My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Round 1 Bowling and Amusement 12/09/2024 Paradigm Design <br />Main Place Mall Expansion Grand Rapids, MI <br />Santa Ana, California <br />Project #2309147GR <br />3.If calculations increase or decrease the air flow rates and water flow rates by more than 5 <br />percent, make equipment adjustments to achieve the calculated rates. If increase or <br />decrease is 5 percent or less, equipment adjustments are not required. <br />4.Balance each air outlet. <br />3.7 TOLERANCES <br />A.Set HVAC system's air flow rates and water flow rates within the following tolerances: <br />1.Supply, Return, and Exhaust Fans and Equipment with Fans: Plus or minus 10 percent. <br />2.Air Outlets and Inlets: Plus or minus 10 percent. <br />3.Heating-Water Flow Rate: Plus or minus 10 percent. <br />3.8 REPORTING <br />A.Initial Construction-Phase Report: Based on examination of the Contract Documents as <br />specified in "Examination" Article, prepare a report on the adequacy of design for systems' <br />balancing devices. Recommend changes and additions to systems' balancing devices to <br />facilitate proper performance measuring and balancing. Recommend changes and additions to <br />HVAC systems and general construction to allow access for performance measuring and <br />balancing devices. <br />B.Status Reports: Prepare monthly progress reports to describe completed procedures, procedures <br />in progress, and scheduled procedures. Include a list of deficiencies and problems found in <br />systems being tested and balanced. Prepare a separate report for each system and each building <br />floor for systems serving multiple floors. <br />3.9 FINAL REPORT <br />A.General: Prepare a certified written report; tabulate and divide the report into separate sections <br />for tested systems and balanced systems. <br />1.Include a certification sheet at the front of the report's binder, signed and sealed by the <br />certified testing and balancing engineer. <br />2.Include a list of instruments used for procedures, along with proof of calibration. <br />B.Final Report Contents: In addition to certified field-report data, include the following: <br />1.Pump curves. <br />2.Fan curves. <br />3.Manufacturers' test data. <br />4.Field test reports prepared by system and equipment installers. <br />5.Other information relative to equipment performance; do not include Shop Drawings and <br />product data. <br />C.General Report Data: In addition to form titles and entries, include the following data: <br />1.Title page. <br />2.Name and address of the TAB contractor.
The URL can be used to link to this page
Your browser does not support the video tag.