Laserfiche WebLink
RIDGE <br />4:12 <br />4:12 <br />4:12 <br />4:12 <br />1' <br />- <br />0 <br />" <br /> <br />T <br />Y <br />P <br />. <br />3' <br />- <br />6 <br />" <br />3' <br />- <br />6 <br />" <br />T.O. RIDGE (V.I.F.) <br />T.O.PLATE (V.I.F.) <br />T.O.F.F. (V.I.F.) <br />9' <br />- <br />1 <br />" <br />13 <br />' <br />- <br />1 <br />1 <br />" <br />8" <br />F.G. <br />T.O.PLATE (V.I.F.) <br />T.O.F.F. (V.I.F.) <br />9' <br />- <br />1 <br />" <br />8" <br />F.G. <br />ATTIC <br />BATHROOM #2LIVING / KITCHEN <br />8" <br />± <br />1 <br />3 <br />' <br />- <br />1 <br />1 <br />" <br />T.O.F.F (V.I.F.) <br />F.G. <br />T.O.RIDGE (V.I.F.) <br />9' <br />- <br />5 <br />" <br />8" <br />± <br />1 <br />3 <br />' <br />- <br />1 <br />1 <br />" <br />T.O.F.F (V.I.F.) <br />F.G. <br />T.O.RIDGE (V.I.F.) <br />T.O.ROOF (V.I.F.) <br />7' <br />- <br />0 <br />" <br />HEADER (V.I.F.) <br />KITCHEN LIVING <br />A-2.0 <br />ADU ROOF PLAN AND <br />SECTIONS <br />1 <br />A-2.0 <br />1 <br />A-2.0 <br />2 <br />A-2.0 <br />2 <br />A-2.0 <br />ST <br />E <br />V <br />E <br />N <br /> <br />C <br />A <br />R <br />O <br />2120 W. Dahl Ln. <br />Santa Ana, 92704 <br />21 <br />2 <br />0 <br /> <br />W <br />. <br /> <br />D <br />a <br />h <br />l <br /> <br />L <br />n <br />. <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />NEW ADU <br />705 S.F. <br />3905 S. ROSS ST. #B <br />SANTA ANA CA. 92707 <br />TEL. 714.585.0546 <br />HL QUALITY PLANS <br />hlqualityplans@gmail.com <br />APN: 109-444-11 <br />ATTIC VENTILATION NOTES <br />ROOF PLAN NOTES VENTILATION SCHEDULE: <br />TIMBER LINE ASPHALT SHINGLES MIN. CLASS "A" ICC ESR #1475 #790. <br />ROOF AREA <br />SECTION KEYNOTES <br />01 <br />RIDGE, PER STRUCTURAL PLANS.02 <br />03 <br />04 <br />06 <br />07 <br />05 <br />08 <br />2X CEILING JOIST, PER STRUCTURAL PLANS. <br />CONCRETE FOOTING, PER STRUCTURAL PLANS. <br />2X WALL FRAME STUD AT 16" O.C., PER STRUCTURAL PLANS. <br />PLYWOOD OVER ROOF RAFTERS, PER STRUCTURAL PLANS. <br />09 <br />10 <br />11 <br />12 <br />13 <br />ATTIC INSULATION R-30, PER TITLE -24. <br />14 <br />WALL INSULATION R-15, PER TITLE -24. <br />WOOD BEAM / HEADER, PER STRUCTURAL PLANS <br />2X ROOF RAFTERS, PER STRUCTURAL PLANS. <br />CONCRETE SLAB, PER STRUCTURAL PLANS. <br />15 <br />16 <br />PORTICO ROOF FRAME ABOVE DOOR <br />CONCRETE LANDING, PER STRUCTURAL PLANS. <br />LEGEND <br />(E) = DENOTES EXISTING <br />(N) = DENOTES NEW <br />(R) = DENOTES RELOCATE <br />LINE OF BUILDING WALL.01 <br /># <br />02 <br />ROOF KEYNOTES <br />LINE OF BUILDING ROOF. <br />03 <br />04 ROOF DORMER VENT, SEE VENT CALCS. <br />05 <br />06 <br />(E) NATURAL GRADE. <br />NEW ROOF PLAN SCALE: 1/4" = 1'-0" <br />TRUE NORTH <br />BUILDING SECTION 1 SCALE: 1/4" = 1'-0" <br />NEW ROOF <br />NEW ROOF ROOFING ASPHALT SHINGLES, <br />MIN. CLASS "B" ICC ESR #1475 #790 <br />0102 <br />02 <br />03 <br />01 <br />02 <br />01 <br />0102 03 <br />04 <br />BUILDING SECTION 2 SCALE: 1/4" = 1'-0" <br />020103 <br />0410 <br />05 <br />09 <br />06 <br />07 07 <br />08 08 <br />KNEE BRACE SUPPORT AT PORTICO ROOF ABOVE DOOR. <br />PROVIDE TIGHT FASCIA AT EASEMENT BUILDING SIDE <br />DOOR AS OCCURS, PER PLAN <br />14 <br />08 <br />NOT PROJECTIONS ROOF AT EASEMENT BUILDING SIDE <br />INSTALL PORTICO ROOF ABOVE DOOR <br />03 <br />06 <br />06 <br />05 <br />1616 <br />07 16110711 <br />06 <br />05 <br />09 <br />08 <br />15 <br />15 <br />020103 <br />13 <br />1214 <br />2 <br />AD-1 <br />TYP. <br />04 <br />1 <br />1