Laserfiche WebLink
WH <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W <br />C / W C / W <br />C / W <br />C / W <br />C / W <br />H / W <br />H / W <br />H / W <br />H / W <br />H / W <br />C / W C / W <br />C / W <br />C / W <br />N <br />PB1 <br />SHEET: <br />SCALE: <br />DATE: <br />04/15/2025 <br />Revision Table <br />Number <br />Date <br />Revised By <br />Description <br />1 <br />10/27/2023 <br />JO <br />PLANNING <br />2 <br />01/31/2024 <br />JO <br />PLANNING <br />3 <br />03/08/2024 <br />JO <br />BP <br />4 <br />04/02/2024 <br />JO <br />PCC <br />5 <br />11/25/2024 <br />JO <br />PCC <br />6 <br />04/15/2025 <br />JO <br />PCC <br />COMPA'S DESIGN SERVICES <br />949 N. IROQUOIS AVE. <br />ANAHEIM, CA 92801 <br />JUAN ORELLANA _____________ <br />PLUMBING NOTES <br />1.) WATER CLOSETS SHALL HAVE AN AVERAGE WATER CONSUMPTION OF NOT MORE THAN <br />1.28 GALLONS PER FLUSH. <br />2.) SHOWER HEADS SHALL HAVE A WATER FLOW NOT TO EXCEED 1.8 GALLONS PER MINUTE <br />AT 80 PSI. <br />3.) THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS <br />PER MINUTE AT 60 PSI. <br />4.) FAUCETS IN KITCHENS SHALL HAVE A WATER FLOW NOT TO EXEED 1.8 GALLONS PER <br />MINUTE AT 60 PSI AND MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM <br />RATE, BUT NOT EXCEED 2.2 GALLONS PER MINUTE, AND MUST DEFAULT TO A MAXIMUM <br />FLOW RATE OF 1.8 GALLONS PER MINUTE. <br />5.) GAS WATER HEATER SHALL HAVE ALL THE FOLLOWING COMPONENTS: <br /> A. A 120V ELECTRICAL RECEPTACLE WITHIN 3 FEET FROM THE WATER HEATER AND <br />ACCESSIBLE WITH NO OBSTRUCTIONS. <br /> B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE BETWEEN OUTSIDE <br />AND WATER HEATER. <br /> C. A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF <br />THE INSTALLED WATER HEATER AND <br /> ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. <br /> D. A GAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR. <br />6.) APPLIANCES IN ATTICS SHALL BE ACCESSIBLE THROUGH AN ACCESS OPENING AT <br />LEAST A 22x30 INCH. THE APPLIANCE SHALL NOT BE MORE THAN 20 FEET FROM THE <br />OPENING ALONG A PATHWAY WITH A SOLID FLOOR NOT LESS THAN 24" WIDE. PROVIDE A <br />30x30 INCH WORKING PLATFORM IN FRONT OF THE APPLIANCE AND PROVIDE A 120-VOLT <br />OUTLET WITH A LIGHT FIXTURE NEAR THE APPLIANCE WITH THE LIGHT SWITCH LOCATED <br />AT THE ENTRANCE TO THE PASSAGEWAY. <br />7.) DOMESTIC DISHWASHERS REQUIRE AN APPROVED DISWAHER AIR GAP FITTING ON THE <br />DISCHARGE SIDE OF THE DISHWASHER. LISTED AIR GAPS SHALL BE INSTALLED WITH THE <br />FLOOD-LEVEL (Fl) MARKING AT OR ABOVE THE FLOOD-LEVEL OF THE SINK OR <br />DRAINBOARD, WHICEVER IS HIGHER. <br />8.) INSTANTANEOUS WATER HEATERS WITH AN INPUT RATING GREATER THAN 6.8 kbtu/HR <br />SHALL HAVE ISOLATION VALVES ON BOTH THE COLD-WATER SUPPLY AND TE HOT WATER <br />PIPE LEAVING THE WATER HEATER, AND HOSE BIBBS OR OTHER FITTINS ON EACH VALVE <br />FOR FLUSHING THE WATER HEATER WHEN THE VALVES ARE CLOSED. <br />9. ) ALL WATER LINES SHALL BE COPPER <br />10. ) SEWER AND VENT PIPES SHALL BE ABS <br />11.) WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. <br />604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING <br />SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 604 OF <br />THE CPS, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURERS <br />RECOMMENDED INSTALLATION STANDARDS. CPVC WATER PIPING REQUIRES A <br />CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC 604.1.1(d) OF THE CPC PRIOR TO <br />PERMIT ISSUANCE. <br />12.) ALL HOSE BIBS MUST HAVE AN APPROVED ANTI-SIPHON DEVICE. <br />13.) MECHANICAL EQUIPMENT LOCATED IN A GARAGE SHALL BE GUARDED AGAINST <br />DAMAGE BY BEING INSTALLED BEHIND PROTECTIVE BARRIERS OR BY BEING ELEVATED OR <br />LOCATED OUT OF THE NORMAL PATH OF VEHICLES. <br />14.) SHOWER COMPARTMENTS SHALL BE NO LESS THAN 1,024 SQUARE INCHES AND ALSO <br />BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. <br />15.) SHOWER AND TUB-SHOWER COMBINATIONS SHALL PROVIDE WITH INDIVIDUAL <br />CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION <br />PRESSURE BALANCE/THERMOSTATIC MISSING VALVE TYPE THAT PROVIDE SCALD AND <br />THERMAL SHOCK PROTECTION. THESE VALVES SHALL CONFORM TO ASSE 1016 OR AMSE <br />A112.18.1/CSA B125.1. HANDLE POSITION STOPS SHALL BE PROVIDED ON SUCH VALVES <br />AND SHALL BE ADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A <br />MAXIMUM MIXED WATER SETTING OF 120 DEGREES FAHRENHEIT. WATER HEATING <br />THERMOSTATS SHALL NOT BE CONSIDER A SUITABLE CONTROL FOR MEETING THIS <br />PROVISION. <br />16). INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORDANCE WITH CPC <br />SECTION 609.11.1 AND SECTION 609.11.2 <br />17). BATHROOM - A SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE <br />SCALD AND THERMAL SHOCK PROTECTION PROTECTION IN ACCORDANCE WITH ASSE 1016 <br />OR ASME A112.18.1/CSA B125.1. (CPC 408.3). B. SHOWER WALL COVERINGS SHALL BE <br />NONABSORBENT SUCH AS CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72" ABOVE <br />FLOOR AT SHOWER OR TUBS WITH SHOWERS. (R307.2). I. CEMENT, FIBER-CEMENT, FIBER- <br />MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM <br />BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND <br />WALL AND CEILING PANELS IN SHOWER AREAS. (R702.4.2). C. WATER CLOSET SHALL HAVE <br />15” TO ANY WALL OR OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24” CLEAR <br />SPACE IN FRONT. DIMENSION ON THE PLANS. (407.5 CPC). <br />(N) PLUMBING PLAN <br />SCALE: 1/8" = 1'-0" <br />PLUMBING PLAN & <br />NOTES <br />(E) WATER METER <br />1/8" = 1'-0" <br />(E) 4" SEWER LINE <br />G.C. TO VERIFY AND LOCATED <br />EXISTING SEWER LINE BEFORE <br />CONSTRUCTION. <br />(N) ABS 4" SEWER LINE TO CONNECT TO <br />EXISTING SEWER LINE. <br />G.C. TO VERIFY AND LOCATED EXISTING <br />SEWER LINE BEFORE CONSTRUCTION. <br />(N) APPROX. <br />P.O.C. <br />PROJECT NAME: MANUEL & MARIA CASAS <br />MAIN HOUSE ADDRESS: 2617 DEODAR ST., <br />SANTA ANA, CA 92705 <br />ADU ADDRESS: 2617 DEODAR ST. UNIT #2, <br />SANTA ANA, CA 92705 <br />Juan <br />Orellana <br />(N) ADU TANKLESS <br />WATER HEATER <br />(E) GAS METER <br />(N) 7' GAS LINE <br />(N) 1/2" HOT WATER LINE <br />(N) 1/2" COLD <br />WATER LINE <br />(E) MAIN <br />WATER VALVE