My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 W Hemlock Way & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hemlock Way
>
2014 W Hemlock Way Unit# 2
>
2014 W Hemlock Way & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:58 AM
Creation date
2/13/2026 5:01:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101121890
Full Address
2014 W Hemlock Way Unit# 2
Street Number
2014
Street Direction
W
Street Name
Hemlock
Street Suffix
Way
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 5 <br /> <br />Potential Consequences of Liquefaction or Secondary Liquefaction Included Hazards <br /> <br />Potential consequences of liquefaction or secondary liquefaction included hazards <br />generally consist of differential settlement (vertical deformations), lateral <br />movement/lateral spreading (horizontal deformations), oscillation, and reduction in <br />foundation soil-bearing capacity (bearing failure). <br /> <br />A sloping condition or drainage or stream channel does not exist at the site; therefore, <br />lateral movement/lateral spreading, oscillation, etc. due to potential liquefaction are not <br />anticipated to be credible hazards for the proposed new structure. <br /> <br />We believe if the area would be “liquefied” in the future due to a very strong earthquake, <br />the potential damage to the proposed new structures which will be properly structurally <br />designed in accordance with the new up-to-date codes would be much less severe than <br />the existing on-site structures and surrounding existing houses which have been <br />previously structurally designed based on old codes (which are much less stringent than <br />the current new codes). However, the owner(s) of this property should be aware of the <br />potential damage to the new structures due to liquefaction. <br /> <br />In summary, it should be recognized that structural mitigation may not reduce the <br />potential of the soils to liquefy during an earthquake; and there will remain some risk that <br />the new structures could still suffer damage if liquefaction occurs, during a very strong <br />earthquake. <br /> <br />For conservative purposes, a strengthened / stiffened foundation system as <br />recommended in this report should be used for support of the proposed structure. <br /> <br />Slope Stability <br /> <br />The site is a flat area; therefore, slope instability is not a concern for the proposed <br />development. <br /> <br />CONCLUSIONS AND RECOMMENDATIONS <br /> <br />General Conclusions <br /> <br />Construction of the proposed structure at the subject site is considered geotechnically <br />feasible, provided the recommendations outlined in this report are implemented. <br /> <br />Note: The conclusions and recommendations of this report are based on information as <br />interpreted from our limited subsurface investigation. It is not anticipated but they should <br />be revised accordingly if geotechnical conditions to be exposed during site preparation/ <br />grading and construction significantly differ from our findings and interpretations. <br /> <br />In general, a conventional shallow foundation can be used for support of the proposed <br />structure.
The URL can be used to link to this page
Your browser does not support the video tag.