My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Round 1 Bowling and Amusement 12/09/2024 Paradigm Design <br />Main Place Mall Expansion Grand Rapids, MI <br />Santa Ana, California <br />Project #2309147GR <br />GYPSUM BOARD 09 2900 - 7 <br />D.Locate edge and end joints over supports, except in ceiling applications where intermediate supports <br />or gypsum board back-blocking is provided behind end joints. Do not place tapered edges against cut <br />edges or ends. Stagger vertical joints on opposite sides of partitions. Do not make joints other than <br />control joints at corners of framed openings. <br />E.Form control and expansion joints with space between edges of adjoining gypsum panels. <br />F.Cover both faces of support framing with gypsum panels in concealed spaces (above ceilings, etc.), <br />except in chases braced internally. <br />1.Unless concealed application is indicated or required for sound, fire, air, or smoke ratings, <br />coverage may be accomplished with scraps of not less than 8 sq. ft. in area. <br />2.Fit gypsum panels around ducts, pipes, and conduits. <br />3.Where partitions intersect structural members projecting below underside of floor/roof slabs <br />and decks, cut gypsum panels to fit profile formed by structural members; allow 1/4- to 3/8- <br />inch-wide joints to install sealant. <br />G.Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments. <br />Provide 1/4- to 1/2-inch-wide spaces at these locations and trim edges with edge trim where edges of <br />panels are exposed. Seal joints between edges and abutting structural surfaces with acoustical sealant. <br />H.Attachment to Steel Framing: Attach panels so leading edge or end of each panel is attached to open <br />(unsupported) edges of stud flanges first. <br />I.Install sound attenuation blankets before installing gypsum panels unless blankets are readily installed <br />after panels have been installed on one side. <br />3.3 INSTALLATION OF INTERIOR GYPSUM BOARD <br />A.Install interior gypsum board in the following locations: <br />1.Wallboard Type: As indicated on Drawings. <br />2.Type X: As indicated on Drawings. <br />3.Ceiling Type: As indicated on Drawings. <br />4.Impact-Resistant Type: As indicated on Drawings. <br />5.Moisture- and Mold-Resistant Type: As indicated on Drawings. <br />6.Glass-Mat Interior Type: As indicated on Drawings. <br />7.Cementitious Backer Type: As indicated on Drawings. <br />B.Single-Layer Application: <br />1.On ceilings, apply gypsum panels before wall/partition board application to greatest extent <br />possible and at right angles to framing unless otherwise indicated. <br />2.On partitions/walls, apply gypsum panels horizontally (perpendicular to framing) unless <br />otherwise indicated or required by fire-resistance-rated assembly, and minimize end joints.
The URL can be used to link to this page
Your browser does not support the video tag.