Laserfiche WebLink
(E) CURB1 <br />E) DRIVEWAY APPROACHED2 <br />(E) DRIVEWAY3 <br />(E) SIDEWALK4 <br />(E) CONCRETE WALKWAY5 <br />(E) CONCRETE SLAB6 <br />(E) FRONT YARD <br />7 <br />(E) REAR YARD <br />8 <br />(E) PLANTER <br />9 <br />(E) 6 Ft. Ht. BLOCK WALL FENCE <br />11 <br />12 <br />(E) 3 Ft. Ht. WOOD FENCE <br />13 <br />(E) 6 Ft. Ht. WOOD GATE <br />14 <br />(E) 6 Ft. Ht. METAL GATE <br />15 <br />(E) 3 Ft. Ht. WOOD GATE <br />(E) 3 Ft. Ht. METAL GATE <br />17 <br />(E) ELECTRICAL METER 100 AMPS <br />18 <br />(E) WATER METER <br />19 <br />(E) GAS METER 1"Ø <br />20 <br />(E) A/C CONDENSER UNIT: AC PRO MODEL # 4AC17L36P <br />21 <br />(E) TREE <br />10 <br />22 <br />23 <br />(E) CONCRETE PAVERS <br />24 <br />25 <br />(E) CONCRETE LANDING/STEPS <br />(E) NEW CONCRETE WALKWAY <br />(E) CONCRETE SLAB <br />(E) NEW CONCRETE LANDING/STEPS <br />26 <br />29 <br />30 <br />31 <br />32 <br />33 <br />34 <br />35 <br />(E) CRAWLSPACE ACCESS <br />(E) A/C CONDENSER UNIT LOCATION <br />(E) NEW CRAWLSPACE ACCESS <br />(E) CONCRETE WASHOUT AREA <br />(LOCATION MAY VARY) <br />(SEE SHEET GB-3 FOR SPECS) <br />(E) GRAVEL BAGS OR FIBER ROLLS <br />(SEE SHEET GB-3 FOR SPECS) <br />(E) 3 Ft. Ht. BLOCK WALL FENCE <br />(E) 6 Ft. Ht. WOOD FENCE <br />(E) WATER HEATER: A.O. Smith #G6-PVT5050NV <br />16 <br />27 (E) GROUND <br />28 E) EXISTING FIRE PLACE TO BE <br />DEMOLISH <br />L= <br />1 <br />0 <br />0 <br />' <br />PL= <br />1 <br />0 <br />0 <br />' <br />P <br />L=60'P <br />L=60'P <br />EXISTING 1-STORY S.F.R. TO <br />BE REMODELED <br />1,111 Sq. Ft. <br />FIRE SPRINKLER SYSTEM: NO <br />EXISTING CAR <br />GARAGE <br />413.30 Sq. Ft. <br />STAYING AS IT IS <br />1 SCALE: 1/8" = 1'-0" <br />N <br />RAMONA DR. <br />Existing Site Plan <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2 <br />4 4 <br />11 <br />27 <br />11 <br />11 <br />3 <br />5 <br />17 <br />13 13 <br />13 13 <br />5 <br />30 <br />' <br />- <br />5 <br />" <br />16'-0" <br />20 <br />' <br />- <br />9 <br />" <br />5'-6" <br />6 <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />12 <br />24 <br />21 <br />G.M. <br />23 <br />22 <br />27 <br />27 <br />27 <br />44 <br />' <br />- <br />1 <br />1 <br />" <br />17 <br />W H <br />25 <br />4'-10" <br />28 <br />NOTE: EXISTING ROOF PLAN STAYING AS IT IS <br />2' <br />- <br />4 <br />" <br />2'-4" <br />3'-4" <br />2' <br />- <br />4 <br />" <br />2'-4" <br />2' <br />- <br />4 <br />" <br />2'-3" <br />2' <br />- <br />4 <br />" <br />FIRE BLOCKING MUST BE PROVIDED IN <br />ACCORDANCE WITH CRC SECTION R302.11 AT <br />THE FOLLOWING LOCATIONS: <br />A. IN CONCEALED SPACES OF STUD WALLS <br />AND PARTITIONS, INCLUDING FUMED SPACES, <br />AT THE CEILING AND FLOOR LEVELS. <br />B. IN CONCEALED SPACES OF STUD WALLS <br />AND PARTITIONS, INCLUDING FURRED SPACES, <br />AT 10-FOOT INTERVALS ALONG THE LENGTH OF <br />THE WALL. <br />C. AT ALL INTERCONNECTIONS BETWEEN <br />CONCEALED VERTICAL AND HORIZONTAL SPACES <br />SUCH AS OCCUR AT SOFFITS, DROP CEILINGS <br />AND COVE CEILINGS. <br />D. IN OPENINGS AROUND VENTS, PIPES, <br />DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR <br />OPENINGS WHICH AFFORD A PASSAGE FOR FIRE <br />AT CEILING AND FLOOR LEVELS, WITH <br />MATERIALS TESTED FOR THE FORM AND <br />MANNER THEY ARE INTENDED. <br />1 SCALE: 1/8" = 1'-0" <br />N <br />RAMONA DR. <br />Existing Site Plan <br />NOTE: EXISTING ROOF PLAN STAYING AS IT IS <br />L= <br />1 <br />0 <br />0 <br />' <br />PL= <br />1 <br />0 <br />0 <br />' <br />P <br />L=60'P <br />L=60'P <br />EXISTING 1-STORY S.F.R. TO <br />BE REMODELED <br />1,111 Sq. Ft. <br />FIRE SPRINKLER SYSTEM: NO <br />EXISTING CAR <br />GARAGE <br />413.30 Sq. Ft. <br />STAYING AS IT IS <br />1 SCALE: 1/8" = 1'-0" <br />N <br />RAMONA DR. <br />Proposed Site Plan <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />2 <br />4 4 <br />11 <br />27 <br />11 <br />11 <br />3 <br />5 <br />17 <br />13 13 <br />13 13 <br />5 <br />30 <br />' <br />- <br />5 <br />" <br />16'-0" <br />20 <br />' <br />- <br />9 <br />" <br />5'-6" <br />6 <br />2% <br /> <br />M <br />I <br />N <br />. <br />SL <br />O <br />P <br />E <br />12 <br />24 <br />21 <br />G.M. <br />23 <br />22 <br />27 <br />27 <br />27 <br />44 <br />' <br />- <br />1 <br />1 <br />" <br />17 <br />W H <br />25 <br />4'-10" <br />28 <br />NOTE: SAME As Existing Site Plan <br />2' <br />- <br />4 <br />" <br />2'-4" <br />3'-4" <br />2' <br />- <br />4 <br />" <br />2'-4" <br />2' <br />- <br />4 <br />" <br />2'-3" <br />2' <br />- <br />4 <br />" <br />FIRE BLOCKING MUST BE PROVIDED IN <br />ACCORDANCE WITH CRC SECTION R302.11 AT <br />THE FOLLOWING LOCATIONS: <br />A. IN CONCEALED SPACES OF STUD WALLS <br />AND PARTITIONS, INCLUDING FUMED SPACES, <br />AT THE CEILING AND FLOOR LEVELS. <br />B. IN CONCEALED SPACES OF STUD WALLS <br />AND PARTITIONS, INCLUDING FURRED SPACES, <br />AT 10-FOOT INTERVALS ALONG THE LENGTH OF <br />THE WALL. <br />C. AT ALL INTERCONNECTIONS BETWEEN <br />CONCEALED VERTICAL AND HORIZONTAL SPACES <br />SUCH AS OCCUR AT SOFFITS, DROP CEILINGS <br />AND COVE CEILINGS. <br />D. IN OPENINGS AROUND VENTS, PIPES, <br />DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR <br />OPENINGS WHICH AFFORD A PASSAGE FOR FIRE <br />AT CEILING AND FLOOR LEVELS, WITH <br />MATERIALS TESTED FOR THE FORM AND <br />MANNER THEY ARE INTENDED. <br />ISSUE AND REVISIONS <br />CLIENT <br />PROJECT DESIGNER: <br />- <br />SHEET NUMBER <br />JURISDICTION APPROVAL <br />120 NEWPORT CENTER DR. <br />NEWPORT BEACH, CA 92660 <br />infojeanprescott@gmail.com <br />www.jean-prescott.com <br />714.588.0029 <br />Copyright-2023 <br />Expressly reserves its common law copyright and other <br />property rights in these plans. <br />These plans are not to be reproduced, changed or <br />copied in any form or manner whatsoever, nor are they <br />to be assigned to any third party, without first obtaining <br />the written permission and consent of Jeannice Carrillo <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />: <br />26 <br />2 <br />2 <br /> <br />R <br />A <br />M <br />O <br />N <br />A <br /> <br />D <br />R <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />JEANNICE CARRILLO <br />DON WALKER <br />EXISTING <br />AND PROPOSED <br />SITE PLAN <br />A1.0