Round 1 Bowling and Amusement 12/09/2024 Paradigm Design <br />Main Place Mall Expansion Grand Rapids, MI <br />Santa Ana, California <br />Project #2309147GR <br />ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 08 4113 - 5 <br />ed. 2024-02-20 <br />1.No evidence of water penetration through fixed glazing and framing areas, including entrance <br />doors, when tested in accordance with a minimum static-air-pressure differential of 20 percent <br />of positive wind-load design pressure, but not less than 10 lbf/sq. ft.. <br />G.Seismic Performance: Aluminum-framed entrance and storefront systems to withstand the effects of <br />earthquake motions determined in accordance with ASCE/SEI 7. <br />1.Seismic Drift Causing Glass Fallout: Complying with criteria for passing based on building <br />occupancy type when tested in accordance with AAMA 501.6 at design displacement and 1.5 <br />times the design displacement. <br />H.Energy Performance: Certified and labeled by manufacturer for energy performance as follows: <br />1.Thermal Transmittance (U-factor): <br />a.Fixed Glazing and Framing Areas: U-factor for the system of not more than 0.38 Btu/sq. <br />ft. x h x deg F as determined in accordance with NFRC 100 and with double glazed clear <br />solar control insulating glass unit (Solarban® 60 on clear 6mm (2) | Air 1/2" (12.7mm) | <br />Clear 6mm). <br />b.Entrance Doors: U-factor of not more than 0.61 Btu/sq. ft. x h x deg F as determined in <br />accordance with NFRC 100 and with double glazed clear solar control insulating glass <br />unit (Solarban® 60 on clear 6mm (2) | Air 1/2" (12.7mm) | Clear 6mm). <br />2.Solar Heat-Gain Coefficient (SHGC): <br />a.Fixed Glazing and Framing Areas: SHGC for the system of not more than 0.35 as <br />determined in accordance with NFRC 200. <br />b.Entrance Doors: SHGC of not more than 0.20 as determined in accordance with <br />NFRC 200. <br />3.Air Leakage: <br />a.Fixed Glazing and Framing Areas: Air leakage for the system of not more than 0.06 <br />cfm/sq. ft. at a static-air-pressure differential of 6.24 lbf/sq. ft. when tested in accordance <br />with ASTM E283. <br />b.Entrance Doors: Air leakage of not more than 1.0 cfm/sq. ft. at a static-air-pressure <br />differential of 1.57 lbf/sq. ft.. <br />4.Condensation Resistance Factor (CRF): <br />a.Fixed Glazing and Framing Areas: CRF for the system of not less than frame 69 and <br />glass 68 as determined in accordance with AAMA 1503. <br />b.Entrance Doors: CRF of not less than 57 as determined in accordance with AAMA 1503. <br />I.Noise Reduction: Test in accordance with ASTM E90, with ratings determined by ASTM E1332, as <br />follows.