Laserfiche WebLink
PAGE <br />REV: C1 8/30/2025 <br />MICHAEL HAVNAER <br />2528 OAKMONT AVE, SANTA  <br />ANA, CA, 92706 <br />PROJECT NUMBER: <br />  109R-528HAVN <br />SHEET <br />DESIGNER: <br />CHIPPY PRINCE <br />CUSTOMER RESIDENCE: <br />TEL. (562) 760-8480 <br />APN: 003-050-35 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />BACKUP LOADS TABLE <br />LOAD #OCPD  <br />RATING LABEL <br />1 100A - 2P SUB PANEL 1 <br />2 100A - 2P SUB PANEL 2 <br />3 60A - 2P A/C 1 <br />4 50A-2P A/C 2 <br />SUB PANEL 1 LOADS <br />5 50A - 2P OVEN <br />6 30A - 2P DRYER <br />7 20A - 1P BEDROOM 1 LIGHTS <br />8 20A - 1P BEDROOM 1 OUTLETS <br />9 20A - 1P BEDROOM 2 LIGHTS <br />10 20A - 1P BEDROOM 2 OUTLETS <br />11 20A - 1P BEDROOM 3 LIGHTS <br />12 20A - 1P BEDROOM 3 OUTLETS <br />13 20A - 1P BEDROOM 4 LIGHTS <br />14 20A - 1P BEDROOM 4 OUTLETS <br />15 20A - 1P BEDROOM 5 LIGHTS <br />16 20A - 1P BEDROOM 5 OUTLETS <br />17 20A - 1P KITCHEN LIGHTS <br />18 20A - 1P KITCHEN LIGHTS <br />19 20A - 1P FRIDGE  <br />20 20A - 1P OUTDOOR LIGHTS <br />21 20A - 1P GARAGE LIGHTS <br />SUB PANEL 2 LOADS <br />22 30A - 2P MICROWAVE/OVEN  <br />COMBO UNIT <br />23 15A - 1P BATHROOM 1 LIGHTS <br />24 15A - 1P BATHROOM 1 OUTLETS <br />25 15A - 1P BATHROOM 2 LIGHTS <br />26 15A - 1P BATHROOM 2 OUTLETS <br />27 15A - 1P BATHROOM 3 LIGHTS <br />28 15A - 1P BATHROOM 3 OUTLETS <br />29 15A - 1P BATHROOM 4 LIGHTS <br />30 15A - 1P BATHROOM 4 OUTLETS <br />31 15A - 1P BATHROOM 5 LIGHTS <br />32 15A - 1P BATHROOM 5 OUTLETS <br />33 15A - 1P BATHROOM 6 LIGHTS <br />34 15A - 1P BATHROOM 6 OUTLETS <br />35 20A - 1P FRIDGE <br />36 20A - 1P LIVING ROOM LIGHTS <br />37 20A - 1P LIVING ROOM OUTLETS <br />38 20A - 1P OFFICE LIGHTS <br />39 20A - 1P OFFICE OUTLETS <br />40 20A - 1P OUTDOOR LIGHTS <br />41 20A - 1P KITCHEN APPLIANCE <br />#ESTAMP <br />PV-4.3 <br />BACKUP LOAD CALCS <br />BACKUP LOAD CALCS <br />ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE  <br />MAIN SERVICE PANEL. <br />BACKED UP LOADS CALCULATION: <br />(19200 VA)/ 240V = 80 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. <br />THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 80A. <br />(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) =  <br />80 A X 1.25 = 100A; <br />BACKED UP LOADS PANEL BREAKER = 200A <br />100A ≤ 200A <br />THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. <br />AC WIRE SIZING FOR BACKED UP LOADS PANEL: <br />MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />80 A X 1.25 = 100A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE  <br />310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = <br />0.91 X 0.45 X 115A = 47.09A <br />TERMINAL RATING[110.14(C)] = <br />3 AWG, 75°C RATED = 100A <br />47.09A < 100A   TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />100A ≤ 200A   3 AWG AMPACITY OK <br />THEREFORE 3 AWG IS SUFFICIENT. <br />  <br />   <br />C