My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2677 3%4 N Main Unit#WCC01 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2677 N Main St
>
2677 3%4 N Main Unit#WCC01 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:10 AM
Creation date
2/13/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
101123169
101123170
Full Address
2677 N Main St
2677 3/4 N Main Unit# WCC01
Street Number
2677
Partial
3/4
Street Direction
N
Street Name
Main
Unit Number
WCC01
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project No. VP-6214-01 <br />Verizon Wireless — Fisher Floral <br />proposed project would not have an adverse impact on adjacent proper <br />recommendations contained in this report and applicable standards are <br />design and construction, and our recommended quality control measures <br />during construction. <br />Foundation Design Recommendations <br />Enclosure Wall <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />Approved <br />FOR PERMIT ISSUANCE <br />s provided our <br />in <br />Enclosure walls may be supported by conventional continuous footing 18 inches wide <br />and 18-inches deep bearing on competent materials or newly compacted fill, and may be <br />designed for an allowable bearing value of 1,500 psf. <br />Based on test results, the underlying surface soils are non -expansive; therefore, special <br />measures will not be required for expansion potential. The subgrade for slab on grade <br />should be kept moist (optimum moisture) at top 12 inches and be incorporated with <br />reinforcement of #3 bars 12 inches center to center each way. The slab thickness should <br />be 5 inches minimum and shall be placed over approved subgrade. <br />Other aspects of the design, including minimum reinforcement, footing embedment, <br />additional posts and beams, and the need for interior footings, are to be determined by the <br />project structural engineer. <br />Equipment Cabinets & Generator Pads <br />Based on test results, the underlying surface soils are non -expansive, therefore, special <br />measures will not be required for expansion potential. However, the top 12 inches of soil <br />may be excavated and re -compacted back to at least 90% of ASTM D 1557 laboratory <br />Standard. The subgrade for slab on grade should be kept moist (optimum moisture) at <br />top 12 inches and be incorporated with reinforcement of #3 bars 18 inches center to <br />center each way. The slab thickness should be 4 inches minimum and shall be placed <br />over approved subgrade. It is highly recommended to remove tree roots during site <br />preparation. <br />9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.