1. MECHANICAL VENTILATION CAPABLE OF PROVIDING 5 AIR CHANGES PER HOUR IN BATHROOMS
<br />CONTAINING TUBS OR SHOWERS, AND SIMILAR ROOMS, IF REQUIRED FANS ARE NOT
<br />ACCEPTABLE IN ROOMS CONTAINING TUBS OR SHOWERS). THE POINT OF DISCHARGE SHALL BE
<br />AT LEAST 3-FEET FROM ANY OPENING.
<br />2. DOORS AND WINDOWS SHALL BE FULLY WEATHERS TRIPPED.
<br />3. OPENINGS SHALL BE CAULKED AND SEALED, I.E., AROUND JOINTS IN WINDOWS, WALL SOLE
<br />PLATES, OPENINGS FOR UTILITY PIPING, AND WIRING, ETC.
<br />4. PROVIDE A THERMOSTAT THAT HAS AUTOMATIC SETBACK CAPABILITY FOR TWO PERIODS
<br />DURING 24 HOURS.
<br />5. FURNACE INSTALLATION SHALL MEET ALL LISTED CLEARANCES.
<br />6. DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE.
<br />CARBON MONOXIDE ALARM REQUIREMENTS:
<br />A) AN APPROVED CARBON MONOXIDE SHALL BE INSTALLED FOR NEW CONSTRUCTION AND
<br />ALTERATION REQUIRING PERMIT EXCEEDING $1000. CRC R315.1, R315.2
<br />B) CARBON MONOXIDE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH
<br />BATTERY BACKUP. CRC R315.1.1.
<br />C) CO ALARMS SHALL BE LISTED FOR COMPLIANCE WITH UL 2034, UL 2075, AND/OR NFPA 720.
<br />CRC R315.3
<br />D)CO ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE
<br />VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING
<br />E)CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF
<br />ONE ALARM WILL ACTIVATE ALL ALARMS IN THE INDIVIDUAL DWELLING UNIT. CRC R315.1.2.
<br />F)IN EXISTING DWELLING UNIT A CO ALARM IS PERMITTED TO BE BATTERY OPERATED WHERE
<br />REPAIR OR ALTERATION DO NOT RESULT IN THE REMOVAL OF WALL OR CEILING FINISHES OR
<br />THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. CRC R315.1.1
<br />EXCEPTIONS 2
<br />7. HARDWIRED SMOKE DETECTOR WITH A BATTERY BACK UP IN EACH SLEEPING ROOM AND AT A
<br />POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SLEEPING
<br />AREA: A DETECTOR SHALL BE LOCATED AT EACH STORY AND BASEMENT, ON THE UPPER LEVEL
<br />OF SPLIT LEVEL STORIES AND BOTH LEVELS IF SLEEPING AREA IS ON LOW LEVEL. WHERE THE
<br />CEILING HEIGHT OF A ROOM OPEN TO THE HALLWAY SERVING BEDROOMS EXCEEDS THAT OF
<br />THE HALLWAY BY 24-INCHES OR MORE, DETECTORS SHALL BE INSTALLED IN THE HALLWAY AND
<br />NEAR THE HIGH POINT OF THE ADJOINING ROOM. (BATTERY OPERATED SMOKE DETECTOR
<br />PERMITTED IN EXISTING CONSTRUCTION ONLY).
<br /> 2a. SMOKE DETECTOR SHALL SOUND AND ALARM AUDIBLE IN ALL SLEEPING AREAS.
<br /> 2b. SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTIVATION OF ONE ALARM
<br /> ACTIVATES ALL OF THE ALARMS. (CBC 907.2.10.3)
<br />8. IN ALL DWELLINGS PROVIDED W/ 110 vt 15 OR 20 AMP OUTLETS TO BE ARC-FAULT INTERRUPTERS
<br /> ARC FAULT REQD. IN ALL BRANCH CIRCUITS EXCEPT KITCHEN, BATHROOM, LAUNDRY
<br /> 2013 CEC 210.12 (B)
<br />9. IF ELECTRICAL PANEL TO BE UPGRADE PROVIDE NEW 1/2" X 20' LONG REBAR FOR UFER GROUND
<br /> BONDED TO COLD WATER PIPE.
<br />10. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT SINGLE PHASE 15 & 20 AMP RECEPTACLE
<br /> OUTLETS INSTALLED IN DWELLING SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT
<br /> INTERRUPTERS NEC SECTION 210-120(B)
<br />11. FIRST SWITCH TO THE ENTRANCE OF BATHROOM(S) AN OR KITCHEN SHALL BE A FLUORESCENT
<br /> FIXTURE IN TYPE OR WITH BALLAST.
<br />12. FLUORESCENT LIGHT RATED AT NOT LESS THAN 40 LUMENS PER WATT FOR GENERAL LIGHTING
<br /> IN KITCHENS AND IN BATHROOMS WITH TUB OR SHOWER PER TITLE 24 SECTION 150(K) 1 TO 4
<br /> (SEE EXCEPTIONS).
<br />13. LUMINARIES RECESSED IN INSULATED CEILING MUST BE RATED FOR DIRECT INSULATION
<br /> CONTAC (IC), CERTIFIED AS AIRTIGHT CONSTRUCTION AND MUST HAVE HASSLED GASKET OR
<br /> CAULKING BETWEEN THE HOUSING AND CEILING
<br />14. IN DWELLING UNITS, A WALL RECEPTACLE OUTLET SHALL BE INSTALLED IN THE BATHROOM
<br /> WITHIN 36" OF EACH BASIN LOCATION.
<br />15. PROVIDE TAMPER RESISTANT RECEPTACLES 2013 CEC 406.12
<br />16. SMOKE AND CARBON MONOXIDE DETECTORS ARE REQUIRED TO BE INTERCONNECTED SUCH
<br />THAT ACTIVATION OF ONE ALARM WILL RESULT IN THE ACTIVATION OF ALL ALARMS WITHIN THE
<br />DWELLING UNIT (CRC R314.4 AND R315.5)
<br />WALL SWITCH SINGLE POLE :
<br />WALL POLE SWITCHS
<br />3S WALL SWITCH 3-WAY
<br />DS WALL SWITCH W/DIMMER
<br />DUPLEX 110 V RECEPTACLE OUTLET
<br />ARC FAULT CIRCUIT INTERUPTERAFCI
<br />FLUORESCENT LIGHTF
<br />RECESSED LIGHT FIXTURE
<br />LIGHT SYMBOLS:
<br />SMOKE DETECTORS:
<br />CEILING MOUNTED
<br />HARDWIRED W/ BATTERY BACK-UP
<br />(SEE NOTE 7)
<br />SD/HW
<br />EXHAUST FANS:
<br />EXHAUST FAN
<br />C O CARBON MONOXIDE DETECTOR
<br />WEATHERPROOF SWITCH SINGLE POLEWPS
<br />WEATHERPROF DUPLEXWP
<br />GFCI
<br />WALL HUNG LIGHT FIXTUREF
<br />MS WALL SWITCH SENSOR WITH PHOTO
<br />GROUND FAULT INTERRUPTER
<br />(1) 20 AMP. DEDICATED OWN CIR. BREAKER
<br /> RECESSED CAN LIGHT FIXTURE (FLUORESCENT).
<br /> SPECIALTY LIGHT (IE STRIP LIGHTING
<br /> OVER VANITY).
<br />2-TUBE X 4'-0" FLUORESCENT SURFACE
<br />LIGHT FIXTURE.
<br /> PROVIDE J-BOX.
<br /> PUSH BUTTON.
<br />vs VACANCY SENSOR LIGHTING 150 (K) 2J CEnC
<br />FUTURE 240V
<br />EV CHARGING
<br />F FAN WITH FLUORESCENT LIGHT
<br /> 220 V EV CHARGING BOX
<br /> 40 A ELECTRIC VEHICLE CHARGING
<br />2022 RESIDENTIAL LIGHTING STANDARDS
<br />THE FOLLOWING IS SUMMARY FOR LOW-RISE RESIDENTIAL BUILDING LIGHTING REQUIREMENTS
<br />FROM 2019 BUILDING
<br />ENERGY EFFICIENCY STANDARDS SECTION 150.0(K) EFFECTIVE ON 2022(SEE
<br />WWW.ENERGY.CA.GOV/TITLE24 FOR MORE DETAILS).
<br />HABITABLE SPACES
<br />(LIVING ROOMS, DINING ROOMS, KITCHENS, AND BEDROOMS)
<br />SHALL BE HIGH EFFICACY AND SHALL HAVE READILY ACCESSIBLE WALL-MOUNTED DIMMING
<br />CONTROLS.
<br />EXCEPTIONS:
<br />·CEILING FANS MAY PROVIDE CONTROL OF INTEGRATED LIGHTING VIA REMOTE CONTROL.
<br />BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS AND WALK-IN CLOSETS
<br />ALL LIGHTING SHALL BE HIGH EFFICACY. EACH ROOM MUST HAVE AT LEAST 1 LUMINAIRE IS
<br />CONTROLLED BY EITHER AN OCCUPANCY OR VACANCY SENSOR PROVIDING AUTOMATIC-OFF
<br />FUNCTIONALITY. EXHAUST FANS SHALL BE CONTROLLED SEPARATELY FROM LIGHTING
<br />SYSTEMS OR UTILIZE A DEVICE WHERE LIGHTING CAN BE TURN OFF WHILE THE FAN IS RUNNING.
<br />NAVIGATION LIGHTING (NIGHT LIGHTS, STEP LIGHTS, AND PATH LIGHTS)
<br />SHALL BE HIGH EFFICACY EXCEPT IF LESS THAN 5 WATTS.
<br />CABINET LIGHTING
<br />(DRAWERS, CABINETS, AND LINEN CLOSETS)
<br />ALL LIGHTING SHALL BE HIGH EFFICACY EXCEPT LIGHTING INTERNAL TO DRAWERS, CABINETRY
<br />AND LINEN CLOSETS WITH AN EFFICACY OF ≥ 45 LUMENS PER WATT. LIGHTING INTERNAL TO
<br />DRAWERS AND CABINETRY WITH OPAQUE FRONTS OR DOORS SHALL HAVE CONTROLS THAT
<br />TURN THE LIGHTS OFF WHEN THE DRAWER OR DOOR IS CLOSED.
<br />INTEGRATED DEVICE LIGHTING
<br />LIGHTING INTEGRAL TO EXHAUST FANS, KITCHEN RANGE HOODS, BATH VANITY MIRRORS AND
<br />GARAGE DOOR OPENER ARE EXEMPT FROM HIGH EFFICACY REQUIREMENTS.
<br />RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS
<br />§SHALL BE HIGH EFFICACY, LISTED FOR ZERO CLEARANCE INSULATION CONTACT (IC),
<br />LABELED AS AIRTIGHT (AT), SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND
<br />CEILING, ALLOW BALLAST OR DRIVER MAINTENANCE AND REPLACEMENT TO BE READILY
<br />ACCESSIBLE TO BUILDING OCCUPANTS FROM BELOW THE CEILING WITHOUT REQUIRING THE
<br />CUTTING OF HOLES IN THE CEILING, SHALL NOT CONTAIN SCREW BASE SOCKETS (E26),
<br />COMPLY WITH JA8 ELEVATED TEMPERATURE REQUIREMENTS FOR ENCLOSED OR RECESSED
<br />LUMINAIRES.
<br />§FOR ALTERATIONS OF EXISTING CEILING-RECESSED LUMINAIRE WITH SCREW-BASED SOCKET
<br />MUST USE NEW JA8-COMPLIANCE TRIM KITS OR LAMPS DESIGNED FOR USE WITH RECESSED
<br />DOWN-LIGHTS OR LUMINAIRES.
<br />BLANK ELECTRICAL BOXES
<br />THE NUMBER OF ELECTRICAL BOXES THAT ARE MORE THAN 5 FEET ABOVE THE FINISH FLOOR
<br />AND DO NOT CONTAIN A LUMINAIRE OR OTHER DEVICE SHALL BE NO GREATER THAN THE
<br />NUMBER OF BEDROOMS. THESE ELECTRICAL BOXES MUST BE SERVED BY A DIMMER, VACANCY
<br />SENSOR CONTROL, LOW VOLTAGE WIRING OR FAN SPEED CONTROL.
<br />INDEPENDENT CONTROLS
<br />§INTEGRATED LIGHTING OF EXHAUST FANS SHALL BE CONTROLLED INDEPENDENTLY FROM
<br />THE FANS.
<br />§THE FOLLOWING SHALL BE CONTROLLED SEPARATELY FROM CEILING-INSTALLED LIGHTING:
<br />UNDER CABINET LIGHTING, UNDERSHELF LIGHTING, INTERIOR LIGHTING OF DISPLAY
<br />CABINETS, AND SWITCHED OUTLETS.
<br />OUTDOOR LIGHTING
<br />ALL PERMANENTLY INSTALLED OUTDOOR LIGHTING SHALL BE HIGH EFFICACY AND MUST BE
<br />CONTROLLED BY A MANUAL ON AND OFF SWITCH AND USE ONE OF THESE AUTOMATIC
<br />CONTROL TYPES:
<br />§PHOTOCELL AND MOTION SENSOR, OR
<br />§PHOTOCELL AND AUTOMATIC TIME SWITCH CONTROL, OR
<br />§ASTRONOMICAL TIME CLOCK THAT AUTOMATICALLY TURN OUTDOOR LIGHTING OFF DURING
<br />DAYLIGHT HOURS, OR
<br />ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) THAT PROVIDES THE FUNCTIONALITY OF AN
<br />ASTRONOMICAL TIME CLOCK. EMCS DOES NOT HAVE AN OVERRIDE OR BYPASS THAT
<br />ALLOWS THE LUMINARIES TO BE ALWAYS ON AND IS PROGRAMMED TO AUTOMATICALLY
<br />TURN THE OUTDOOR LIGHTING OFF DURING DAYLIGHT HOURS.
<br />MOTION
<br />(SENSOR
<br />W/ PHOTO)
<br />CONTROL
<br />*WP
<br />WEATHER-PROOF
<br />GFI/WP
<br />$$
<br />3
<br />3
<br />$$3
<br />3
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI
<br />$
<br />$
<br />3
<br />3
<br />$$
<br />3
<br />3
<br />AFCI
<br />$
<br />$
<br />AFCI
<br />AFCI
<br />GFI
<br />GFI
<br />GFI
<br />GFI GFI
<br />GFI
<br />GFI
<br />$
<br />$$
<br />GFI
<br />$
<br />M
<br />$
<br />M
<br />VS
<br />GFI
<br />$
<br />$
<br />$
<br />GFI GFI
<br />$
<br />GFI
<br />GFI
<br />GFI
<br />D
<br />D
<br />AFCI
<br />*WP
<br />WEATHER-PROOF
<br />GFI/WP
<br />*WP
<br />GFI/WP
<br />VENT
<br />PROVIDE CLOTHES
<br />DRYER MOISTURE
<br />EXHAUST DUCT.
<br />(MIN 4" DIA. TO THE
<br />OUTSIDE & EQUIP. W/
<br />A BACK DRAFT
<br />DAMPER. EXHAUST
<br />DUCT LENGTH IS
<br />LIMITED TO 14' W/
<br />(2) ELBOWS
<br />50
<br />
<br />C
<br />F
<br />M
<br />280 CFM
<br />REF
<br />W/H
<br />50 CFM
<br />W/D
<br />50 CFM
<br />50
<br />
<br />C
<br />F
<br />M
<br />100 CFM
<br />50 CFM
<br />SD/HW
<br />C O
<br />SD/HW
<br />SD/HW
<br />SD/HW
<br />C O
<br />C O
<br />CO
<br />N
<br />D
<br />E
<br />N
<br />S
<br />E
<br />R
<br />EL
<br />E
<br />C
<br />.
<br />DN
<br />12
<br />UP
<br />2
<br />1
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI
<br />VS
<br />GREE SAPPHIRE 12000
<br />BTU 1-TON DUCTLESS
<br />MINI SPLIT
<br />ATTIC
<br />ACCESS
<br />30x30
<br />MI
<br />N
<br />I
<br />
<br />S
<br />P
<br />L
<br />I
<br />T
<br />(N) SUB PANEL
<br />ELECTRIC
<br />100 AMP
<br />50
<br />
<br />C
<br />F
<br />M
<br />REF
<br />50 CFM
<br />50
<br />
<br />C
<br />F
<br />M
<br />100 CFM
<br />50 CFM
<br />SD/HW
<br />C O
<br />SD/HW
<br />SD/HW
<br />SD/HW
<br />C O
<br />C O
<br />W/H
<br />CO
<br />N
<br />D
<br />E
<br />N
<br />S
<br />E
<br />R
<br />EL
<br />E
<br />C
<br />.
<br />PAD FOR
<br />COMPRESSOR SHALL
<br />BE A MIN. OF 3" ABOVE
<br />THE GRADE
<br />(N) TANKLESS WATER
<br />HEATER 6.6 GPM
<br />160000 BTU 120 VOLT
<br />RES. NATURAL GAS
<br />FOR OUTDOOR INSTAL.
<br />IN THE NEW ADU MUST
<br />BE FLUSHED WITHIN
<br />THE WALL
<br />280 CFM
<br />50 CFM
<br />3/8"=1'-0"
<br />DE
<br />S
<br />I
<br />G
<br />N
<br />E
<br />R
<br />:
<br />TH
<br />E
<br />S
<br />E
<br />
<br />D
<br />R
<br />A
<br />W
<br />I
<br />N
<br />G
<br />S
<br />,
<br />
<br />D
<br />E
<br />S
<br />I
<br />G
<br />N
<br />
<br />A
<br />N
<br />D
<br />
<br />S
<br />P
<br />E
<br />C
<br />I
<br />F
<br />I
<br />C
<br />A
<br />T
<br />I
<br />O
<br />N
<br />S
<br />
<br />A
<br />R
<br />E
<br />
<br />T
<br />H
<br />E
<br />
<br />P
<br />R
<br />O
<br />P
<br />E
<br />R
<br />T
<br />Y
<br />
<br />A
<br />N
<br />D
<br />
<br />C
<br />O
<br />P
<br />Y
<br />
<br />R
<br />I
<br />G
<br />H
<br />T
<br />
<br />O
<br />F
<br />
<br />Z
<br />A
<br />H
<br />A
<br />
<br />A
<br />R
<br />C
<br />H
<br />
<br />D
<br />E
<br />S
<br />I
<br />G
<br />N
<br />
<br />A
<br />N
<br />D
<br />
<br />S
<br />H
<br />A
<br />L
<br />L
<br />
<br />N
<br />O
<br />T
<br />
<br />B
<br />E
<br />
<br />U
<br />S
<br />E
<br />D
<br />
<br />O
<br />N
<br />
<br />A
<br />N
<br />Y
<br />
<br />O
<br />T
<br />H
<br />E
<br />R
<br />
<br />W
<br />O
<br />R
<br />K
<br />
<br />E
<br />X
<br />C
<br />E
<br />P
<br />T
<br />
<br />B
<br />Y
<br />
<br />A
<br />G
<br />R
<br />E
<br />E
<br />M
<br />E
<br />N
<br />T
<br />
<br />W
<br />I
<br />T
<br />H
<br />
<br />
<br />Z
<br />A
<br />H
<br />A
<br />
<br />A
<br />R
<br />C
<br />H
<br />
<br />D
<br />E
<br />S
<br />I
<br />G
<br />N
<br />.
<br />
<br />W
<br />R
<br />I
<br />T
<br />T
<br />E
<br />N
<br />
<br />
<br />
<br />
<br />D
<br />I
<br />M
<br />E
<br />N
<br />S
<br />I
<br />O
<br />N
<br />S
<br />
<br />S
<br />H
<br />A
<br />L
<br />L
<br />TA
<br />K
<br />E
<br />
<br />R
<br />E
<br />F
<br />E
<br />R
<br />E
<br />N
<br />C
<br />E
<br />
<br />O
<br />V
<br />E
<br />R
<br />
<br />S
<br />C
<br />A
<br />L
<br />E
<br />D
<br />
<br />D
<br />I
<br />M
<br />E
<br />N
<br />S
<br />I
<br />O
<br />N
<br />S
<br />
<br />A
<br />N
<br />D
<br />
<br />S
<br />H
<br />A
<br />L
<br />L
<br />
<br />B
<br />E
<br />
<br />V
<br />E
<br />R
<br />I
<br />F
<br />I
<br />E
<br />D
<br />
<br />O
<br />N
<br />
<br />T
<br />H
<br />E
<br />
<br />J
<br />O
<br />B
<br />
<br />S
<br />I
<br />T
<br />E
<br />,
<br />
<br />A
<br />N
<br />Y
<br />
<br />D
<br />I
<br />S
<br />C
<br />R
<br />E
<br />P
<br />A
<br />N
<br />C
<br />Y
<br />
<br />S
<br />H
<br />A
<br />L
<br />L
<br />
<br />B
<br />E
<br />
<br />B
<br />R
<br />O
<br />U
<br />G
<br />H
<br />T
<br />
<br />T
<br />O
<br />
<br />T
<br />H
<br />E
<br />
<br />N
<br />O
<br />T
<br />I
<br />C
<br />E
<br />
<br />O
<br />F
<br />
<br />Z
<br />A
<br />H
<br />A
<br />
<br />A
<br />R
<br />C
<br />H
<br />
<br />D
<br />E
<br />S
<br />I
<br />G
<br />N
<br />
<br />P
<br />R
<br />I
<br />O
<br />R
<br />
<br />T
<br />O
<br />
<br />T
<br />H
<br />E
<br />
<br />C
<br />O
<br />M
<br />M
<br />E
<br />N
<br />C
<br />E
<br />M
<br />E
<br />N
<br />T
<br />
<br />O
<br />F
<br />
<br />A
<br />N
<br />Y
<br />
<br />W
<br />O
<br />R
<br />K
<br />DRAWN
<br />CHECKED
<br />R.H
<br />DATE
<br />11-06-2024
<br />SCALE
<br />JOB NO.
<br />24-031
<br />SHEET
<br />OF SHEETS
<br />90
<br />9
<br />-
<br />2
<br />4
<br />6
<br />-
<br />1
<br />2
<br />0
<br />4
<br />25
<br />5
<br />
<br />N
<br />
<br />D
<br />
<br />S
<br />T
<br />.
<br />
<br />S
<br />U
<br />I
<br />T
<br />E
<br />
<br />4
<br />0
<br />1
<br />
<br />L
<br />,
<br />SA
<br />N
<br />
<br />B
<br />E
<br />R
<br />N
<br />A
<br />R
<br />D
<br />I
<br />N
<br />O
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />4
<br />0
<br />1
<br />AR
<br />C
<br />H
<br />
<br />D
<br />E
<br />S
<br />I
<br />G
<br />N
<br />ZA
<br />H
<br />A
<br />A
<br />R
<br />C
<br />H
<br />D
<br />E
<br />S
<br />I
<br />G
<br />N
<br />1
<br />@
<br />G
<br />M
<br />A
<br />I
<br />L
<br />.
<br />C
<br />O
<br />M
<br />OW
<br />N
<br />E
<br />R
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />J.D
<br />GA
<br />R
<br />A
<br />G
<br />E
<br />
<br />C
<br />O
<br />N
<br />V
<br />E
<br />R
<br />S
<br />I
<br />O
<br />N
<br />
<br />T
<br />O
<br />
<br />A
<br />D
<br />U
<br />MA
<br />R
<br />C
<br />O
<br />
<br />G
<br />U
<br />T
<br />I
<br />E
<br />R
<br />R
<br />E
<br />Z
<br />25
<br />2
<br />2
<br />
<br />W
<br />e
<br />s
<br />t
<br />
<br />C
<br />a
<br />m
<br />d
<br />e
<br />n
<br />
<br />P
<br />l
<br />a
<br />c
<br />e
<br />,
<br />
<br />U
<br />n
<br />i
<br />t
<br />
<br />#
<br />
<br />2
<br />Sa
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />4
<br />AD
<br />D
<br />R
<br />E
<br />S
<br />S
<br />E1.0
<br />ELECTRICAL & MECHANICAL NOTES
<br />ELECTRICAL SYMBOLS
<br />2022 RESIDENTIAL LIGHTING STANDARDS
<br />SC
<br />H
<br />E
<br />M
<br />A
<br />T
<br />I
<br />C
<br />EL
<br />E
<br />C
<br />T
<br />R
<br />I
<br />C
<br />A
<br />L
<br />PL
<br />A
<br />N
<br />SCALE: 3/8"=1'-0" 1SCHEMATIC ELECTRICAL PLAN ADU
<br />2
|