Laserfiche WebLink
97 <br />101 <br />105 106 <br />99 <br />107 108 <br />104 <br />TELECOMMUNICATIONS PROJECT MANAGEMENT <br />16776 BERNARDO CENTER DRIVE, UNIT 203 <br />SAN DIEGO, CA 92128 <br />15 <br />5 <br />0 <br />5 <br /> <br />S <br />A <br />N <br />D <br /> <br />C <br />A <br />N <br />Y <br />O <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br /> <br />B <br />L <br />D <br />G <br /> <br />C <br />. <br />IR <br />V <br />I <br />N <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />SHEET TITLE: <br />ISSUE STATUS <br />DATEREV.DESCRIPTION BY <br />FI <br />S <br />H <br />E <br />R <br /> <br />F <br />L <br />O <br />R <br />A <br />L <br />26 <br />7 <br />7 <br /> <br />3 <br />/ <br />4 <br /> <br />N <br />. <br /> <br />M <br />A <br />I <br />N <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />W <br />C <br />C <br />0 <br />1 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />0 02/28/2024 90% CD REVIEW jd <br />1 03/15/2024 90% CD DRM COMMENTS jd <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />03/29/2024 <br />05/17/2024 <br />06/21/2024 <br />08/01/2024 <br />09/25/2024 <br />05/07/2025 <br />06/04/2025 <br />90% CD DRM COMNTS #2 <br />100% FINAL CD <br />REVISED DIESEL TANK <br />REGULATORY HEIGHT <br />BP SUBMITTAL <br />100% CD BP PLANCHECK <br />STRUCT PLANCHECK <br />jd <br />jd <br />rl <br />jd <br />jd <br />jd <br />JD <br />D-9 <br />PROPRIETARY INFORMATION <br />THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS <br />IS PROPRIETARY TO VERIZON WIRELESS <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />. <br />D <br />. <br /> <br />1 <br />5 <br />8 <br />6 <br />1 <br />0 <br />6 <br />7 <br />Ren. 4-30-27 <br />No. C 11978 <br />LICENSED A RCHITECT <br />STATE OF CALIFORNIA <br />WILLIAM M. BOOTH <br />DETAILS <br />102 <br />98 <br />103 <br />100N.T.S. <br />SCALE:EXHAUST LOUVER VENT <br />(N) HSS 2x8 FRAME <br />8 x 8 x 16 CONCRETE BLOCK <br />SOLID GROUTED WALLS, (FINISH <br />NOT SHOWN FOR CLARITY) <br />LOUVER VENT PER PLAN <br />OP <br />E <br />N <br />I <br />N <br />G <br /> <br />P <br />E <br />R <br /> <br />P <br />L <br />A <br />N <br />2" LONG FACTORY <br />MOUNTING CLIPS <br />EVERY 18" OF <br />LOUVER PERIMETER <br />1-1/2" FACTORY ATTACHED <br />PERIMETER FLANGE <br />CAULK ENTIRE PERIMETER <br />1/2"Ø x 4-1/2" <br />EMBEDMENT STEEL <br />THREADED RODS DRILL <br />& EPOXY WITH "HILTI" <br />HIT-HY 270 ADHESIVE <br />(ICC ESR-4143). <br />**SPECIAL INSPECTION <br />REQUIRED. <br />(N) HSS 2x8 FRAME <br />#4 REBARS <br />@ 16" O.C. HORIZ. <br />& VERT. <br />FINISH FLOOR <br />FOOTING <br />1' <br />- <br />4 <br />" <br />DRAIN <br />CONCRETE BLOCK <br />ENCLOSURE WALL <br />4" <br />6"8" <br />6" <br />DRAINAGE DETAIL N.T.S. <br />SCALE:CONDUIT ATTACHMENT DETAIL <br />NFPA 704 ALERT SIGN NOT USED <br />NOT USED NOT USED NOT USED NOT USED <br />1-1/2" = 1'-0" <br />SCALE: <br />(N) 24" GALVANIZED <br />UNISTRUT <br />(N) 4" EMT CONDUIT WITH <br />CLAMPS PER PLAN <br />(E) CONCRETE PARAPET WALL <br />(2) "HILTI" 3/8"Ø STAINLESS STEEL KWIK BOLT <br />TZ2 ANCHOR WITH 2-1/2" EMBED INTO 3/8"Ø <br />HOLE DRILLED 3-1/4" DEEP. SPECIAL <br />INSPECTION REQUIRED (ICC ELC-4266) <br />CONTINUOUS 1/4" NEOPRENE STRIP <br />UNDER UNISTRUT <br />1' <br />- <br />0 <br />" <br />4" <br />6" <br />(N) 18" GALVANIZED UNISTRUT <br />(N) 4" EMT CONDUIT <br />WITH CLAMPS PER <br />PLAN <br />(E) CONCRETE PARAPET WALL <br />(2) "HILTI" 3/8"Ø STAINLESS STEEL KWIK BOLT <br />TZ2 ANCHOR WITH 2-1/2" EMBED INTO 3/8"Ø <br />HOLE DRILLED 3-1/4" DEEP. SPECIAL <br />INSPECTION REQUIRED (ICC ELC-4266) <br />CONTINUOUS 1/4" NEOPRENE STRIP <br />UNDER UNISTRUT <br />1' <br />- <br />0 <br />" <br />4" <br />CONDUIT ATTACHMENT DETAIL 1-1/2" = 1'-0" <br />SCALE: <br />CONDUIT ATTACHMENT DETAIL 1-1/2" = 1'-0" <br />SCALE: <br />(N) 18" GALVANIZED UNISTRUT <br />(N) 4" EMT CONDUIT <br />WITH CLAMPS PER <br />PLAN(E) CONCRETE PARAPET WALL <br />(2) "HILTI" 3/8"Ø STAINLESS STEEL KWIK BOLT <br />TZ2 ANCHOR WITH 2-1/2" EMBED INTO 3/8"Ø <br />HOLE DRILLED 3-1/4" DEEP. SPECIAL <br />INSPECTION REQUIRED (ICC ELC-4266) <br />CONTINUOUS 1/4" NEOPRENE STRIP <br />UNDER UNISTRUT <br />1' <br />- <br />0 <br />" <br />4" <br />(N) HOT DIP GALVANIZED <br />12" UNISTRUT BRACKET <br />BY "ATKORE" #P2514 <br />PROPOSITION 65 SIGNAGE <br />IF THE FACILITY / LOCATION HAS A STATIONARY DIESEL GENERATOR <br />·NEW SIGNAGE PER 25604 ENVIRONMENTAL EXPOSURE WARNINGS <br />·PROPOSITION 65 SIGNS IN THE FOLLOWING FORMAT, SHALL BE <br />UV-RESISTANT, PLACED ON ACCESS GATE W/ (4) STAINLESS STEEL #8 <br />HEX HEAD DRILLER. <br />·THE SIGN MUST RESEMBLE THE FOLLOWING AND BE IN 72-POINT TEXT: <br />·PLACE SIGNS WHERE EXPOSURE TO DIESEL EXHAUST MAY OCCUR <br />NOTE: GENERAL CONTRACTOR TO CONFIRM WITH THE RFE / EME STUDY WHICH WARNING <br />PLACARD TO INSTALL, WHERE TO INSTALL, AND NOT TO INSTALL THEM IF NOT REQUIRED. <br />N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE: <br />NOTE: GENERAL CONTRACTOR TO CONFIRM WITH THE RFE / EME STUDY WHICH WARNING <br />PLACARD TO INSTALL, WHERE TO INSTALL, AND NOT TO INSTALL THEM IF NOT REQUIRED. <br />3" HELVETICA <br />LETTERING(4) STAINLESS <br />STEEL #8 HEX <br />HEAD DRILLER <br />IF THE FACILITY / LOCATION HAS A STATIONARY DIESEL GENERATOR <br />·NEW NFPA 704 ALERT SIGN (PER NFPA 704 SECTION 4.2.3.3. (2) (INDIVIDUAL <br />METHOD) AND CFC 5003.5 DIESEL NO. 1 TO BE MOUNTED ON THE DIESEL <br />GENERATOR AND OR THE ENTRANCE TO THE GENERATOR AREA.