My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2502 W McFadden Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
2502 W McFadden Ave
>
2502 W McFadden Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:51 AM
Creation date
2/13/2026 5:00:51 AM
Metadata
Fields
Template:
Plan
Permit Number
101123291
Full Address
2502 W McFadden Ave
Street Number
2502
Street Direction
W
Street Name
McFadden
Street Suffix
Ave
Document Relationships
101123291 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\McFadden Ave\2502 W McFadden Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EC1 EC1 <br />EC1 <br />EC1 <br />CEILING PLAN A1/4"=1'-0" <br />M <br />P <br /> <br />A <br /> <br /> <br /> <br /> <br />A <br /> <br />R <br /> <br />C <br /> <br />H <br /> <br />I <br /> <br />T <br /> <br />E <br /> <br />C <br /> <br />T <br /> <br />S <br /> <br /> <br /> <br /> <br />I <br /> <br />N <br /> <br />C <br /> <br />. <br />3578 30th Street <br />V. 619.236.0595 <br />San Diego, CA 92104 <br />MEMBER <br />www.mpa-architects.com <br />AMERICAN INSTITUTE OF ARCHITECTS <br />F. 619.236.0557 <br />CLIENT <br />PROJECT <br />DATENO. <br />REVISIONS <br />DESCRIPTION <br />AS NOTED <br />c <br />Co <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />2 <br />0 <br />2 <br />5 <br />, <br /> <br />M <br />P <br />A <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />. <br /> <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />DRAWN BY: <br />DATE: <br />JP <br />JR <br />24190 <br />PROJECT NO: <br />CHECKED BY: <br />SHEET TITLE <br />SCALE: <br />SHEET NUMBER: <br />DATABASE: <br />A <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> F <br />O <br />R <br />: <br />1-23-25 <br />24190.DWG <br />CEC BUILDERS <br />cecbuilders1@gmail.com <br />P: 303.842.6645 <br />ROBERT BARILE <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />L <br />A <br />U <br />N <br />D <br />R <br />Y <br />25 <br />0 <br />2 <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br />18723 VIA PRINCESSA, STE 321 <br />SANTA CLARITA, CA 91387 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIA <br />NHOJ <br />R UMSEY <br />C26819 <br />Exp. 3-31-2027 <br />A2.1 <br /> CEILING PLAN <br />(E) GYP. BD. CLG. <br />@ 8'-0" A.F.F. <br />OPEN TO <br />STRUCTURE ABOVE <br />(E) GYP. BD. CLG. <br />@ 8'-0" A.F.F. <br />OPEN TO <br />STRUCTURE ABOVE <br />EXIT LIGHT w/ EMERGENCY <br />BATTERY PACKEXITD <br />FIXTURE SCHEDULE <br />SYMBOL NOTATION MANUF. & CATALOG NO.DESCRIPTION LAMP <br />RESTROOM EXHAUST FANE <br />LETTERS TO BE GREEN IN <br />COLOR <br />B <br />INCLUDED RECESSED TYPE W / EDGE - <br />LIT CLEAR ACRYLIC BLADE <br />OR EQUAL <br />BROAN MODEL NO. S13060W (TOTAL) <br />C <br />44W <br />LED <br />FSG <br />CAT# FSG-TF24352' x 2' LED LAY-IN <br />A <br />STRIP LIGHT <br />4' - LED TRADITIONAL LINEAR SUPERIOR LIGHTING <br />25W (TOTAL)S18057 <br />6201V-4FT-50W-40K-D <br />GLOBALUX 2'x4' RECESSED <br />LED <br />40 W (TOTAL)LCB-24-40-MVD-840 <br /> (OR APPROVED EQUAL) <br />6.2 CEILING AREAS OVER 2500 SQ.FT. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL <br />HEIGHT PARTITIONS THAT BREAK THE CEILING INTO AREAS NOT EXCEEDING 2500 SQ.FT. <br />6.1 ALL CEILINGS SHALL USE A HEAVY DUTY T-BAR GRID SYSTEM <br />6.SUSPENDED ACOUSTICAL CEILING SYSTEM IN SEISMIC DESIGN CATEGORY D, E OR F SHALL <br />COMPLY WITH ASCE 7-05, SECTION 13.5.6.2.1 AS FOLLOWS: <br />12.SUSPENDED ACOUSTICAL CEILINGS SHALL COMPLY WITH SECTION WITH CBC SECTION 808.1 AND 808.1.1.1 <br />AND MEET BOTH FLAME SPREAD AND SMOKE DEVELOPED RATINGS <br />12'-0" <br />MAX. <br />6'-0" <br />MAX. <br />6' <br />- <br />0 <br />" <br />MA <br />X <br />. <br />8" <br />6'-0" <br />MAX. <br />12'-0" <br />MAX. <br />11.IF PARTITIONS ARE ATTACHED TO THE SUSPENDING SYSTEM THEY MUST BE LATERALLY BRACED TO THE <br />BUILDING STRUCTURE. <br />10.CEILINGS WITHOUT RIGID BRACING MUST HAVE 2 INCHES OVERSIZED TRIM RINGS FOR SPRINKLERS AND <br />OTHER PENETRATIONS. <br />9.RIGID BRACING MAY BE USED INSTEAD OF DIAGONAL SPLAY WIRES. RIGID BRACING MUST LIMIT CEILING <br />MOVEMENT TO LESS THAN 1/4" AT THE POINT OF ATTACHMENT. <br />MAX. <br />8"4'-0" <br />MAX. <br />2.WHITE #769-A CORTEGA CEILING TILE BY ARMSTRONG, OR EQUAL, U.N.O. <br />24" x 48" DONN DX SUSPENDED CEILING SYSTEM BY USG CORP., OR EQUAL. ICC #ESR-12221. <br />SUSPENDED CEILING SPECS: <br />1.SUSPENDED ACOUSTICAL CEILING SYSTEM IN SEISMIC DESIGN CATEGORY D, E OR F SHALL BE INSTALLED <br />IN ACCORDANCE WITH THE REQUIREMENTS OF ASCE 7-10, CHAPTER 13 AND CBC SECTION 803.9 <br />3.TERMINALS OR SERVICES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY <br />FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. <br />2.TERMINALS OR SERVICES WEIGHTING 20 POUNDS, BUT NOT MORE THAN 56 POUNDS, IN <br />ADDITION TO THE ABOVE, SHALL HAVE TWO No. 12 GA. HANGERS CONNECTED FROM THE <br />TERMINAL OR SERVICE TO THE CEILING SYSTEM HANGERS OR TO THE STRUCTURE ABOVE. <br />MECHANICAL: <br />1.CEILING-MOUNTED AIR TERMINALS OR SERVICES WEIGHTING LESS THAN 20 POUNDS SHALL BE <br />POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS RUNNERS <br />WITH THE SAME CARRYING CAPACITY AS THE MAIN RUNNERS. <br />1. <br />LIGHTING FIXTURES: <br />2. <br />3. <br />4. <br />ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. <br />THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100 % OF THE LIGHTING FIXTURE <br />WEIGHT ACTING IN ANY DIRECTION. NO. 12 GAGE HANGERS SHALL BE ATTACHED TO THE GRID <br />MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES MAY UTILIZE <br />COMMON WIRES. <br />PENDANT-HUNG LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE <br />ABOVE USING NO. 9 GAGE WIRE OR APPROVED ALTERNATE SUPPORT WITHOUT USING THE <br />CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. <br />LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM <br />THE STRUCTURE ABOVE BY APPROVED HANGERS. <br />LIGHTING FIXTURE WEIGHING LESS THAN 56 POUNDS SHALL HAVE, IN ADDITION TO THE <br />REQUIREMENTS OUTLINED ABOVE, TWO NO. 12 GAGE HANGERS CONNECTED FROM THE <br />FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. <br />1. <br />4. <br />3. <br />5. <br />2. <br />STRUCTURAL NOTES: <br />VERTICAL HANGERS: SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAGE SPACED <br />AT 4'-0" ON CENTER OR NO. 10 GAGE AT 5'-0" ON CENTER ALONG EACH MAIN RUNNER UNLESS <br />CALCULATIONS JUSTIFYING THE INCREASED SPACING ARE PROVIDED. EACH VERTICAL WIRE <br />SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE SUPPORT ABOVE <br />WITH A MINIMUM OF THREE TURNS. ANY CONNECTION DEVICE AT THE SUPPORTING <br />CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. SUSPENSION <br />WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT OF PLUMB UNLESS COUNTER SLOPING WIRES <br />ARE PROVIDED. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR <br />EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS <br />PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE A MINIMUM OF BACK TO <br />BACK 1 1-1/4" COLD - ROLLED CHANNELS FOR SPANS EXCEEDING 48". <br />LATERAL FORCE BRACING: HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 <br />GAGE WIRES SECURED TO THE MAIN RUNNER WITHIN TWO INCHES OF THE CROSS RUNNER <br />INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING <br />45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT FASTEN TO THE MAIN RUNNER SHALL <br />BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR <br />FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT <br />INDUCTED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE <br />PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 4'-0" FROM <br />EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE SHALL BE <br />ADEQUATE FOR THE LOAD IMPOSED. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A <br />MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED <br />WITH BRACING RESTRAINS FOR HORIZONTAL FORCE. BRACING WIRES SHALL BE ATTACHED TO <br />THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN <br />LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WHICHEVER IS <br />GREATER, WITH A SAFETY FACTOR OF 2. <br />PERIMETER MEMBERS: UNLESS PERIMETER MEMBERS ARE A STRUCTURAL PART OF THE <br />APPROVED SYSTEM, WALL ANGLES OR CHANNELS SHALL BE CONSIDERED AS AESTHETIC <br />CLOSURES AND WITH NO STRUCTURAL VALUE. FOR TILE CEILINGS, ENDS OF MAIN RUNNERS <br />AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT THEIR SPREADING. <br />MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER MEMBER AT <br />TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED <br />AT THE TWO OTHER WALLS. <br />PERIMETER HANGERS: THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER <br />SHALL BE SUPPORTED INDEPENDENTLY A MAXIMUM OF 8" FROM EACH WALL OR CEILING <br />DISCONTINUITY WITH NO. 12 GAGE WIRE OR APPROVED WALL SUPPORT. <br />1. <br />1. <br />3. <br />2. <br />4. <br />3. <br />6. <br />7. <br />8. <br />5. <br />4. <br />2. <br />c. <br />b. <br />d. <br />a. <br />INSTALLATION OF COMPONENTS: <br />GENERAL STATEMENT: <br />WHERE THE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE <br />PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING <br />METHOD SHALL BE USED. <br />INTERSECTING WEBS AND FLANGES OF STRUCTURAL MEMBERS SHALL FORM ANGLES BETWEEN <br />THEM OF 90 DEGREES +/- 2 DEGREES. <br />CARRYING CHANNELS AND MAIN RUNNERS SHALL BE INSTALLED SO THAT THEY ARE ALL LEVEL <br />TO WITHIN 1/8 INCH IN 12 FEET. LOCAL KINKS OR BENDS SHALL NOT BE MADE IN HANGER WIRES <br />AS A MEANS OF LEVELING CARRYING CHANNELS. <br />CROSS RUNNERS SHALL BE SUPPORTED BY EITHER MAIN RUNNERS OR BY OTHER CROSS <br />RUNNERS NOT WITHIN 1/32 INCH OF THE REQUIRED CENTER DISTANCES. <br />WIRE HANGERS FOR SUSPENDING CARRYING CHANNELS OR MAIN RUNNERS FROM AN EXISTING <br />STRUCTURE SHALL BE A MINIMUM OF NO. 12 GAGE, GALVANIZED, SOFT ANNEALED, MILD STEEL <br />WIRE. EACH ATTACHMENT SHALL BE WITH A MINIMUM OF THREE TURNS IN 3 INCHES. <br />GENERAL NOTES: <br />SECURE WIRES TO STRUCTURE ABOVE WITH #10 (.190) THREADED SCREW OR EQUIVALENT SCREW EYE <br />AT SOLID MEMBERS. <br />CABLE TRAYS, ELECTRICAL CONDUITS AND PIPING SHALL BE INDEPENDENTLY SUPPORTED AND <br />INDEPENDENTLY BRACED FROM THE STRUCTURE. <br />POSITIVE BRACING TO THE STRUCTURE SHALL BE PROVIDED AT CHANGES IN THE CEILING PLANE <br />ELEVATION OR AT DISCONTINUITIES IN THE CEILING GRID SYSTEM. <br />THE SUSPENDED CELINGS AND LIGHTING SYSTEMS SHALL BE LIMITED TO 6 FEET BELOW THE STRUCTURAL <br />DECK UNLESS THE LATERAL BRACING IS DESIGNED BY A LICENSED ENGINEER OR ARCHITECT. <br />SUSPENDED CEILING ASSEMBLIES LOCATED ALONG MEANS OF EGRESS SERVING AN OCCUPANT LOAD OF <br />30 OR MORE WHERE THE VERTICAL DISTANCE BETWEEN THE CEILING AND THE STRUCTURAL DECK SHALL <br />COMPLY WITH THE FOLLOWING PROVISIONS: <br />PERIMITER MEMBERS: A MINIMUM WALL ANGLE SIZE OF AT LEAST A TWO INCH HORIZONTAL LEG SHALL BE <br />USED AT PERIMETER WALLS AND INTERIOR FULL HEIGHT PARTITIONS. THE FIRST CEILING TILE SHALL <br />MAINTAIN 3/4" CLEAR FROM THE FINISH WALL SURFACE. AN EQUIVALENT ALTERNATIVE DETAIL THAT WILL <br />PROVIDE SUFFICIENT MOVEMENT DUE TO ANTICIPATED LATERAL BUILDING DISPLACEMENT MAY BE USED <br />IN LIEU OF THE LONG LEG ANGLE SUBJECT TO THE APPROVAL OF THE SUPERINTENDENT OF BUILDING. <br />ALL LAY-IN PANELS SHALL BE SECURED TO THE SUSPENSION CEILING ASSEMBLY WITH TWO HOLD <br />DOWN CLIPS MINIMUM FOR EACH TILE WITHIN A 4-FOOT RADIUS OF THE EXIT LIGHTS AND EXIT SIGNS. <br />INDEPENDENT SUPPORTS AND BRACES SHALL BE PROVIDED FOR LIGHT FIXTURES REQUIRED FOR <br />EXIT ILLUMINATION. POWER SUPPLY FOR EXIT ILLUMINATION SHALL COMPLY WITH THE <br />REQUIREMENTS OF CBC SECTION 1006.3. <br />SEPARATE SUPPORT FROM THE STRUCTURAL DECK SHALL BE PROVIDED FOR ALL APPENDAGES <br />SUCH AS LIGHT FIXTURES, AIR DIFFUSERS, EXIT SIGNS, AND SIMILAR ELEMENTS. <br />CEILING SUSPENSION SYSTEMS SHALL BE CONNECTED AND BRACED WITH VERTICAL HANGERS <br />ATTACHED DIRECTLY TO THE STRUCTURAL DECK ALONG THE MEANS OF EGRESS SERVING AN <br />OCCUPANT LOAD OF 30 OR MORE AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. <br />SPACING OF VERTICAL HANGERS SHALL NOT EXCEED 2 FEET ON CENTER ALONG THE ENTIRE LENGTH <br />OF THE SUSPENDED CEILING ASSEMBLY LOCATED ALONG THE MEANS OF EGRESS OR AT THE LOBBY. <br />SPRINKLER HEADS (DROPS) EXCEPT FIRE-RESISTANCE-RATED FLOOR/CEILING OR ROOF/CEILING <br />ASSEMBLIES, SHALL BE DESIGNED TO ALLOW FOR FREE MOVEMENT OF THE SPRINKLER PIPES WITH <br />OVERSIZE RINGS, SLEEVES OR ADAPTORS THROUGH THE CEILING TILE, IN ACCORDANCE WITH SECTION <br />13.5.6.2.2(e) OF ASCE 7. SPRINKLER HEADS PENETRATING FIRE-RESISTANCE-RATED FLOOR/CEILING OR <br />ROOF/CEILING ASSEMBLIES SHALL COMPLY WITH CBC SECTION 712. <br />CROSS TEE CONNECTION <br />HOLD DOWN CLIP <br />WALL ANGLE SUPPORT <br />FASTENED TO GRID <br />FASTENER <br />SEISMIC ELEVATION CHANGE BRACING <br />CHANNEL MOLDING <br />FASTENER <br />TRACK OR ALTERNATE <br />COVER <br />2" <br />SEISMIC SEPARATION JOINT <br />PERIMETER STARTER WALLS <br />12 GA. VERTICAL <br />HIRE HANGER <br />MAIN TEE (RESTRAINED) <br />STABILIZER BAR <br />MIN. <br />3/4" <br />2" <br />MIN. <br />ACOUSTIC CEILING TILE <br />METAL CLIP ANGLE w/ <br />2-POP RIVETS EACH LEG <br />8" <br />MAX. <br />CROSS TEE (RESTRAINED) <br />STABILIZER BAR <br />METAL CLIP ANGLE w/ <br />2-POP RIVETS EACH LEG <br />8" <br />MAX. <br />2" <br />MIN. <br />MIN. <br />3/4" <br />RUNNER TEES <br />COMPRESSION <br />STRUT <br />ELEVATION <br />MAX. <br />8" <br />MAX. <br />OPPOSITE WALLS <br />45°45° <br />ACOUSTIC CEILING TILE <br />2"MAX. <br />CROSS "T" 24" O.C. <br />MAIN "T" 48" O.C. <br />LIGHT ZINC-COAT FINISH <br />DOUBLE 18 GA. OR 9 GA. <br />STEEL HANGER WIRES AT <br />4"-0" O.C. EACH WAY SECURE <br />TO STRUCTURE FROM ABOVE <br />GRID PERIMETER RIVETED <br />STABILIZER BAR <br />COMPRESSION STRUT <br />NO. 12 GA. WIRE HANGERS <br />AT 4'-0" O.C. EACH WAY. <br />12'-0" <br />MAX. <br />6'-0" <br />MAX. <br />MA <br />X <br />. <br />4' <br />- <br />0 <br />" <br />MA <br />X <br />. <br />6' <br />- <br />0 <br />" <br />MA <br />X <br />. <br />12 <br />' <br />- <br />0 <br />" <br />MA <br />X <br />. <br />8" <br />FI <br />N <br />I <br />S <br />H <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />PE <br />R <br /> <br />P <br />L <br />A <br />N <br />S <br />ROOF AS OCCURS 4 NO. 12 WIRES SPLAYED 45° <br />IN FOUR DIRECTIONS 90 <br />DEGREES APART <br />NO. 12 GA. WIRE <br />HANGERS AT 4'-0" <br />O.C. EACH WAY <br />FIRST WIRE <br />6'-0" <br />MAX. <br />FLOOR AS OCCURS. <br />CLEAR <br />12'-0" <br />MAX. <br />ATTIC AS OCCURS 3/4" MIN. <br />NO SCALE <br />SUSPENDED CEILING SYSTEM, DETAILS AND SPECIFICATIONS <br />SEISMIC PLAN <br />IMPORTANT NOTE: <br />NO SPLAY WIRES OR <br />COMPRESSION STRUTS <br />ARE REQUIRED FOR <br />ACCOUSTIC CEILINGS <br />LESS THAN 1,000 SQUARE <br />FEET IN AREA PER <br />A.S.T.M. E 580/E 580M-90a <br />SECTION 5.2.8.1 <br />B <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />C <br />C <br />B <br />B <br />BBBBBBB <br />B <br />B <br />EXIT D <br />(N) SUSPENDED <br />CLG. <br />@ 10'-0" A.F.F. <br />B <br />A2.1
The URL can be used to link to this page
Your browser does not support the video tag.