Laserfiche WebLink
DN <br />S <br />S <br />F <br />F G <br />G <br />H <br />H <br />J <br />J <br />1 1 <br />2 2 <br />3 3 <br />2.5 2.5 <br />F <br />F G <br />G <br />H <br />H <br />J <br />J <br />1 1 <br />2 2 <br />2.5 2.5 <br />3 3 <br />4 4 <br />F <br />F G <br />G <br />H <br />H <br />J <br />J <br />1 1 <br />2 2 <br />2.5 2.5 <br />3 3 <br />4 4 <br />PANEL "H" (E) <br />TRANSFORMER "T-AB" (E) <br />PANEL "A" (E) <br />PANEL "B" (E) <br />CONTROL PANEL <br />(REMOVE) <br />1 <br />1 <br />1 <br />1 <br />EXISTING TRACK <br />LIGHTING (TYP.) <br />(REMOVE) <br />EXISTING EXIT <br />SIGN (TYP.) <br />(REMOVE) <br />EXISTING <br />PENDANT <br />LIGHT (TYP.) <br />(REMOVE) <br />EXISTING <br />EMERGENCY LIGHT <br />(TYP.) (REMOVE) <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 2 <br />2 <br />3 <br />3 <br />3 <br />3 <br />4 <br />4 <br />EHD EHD <br />5 <br />5 <br />5 <br />5 <br />5 <br />5 5 <br />EXISTING EXTERIOR <br />ACCENT LIGHTING <br />(TYP.)(REMOVE) <br />EXISTING <br />PENDANT <br />LIGHT (TYP.) <br />(REMOVE) <br />EXISTING SIGN <br />ACCENT PENDANT <br />LIGHT (REMOVE) <br />12/9/2024 4:09:03 PM <br />2309147GR <br />ROUND1 <br />BOWLING AND <br />AMUSEMENT <br />2800 N. MAIN ST. SUITE 1100 <br />SANTA ANA, CA 92705 <br />ROUND 1 <br />ENTERTAINMENT <br />3070 SATURN ST. STE. 200 <br />BREA, CA 92821 <br />ELECTRICAL DEMOLITION <br />PLAN <br />ED101 <br />MAINPLACE <br />MALL <br />REMODEL <br />CLIENT <br />ARCHITECTS <br />PARADIGM <br />415 Leonard Street NW, Suite 200 <br />Grand Rapids, MI 49504 <br />(616) 785-5656 <br />www.paradigmae.com <br />Grand Rapids | Phoenix | Traverse City <br />DESIGN <br />ENGINEERS| <br />DATE DESCRIPTION <br />RELEASE DATE <br />SHEET <br />PROJECT <br />PROJECT <br />12-09-24 Permits <br />SCALE:1/8" = 1'-0"ED101 <br />ENLARGED ELECTRICAL DEMOLITION PLAN1 <br />5 EXPANSION AREA SHALL, DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES <br />AND LIGHITNG AS REQURIED TO ALLOW FOR RENOVATION. <br />4 EXISTING FIRE ALARM DEVICE SHALL BE REMOVED AND RELOCATED TO NEW <br />LOCATION AS FEASABLE FOR RENOVATION. <br />3 EXISTING LIGHTING SHALL BE REMOVED AND RELOCATED AS SHOWN ON <br />REVISED PLAN. <br />2 EXISTING LIGHITNG OR DEVICE SHALL REMAIN, SHOWN FOR REFERENCE. <br />1 EXISTING ELECTRICAL GEAR SHALL REMAIN FOR REUSE. <br />LEGEND SYMBOL INDICATOR <br />ELECTRICAL DEMOLITION PLAN NOTES <br />I (E) DENOTES EXISTING <br />H REFER TO SHEET MD-105 FOR DEMOLITION OF ROOF MOUNTED HVAC EQUIPMENT. <br />DISCONNECT TO ALLOW FOR SAFE REMOVAL. REFER TO ONE LINE DIAGRAM FOR ROOF <br />TOP UNITS. NOTE WIRING FROM EXISTING MAIN LEVEL ANCHOR TENANT TO ROOF MAY <br />BE REUSED IN NEW CONSTRUCTION PHASE, COORDINATE WITH FINAL NEW <br />CONSTRUCTION PHASE DRAWINGS FOR FINAL DETERMINATION ON WIRING/EQUIPMENT <br />FEEDER REMOVAL. <br />G PROVIDE AND MAINTAIN TEMPORARY POWER AND LIGHTING ADEQUATE FOR SAFE <br />WORKING CONDITIONS. PROVIDE A MINIMUM OF 40 LUMENS PER SQUARE FOOT. <br />MAINTAIN A STOCK OF SPARE LAMPS AND FIXTURES AT THE JOB SITE TO ENSURE THAT <br />SAFE LIGHT LEVELS ARE MAINTAINED AT ALL TIMES. USE OF STRING LIGHTS AND/OR <br />WOBBLE LIGHTS WILL NOT BE PERMITTED WITHOUT APPORVAL OF THE GENERAL <br />CONTRACTOR FIELD MANAGER. <br />F ITEMS SHOWN BOLD AND DASHED SHALL BE DISCONNECTED AND REMOVED INCLUDING <br />ALL WIRING BACK TO SOURCE UNLESS OTHERWISE NOTED. <br />E ABANDON IN PLACE AND CAP ALL UNDER SLAB RACEWAYS AND REMOVE CONDUCTORS <br />BACK TO SOURCE. <br />D THESE DRAWINGS DO NOT SHOW ALL EXISTING CONDITIONS AND ONLY SHOW SYSTEMS <br />AND ITEMS THAT ARE INTENDED TO REMAIN OR BE RECONFIGURED. ALL OTHER <br />ELECTRICAL EQUIPMENT, FIXTURES, DEVICES, CONDUITS, WIRING ETC. SHALL BE <br />REMOVED FROM THE SPACE. THE ELECTRICAL CONTRACTOR SHALL FIELD VERFIY <br />EXISTING CONDITIONS AND LOCATIONS PRIOR TO BIDDING AND COMMENCEMENT ON ANY <br />WORK. <br />C ALL CUTTING, PATCHING AND ASSOCIATED COSTS SHALL BE THE RESPONSIBILITY OF THE <br />INSTALLING CONTRACTOR OR SUBCONTRACTOR. ACTUAL PATCHING AND FINISHING OF <br />SURFACES SHALL BE PERFORMED BY TRADESMAN QUALIFIED AND LICENSED FOR THE <br />SPECIFIC WORK TO BE PERFORMED. <br />B ELECTRICAL TRADES SHALL MAINTAIN WORK AREA AND SITE IN A NEAT AND ORDERLY <br />STATE. DISPOSE OF CONSTRUCTION DEBRIS ON A DAILY BASIS. <br />A ELECTRICAL TRADES SHALL COORDINATE ALL DEMOLITION WORK AND PROJECT <br />PHASING WITH ALL TRADES PRIOR TO COMENCEMENT OF ANY WORK. <br />GENERAL DEMOLITION NOTES