Laserfiche WebLink
1 SCALE: 3/8" = 1'-0" <br />(E) 2-CAR GARAGE <br />(E) KITCHEN TO BE <br />REMODEL <br />(E) DINING ROOM <br />CLG. HT. = 8'-0" <br />(E) LIVING SPACE <br />CLG. HT. = 8'-0" <br />(E) FURNACE <br />(E) HALLWAY <br />(E <br />) <br />B <br />A <br />T <br />H <br /> <br />1 <br />CL <br />G <br />. <br /> <br />H <br />T <br />. <br /> <br />= <br /> <br />8 <br />' <br />- <br />0 <br />" <br />(E <br />) <br />B <br />A <br />T <br />H <br /> <br />2 <br />CL <br />G <br />. <br /> <br />H <br />T <br />. <br /> <br />= <br /> <br />8 <br />' <br />- <br />0 <br />" <br />(E)CLOSET <br />(E <br />) <br />C <br />L <br />O <br />S <br />E <br />T <br />(E)CLOSET <br />(E <br />) <br />C <br />L <br />O <br />S <br />E <br />T <br />(E) BEDROOM 1 <br />CLG. HT. = 8'-0" <br />(E) BEDROOM 2 <br />CLG. HT. = 8'-0" <br />UP <br />1 <br />(E <br />) <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />D <br />O <br />O <br />R <br />10'-3"1'-11"1'-10"9'-6"12'-7" <br />38'-6" <br />10 <br />' <br />- <br />8 <br />" <br />2' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />3 <br />" <br />12'-3"3'-11"4'-10"1'-10"3'-6" <br />9' <br />- <br />2 <br />" <br />19 <br />' <br />- <br />1 <br />0 <br />" <br />20'-0" <br />17 <br />' <br />- <br />8 <br />" <br />24 <br />' <br />- <br />8 <br />" <br />25'-2" <br />18 <br />' <br />- <br />2 <br />" <br />18 <br />' <br />- <br />7 <br />" <br />30 <br />' <br />- <br />3 <br />" <br />20'-11" <br />26 <br />' <br />- <br />1 <br />1 <br />" <br />(E <br />) <br />C <br />L <br />O <br />S <br />E <br />T <br />A <br />B <br />C <br />BB <br />DD <br />D <br />D <br />B <br />E <br />1 <br />2 63 <br />4 <br />EXISTING FLOOR PLAN <br />(E) BEDROOM 3 <br />CLG. HT. = 8'-0" <br />A <br />B <br />A-5 <br />7 <br />7 <br />(N) FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH CRC SECTION <br />R302.11 AT THE FOLLOWING LOCATIONS: <br />A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING <br />FUMED SPACES, AT THE CEILING AND FLOOR LEVELS. <br />B. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING <br />FURRED SPACES, AT 10-FOOT INTERVALS ALONG THE LENGTH OF THE WALL. <br />C. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND <br />HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND <br />COVE CEILINGS. <br />D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES <br />AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING <br />AND FLOOR LEVELS, WITH MATERIALS TESTED FOR THE FORM AND <br />MANNER THEY ARE INTENDED. <br />5 <br />8 <br />9 <br />A-5 <br />SD <br />SD CMCOMBO SD CMCOMBO <br />SD <br />SD <br />SD CMCOMBO <br />SD <br />SD <br />EF40 CFM <br />EF50 CFM <br />2'-9" <br />5'-8" <br />AC PRO MODEL # <br />4AC17L36P <br />A.O. Smith <br />#G6-PVT5050NV <br />AC PRO MODEL # <br />80G1UH060AE12X <br />(N)ELECTRICAL <br />FIREPLACE <br />FRONT DOOR TO BE <br />REPLACED(CONTRACTOR <br />VERIFIED IN FIELD) <br />(R) <br />STATUS <br />SOLID DOOR <br />2'-7" x 6'-8" <br />HOLLOW CORE1-11" x 6'-8" <br />35 3/4" x 80" <br />HOLLOW CORE <br />2-5" x 6'-8"HOLLOW CORE <br />-- -- <br />-- -- <br />-- -- <br />-- -- <br />0.30 0.23 <br />DOOR SCHEDULE <br />WINDOW SCHEDULE <br />NOTE: ALL ROUGH OPENINGS SHOULD BE CHECKED PRIOR TO ORDERING, OR <br />VERIFY WITH MANUFACTURER <br />(E)=EXISTING , (R) = EXISTING TO BE REPLACED (ETR) EXISTING TO BE REMAIN <br />A <br />B <br />C <br />D <br />7 <br />2 <br />3 <br />35 1/2" x 24 1/2" <br />72 1/2" x 36 1/2" <br />35 1/2" x48 1/2" <br />SLIDING <br />SLIDING5 <br />6 <br />35 1/2" x 35" <br />6-0" x 6'-8"0.30 0.23ESLIDING, TEMP. GLASS <br />4 60" x 36 3/4" <br />SYM SIZE TYPE U-FACTOR SHGC QTY <br />STATUS SYM SIZE TYPE U-FACTOR SHGC QTY <br />SLIDING <br />1 48" x 49" <br />(R) <br />(R) <br />(R) <br />(R) <br />(R) <br />(R) <br />SLIDING <br />8 72" x 25"(ETR) <br />SLIDING <br />SLIDING <br />SLIDING TEMPRED FROZED <br />SLIDING <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />SLIDING 0.30 0.23 <br />9 60" x 36 1/4"(R) <br />35 1/2" x 24 1/2" <br />A(N)1 HOUR FIRE RATED WALL <br />FOUNDATION <br />WALL STUDS <br />INTERIOR F.F.EXTERIOR F.F.2X BOTTOM PLATE <br />SHEATING <br />SELF FURRING MESH <br />2 LAYERS OF WATER RESISTANT <br />BARRIER 30LB. FELT, MIN. <br />RAFTER <br />JOISTFASCIA <br />SOFFIT BOARD <br />ROOF COVERING <br />1/2" CDX <br />15# ROOFING FELT <br />(N) ONE HOUR FIRE RATED EAVE <br />(P) JAMES HARDY BOARD58" TYPE X GYPSUM BOARD <br />James Hardie <br />Magnolia Home Hardie Panel <br />HZ10 48 in. x 120 in. Fiber <br />Cement Smooth in Birch Tree <br />Pane <br />(P) JAMES HARDY BOARD <br />James Hardie <br />Magnolia Home Hardie Panel <br />HZ10 48 in. x 120 in. Fiber <br />Cement Smooth in Birch Tree <br />Pane <br />FIRE BLOCK <br />4% VENTILATION AND 8% LIGHT REQUIREMENT: <br />(E)BEDROOM1 <br />4%ROOM VENTILATION x 129.40 Sq.Ft.= 5.17 Sq.Ft. <br />8% ROOM LIGHT x 129.40 Sq.Ft. = 10.35 Sq.Ft. <br />(E)WINDOW MEASUREMENT 5'-9"x3'-0"=17.7 Sq.Ft. <br />TOTAL = 31.017 .....OK <br />(E)BEDROOM 2 <br />4%ROOM VENTILATION x 109.20 Sq.Ft.= 4.36 Sq.Ft. <br />8% ROOM LIGHT x 109.20 Sq.Ft. = 8.73 Sq.Ft. <br />(E) WINDOW MEASUREMENT 4'-9"x3'-0"=14.7 Sq.Ft. <br />(E)WINDOW MEASUREMENT 2'-7"x3'-0"=8.1 Sq. Ft. <br />TOTAL = 31.017 .....OK <br />(E)BEDROOM 3 <br />4%ROOM VENTILATION x 92.93 Sq.Ft.= 3.71 Sq.Ft. <br />8% ROOM LIGHT x 139.66 Sq.Ft. = 7.43 Sq.Ft. <br />(E) WINDOW MEASUREMENT 4'-9"x3'-0"= 14.7 Sq.Ft... OK <br />(E)LIVING SPACE <br />4%ROOM VENTILATION x 228.27 Sq.Ft.= 9.13 Sq.Ft. <br />8% ROOM LIGHT x 228.27 Sq.Ft. = 18.26 Sq.Ft. <br />(E) DOOR MEASUREMENT 5'-8"x6'-8"= 39.44 Sq.Ft. <br />(E)WINDOW MEASUREMENT 3'-11"x3'-0"=9.33 <br />x 2 PIECES = 18.66 Sq. Ft....OK <br />WOOD SHEATHING <br />WATER-RESISTIVE BARRIER <br />(BUILDING PAPER) <br />METAL LATH OR WELDED WIRE LATH <br />SCRATCH COAT <br />BROWN COAT <br />FINISH COAT <br />WEEP SCREED <br />TRADITIONAL THREE-COAT STUCCO FINISH <br />WALL CONSTRUCTION/STUCCO DETAIL <br />EGRESS WINDOW <br />EMERGENCY EGRESS WINDOW ELEVATION <br />(INTERIOR ELEVATION NOT TO SCALE) <br />INTERIOR FINISH FLOOR <br />WINDOW <br />FRAMEOPENED <br />AREA <br />MINIMUM OPENING REQUIREMENTS <br />24” Minimum Clear Height <br />20” Minimum Clear Width <br />5.0 S.F. minimum opened area (1st. floor) <br />5.7 S.F. minimum opened area (2nd. floor) <br />44 <br />" <br /> <br />M <br />A <br />X <br />20" MIN. CLEAR <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />E <br />A <br />R <br />1. OPENING PROTECTION: OPENINGS FROM A PRIVATE <br />GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING <br />PURPOSES SHALL NOT BE PERMITTED. <br />1-HOUR FIRE RATED WALL <br />1 2x WOOD STUD PER STR'L <br />(WITH INSULATION WHERE OCCURS) <br />5/8" THK. TYPE "X" GYPSUM BOARD. <br />(SINGLE LAYER)2 <br />1 <br />2 <br />2 <br />INTERIORGARAGE <br />GARAGE <br />HABITABLE ROOM <br />2 <br />3 <br />PLYWOOD SHEATHING PER STR'L PLANS3 <br />1-HOUR FIRE RATED CEILING <br />4 2x WOOD JOINTS PER STR'L <br />(WITH INSULATION WHERE OCCURS) <br />4 <br />2. DOORS BETWEEN GARAGE AND THE DWELLING UNIT <br />SHALL HAVE A MINIMUM FIRE PROTECTION RATING OF 20 <br />MINUTES AND SELF-CLOSING AND SELF-LATCHING DEVICES, <br />OR SOLID WOOD OR SOLID OR HONEYCOMB CORE STEEL NOT <br />LESS THAN 1-3/8 INCHES THICK. (R302.5. 1) <br />3. THE GARAGE SHALL BE SEPARATED FROM THE DWELJ.ING <br />AND ITS ATTIC AREA IN ACCORDANCE WITH TABLE <br />R302.6{R302.6). <br />NOTES: <br />KEY NOTES: <br />4. DUCT PENETRATION: DUCTS IN THE GARAGE AND DUCTS <br />PENETRATING THE WALLS OR CEILINGS SEPARATING THE <br />DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A <br />MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER <br />APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO <br />THE GARAGE. [R302.5.2) <br />5. OTHER PENETRATIONS OF GARAGE/DWELLING CEILINGS <br />AND WALLS SHALL BE PROTECTED AS REQUIRED BY SECTION <br />R302.11. ITEM 4 {R302.5.3). <br />ELEVATION VIEW <br />ELEVATION VIEW <br />X FIRE RESISTANT CONSTRUCTION DETAIL <br />ISSUE AND REVISIONS <br />CLIENT <br />PROJECT DESIGNER: <br />- <br />SHEET NUMBER <br />JURISDICTION APPROVAL <br />120 NEWPORT CENTER DR. <br />NEWPORT BEACH, CA 92660 <br />infojeanprescott@gmail.com <br />www.jean-prescott.com <br />714.588.0029 <br />Copyright-2023 <br />Expressly reserves its common law copyright and other <br />property rights in these plans. <br />These plans are not to be reproduced, changed or <br />copied in any form or manner whatsoever, nor are they <br />to be assigned to any third party, without first obtaining <br />the written permission and consent of Jeannice Carrillo <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />: <br />26 <br />2 <br />2 <br /> <br />R <br />A <br />M <br />O <br />N <br />A <br /> <br />D <br />R <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />JEANNICE CARRILLO <br />DON WALKER <br />EXISTING <br />FLOOR PLAN <br />A2-0 <br />EXISTING 2x STUD WALL TO REMAIN <br />NEW WALL CONSTRUCTION WITH 2x4 STUDS D.F. No.2 @ 16"O.C. <br /> NOTES: <br /> a. USE 2x6 STUDS D.F. No.2 @ 16" O.C. FOR PLUMBING WALLS <br /> b. USE 2x4 STUDS D.F No.2 @ 16" O.C. FOR NON BEARING WALLS