Laserfiche WebLink
FLOOR PLAN A1/4"=1'-0" <br />M <br />P <br /> <br />A <br /> <br /> <br /> <br /> <br />A <br /> <br />R <br /> <br />C <br /> <br />H <br /> <br />I <br /> <br />T <br /> <br />E <br /> <br />C <br /> <br />T <br /> <br />S <br /> <br /> <br /> <br /> <br />I <br /> <br />N <br /> <br />C <br /> <br />. <br />3578 30th Street <br />V. 619.236.0595 <br />San Diego, CA 92104 <br />MEMBER <br />www.mpa-architects.com <br />AMERICAN INSTITUTE OF ARCHITECTS <br />F. 619.236.0557 <br />CLIENT <br />PROJECT <br />DATENO. <br />REVISIONS <br />DESCRIPTION <br />AS NOTED <br />c <br />Co <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />2 <br />0 <br />2 <br />5 <br />, <br /> <br />M <br />P <br />A <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />. <br /> <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />DRAWN BY: <br />DATE: <br />JP <br />JR <br />24190 <br />PROJECT NO: <br />CHECKED BY: <br />SHEET TITLE <br />SCALE: <br />SHEET NUMBER: <br />DATABASE: <br />A <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> F <br />O <br />R <br />: <br />1-23-25 <br />24190.DWG <br />CEC BUILDERS <br />cecbuilders1@gmail.com <br />P: 303.842.6645 <br />ROBERT BARILE <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />L <br />A <br />U <br />N <br />D <br />R <br />Y <br />25 <br />0 <br />2 <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br />18723 VIA PRINCESSA, STE 321 <br />SANTA CLARITA, CA 91387 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIA <br />NHOJ <br />R UMSEY <br />C26819 <br />Exp. 3-31-2027 <br />A2.0 <br />FLOOR PLAN <br />SHEET KEYNOTES <br />GENERAL NOTES <br />EXITING NOTES <br />FIRE PROTECTION NOTES <br />1.THESE CONSTRUCTION DOCUMENTS HAVE BEEN SUBMITTED FOR REVIEW WITH THE INTENT OF <br />OBTAINING APPROVAL FOR A "COMPLETE BUILDING" INCLUDING ELECTRICAL, MECHANICAL AND <br />PLUMBING SYSTEMS. ALL EXIT FACILITIES, AND/OR ANY REQUIRED MODIFICATIONS TO ELECTRICAL, <br />MECHANICAL AND PLUMBING SYSTEMS SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE <br />APPROPRIATE GOVERNMENTAL AGENCIES PRIOR TO OCCUPANCY OF ANY INDIVIDUAL LEASE SPACE. <br />2.MAINTAIN MINIMUM 44" WIDE AISLES TO ALL EXITS EXCEPT WHERE NOTED OTHERWISE <br />3.PROVIDE OUTSIDE GAS SHUTOFF VALVE CONSPICUOUSLY MARKED. <br />4.CONTACT THE SERVING UTILITY COMPANY CUSTOMER PLANNING DEPARTMENT TO VERIFY LOCATION OF <br />ELECTRICAL AND GAS EQUIPMENT. <br />5.SEE STOREFRONT SPECIFICATION SHEET FOR SAFETY GLAZING REQUIREMENTS AT EXTERIOR DOORS <br />AND WINDOWS <br />6.WHEN WALLS AND CEILING ARE REQUIRED TO BE FIRE-RESISTIVE OR NON COMBUSTIBLE, THE FINISH <br />MATERIAL SHALL BE APPLIED DIRECTLY AGAINST SUCH FIRE-RESISTIVE OR NON-COMBUSTIBLE <br />CONSTRUCTION OR TO FURRING STRIPS NOT EXCEEDING 1 3/4". THE FURRED SPACE SHALL BE FILLED <br />WITH INORGANIC OR CLASS I MATERIAL OR FIRE STOPPED NOT TO EXCEED 8 FEET IN ANY DIRECTION <br />PER THE CURRENT EDITION OF THE C.B.C. <br />7.VENTILATION SHALL COMPLY WITH CURRENT EDITION OF THE C.B.C. <br />8.WATER HEATERS SHALL COMPLY WITH THE GOVERNING PLUMBING CODE FOR THERMAL EXPANSION <br />REQUIREMENTS. <br />9.VERIFY OR PROVIDE FIRE BLOCKS AND/OR DRAFT STOPS IN ALL EXISTING CONCEALED SPACES AS <br />REQUIRED IN THE CURRENT EDITION OF THE C.B.C. <br />10.ALL EXTERIOR DOORS SHALL BE WEATHERSTRIPPED. <br />11.DECORATIVE MATERIALS AND TRIM INSTALLED IN BUILDINGS GOVERNED BY THE SFM SHALL COMPLY <br />WITH THE PROVISIONS OF CBC 806. <br />12.THERMAL AND ACOUSTICAL INSULATION SHALL COMPLY WITH CBC 719. (CBC 803.8) <br />ACCESSIBILITY NOTES <br />1.HAND ACTIVATED DOOR OPENING HARDWARE TO BE MOUNTED 34" TO 44" ABOVE THE FLOOR AND TO BE <br />OPENABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE. <br />2.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND <br />INTERIOR DOORS, APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING <br />OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED. THE <br />MAXIMUM EFFORT TO OPERATE FIRE DOORS MAY BE INCREASED UP TO 15 POUNDS IF ALLOWED BY THE <br />APPROPRIATE ADMINISTRATIVE AUTHORITY. <br />3.ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WITH THE DOOR AT 90° TO <br />THE CLOSED POSITION. <br />4.MAXIMUM HEIGHT OF THRESHOLD TO BE 1/2". MAXIMUM VERTICAL CHANGE AT EDGE IS 1/4" WITH A <br />MAXIMUM BEVEL OF 45°. <br />5.PROVIDE A 12" EQUILATERAL TRIANGLE (VERTEX POINTING UP) ON DOOR TO MEN'S FACILITIES AND A 12" <br />DIA. CIRCLE ON DOOR TO WOMEN'S FACILITIES. THESE SYMBOLS SHOULD BE OF CONTRASTING COLOR, <br />1/4" THICK AND CENTERED ON THE DOOR 60" HIGH. <br />6.PROVIDE MINIMUM CLEARANCE OF 18" FOR INTERIOR DOORS AND 24" FOR EXTERIOR DOORS FROM THE <br />STRIKE EDGE <br />7.HANDICAP ACCESSIBILITY IS REQUIRED FOR AREA, ENTRANCE AND PATH OF TRAVEL <br />8.AT EVERY PRIMARY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN <br />ACCESSIBLE ROUTE OF TRAVEL, THERE SHALL BE A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY. SIGNS SHALL INDICATE THE DIRECTION TO ACCESSIBLE BUILDING ENTRANCES AND <br />FACILITIES AND SHALL COMPLY WITH THE REQUIREMENTS IN CURRENT EDITION OF THE C.B.C. <br />9.WHERE FIXED OR BUILT-IN TABLES, COUNTERS OR SEATS ARE PROVIDED FOR THE PUBLIC, AND IN <br />GENERAL EMPLOYEE AREAS, 5% (BUT NEVER LESS THAN ONE) MUST BE ACCESSIBLE. <br />10.THE TOPS OF TABLES AND COUNTERS SHALL BE 28" TO 34" FROM THE FLOOR. WHERE A SINGLE <br />COUNTER CONTAINS MORE THAN ONE TRANSACTION STATION SUCH AS A BANK COUNTER WITH MULTIPLE <br />TELLER WINDOW OR A RETAIL SALES COUNTER WITH MULTIPLE CASH REGISTER STATIONS, AT LEAST 5% <br />(BUT NEVER LESS THAN ONE TYPE OF EACH STATION) SHALL BE LOCATED AT A SECTION OF COUNTER <br />THAT IS AT LEAST 36" LONG AND NO MORE THAN 28" TO 34" HIGH. <br />11.PROVIDE A LEVEL FLOOR OR LANDING ON EACH SIDE OF A DOOR NOT MORE THAN 1/2" LOWER THAN THE <br />THRESHOLD OF THE DOORWAY. <br />12.LANDINGS SHALL BE PROVIDED AT ALL EXIT DOORS. LANDINGS SHALL HAVE A WIDTH OF NOT LESS THAN <br />THE WIDTH OF THE DOOR SERVED WHICHEVER IS GREATER. DOORS SWINGING OVER LANDINGS SHALL <br />NOT REDUCE THE WITH BY MORE THAN SEVEN INCHES WHEN FULLY OPEN. WHEN SERVING 50 OR MORE, <br />THE DOOR IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH TO LESS THAN ONE-HALF. <br />LANDINGS SHALL HAVE A LENGTH IN THE DIRECTION OF THE DOOR SWING OF AT LEAST 60 INCHES AND <br />THE LENGTH OPPOSITE THE DIRECTION OF THE DOOR SWING OF 48 INCHES. THE MINIMUM PUSH SIDE <br />CLEARANCE OF 12 INCHES SHALL BE PROVIDED AT THE LANDING IF THE DOOR IS EQUIPPED WITH BOTH A <br />LATCH AND A CLOSER <br />13.THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH. <br />UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT <br />CREATING A TRAP HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCH HIGH <br />SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE. <br />1.ALL INTERIOR WALL AND CEILING FINISH MATERIALS SHALL HAVE A MINIMUM CLASS III FIRE SPREAD <br />RATING AS SPECIFIED BY CURRENT EDITION OF THE C.B.C. <br />2.FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED OR AREA <br />SEPARATION WALLS. ALL REQUIRED PERMITS MUST BE OBTAINED FROM THE FIRE PREVENTION BUREAU <br />BEFORE THIS EQUIPMENT IS INSTALLED <br />3.COMPLETE PLANS AND SPECIFICATIONS FOR FIRE-EXTINGUISHER SYSTEMS, INCLUDING AUTOMATIC <br />SPRINKLERS AND WET AND DRY STANDPIPES; HALON SYSTEMS AND OTHER SPECIAL TYPES OF <br />AUTOMATIC FIRE-EXTINGUISHING SYSTEMS; BASEMENT PIPE INLETS; AND OTHER FIRE-PROTECTIONS <br />SYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FIRE AND LIFE SAFETY FOR REVIEW <br />AND APPROVAL PRIOR TO INSTALLATION (CFC 901.2) <br />4.FIRE DAMPER ASSEMBLIES, INCLUDING SLEEVES, AND INSTALLATION PROCEDURES SHALL BE APPROVED <br />BY THE BUILDING INSPECTION DEPARTMENT PRIOR TO INSTALLATION. <br />5.FOAM PLASTICS SHALL NOT BE USED AS INTERIOR FINISH EXCEPT AS PROVIDED IN CURRENT EDITION OF <br />THE C.B.C. <br />6.ALL FINISH SURFACES OF WALL & CEILING MATERIALS SHALL NOT EXCEED A FLAME SPREAD RATING OF <br />200 AND A SMOKE DENSITY RATING OF 450 CURRENT EDITION OF THE C.B.C. <br />7.CONTRACTOR TO PROVIDE SUFFICIENT 2A10BC FIRE EXTINGUISHERS SO THAT AN EXTINGUISHER CAN <br />BE REACHED WITHIN 75 FEET OF NORMAL TRAVEL FROM ANY POINT REACHED WITHIN A SUITE. <br />EXTINGUISHER LOCATIONS MAY BE DETERMINED BY FIELD INVESTIGATION. <br />8.ALL INTERIOR VENEER SHALL COMPLY WITH CURRENT EDITION OF THE C.B.C. <br />9.CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS PER LOCAL FIRE MARSHALL <br />10.ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS AND <br />WATER-FLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE ELECTRICALLY MONITORED WHERE THE <br />NUMBER OF SPRINKLERS IS 20 OR MORE. (CFC 903.4) <br />11.AUTOMATIC SPRINKLER SYSTEMS SERVING SPRINKLERS SHALL BE SUPERVISED BY AN APPROVED <br />CENTRAL, PROPRIETARY, OR REMOTE STATION SERVICE, OR A LOCAL ALARM WHICH WILL GIVE AN <br />AUDIBLE SIGNAL AT CONSTANTLY ATTENDED LOCATION <br />12.INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC, SECTION 907 <br />13.FIRE EXTINGUISHING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH CFC SECTION 903 <br />14.AN APPROVED AUDIBLE SPRINKLER FLOW ALARM (BELL) SHALL BE PROVIDED ON THE EXTERIOR OF THE <br />BUILDING IN AN APPROVED LOCATION. (CFC 903.4.2) <br />1.ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY <br />OF NOT LESS 1 FOOTCANDLE AT THE FLOOR LEVEL. <br />2.ANY ROOMS OR AREAS THAT REQUIRE MORE THAN ONE EXIT SHALL BE PROVIDED WITH EXIT SIGNS <br />CONFORMING TO CURRENT EDITION OF THE C.B.C. MAIN EXTERIOR EXIT DOORS THAT OBVIOUSLY AND <br />CLEARLY ARE IDENTIFIABLE AS EXIT DOOR NEED NOT HAVE EXIT SIGNS WHEN APPROVED BY THE <br />BUILDING OFFICIAL. <br />3.WHERE EXIT SIGNS ARE SPECIFIED, ALL SIGNAGE SHALL BE INTERNALLY ILLUMINATED WITH AN <br />INTENSITY OF NOT LESS THAN FIVE FOOTCANDLES FROM EITHER OF TWO ELECTRIC LAMPS. ALL <br />ILLUMINATED EXIT SIGNS SHALL BE PROVIDED WITH A BATTERY BACKUP. <br />4.EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS <br />TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN <br />5.EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH. <br />6.ALL DOORS AND GATES SERVING A MEANS OF EGRESS SYSTEM AND BEING USED AS A COMPONENT OF A <br />MEANS OF EGRESS SYSTEM SHALL FULLY MEET THE DOOR REQUIREMENTS OF CURRENT EDITION OF THE <br />C.B.C. <br />7.ALL EXIT DOORS SHALL OPEN IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AN OCCUPANT LOAD OF <br />GREATER THAN 50 <br />8.MAINTAIN MINIMUM 44" WIDE AISLES TO ALL EXITS UNLESS NOTED OTHERWISE <br />9.THE MAXIMUM NUMBER OF REQUIRED EXITS AND THEIR REQUIRED SEPARATION MUST BE MAINTAINED <br />UNTIL EGRESS IS PROVIDED FROM THE STRUCTURE. <br />10.PER CURRENT EDITION OF THE C.B.C. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED ON ALL EXIT <br />DOORS <br />11.DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY <br />OR ANY SPECIAL KNOWLEDGE OR EFFORT. <br />12.PROVIDE EMERGENCY LIGHTING WITH A BATTERY BACK IN ALL ROOMS OR AREAS WITH AN OCCUPANT <br />LOAD OF MORE THAN 100 OCCUPANTS. <br />13.AT EXIT SIGN LOCATIONS, TACTILE EXIT SIGNS ARE REQUIRED AT THE FOLLOWING LOCATIONS: <br />13.1.EACH GRADE-LEVEL EXTERIOR EXIT DOOR IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT" <br />13.2.EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS <br />REQUIRED TO A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS <br />"EXIT ROUTE". <br />14.THE LEVER OF LEVER ACUATED LATCHES OF LOCKS SHALL BE CURVED WITH A RETURN TO WITHIN 1/2 <br />INCH OF THE DOOR TO PREVENT CATCHING ON THE CLOTHING OF PERSONS DURING EGRESS. <br />EXISTING WALLS TO REMAIN <br />FLOOR PLAN WALL LEGEND <br />NEW SOFFIT / WALL (CEILING HUNG) <br />A <br />A5.0 <br />NEW INTERIOR METAL STUD WALL <br />3 5/8" x 25GA @ 16" O/C, U.N.O. <br />TACTILE EXIT SIGNAGE <br />EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE SIGN WITH THE WORD 'EXIT'. <br />TACTILE EXIT SIGNAGE SHALL COMPLY WITH THE FOLLOWING: <br />LETTERS ON SIGNS SHALL BE RAISED 1/32", SANS SERIF UPPERCASE CHARACTERS AND ARE <br />ACCOMPANIED BY GRADE 2 BRAILLE <br />BRAILLE DOTS SHALL 1/10" ON CENTER IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED <br />FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF THE SECOND CELL. <br />CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OR OTHER NON- GLARE FINISH <br />CHARACTERS SHALL CONTRACT WITH THEIR BACKGROUND (LIGHT CHARACTERS ON A DARK <br />BACKGROUND, OR DARK CHARACTERS ON A LIGHT BACKGROUND). <br />LETTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND HAVE A STROKE <br />WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10 <br />SIGNS SHALL BE INSTALLED ON THE LATCH SIDE OF THE DOOR. <br />SIGN MOUNTING HEIGHT SHALL BE 60" FROM FINISH FLOOR TO SIGN CENTERLINE. <br />MOUNTING LOCATION SHALL ALLOW A PERSON TO APROACH WITHIN 3" OF THE SIGNAGE WITHOUT <br />ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. <br />RAISED CHARACTERS SHALL BE BETWEEN 5/8" AND 2" HIGH <br />BRAILLE DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKROUND. <br />10. <br />9. <br />8. <br />7. <br />6. <br />5. <br />4. <br />3. <br />2. <br />1. <br />3 5/8" x 25GA @ 16" O/C, U.N.O. <br />OCCUPANT LOAD ANALYSIS <br />ROOM ROOM NAME <br />SYMBOL <br />SIZE <br />DOOR SCHEDULE <br />HARDWARE MATERIAL THICKNESS <br />DOORDOOR FRAME <br /> MATERIAL REMARK <br />A <br />DOOR A CDOOR <br />WIDTH HEIGHT <br />LOCATION <br />STOREFRONT 7'-0" <br />B <br />C <br />D <br />N/A <br />FIRE RATING <br />SEE NOTES 1, 2, 3, 5, 6, 8 <br />HARDWARE: <br />PER STOREFRONT SPECIFICATION SHEET <br />H2 <br />H1 <br />RESTROOM 3'-0"7'-0"1 3/4"TIMELY H2, H4 N/A <br />REFERENCE NOTES: <br />2- <br />1-PROVIDE DEADBOLT AT ALL EXTERIOR EXIT DOORS. ALL <br />LOCKS TO BE KEYED TO A MASTER KEY. INDIVIDUAL DOOR <br />KEYS AND MASTER KEY SHALL BE PROVIDED TO THE OWNER <br />IN DUPLICATE. FINISH TO MATCH LOCKSET. <br />DOOR HARDWARE SHALL BE OF THE LEVER OR PUSH TYPE. <br />MOUNTED 30" TO 44" ABOVE THE FLOOR AND BE OPERABLE <br />WITH A MAXIMUM EFFORT OF 5 POUNDS FOR EXTERIOR <br />DOORS AND 5 POUNDS FOR INTERIOR DOORS. <br />ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE <br />WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR <br />EFFORT. <br />3- <br />EXIT DOORS FROM GROUP A OCCUPANCIES SHALL NOT BE <br />PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC <br />HARDWARE. <br />4- <br />A FLOOR OR LANDING NOT MORE THAN 1/2" BELOW THE <br />THRESHOLD IS REQUIRED ON EACH SIDE OF ALL EXTERIOR <br />DOORS. <br />5- <br />SEE SHEET E1 FOR SPECIFIC REQUIREMENTS FOR <br />ELECTRICAL METER ROOM DOORS. VERIFY REQUIREMENTS <br />WITH LOCAL UTILITY COMPANY. <br />7- <br />A SIGN MAY BE PROVIDED AT OR NEAR THE EXIT DOOR <br />STATING "THIS DOOR TO REMAIN UNLOCKED DURING <br />BUSINESS HOURS". THIS SIGNAGE IS ONLY ALLOWED AT THE <br />MAIN EXIT. <br />6- <br />SEE NOTES 2, 8 SELF CLOSER - NORTON 8501H3 <br />PUSH/PULL KICKPLATE - H4 QH2300 3x12 PUSH S.S. <br />QH4390 3x12 PULL S.S. <br />QH 48 KICK PLATE S.S. <br />SCHLAGE S-SERIES LIGHT COMMERCIAL LOCKSETS, <br />JUPITER MODEL 613, SATIN CHROMIUM FINISH. <br />MISCELLANEOS HARDWARE (BUTTS, ETC.) TO MATCH <br />LOCKSET FINISH. <br />TYPE <br />DOOR <br />EXISTING <br />WOODSOLID CORE <br />VERIFY OR PROVIDE <br />INTERNATIONAL SYMBOL <br />OF ACCESSIBILITY PER <br />1117B.5.8, TYP. <br />10 <br />" <br />UNDERCUT <br />1" MIN. <br />DDOOR <br />H <br />A4.0 <br />INTERIOR 2'-6"7'-0"METAL 1 3/4"H2, H4 N/A SEE NOTES 2, 8. UNDER CUT 1" <br />MIN. EXITS <br />REQ'D <br />LOAD <br />FACTOR <br />OCCUPANTS EXITS <br />PROVIDED <br />ROOM <br />AREA (S.F.) <br />B <br />A5.0 <br />D <br />A5.0 <br />HOLLOW <br />METAL <br />HOLLOW <br />METAL <br />FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE COMPARABLE WITH ONE HAND AND SHALL NOT <br />REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. LEVER OPERATED, PUSH-TYPE AND <br />ELECTRONICALLY CONTROLLED MECHANISMS ARE ACCEPTABLE. SELF-CLOSING VALVES ARE ALLOWED IF THE <br />FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. SECTION 11B-606.4. <br />THE ACCESSIBLE SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34” ABOVE FINISH <br />FLOOR. KNEE CLEARANCE THAT IS AT LEAST 27” HIGH, 30” SIDE, AND 10” UNDERNEATH THE SINK SHALL BE <br />PROVIDED. HOT WATER AND DRAIN SHALL BE INSULATED OR OTHERWISE CONFIGURED SO AS TO PROTECT <br />AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE SINK. SECTION 11B-606. <br />A CLEAR FLOOR SPACE AT LEAST 30” X 48” SHALL BE PROVIDED FOR FORWARD APPROACH AND SHALL BE ON AN <br />ACCESSIBLE ROUTE. THE CLEAR SPACE SHALL EXTEND A MAXIMUM OF 19” UNDERNEATH THE SINK. SECTION <br />11B-606.2. <br />14 <br />15 <br />16 <br />FIRE PROTECTION NOTES CONTINUED <br />1.NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR <br />APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE <br />STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST IN COLOR TO THE <br />BACKGROUND. NUMBERS SHALL BE A MINIMUM OF 4” HIGH WITH A MINIUM STROKE WIDTH OF ½ INCH.” CFC <br />SECTION 505.1. <br />2.WHERE ACCESS TO OR WITHIN A STRUCTURE OR AN AREA IS RESTRICTED BECAUSE OF SECURED OPENINGS OR <br />WHERE IMMEDIATE ACCESS IS NECESSARY FOR LIFE-SAVING OR FIRE-FIGHTING PURPOSES, THE FIRE CODE <br />OFFICIAL IS AUTHORIZED TO REQUIRE A KEY BOX TO BE INSTALLED IN AN APPROVED LOCATION. THE KEY BOX <br />SHALL BE OF AN APPROVED TYPE AND SHALL CONTAIN KEY(S) TO GAIN NECESSARY ACCESS AS REQUIRED BY THE <br />FIRE CODE OFFICIAL.” CFC SECTION 503.6. <br />3.WHEN SPRINKLERS ARE REQUIRED SUBMIT FIRE SPRINKLER TENANT IMPROVEMENT PLANS TO FIRE <br />DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION.” CFC SECTION 901.4. <br />4. POTABLE FIRE EXTINGUISHER(S) SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH CFC 906, TABLE <br />906.3(1) AND CHAPTER 3, TITLE 19 CCR.” <br />5.THIS PROJECT WILL BE IN COMPLIANCE WITH THE CURRENT EDITIONS OF NFPA, CFC, TITLE 19 AND LOCAL CITY <br />OF NATIONAL CITY MUNICIPAL CODES.” <br />6.REQUESTS FOR INSPECTIONS SHALL BE MADE 48 HOURS IN ADVANCE. INSPECTIONS SHALL BE MADE ONCE <br />WORK IS COMPLETE, UTILIZING APPROVED AND STAMPED PLANS. CONTRACTOR SHALL BE REQUIRED TO HAVE <br />THE APPROVED PLANS ON SITE PER CODE.” <br />1.EXISTING STOREFRONT TO REMAIN. <br />2.VERIFY OR PROVIDE INTERNATIONAL SIGN OF ACCESSIBILITY AT PUBLIC ENTRANCE PER DETAIL <br />E/A5.0. <br />3.EXISTING 3070 STOREFRONT DOOR TO BE REMOVED AND REPLACED WITH STOREFRONT GLASS <br />4.OPENING IN WALL FOR COIN MACHINE / CARD READER <br />5.NEW ACCESSIBLE WATER CLOSET <br />6.NEW LAVATORY <br />7.NEW PLUMBING TROUGH INSIDE OF BULKHEAD. <br />8.NEW BULKHEAD MILLWORK. <br />9.NEW FOLDING TABLE / COUNTER <br />10.NEW ACCESSIBLE FOLDING TABLE. 34" MAX HEIGHT. <br />11.EXISTING ELECTRICAL PANEL, SEE ELECTRICAL PLANS. <br />12.NEW CHAIRS AND FURNITURE <br />13.NEW LAUNDRY EQUIPMENT, REFER TO EQUIPMENT PLAN. <br />17.TACTILE EXIT SIGN (SEE DETAIL D/A4.0) <br />18.NEW TANKLESS WATER HEATERS <br />19.EXISTING GAS METER <br />EXISTING 3'-0" <br />NEW <br />INTERIOR 7'-0"WOOD 1 3/4"TIMELY H2, H4 N/A SEE NOTES 2, 8SOLID CORENEW3'-0" <br />1 <br />TOTALS 31 <br />1 <br />3,289 SQ. FT. <br />2,586 100 25 1 <br /> <br />100 <br />101 260 100 2 <br />102 318 100 3 1 <br />1 <br /> <br />105 <br />63 N/A 0 1 <br />SERVICE BAY AREA <br />2 <br />2 <br />2 <br />1 <br />2 <br />LAUNDRY AREA <br />RESTROOM <br />UTIL. ROOM / SERVICE BAY AREA <br /> <br />103 62 100 1 1SECURE ROOM 2 <br />104 <br />GLAZING AT STOREFRONT DOOR IS TEMPERED8- <br />W/ 1/2" GYP. BD. EACH SIDE <br />W/ 1/2" GYP. BD. ON LAUNDRY SIDE <br />84'-2" <br />39 <br />' <br />- <br />1 <br />" <br />39 <br />' <br />- <br />1 <br />" <br />8'-0"5'-3 1/4"49'-11 1/4"11'-1 1/2"9'-10 1/4" <br />6' <br />- <br />0 <br />" <br />3' <br />- <br />4 <br />" <br />23 <br />' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />6' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />9' <br />- <br />3 <br />" <br />11 <br />' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />7' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />7' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />7' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />6'-2" <br />8'-8 3/4" <br />1 23 32 <br />4 <br />5 <br />6 <br />9 TYP. <br />813TYP. <br />9 TYP.9 TYP.9 TYP.9 TYP. <br />9 TYP. <br />9 TYP. <br />111111 <br /> <br />100 <br />LAUNDRY <br />AREA <br />2,586 SQ. FT. <br /> <br />104 <br />EXISTING RESTROOM <br />63 SQ. FT. <br /> <br />102 <br /> <br />101 <br />UTILITY ROOM/ <br />SERVICE BAY AREA <br />260 SQ. FT. <br /> <br />102 <br />SERVICE BAY AREA <br />318 SQ. FT. <br /> <br />103 <br />SECURE ROOM <br />62 SQ. FT. <br />A <br />6' <br />- <br />1 <br /> <br />3 <br />/ <br />4 <br />" <br />6'-7 1/4" <br />6' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />5'-6 1/2"5'-9"5'-10 3/4"5'-6 3/4"6'-9 3/4" <br />8' <br />- <br />8 <br /> <br />1 <br />/ <br />4 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />7' <br />- <br />5 <br />" <br />8' <br />- <br />1 <br />0 <br /> <br />1 <br />/ <br />4 <br />" <br />7 7 7 <br />7 <br />8 <br />12 <br />TYP. <br />12 <br />TYP. <br />12 <br />TYP. <br />13 <br />TYP. <br />13 <br />TYP. <br />13 <br />TYP. <br />13 <br />TYP. <br />13 <br />TYP. <br />13 <br />TYP. <br />11 <br />11 <br />9 TYP. <br />9 TYP.9 TYP. <br />A <br />A6.0 <br />B <br />NEW <br />C D <br />D <br />BDOOR <br />8 8 <br />8 <br />4 <br />4 <br />18 <br />TYP. OF 4 <br />D <br />A1.1 <br />D <br />A1.1 <br />BUILDING CORRECTIONS 5-7-25 <br />11