My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Round 1 Bowling and Amusement 12/09/2024 Paradigm Design <br />Main Place Mall Expansion Grand Rapids, MI <br />Santa Ana, California <br />Project #2309147GR <br />b.Piping Operating below Ambient Air Temperature: Use thermal-hanger shield <br />insert with clamp sized to match OD of insert. <br />c.Do not exceed pipe stress limits according to ASME B31.1 for power piping and <br />ASME B31.9 for building services piping. <br />2.Install MSS SP-58, Type 39, protection saddles if insulation without vapor barrier is <br />indicated. Fill interior voids with insulation that matches adjoining insulation. <br />a.Option: Thermal-hanger shield inserts may be used. Include steel weight- <br />distribution plate for pipe NPS 4 and larger if pipe is installed on rollers. <br />3.Install MSS SP-58, Type 40, protective shields on cold piping with vapor barrier. Shields <br />shall span an arc of 180 degrees. <br />a.Option: Thermal-hanger shield inserts may be used. Include steel weight- <br />distribution plate for pipe NPS 4 and larger if pipe is installed on rollers. <br />4.Shield Dimensions for Pipe: Not less than the following: <br />a.NPS 1/4 to NPS 3-1/2: 12 inches long and 0.048 inch thick. <br />b.NPS 4: 12 inches long and 0.06 inch thick. <br />c.NPS 5 and NPS 6: 18 inches long and 0.06 inch thick. <br />d.NPS 8 to NPS 14: 24 inches long and 0.075 inch thick. <br />5.Insert Material: Length at least as long as protective shield. <br />3.3 EQUIPMENT SUPPORTS <br />A.Fabricate structural-steel stands to suspend equipment from structure overhead or to support <br />equipment above floor. <br />B.Grouting: Place grout under supports for equipment and make smooth bearing surface. <br />C.Provide lateral bracing, to prevent swaying, for equipment supports. <br />3.4 METAL FABRICATIONS <br />A.Cut, drill, and fit miscellaneous metal fabrications for trapeze pipe hangers and equipment <br />supports. <br />B.Fit exposed connections together to form hairline joints. Field weld connections that cannot be <br />shop welded because of shipping size limitations. <br />C.Field Welding: Comply with AWS D1.1 procedures for shielded metal arc welding, appearance <br />and quality of welds, and methods used in correcting welding work, and with the following: <br />1.Use materials and methods that minimize distortion and develop strength and corrosion <br />resistance of base metals. <br />2.Obtain fusion without undercut or overlap.
The URL can be used to link to this page
Your browser does not support the video tag.