My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Round 1 Bowling and Amusement 12/09/2024 Paradigm Design <br />Main Place Mall Expansion Grand Rapids, MI <br />Santa Ana, California <br />Project #2309147GR <br />R.Fire-Barrier Penetrations: Maintain indicated fire rating of walls, partitions, ceilings, and floors <br />at pipe penetrations. Seal pipe penetrations with firestop materials. Refer to Division 07 <br />Section "Penetration Firestopping" for materials. <br />S.Verify final equipment locations for roughing-in. <br />T.Refer to equipment specifications in other Sections of these Specifications for roughing-in <br />requirements. <br />3.3 PIPING JOINT CONSTRUCTION <br />A.Join pipe and fittings according to the following requirements and Division 23 Sections <br />specifying piping systems. <br />B.Ream ends of pipes and tubes and remove burrs. Bevel plain ends of steel pipe. <br />C.Remove scale, slag, dirt, and debris from inside and outside of pipe and fittings before <br />assembly. <br />D.Soldered Joints: Apply ASTM B 813, water-flushable flux, unless otherwise indicated, to tube <br />end. Construct joints according to ASTM B 828 or CDA's "Copper Tube Handbook," using <br />lead-free solder alloy complying with ASTM B 32. <br />E.Brazed Joints: Construct joints according to AWS's "Brazing Handbook," "Pipe and Tube" <br />Chapter, using copper-phosphorus brazing filler metal complying with AWS A5.8. <br />F.Threaded Joints: Thread pipe with tapered pipe threads according to ASME B1.20.1. Cut <br />threads full and clean using sharp dies. Ream threaded pipe ends to remove burrs and restore <br />full ID. Join pipe fittings and valves as follows: <br />1.Apply appropriate tape or thread compound to external pipe threads unless dry seal <br />threading is specified. <br />2.Damaged Threads: Do not use pipe or pipe fittings with threads that are corroded or <br />damaged. Do not use pipe sections that have cracked or open welds. <br />G.Welded Joints: Construct joints according to AWS D10.12, using qualified processes and <br />welding operators according to Part 1 "Quality Assurance" Article. <br />H.Flanged Joints: Select appropriate gasket material, size, type, and thickness for service <br />application. Install gasket concentrically positioned. Use suitable lubricants on bolt threads. <br />I.Plastic Piping Solvent-Cement Joints: Clean and dry joining surfaces. Join pipe and fittings <br />according to the following: <br />1.Comply with ASTM F 402 for safe-handling practice of cleaners, primers, and solvent <br />cements. <br />2.CPVC Piping: Join according to ASTM D 2846/D 2846M Appendix.
The URL can be used to link to this page
Your browser does not support the video tag.