<br />GFCI
<br />GFCI
<br />CO/SD
<br />GFCI
<br />GFCI
<br />GFCI
<br />GFCI
<br />R
<br />R
<br />R
<br />R
<br />3
<br />GFCI
<br />GFCI
<br />GFCI
<br />VS
<br />R
<br />R
<br />3
<br />EP
<br />BEDROOM 2
<br />BEDROOM 3
<br />BEDROOM 4
<br />MASTER BEDROOM
<br />LIVING
<br />HALL
<br />DINING
<br />KITCHEN
<br />PORCH
<br />BATH
<br />LAUNDRY
<br />LAUNDRY
<br />CLOSET
<br />N
<br />E1
<br />SHEET:
<br />SCALE:
<br />DATE:
<br />11/25/2024
<br />Revision Table
<br />Number
<br />Date
<br />Revised By
<br />Description
<br />1
<br />10/27/2023
<br />JO
<br />PLANNING
<br />2
<br />01/31/2024
<br />JO
<br />PLANNING
<br />3
<br />03/08/2024
<br />JO
<br />BP
<br />4
<br />04/02/2024
<br />JO
<br />PCC
<br />5
<br />11/25/2024
<br />JO
<br />PCC
<br />COMPA'S DESIGN SERVICES
<br />949 N. IROQUOIS AVE.
<br />ANAHEIM, CA 92801
<br />JUAN ORELLANA _____________
<br />ELECTRICAL NOTES
<br />1.) VERIFY CONNECTION POINTS FOR POWER TELEPHONE, GAS, SEWER AND CATV SYSTEMS
<br />PRIOR TO CONSTRUCTION APPROXIMATE ONLY LOCATIONS INDICATED.
<br />2.) NOTE: OPENINGS AROUND ELECTRICAL PENETRATIONS, FLOORS, CEILINGS, SHALL BE FIRE
<br />STOPPED USING APPROVED METHONDS TO MAINTAIN THE FIRE RATING.
<br />3.) NOTE: SMOKE DETECTORS SHALL BE LOCATED AT VAULTED CEILINGS
<br />4.) PROVIDE AT LEAST TWO 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS TO SERVE TO
<br />KITCHEN, BREAKFAST ROOM, AND DINNING ROOM. SUNCH CIRCUITS SHALL HAVE NO OTHER
<br />OUTLETS.
<br />5.) PROVIDE AT LEAST ONE 20-AMPERE BRANCH CIRCUIT TO SERVE LAUNDRY APPLIANCES
<br />SUNCH CIRCUIT(S) SHALL HAVE NO OTHER OUTLETS.
<br />6.) ALL ALUMINUM CONDUCTORS ARE PERMITTED ONLY IF SIZE 1/0 OR LARGE, AND ONLY TO
<br />FEED MAIN OR SUB-PANELS, ALL OTHER CURRENT CARRYING CONDUCTORS SHALL BE
<br />COPPER"
<br />7.) "BONDS GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING."
<br />8.) SMOKE ALARMS SHALL BE 120-VOLT WITH BATTERY BACK-UP.
<br />9.) PROVIDE 120-SMOKE ALARMS. LOCATED NO LESS THAN 3'-0" FROM AIR REGISTER. IN
<br />DWELLING UNITS, A SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A
<br />POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARTATE
<br />SLEEPING AREA. WHEN THE DWELLING UNIT HAS MORE THAN ONE STORY AND IN DWELLING
<br />WITH BASEMENT, A SMOKE ALARM SHALL BE INSTALLED ON EACH STORY AND IN THE
<br />BASEMENT. IN DWELLING UNIT WHERE A STORY BASEMENT IS SPLIT INTO TOW OR MORE
<br />LEVELS, THE SMOKE ALARM SHALL BE INSTALLED ON THE UPPER LEVEL, EXCEPTTHAT WHEN
<br />THE LOWER LEVEL CONTAINS A SLEEPING AREA, A SMOKE ALARM SHALL BE INSTALLED ON
<br />EACH LEVEL. WHEN SLEEPING ROOMS ARE ON AN UPPER LEVLE, THE SMOKE ALARMS SHALL
<br />BE PLACED AT THE CEILING OF THE UPPER LEVLE IN CLOSE PROXIMITY TO THE STAIRWAY. IN
<br />DWELLING UNITS WHERE THE CEILING HEIGHT OF A ROOM OPEN TO THE HALLWAY SERIVE THE
<br />BEDROOMS EXCEED THAT OF THE HALLWAY BY 24 INCHES OR MORE, SMOKE ALARMS SHALL
<br />BE INSTALLE DIN THE HALLWAY AND IN THE ADJACENT ROOM. SMOKE ALARMS SHALL SOUND
<br />AND ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING UNIT IN WHICH ARE LOCATED.
<br />10.) PERMANENTLY WIRED SMOKE DETECTOR, 110V POWERED W/BATTERY BACK-UP INSIDE EACH
<br />BEDROOM. (CEILING MOUNTED, U.N.O. ) NOTE: DETECTOR SHALL SOUND AN ALARM AUDIBLE
<br />IN ALL SLEEPING AREAS OF THE UNIT.
<br />11.) LIGHTING IN KITCHEN AND RESTROOM SHALL BE HIGH EFFICACY.
<br />12.) SPECIFY ARC-FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL CIRCUITS SUPPLYING 125-
<br />VOLT, SINGLE PHASE, 20 AMPERE RECEPTACLES IN BEDROOMS. RECEPTACLES LOCATED IN
<br />BATHROOMS, GARAGES, OUTDOORS, KITCHENS (WHERE RECPTACLES SERVE COUNTER TOP
<br />SURFACES), SINKS (WITHIN 6FT OF THE EDGE OF THE SINK), BATHTUB AND SHOWER STALLS
<br />(WITHIN 6FT OF THE EDGE OF THE BATHTUB OR SHOWER STALL) AND LAUNDRY AREAS SHALL
<br />HAVE GROUND FAULT CIRCUIT-INTURRUPTER (GFCI) PROTECTION.
<br />13.ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVCES (SUCH AS LIGHTS & SWITCHES)
<br />INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
<br />PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
<br />HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS & AREAS SHALL BE PROVIDED WITH ARC-
<br />FAULT CIRCUIT-INTERRUPTERS (AFCI) PROTECTION.
<br />14.) ALL WALL SPACES, 2 FEET OR MORE IN WIDTH, SHALL HAVE RECEPTACLES INSTALLED SUCH
<br />THAT NO POINT MEASURED HORIZONTALLY IS MORE THAN 6 FEET FROM A RECEPTACLE (12
<br />FEET MAXIMUM SPACING.)
<br />15.) COUNTERTOPS IN KITCHENS, PANTRIES, BRAKFAST ROOMS, DINDING ROOMS AND SIMILAR
<br />AREAS SPACES 12 INCHES OF WIDER SHALL HAVE RECEPTACLES INSTALLED SUCH THAT NO
<br />POINT ALONG THE WALL IS MORE THAN 2 FEET FROM A RECEPTACLE.
<br />16.) AT LEASE ONE RECEPTALCE AT GRADE LEVEL SHALL BE INSTALLED IN BOTH THE FRONT
<br />AND BACK OF EACH DWELLING UNIT.
<br />17.) AT LEAST ONE RECEPTACLE, IN ADDITION TO THOSE FOR SPECIFIC EQUIPMENT, SHALL BE
<br />INSTALLED IN THE FOLLOWING LOCATIONS.
<br /> A. IN EACH ATTACHED AND DETACHED GARAGE WITH ELECTRIC POWER. THE
<br /> BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE SHALL NOT SUPPLY OUTLETS
<br /> OUTSIDE OF THE GARAGE. AT LEAST ONE RECEPTACLE OUTLET SHALL BE
<br /> INSTALLED FOR EACH CAR SPACE.
<br /> B. IN EACH ACCESSORY BUILDING WITH ELECTRIC POWER
<br /> C. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT
<br />18.) ALL NONLOCKING-TYPE 125-VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED
<br />TAMPER-RESISTANT
<br /> RECEPTACLES.
<br />19.) IN CLOSETS, LUMINAIRES SHALL BE
<br /> (A) SURFACE-MOUNTED OR RECESSED INCANDESCENT OR LED WITH COMPLETELY
<br />ENCLOSED LIGHT SOURCES,
<br /> (B)SURFACE MOUNTED OR RECESSED FLUORESCENT LUMINAIRES,
<br /> (C) SURFACE MOUNTED FLUORESCENT OR LED LUMNARIES IDENTIFIED AS SUITABLE FOR
<br /> INSTALLATION WITHIN STORAGE AREAS. MINIMUM CLEARANCES BETWEEN
<br /> LUMINARIAS AND THE NEAREST POINT OF STORAGE SPACE SHALL BE AS FLOLLOWS.
<br /> A. 12" FOR SURFACE MOUNTED INCANDESCENT OR LED LUMINARIES WITH COMPLETELY
<br />ENCLOSED LIGHT
<br /> INSTALLED ON THE WALL ABOVE THE DOOR OR ON THE CEILING.
<br /> B. 6" FOR SURFACE MOUNTED FLUORESCENT LUMINARIAS INSTALLED ON THE WALL
<br /> ABOVE THE DOOR OR ON THE CEILING.
<br /> C. 6" FOR RECESSED INCANDESCENT OR LED LUMINARIES WITH A COMPLETELY
<br /> ENCLOSED LIGHT SOURCE INSTALLED IN THE WALL OR CEILING.
<br /> D. 6" FOR RECESSED FLUORESCENT LUMINARIES INSTALLED IN THE WALL OR CEILING.
<br /> E. SURFACE-MOUNTED FLUORESCENT OF LED LUMINARIES SHALL BE PERMITTED
<br /> TO BE INSTALLED WITHIN CLOSET STORAGE SPACE WHERE IDENTIFIED FOR THIS USE.
<br />20.) ALL INSTALLED LUMINARIES SHALL BE HIGH- EFFICACY. HIGH EFFICACY LIGHT SOURCES
<br />INCLUDE
<br /> A. PIN-BASED LINEAR OR COMPACT FLUORESCENT LAMPS (CFL) SOURCES USING ELECTRONIC
<br />BALLASTS.
<br /> B. PULSE-START METAL HALIDE LAMPS.
<br /> C. HIGH PRESSURE SODIUM LAMPS.
<br /> D. GU-24 SOCKETS CONTAINING CFL OR LED LIGHT SOURCES.
<br />21.) LUMINARIES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS
<br /> A. BE LISTED FOR ZERO CLEARANCE INSULATION CONTACT (IC).
<br /> B. HAVE A LABEL THAT CERTIFIES THE LUMINARIES IS AIRTIGHT WITH AIR LEAKAGE
<br /> LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM
<br /> E283.
<br /> C. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARIES HOUSING AND
<br /> CEILING AND SHALL HAVE ALL
<br /> AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A
<br />GASKET OR CAULK.
<br /> D. FOR LUMINARIES WITH HARDWIRED BALLASTS OR DRIVERS, ALLOW BALLAST OR DRIVER
<br />MAINTENANCE AND
<br /> REPLACEMENT TO BE READILY ACCESSIBLE TO BUILDING OCCUPANTS FROM BELOW THE
<br />CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN THE CEILING.
<br /> E. SHALL NOT CONTAIN SCREW BASE SOCKETS.
<br /> F. SHALL CONTAIN LIGHT SOURCES THAT ARE MARKED "J8A-2016-E".
<br />22.) EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. LIGHTING
<br />INTEGRAL TO AN
<br /> EXHAUST FAN MAY BE ON THE SAME SWITCH AS THE FAN PROVIDED THE LIGHTING CAN BE
<br />SWITCHED OFF
<br /> WHILE ALLOWING THE FAN TO CONTINUE TO OPERATE FOR AN EXTENDED PERIOD OF TIME.
<br />23.) IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINARIES
<br />IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR.
<br />24.) ALL JA8 COMPLAINT LIGHT SOURCES, EXCEPT THOSE IN CLOSETS LESS THAN 70 SQUARE
<br />FEET AND THOSE IN
<br /> HALLWAYS, SHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. 150(K)2K & TABLE
<br />150.0-A CEC) JA8
<br /> COMPLIANT LIGHT SOURCES INCLUDE LIGHT SOURCES IN CEILING RECESSED DOWNLIGHT
<br />LUMINARIES AND
<br /> GU-24 SOCKETS CONTAINING LED LIGHT SOURCES
<br />25.) ALL RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY MOUNTED TO THE RESIDENCE OR
<br />OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH-EFFICACY AND MEET THE FOLLOWING
<br />REQUIREMENTS:
<br />A. LIGHTS SHALL COMPLY WITH ONE OF THE TWO OPTIONS BELOW:
<br /> I. CONTROLLED BY A PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON
<br />SHALL NOT BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION
<br />SENSOR WITHIN 6 HOURS.
<br /> II. CONTROLLED BY (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL OR (2)
<br />ASTRONOMICAL TIME CLOCK OR (3) ENERGY MANAGEMENT CONTROL SYSTEM MEETING THE
<br />REQUIREMENTS OF 150(K)3A.
<br />B. LIGHTS SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE
<br />TO ON THE AUTOMATIC ACTIONS OF ITEM I OR ITEM II CHOSEN ABOVE.
<br />26). ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS
<br />OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING
<br />ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
<br />HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY
<br />OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6). AT KITCHEN COUNTER, INDICATE
<br />COMBINATION AFCI/GFCI RECEPTACLES
<br />27). SMOKE ALARMS AND CARBON MONOXIDE ALARMS TO BE INSTALLED (R314; R315) - PLEASE
<br />SHOW LOCATION OF THE ALARM S ON THE PLANS. A. SMOKE ALARM: IN EACH SLEEPING ROOM.
<br />(R314.3) B. SMOKE ALARM & CARBON MONOXIDE ALARM: OUTSIDE EACH SEPARATE SLEEPING
<br />AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314.3; R315.3) C. SHEET E-1 -SPECIFY
<br />UL217 FOR SMOKE DETECTOR AND UL2034/2075 FOR CARBON MONOXIDE DETECTOR ON PLAN.
<br />28).RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS. IN ADDITION TO COMPLYING WITH
<br />150.0(K)1A, LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING
<br />REQUIREMENTS: A. BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO CLEARANCE INSULATION
<br />CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING/
<br />RATING LABORATORY; AND B. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH
<br />AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM
<br />E283. AN EXHAUST FAN HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT; AND C. BE
<br />SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE
<br />ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A
<br />GASKET OR CAULK; AND D. SHALL NOT CONTAIN SCREW BASE SOCKETS.
<br />29). TANK-LESS - PROVIDE A DEDICATED 125 VOLT, 20 AMP ELECTRICAL GFCI RECEPTACLE
<br />CONNECTED TO THE ELECTRICAL PANEL WITH A 120/240 VOLT 3 CONDUCTOR 10 AWG COPPER
<br />BRANCH CIRCUIT, WITHIN 3 FEET OF THE WATER HEATER AND ACCESSIBLE TO THE WATER
<br />HEATER. (CENERGYC 150.0(N)(1)(A))
<br />30) ALL LED LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY A NATIONAL ELECTRICAL
<br />MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS THEY ARE
<br />CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE COMBINED USE OF
<br />NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN ENSURE FLICKER FREE
<br />OPERATION WHEN THE LUMINAIRE IS DIMMED. PLEASE SHOW DIMMER SWITCH(ES) ON THE
<br />PLANS. (2019 RESIDENTIAL COMPLIANCE MANUAL 6.3.1(G))
<br />(N) ELECTRICAL PLAN
<br />SCALE: 3/16" = 1'-0"
<br />ELECTRICAL PLAN &
<br />NOTES
<br />(E) POWER POLE
<br />(E) POWER METER
<br />3/16" = 1'-0"
<br />(N) SUB-PANEL
<br />PROJECT NAME: MANUEL & MARIA CASAS
<br />MAIN HOUSE ADDRESS: 2617 DEODAR ST.,
<br />SANTA ANA, CA 92705
<br />ADU ADDRESS: 2617 DEODAR ST. UNIT #2,
<br />SANTA ANA, CA 92705
|