My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2100 S Fairview St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairview St
>
2100 S Fairview St
>
2100 S Fairview St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:15 AM
Creation date
2/13/2026 5:01:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20184701
101121913
Full Address
2100 S Fairview St
Street Number
2100
Street Direction
S
Street Name
Fairview
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Client - SCE Charge Ready Date - <br />Project -Brixen EVCS Made By - <br />Location -2100 S Fairview ST, Santa Ana, CA 92704 Orange County. Checked By - <br />Proj. No. -Preliminary -1650605 <br />9/18/2024 <br />DSS <br />- <br />80% Review <br />Description -Design calculations for footing pad of switchboard, Transformer, Distribution <br />Panel, EV Charger & Gateway Final - 100% Review <br />1.1 Scope of work <br />This document covers load development and design calculation of concrete mat foundations to support Switchboard Panel, Transformer, Distribution <br />Panel, EV Charger & Gateway. <br />1.2 Reference Documents <br />CRP1650605 Brixen High Level Concept Plan REDLINE 8/9/2022 <br />1.2.1 Codes & References <br />Minimum Design Loads for Buildings and Other Structures ASCE/SEI 7 - 2016 <br />Building code requirements for structural concrete ACI318-19 <br />California Building Standards Code CBSC 2022 <br />1.2.2 Equipment Data <br />Title Date <br />Switchgear Equipments - <br />HC_JNT-EVC10-Hypercharge Charger - <br />6-Foot Pedestal Cut Sheet - <br />1.3 Material Specification <br />Characteristic compressive strength of concrete f'c = 2500 psi <br />Characteristic strength of reinforcement fy =60000 psi <br />Modulus of elasticity of concrete Ec = 2850.00 ksi <br />Modulus of elasticity of Steel Es = 29000.00 ksi <br />1.4 Basis of Design and Philosophy <br />1 No snow load is considered in the design as per ATC Hazard by location website. <br />2 Wind Exposure category is considered as C. <br />3 Allowable Bearing Capacity is considered to be 1500 psf. <br />4 Overstrength factor of 2.0 is considered for anchor bolt design. <br />5 Reduction in footing size due to conduit openings are neglected for foundation design and calculation of subgrade modulus. <br />6 Bottom cover to foundation is considered as 3" and top cover as 2". <br />7 Live Load of 60 psf over the Slab is considered in Risa Foundation as per Table 4.3-1 ASCE 7-16 for Elevated Platforms. <br />8 Subgrade Modulus is considered as 125 pci in absence of accurate data. <br />9 Characteristic compressive strength of the concrete is considered as 2500 psf conservatively. <br />10 Frost depth of the soil is neglected. <br />11 Pesudo dynamic forces as per ACI 351.3R-18 section 4.2.4 are not considered as the equipments are not heavy loaded. <br />12 Coefficient of friction is considered as 0.25 in absence of accurate data. <br />13 In absence of design basis, the seismic and the wind parameters are considered as per the "ATC Hazard by location" website. Reference <br />provided in subsequent pages. <br />14 In absence of weight of charger & pedestal in vendor cutsheets, the weight of charger & pedestal is assumed to be 40 lbs. <br />15 In absence of anchorage detail for chargers, the achor details are assumed as per "CPF50-anchorage details.pdf". Refer Annexure. <br />16 Chargepoint Gateway is considered to be supported on H-Frame. Similar structure is modelled in RISA 3D for footing, anchor and base plate design.
The URL can be used to link to this page
Your browser does not support the video tag.