My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 E Dyer Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
1700 E Dyer Rd
>
1700 E Dyer Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:16 AM
Creation date
2/13/2026 5:01:11 AM
Metadata
Fields
Template:
Plan
Permit Number
20186841
101124762
Full Address
1700 E Dyer Rd
Street Number
1700
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
Document Relationships
101124762 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\1700 E Dyer Rd
20186841 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\1700 E Dyer Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2 <br />3 <br />5 <br />E07 <br />E06 <br />E14 <br />E11 <br />A <br />B <br />MDP <br />E01 <br />E02 <br />E03 <br />A <br />39,41 <br />A <br />7,9 <br />A <br />22,24 <br />E12 <br />E20 <br />6 <br />7 <br />A <br />27,29 <br />A <br />17,19 <br />(3 <br />0 <br />/ <br />3 <br />P <br />) <br />(30/2P) <br />(30/2P) <br />A <br />35 <br />3 <br />C <br />4E14 <br />(30/2P) <br />1 <br />G L S <br />8 <br />8 <br />8 <br />8 <br />E01 <br />A <br />28,30 <br />(30/2P) <br />#10 <br />#10 <br />#10 A <br />25 <br />#10 1 <br />RISER DIAGRAM KEYED NOTES: <br />EXISTING 800A, 120/208V, 3PH, 4W METERING SWITCHBOARD. <br />EXISTING PANELBOARD. <br />EXISTING FEEDER <br />1 <br />2 <br />3 <br />M <br />PANEL <br />G <br />225A MLO <br />120/208V <br />3∅, 4W <br />(EXISTING) <br />2 <br />1 <br />EXTERIORINTERIOR <br />FLOOR LINE <br />ROOF <br />3 <br />PANEL <br />L <br />225A MLO <br />120/208V <br />3∅, 4W <br />(EXISTING) <br />2 <br />PANEL <br />A <br />225A MLO <br />120/208V <br />3∅, 4W <br />(EXISTING) <br />2 <br />PANEL <br />S <br />225A MLO <br />120/208V <br />3∅, 4W <br />(EXISTING) <br />2 <br />PANEL <br />B <br />225A MLO <br />120/208V <br />3∅, 4W <br />(EXISTING) <br />2 <br />PANEL <br />C <br />225A MLO <br />120/208V <br />3∅, 4W <br />(EXISTING) <br />2 <br />333333 <br />4 <br />EXISTING WIREWAY4 <br />KEYNOTES <br />1 EXISTING SODA DISPENSER TO BE RELOCATED TO THIS LOCATION. EC TO ROUTE EXISTING CIRCUIT TO <br />NEW EQUIPMENT LOCATION. <br />2 EXISTING COFFEE DISPENSER TO BE RELOCATED TO THIS LOCATION. EC TO ROUTE EXISTING CIRCUIT TO <br />NEW EQUIPMENT LOCATION. <br />3 EXISTING ROLLER GRILL TO BE RELOCATED TO THIS LOCATION. EC TO ROUTE EXISTING CIRCUIT TO NEW <br />EQUIPMENT LOCATION. <br />4 NEW HOT FOOD DISPLAY CASE. RE-USE CIRCUIT FROM REMOVED DISPLAY CASE. <br />5 EXISTING MICROWAVE TO BE RELOCATED TO THIS LOCATION. EC TO ROUTE EXISTING CIRCUIT TO NEW <br />EQUIPMENT LOCATION. <br />6 PROVIDE RECEPTACLE FOR FLAVOR STATION. CONNECT TO NEARBY SODA DISPENSER CIRCUIT. <br />7 PROVIDE RECEPTACLE FOR COFFEE WARMER. CONNECT TO NEARBY COFFEE DISPENSER CIRCUIT. <br />8 CONNECT SIGN TO EXISTING LIGHTING CIRCUIT AND CONTROLS SERVING AREA. <br />ELECTRICAL REMODEL NOTES <br />A BRANCH CIRCUITING INDICATED ON PLANS AND SCHEDULES IS BASED UPON EXISTING <br />PLANS AND SITE OBSERVATION, CONTRACTOR TO FIELD VERIFY. <br />B PROVIDE TYPED CIRCUIT BOARD DIRECTORIES TO REFLECT AS-CONSTRUCTED <br />CONDITIONS. FIELD VERIFY DURING CONSTRUCTION AND REVISE ACCORDINGLY. <br />C PROVIDE NECESSARY DEMOLITION TO FACILITATE NEW CONSTRUCTION WORK <br />ASSOCIATED WITH THIS PROJECT. COORDINATE OUTAGES WITH OWNER MINIMUM 72 <br />HOURS IN ADVANCE. OWNER RETAINS RIGHT TO FIRST SALVAGE. PROVIDE DISPOSAL <br />OF REMOVED MATERIAL. MAINTAIN CIRCUIT CONTINUITY AS REQUIRED. <br />D IT IS THE INTENT OF THESE DIAGRAMMATIC DRAWINGS TO PROVIDE THE PROJECT <br />SCOPE INCLUDING, BUT NOT LIMITED TO PHASED DEMOLITION AND NEW <br />CONSTRUCTION. EXISTING INFORMATION INDICATED ON THESE PLANS DOES NOT <br />REPRESENT ALL EXISTING CONDITIONS. THIS CONTRACTOR SHALL BECOME FAMILIAR <br />WITH EXISTING CONDITIONS, SCOPE OF PHASING, AND PROJECT INTENT PRIOR TO BID <br />SUBMISSION. NO EXTRA WILL BE ALLOWED DUE TO THE LACK OF KNOWLEDGE OF <br />EXISTING CONDITIONS TO COORDINATE RELOCATION OF ELECTRICAL SYSTEMS AS <br />REQUIRED. <br />E PROVIDE CUTTING, PATCHING, AND RESTORATION OF FINISHES NECESSARY FOR <br />WORK SURFACES DAMAGED BY THIS WORK AND SPACES AROUND CONDUITS <br />PASSING THROUGH FLOORS AND WALLS SHALL BE NEATLY PATCHED AND FINISHED <br />TO MATCH NEW/EXISTING. STRUCTURAL MEMBERS SHALL NOT BE CUT OR <br />PENETRATED IN ANY MANNER. THE SPACES AROUND THE CONDUITS SHALL BE <br />SEALED TO PREVENT ENTRANCE OF MOISTURE. PROVIDE FIRE STOPPING PER UL <br />APPROVED METHODS. <br />F REMOVE ABANDONED WIRING COMPLETE. AT CONTRACTORS OPTION, UTILIZE <br />EXISTING ABANDONED RACEWAY TO EXTENT AVAILABLE. EXPOSED ABANDONED <br />RACEWAY SHALL BE REMOVED. <br />G COORDINATE WORK IN PHASES WITH GENERAL CONTRACTOR AND OWNER TO <br />FACILITATE DEMOLITION AND NEW CONSTRUCTION. <br />H REMOVE ELECTRICAL RELATED EQUIPMENT (I.E JUNCTION BOXES, RECEPTACLES, <br />SWITCHES, DEVICES, ETC... ) AFFECTED/ABANDONED AS A RESULT OF DEMOLITION <br />AND NEW CONSTRUCTION. <br />20 <br />2 <br />4 <br /> <br /> <br />D <br />X <br />U <br />- <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />© <br />SEAL <br />PROJECT TEAM <br />MUNICIPAL APPROVAL STAMP <br />THESE DRAWINGS ARE CONFIDENTIAL AND SHALL BE IN THE <br />POSSESSION OF AUTHORIZED INDIVIDUALS ONLY. THESE DOCUMENTS <br />ARE THE EXCLUSIVE PROPERTY OF DxU ARCHITECTS AND SHALL NOT <br />BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION <br />SHEET TITLE & NUMBER <br />CLIENT <br />PROJECT <br />PROJECT NUMBER: <br />APPROVED BY: KKDRAWN BY: YP <br />NO. DATE ISSUE <br />OWNER <br />METHOD ART CORP <br />CONTACT: BRYNN MINER <br />(P) 714.599.1112 <br />EMAIL: MYCAVALIERS@HOTMAIL.COM <br />11-05-25 <br />E101 <br />LEVEL 1 POWER <br />PLAN <br />7-ELEVEN WIN <br />COFFEE <br />1700 E DYER ROAD <br />SANTA ANA, CA. 92705 <br />STORE# 33155 <br />24-675 <br />Project Status <br />1/4" = 1'-0"E101 <br />1 POWER PLAN <br />Electrical Fixture Schedule <br />Identity Mark Comments Panel Circuit Number Apparent Load Count <br />Apparent Load <br />Input Voltage <br />E01 COFFEE BREWER A 7,9 5000 VA 1 208 V <br />E01 COFFEE BREWER A 28,30 5000 VA 1 208 V <br />E02 AUTOMATIC COFFEE MACHINE A 39,41 5000 VA 1 208 V <br />E03 FLAVOR STATION A 3 180 VA 1 180 VA 120 V <br />E06 HOT DOG GRILL A 27,29 1450 VA 1 208 V <br />E07 TAQUITO GRILL A 17,19 1450 VA 1 208 V <br />E11 COUNTERTOP OVEN A 22,24 4000 VA 1 208 V <br />E12 UPRIGHT FREEZER A 35 500 VA 1 500 VA 120 V <br />E14 HOT FOOD DISPLAY CABINET A 25 500 VA 1 500 VA 120 V <br />E14 HOT FOOD DISPLAY CABINET A 42 500 VA 1 500 VA 120 V <br />E20 COFFEE WARMER A 20 180 VA 1 180 VA 0 V <br />CIRCUITING NOTE: <br />CIRCUIT NUMBERS SHOWN FOR REFERENCE ONLY. CONNECT TO <br />AVAILABLE CIRCUITS IN EXISTING PANELS. <br />NTSE101 <br />2 ELECTRICAL RISER DIAGRAM <br />Motor = LARGEST MOTOR <br />MN = MOTOR (NON-SEASONAL) <br />L = LIGHTING (CONTINUOUS) <br />R = RECEPTACLE <br />C = CONTINUOUS <br />PN = POWER NON-SEASONAL (NON-CONTINUOUS) <br />G = GFCI TYPE CIRCUIT BREAKER <br />Notes: <br />Total Est. Demand:89.1 A <br />Total Conn.:133.9 A <br />Total Est. Demand:32111 VA <br />-KIT 46078 VA 65.00% 29951 VA Total Conn. Load:48238 VA <br />RCPT 2160 VA 100.00% 2160 VA <br />Load Classification Connected Load Demand Factor Estimated Demand Panel Totals <br />Total Amps:124.1 A 169.9 A 111.4 A <br />Total Load:14689 VA 20184 VA 13365 VA <br />41 2500 VA 1300 VA 1 20.0 A -KIT PASTRY CASE 42 <br />39 G FRANKE COFFEE -KIT 30.0 A 2 2500 VA 2000 VA 40 <br />37 RECEPTACLE RCPT 20.0 A 1 180 VA 2000 VA 2 50.0 A -KIT SLURPEE 38 <br />35 FRIDGE -KIT 20.0 A 1 500 VA 540 VA 1 20.0 A RCPT ITIC 36 <br />33 2000 VA 800 VA 1 20.0 A -KIT GRINDER 34 <br />31 G COFFEE -KIT 20.0 A 2 2000 VA 540 VA 1 20.0 A RCPT RECEPTACLE 32 <br />29 725 VA 2500 VA 30 <br />27 G ROLLER GRILL -KIT 20.0 A 2 725 VA 2500 VA 2 30.0 A -KIT COFFEE BREWER G 28 <br />25 G HOT FOOD CASE -KIT 20.0 A 1 500 VA 180 VA 1 20.0 A RCPT CONDIMENT FRIDGE 26 <br />23 75 VA 2000 VA 24 <br />21 ICE MAKER -KIT 20.0 A 2 75 VA 2000 VA 2 30.0 A -KIT DOYON OVEN G 22 <br />19 725 VA 980 VA 1 20.0 A -KIT GRINDER 20 <br />17 G ROLLER GRILL -KIT 20.0 A 2 725 VA 180 VA 1 20.0 A RCPT RECEPTACLE 18 <br />15 2000 VA 104 VA 16 <br />13 SLURPEE -KIT 20.0 A 2 2000 VA 104 VA 2 20.0 A -KIT MICROWAVE 14 <br />11 CAPPUCCINNO -KIT 20.0 A 1 800 VA 540 VA 1 20.0 A RCPT RECEPTACLES 12 <br />9 2500 VA 800 VA 1 20.0 A -KIT FREEZER 10 <br />7 G COFFEE BREWER -KIT 30.0 A 2 2500 VA 800 VA 1 20.0 A -KIT MICROWAVE 8 <br />5 MILK FRIDGE -KIT 20.0 A 1 180 VA 800 VA 1 20.0 A -KIT FRIDGE 6 <br />3 FLAVOR STATION -KIT 20.0 A 1 180 VA 2000 VA 4 <br />1 SODA DISPENSER -KIT 20.0 A 1 180 VA 2000 VA 2 30.0 A -KIT TURBO CHEF 2 <br />CCT <br />NOTE <br />S Circuit Description <br />Load <br />Type Rating Poles A B C A B C Poles Rating <br />Load <br />Type Circuit Description <br />NOTE <br />S CCT <br />Notes: <br />GFP: <br />Enclosure:NEMA1 Ground Bus: Bus Rating:225 AMPS <br />Mounting:SURFACE Wires:4 Mains Rating:225.0 A <br />Supply From: Phases:3 Mains Type:MLO <br />Location: Volts:208Y/120 A.I.C. Rating:10,000 AMPS SYMMETRICAL <br />Branch Panel: A <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 City Comments
The URL can be used to link to this page
Your browser does not support the video tag.