Laserfiche WebLink
E E E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />GFCI <br />GFCI <br />CO/SD <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />R <br />R <br />R <br />R <br />3 <br />GFCI <br />GFCI <br />GFCI <br />VS <br />R <br />R <br />3 <br />EP <br />BEDROOM 2 <br />BEDROOM 3 <br />BEDROOM 4 <br />MASTER BEDROOM <br />LIVING <br />HALL <br />DINING <br />KITCHEN <br />PORCH <br />BATH <br />LAUNDRY <br />LAUNDRY <br />CLOSET <br />N <br />E1 <br />SHEET: <br />SCALE: <br />DATE: <br />11/25/2024 <br />Revision Table <br />Number <br />Date <br />Revised By <br />Description <br />1 <br />10/27/2023 <br />JO <br />PLANNING <br />2 <br />01/31/2024 <br />JO <br />PLANNING <br />3 <br />03/08/2024 <br />JO <br />BP <br />4 <br />04/02/2024 <br />JO <br />PCC <br />5 <br />11/25/2024 <br />JO <br />PCC <br />COMPA'S DESIGN SERVICES <br />949 N. IROQUOIS AVE. <br />ANAHEIM, CA 92801 <br />JUAN ORELLANA _____________ <br />ELECTRICAL NOTES <br />1.) VERIFY CONNECTION POINTS FOR POWER TELEPHONE, GAS, SEWER AND CATV SYSTEMS <br />PRIOR TO CONSTRUCTION APPROXIMATE ONLY LOCATIONS INDICATED. <br />2.) NOTE: OPENINGS AROUND ELECTRICAL PENETRATIONS, FLOORS, CEILINGS, SHALL BE FIRE <br />STOPPED USING APPROVED METHONDS TO MAINTAIN THE FIRE RATING. <br />3.) NOTE: SMOKE DETECTORS SHALL BE LOCATED AT VAULTED CEILINGS <br />4.) PROVIDE AT LEAST TWO 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS TO SERVE TO <br />KITCHEN, BREAKFAST ROOM, AND DINNING ROOM. SUNCH CIRCUITS SHALL HAVE NO OTHER <br />OUTLETS. <br />5.) PROVIDE AT LEAST ONE 20-AMPERE BRANCH CIRCUIT TO SERVE LAUNDRY APPLIANCES <br />SUNCH CIRCUIT(S) SHALL HAVE NO OTHER OUTLETS. <br />6.) ALL ALUMINUM CONDUCTORS ARE PERMITTED ONLY IF SIZE 1/0 OR LARGE, AND ONLY TO <br />FEED MAIN OR SUB-PANELS, ALL OTHER CURRENT CARRYING CONDUCTORS SHALL BE <br />COPPER" <br />7.) "BONDS GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING." <br />8.) SMOKE ALARMS SHALL BE 120-VOLT WITH BATTERY BACK-UP. <br />9.) PROVIDE 120-SMOKE ALARMS. LOCATED NO LESS THAN 3'-0" FROM AIR REGISTER. IN <br />DWELLING UNITS, A SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A <br />POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARTATE <br />SLEEPING AREA. WHEN THE DWELLING UNIT HAS MORE THAN ONE STORY AND IN DWELLING <br />WITH BASEMENT, A SMOKE ALARM SHALL BE INSTALLED ON EACH STORY AND IN THE <br />BASEMENT. IN DWELLING UNIT WHERE A STORY BASEMENT IS SPLIT INTO TOW OR MORE <br />LEVELS, THE SMOKE ALARM SHALL BE INSTALLED ON THE UPPER LEVEL, EXCEPTTHAT WHEN <br />THE LOWER LEVEL CONTAINS A SLEEPING AREA, A SMOKE ALARM SHALL BE INSTALLED ON <br />EACH LEVEL. WHEN SLEEPING ROOMS ARE ON AN UPPER LEVLE, THE SMOKE ALARMS SHALL <br />BE PLACED AT THE CEILING OF THE UPPER LEVLE IN CLOSE PROXIMITY TO THE STAIRWAY. IN <br />DWELLING UNITS WHERE THE CEILING HEIGHT OF A ROOM OPEN TO THE HALLWAY SERIVE THE <br />BEDROOMS EXCEED THAT OF THE HALLWAY BY 24 INCHES OR MORE, SMOKE ALARMS SHALL <br />BE INSTALLE DIN THE HALLWAY AND IN THE ADJACENT ROOM. SMOKE ALARMS SHALL SOUND <br />AND ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING UNIT IN WHICH ARE LOCATED. <br />10.) PERMANENTLY WIRED SMOKE DETECTOR, 110V POWERED W/BATTERY BACK-UP INSIDE EACH <br />BEDROOM. (CEILING MOUNTED, U.N.O. ) NOTE: DETECTOR SHALL SOUND AN ALARM AUDIBLE <br />IN ALL SLEEPING AREAS OF THE UNIT. <br />11.) LIGHTING IN KITCHEN AND RESTROOM SHALL BE HIGH EFFICACY. <br />12.) SPECIFY ARC-FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL CIRCUITS SUPPLYING 125- <br />VOLT, SINGLE PHASE, 20 AMPERE RECEPTACLES IN BEDROOMS. RECEPTACLES LOCATED IN <br />BATHROOMS, GARAGES, OUTDOORS, KITCHENS (WHERE RECPTACLES SERVE COUNTER TOP <br />SURFACES), SINKS (WITHIN 6FT OF THE EDGE OF THE SINK), BATHTUB AND SHOWER STALLS <br />(WITHIN 6FT OF THE EDGE OF THE BATHTUB OR SHOWER STALL) AND LAUNDRY AREAS SHALL <br />HAVE GROUND FAULT CIRCUIT-INTURRUPTER (GFCI) PROTECTION. <br />13.ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVCES (SUCH AS LIGHTS & SWITCHES) <br />INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, <br />HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS & AREAS SHALL BE PROVIDED WITH ARC- <br />FAULT CIRCUIT-INTERRUPTERS (AFCI) PROTECTION. <br />14.) ALL WALL SPACES, 2 FEET OR MORE IN WIDTH, SHALL HAVE RECEPTACLES INSTALLED SUCH <br />THAT NO POINT MEASURED HORIZONTALLY IS MORE THAN 6 FEET FROM A RECEPTACLE (12 <br />FEET MAXIMUM SPACING.) <br />15.) COUNTERTOPS IN KITCHENS, PANTRIES, BRAKFAST ROOMS, DINDING ROOMS AND SIMILAR <br />AREAS SPACES 12 INCHES OF WIDER SHALL HAVE RECEPTACLES INSTALLED SUCH THAT NO <br />POINT ALONG THE WALL IS MORE THAN 2 FEET FROM A RECEPTACLE. <br />16.) AT LEASE ONE RECEPTALCE AT GRADE LEVEL SHALL BE INSTALLED IN BOTH THE FRONT <br />AND BACK OF EACH DWELLING UNIT. <br />17.) AT LEAST ONE RECEPTACLE, IN ADDITION TO THOSE FOR SPECIFIC EQUIPMENT, SHALL BE <br />INSTALLED IN THE FOLLOWING LOCATIONS. <br /> A. IN EACH ATTACHED AND DETACHED GARAGE WITH ELECTRIC POWER. THE <br /> BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE SHALL NOT SUPPLY OUTLETS <br /> OUTSIDE OF THE GARAGE. AT LEAST ONE RECEPTACLE OUTLET SHALL BE <br /> INSTALLED FOR EACH CAR SPACE. <br /> B. IN EACH ACCESSORY BUILDING WITH ELECTRIC POWER <br /> C. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT <br />18.) ALL NONLOCKING-TYPE 125-VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED <br />TAMPER-RESISTANT <br /> RECEPTACLES. <br />19.) IN CLOSETS, LUMINAIRES SHALL BE <br /> (A) SURFACE-MOUNTED OR RECESSED INCANDESCENT OR LED WITH COMPLETELY <br />ENCLOSED LIGHT SOURCES, <br /> (B)SURFACE MOUNTED OR RECESSED FLUORESCENT LUMINAIRES, <br /> (C) SURFACE MOUNTED FLUORESCENT OR LED LUMNARIES IDENTIFIED AS SUITABLE FOR <br /> INSTALLATION WITHIN STORAGE AREAS. MINIMUM CLEARANCES BETWEEN <br /> LUMINARIAS AND THE NEAREST POINT OF STORAGE SPACE SHALL BE AS FLOLLOWS. <br /> A. 12" FOR SURFACE MOUNTED INCANDESCENT OR LED LUMINARIES WITH COMPLETELY <br />ENCLOSED LIGHT <br /> INSTALLED ON THE WALL ABOVE THE DOOR OR ON THE CEILING. <br /> B. 6" FOR SURFACE MOUNTED FLUORESCENT LUMINARIAS INSTALLED ON THE WALL <br /> ABOVE THE DOOR OR ON THE CEILING. <br /> C. 6" FOR RECESSED INCANDESCENT OR LED LUMINARIES WITH A COMPLETELY <br /> ENCLOSED LIGHT SOURCE INSTALLED IN THE WALL OR CEILING. <br /> D. 6" FOR RECESSED FLUORESCENT LUMINARIES INSTALLED IN THE WALL OR CEILING. <br /> E. SURFACE-MOUNTED FLUORESCENT OF LED LUMINARIES SHALL BE PERMITTED <br /> TO BE INSTALLED WITHIN CLOSET STORAGE SPACE WHERE IDENTIFIED FOR THIS USE. <br />20.) ALL INSTALLED LUMINARIES SHALL BE HIGH- EFFICACY. HIGH EFFICACY LIGHT SOURCES <br />INCLUDE <br /> A. PIN-BASED LINEAR OR COMPACT FLUORESCENT LAMPS (CFL) SOURCES USING ELECTRONIC <br />BALLASTS. <br /> B. PULSE-START METAL HALIDE LAMPS. <br /> C. HIGH PRESSURE SODIUM LAMPS. <br /> D. GU-24 SOCKETS CONTAINING CFL OR LED LIGHT SOURCES. <br />21.) LUMINARIES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS <br /> A. BE LISTED FOR ZERO CLEARANCE INSULATION CONTACT (IC). <br /> B. HAVE A LABEL THAT CERTIFIES THE LUMINARIES IS AIRTIGHT WITH AIR LEAKAGE <br /> LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM <br /> E283. <br /> C. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARIES HOUSING AND <br /> CEILING AND SHALL HAVE ALL <br /> AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A <br />GASKET OR CAULK. <br /> D. FOR LUMINARIES WITH HARDWIRED BALLASTS OR DRIVERS, ALLOW BALLAST OR DRIVER <br />MAINTENANCE AND <br /> REPLACEMENT TO BE READILY ACCESSIBLE TO BUILDING OCCUPANTS FROM BELOW THE <br />CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN THE CEILING. <br /> E. SHALL NOT CONTAIN SCREW BASE SOCKETS. <br /> F. SHALL CONTAIN LIGHT SOURCES THAT ARE MARKED "J8A-2016-E". <br />22.) EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. LIGHTING <br />INTEGRAL TO AN <br /> EXHAUST FAN MAY BE ON THE SAME SWITCH AS THE FAN PROVIDED THE LIGHTING CAN BE <br />SWITCHED OFF <br /> WHILE ALLOWING THE FAN TO CONTINUE TO OPERATE FOR AN EXTENDED PERIOD OF TIME. <br />23.) IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINARIES <br />IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. <br />24.) ALL JA8 COMPLAINT LIGHT SOURCES, EXCEPT THOSE IN CLOSETS LESS THAN 70 SQUARE <br />FEET AND THOSE IN <br /> HALLWAYS, SHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. 150(K)2K & TABLE <br />150.0-A CEC) JA8 <br /> COMPLIANT LIGHT SOURCES INCLUDE LIGHT SOURCES IN CEILING RECESSED DOWNLIGHT <br />LUMINARIES AND <br /> GU-24 SOCKETS CONTAINING LED LIGHT SOURCES <br />25.) ALL RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY MOUNTED TO THE RESIDENCE OR <br />OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH-EFFICACY AND MEET THE FOLLOWING <br />REQUIREMENTS: <br />A. LIGHTS SHALL COMPLY WITH ONE OF THE TWO OPTIONS BELOW: <br /> I. CONTROLLED BY A PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON <br />SHALL NOT BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION <br />SENSOR WITHIN 6 HOURS. <br /> II. CONTROLLED BY (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL OR (2) <br />ASTRONOMICAL TIME CLOCK OR (3) ENERGY MANAGEMENT CONTROL SYSTEM MEETING THE <br />REQUIREMENTS OF 150(K)3A. <br />B. LIGHTS SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE <br />TO ON THE AUTOMATIC ACTIONS OF ITEM I OR ITEM II CHOSEN ABOVE. <br />26). ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS <br />OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING <br />ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, <br />HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY <br />OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6). AT KITCHEN COUNTER, INDICATE <br />COMBINATION AFCI/GFCI RECEPTACLES <br />27). SMOKE ALARMS AND CARBON MONOXIDE ALARMS TO BE INSTALLED (R314; R315) - PLEASE <br />SHOW LOCATION OF THE ALARM S ON THE PLANS. A. SMOKE ALARM: IN EACH SLEEPING ROOM. <br />(R314.3) B. SMOKE ALARM & CARBON MONOXIDE ALARM: OUTSIDE EACH SEPARATE SLEEPING <br />AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314.3; R315.3) C. SHEET E-1 -SPECIFY <br />UL217 FOR SMOKE DETECTOR AND UL2034/2075 FOR CARBON MONOXIDE DETECTOR ON PLAN. <br />28).RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS. IN ADDITION TO COMPLYING WITH <br />150.0(K)1A, LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING <br />REQUIREMENTS: A. BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO CLEARANCE INSULATION <br />CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING/ <br />RATING LABORATORY; AND B. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH <br />AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM <br />E283. AN EXHAUST FAN HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT; AND C. BE <br />SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE <br />ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A <br />GASKET OR CAULK; AND D. SHALL NOT CONTAIN SCREW BASE SOCKETS. <br />29). TANK-LESS - PROVIDE A DEDICATED 125 VOLT, 20 AMP ELECTRICAL GFCI RECEPTACLE <br />CONNECTED TO THE ELECTRICAL PANEL WITH A 120/240 VOLT 3 CONDUCTOR 10 AWG COPPER <br />BRANCH CIRCUIT, WITHIN 3 FEET OF THE WATER HEATER AND ACCESSIBLE TO THE WATER <br />HEATER. (CENERGYC 150.0(N)(1)(A)) <br />30) ALL LED LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY A NATIONAL ELECTRICAL <br />MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS THEY ARE <br />CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE COMBINED USE OF <br />NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN ENSURE FLICKER FREE <br />OPERATION WHEN THE LUMINAIRE IS DIMMED. PLEASE SHOW DIMMER SWITCH(ES) ON THE <br />PLANS. (2019 RESIDENTIAL COMPLIANCE MANUAL 6.3.1(G)) <br />(N) ELECTRICAL PLAN <br />SCALE: 3/16" = 1'-0" <br />ELECTRICAL PLAN & <br />NOTES <br />(E) POWER POLE <br />(E) POWER METER <br />3/16" = 1'-0" <br />(N) SUB-PANEL <br />PROJECT NAME: MANUEL & MARIA CASAS <br />MAIN HOUSE ADDRESS: 2617 DEODAR ST., <br />SANTA ANA, CA 92705 <br />ADU ADDRESS: 2617 DEODAR ST. UNIT #2, <br />SANTA ANA, CA 92705