My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2528 N Oakmont Ave - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Oakmont Ave
>
2528 N Oakmont Ave
>
2528 N Oakmont Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:48 AM
Creation date
2/13/2026 5:00:47 AM
Metadata
Fields
Template:
Plan
Permit Number
20186227
Full Address
2528 N Oakmont Ave
Street Number
2528
Street Direction
N
Street Name
Oakmont
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: A 5/16/2025 <br />MICHAEL HAVNAER <br />2528 OAKMONT AVE, SANTA <br />ANA, CA, 92706 <br />PROJECT NUMBER: <br /> 109R-528HAVN <br />SHEET <br />DESIGNER: <br />CHIPPY PRINCE <br />CUSTOMER RESIDENCE: <br />TEL. (562) 760-8480 <br />APN: 003-050-35 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />PV-4.2 <br />ELECTRICAL CALCS <br />Inverter Calculations <br />Each Inverter has the following values which are calculated following these formulas: <br />Inverter X: <br />Load)(690.8(B)(1)) <br />[((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc <br />* (# Modules / String) <br />Inverter Powerwall 3 1707000-xx-y <br />Inverter Powerwall 3 1707000-xx-y <br />Combinded Inverter Output: <br />Wire Calculations <br />Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature <br />calculations from 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on <br />the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is <br />constrained using the 75°C column with the continuous duty uprating or the 90°C column with the <br />relevant ambient temperature and raceway fill adjustments without the continuous duty uprating <br />per 690.8(B), whichever is the lower value will govern conductor sizing. Non-PV Circuit <br />Conductors use the ampacity in the 75°C column or the 90°C column with the relevant ambient <br />temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating <br />of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated <br />current. <br />Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current <br />ALLOWABLE BACKFEED: <br /> ALLOWABLE BACKFEED = MAIN PANEL RATING = 400 A <br /> BREAKERS IN INTERCONNECTION PANEL: 100 A BREAKERS + 200 A GATEWAY <br />BREAKER =300 <br /> 300 A ≤ 400 A INTERCONNECTION <br /> MEETS CEC 2022 705.12(B)(3)(3) REQUIREMENTSWIRE CALCULATIONS
The URL can be used to link to this page
Your browser does not support the video tag.