, CHECK VALVE,
<br />THAT DOES NOT CAUSE PERSONAL INJURY (CPC SEC. 608.5)
<br />INCHES ABOVEGROUND AND POINTING DOWNWARD AND DISCHARGE IN A MANNER
<br />BUILDING WITH THE END OF THE PIPE NOT MORE THAN 2’ FEET NOR LESS THAN 6”
<br />THROUGH AN AIR GAP INTO THE DRAINAGE SYSTEM OR EXTEND OUTSIDE THE
<br />THE RELIEF VALVE OUTLET, SHALL DISCHARGE INDEPENDENTLY BY GRAVITY
<br />OR COMBINATION OF BOTH SHALL BE PROVIDED WITH A DRAIN, NOT SMALLER THAN
<br />THE DISCHARGE PIPING SERVING A TEMPERATURE RELIEF VALVE, PRESSURE RELIEF
<br />1
<br />CFM WITH A CONTINUOUS OPERATING SYSTEM. CMC TABLE 403.7.
<br />SYSTEM CAPABLE OF EXHAUSTING A MINIMUM OF 100 CFM OR 50
<br />RESIDENTIAL KITCHENS SHALL BE PROVIDED WITH AN EXHAUST
<br />FROM BUILDING OPENING
<br />DAMPER TO DAYLIGHT, VENT CANNOT TERMINATE LESS THAN 3'
<br />LOCATION OF ELECTRIC DRYER VENT ON ATTIC, WITH BACKDRAFT
<br />MINI-SPLIT UNIT
<br />MIN. EACH WAY
<br />CONDENSER, PROVIDE A A 3' X 3'X4" CONCRETE PAD W. #4 REBAR 3
<br />DRAIN OR DAY LIGHT
<br />STACKED WASHER DRYER, PROVIDE METAL PAN WITH DRAIN TO
<br />WALL MOUNTED TANKLESS WATER HEATER.
<br />DISH, SHELVES, AND SAFETY GRAB BARS, OR RAILS. (CPC 408.6)
<br />PROTRUSIONS OTHER THAN THE VALVE(S), SHOWERHEAD, SOAP
<br />ABOVE THE SHOWER DRAIN OUTLET WITH NO
<br />DIMENSIONS SHALL BE MAINTAINED TO A POINT OF 70 INCHES
<br />ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH CIRCLE, THE
<br />MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES AND SHALL
<br />SHOWER COMPARTMENT REGARDLESS OF SHAPE, SHALL HAVE A
<br />PIECE FIBERGLASS SHOWER/TUB COMBO W/ TEMPERED GLASS.
<br />GASKETED TO PREVENT AIR LEAKAGE.”
<br />MECHANICAL FASTENERS. THE ATTIC ACCESS DOOR SHALL BE
<br />PERMANENTLY ATTACHED CEILING INSULATION USING ADHESIVE OR
<br />SHALL BE AT ACCESS ENTRANCE. ATTIC ACCESS DOORS SHALL HAVE
<br />LIGHT FOR MAINTENANCE OF EQUIPMENT. CONTROL OF LIGHTS
<br />PROVIDE A PERMANENT SWITCH CONTROLLED CLEARANCE 30".
<br />ATTIC ACCESS. PROVIDE A 30"x30" MIN. ATTIC ACCESS, MIN. HEAD
<br />EACH WAY.
<br />LANDING 3'x3' (4" CONCRETE SLAB) WITH#4 REBAR WITH 18" O.C.
<br />DOUBLE SINK WITH GARBAGE DISPOSAL.
<br />PROVIDE A 30" X 24" CLEAR SPACE IN FRONT OF WATER CLOSE.
<br />OWNER TO PROVIDE SHOWER HEAD AND FIXTURES.
<br />3
<br />5
<br />2
<br />6
<br />7
<br />8
<br />NOTE LEGEND
<br />10
<br />4
<br />9
<br />11
<br />12
<br />owners after final building inspection
<br />NFRC window labels to be removed only by d.
<br />knowledge (R310.1.1
<br />room without the use of keys, tools or special
<br />from the inside of the
<br />shall be clear of any obstruction and operational
<br />Emergency escape and rescue openings c.
<br />from the floor (R310.2.2).
<br />opening not greater than 44 inches measured
<br />have the bottom of the clear
<br />emergency escape and rescue opening, it shall
<br />Where a window is provided as the b.
<br />inches and width of 20 inches (R310.2.1).
<br />minimum net clear opening height of 24
<br />feet with a
<br />shall have a minimum clear opening of 5.7 square
<br />All emergency escape and rescue openings a.
<br />NOTE:
<br /> by Federal Specification HH-I-521E.
<br />determined
<br />thermal resistance R value of 11 or greater as
<br />h. 4. The mineral fiber insulation shall have a
<br />resilient channels.
<br />kitchen and bathroom areas, if ceilings are on
<br /> be substituted for carpet and padding in
<br />with 1/8" minimum thickness resilient backing may
<br />g. 3. Sheet vinyl and linoleum floor coverings
<br /> shall be as required for fire ratings.
<br />or lath
<br />and the attachment of channels and gypsum board
<br />f. 2. Type and spacing of resilient channels
<br />(2.4 pcf).
<br /> urethane foam (4 pcf), or ½" urethane foam
<br />jutted pad, or 48 oz. foam rubber, or 3/8" rebonded
<br />e. 13 oz. face wt. carpet (31 oz. tot) and 40 oz.
<br />protective guard per Section R312.
<br /> glazing is more than 18 inches from a
<br />degrees from the bottom treadnosing, unless the
<br /> 60-inch horizontal arc less than 180
<br />than 36 inches above the landing and within a
<br />bottom of a stairway where the glazing is less
<br /> g. Glazing adjacent to the landing at the
<br />per Section R308.4.6.
<br /> the walking surface, or a rail is designed
<br />36 inches or moremeasured horizontally from
<br />flights of stairs, and ramps, unless the glazing is
<br /> surface of stairways, landings between
<br />inches above the plane of the adjacent walking
<br />where the bottom exposed edge is less than 36
<br /> f. Glazing adjacent to stairs and ramps
<br />edge of a shower, sauna or steam room.
<br /> bathtub, or swimming pool, or from the
<br />the water’s edge of a hot tub, spa, whirlpool,
<br />measured horizontally and in a straight line, from
<br /> 2. The glazing is within 60 inches,
<br />surface.
<br />than 60 inches above any standing or walking
<br /> 1. The bottom edge of the glazing is less
<br />where all of the following conditions are present:
<br /> indoor or outdoor swimming pools,
<br />saunas, steam rooms, bathtubs, showers, and
<br />containing or facing hot tubs, spas, whirlpools,
<br /> e. Glazing in walls, enclosures or fences
<br /> surface.
<br />regardless of area or height above a walking
<br />baluster panels, and nonstructural in-fill panels,
<br /> d. Glazing in guards, railings, structural
<br />straight line, of the glazing.
<br />36 inches, measured horizontally and in a
<br /> 4. One or more walking surfaces are within
<br />above the floor.
<br /> 3. The top edge is more than 36 inches
<br />above the floor.
<br /> 2. The bottom edge is less than 18 inches
<br />is larger than 9 square feet.
<br /> 1. The exposed area of an individual pane
<br />conditions:
<br />operable panel, that meets all of the following
<br /> c. Window glazing in an individual fixed or
<br /> in-swinging door.
<br />an
<br />position and within 24 inches of the hinge side on
<br />perpendicular to the plane of the door in a closed
<br /> 2. Where the glazing is on a wall
<br /> closed position.
<br />a
<br />either side of the door in the plane of the door in
<br /> 1. Where the glazing is within 24 inches of
<br />the following conditions:
<br /> walking surface and it meets either of
<br />the
<br />edge of the glazing is less than 60 inches above
<br />adjacent to a door where the bottom exposed
<br /> b. Glazing in fixed or operable panels
<br />swinging, sliding, and bifold doors.
<br /> a. Glazing in fixed and operable panels of
<br />
<br />Section R308:
<br />hazardous locations requiring safety glazing per
<br /> The following shall be considered specific
<br />GLAZING NOTES:
<br />2/2/2025