1P 1 POLE (2P, 3P, 4P, ETC.)
<br />A AMPERE
<br />AC ABOVE COUNTER
<br />ACLG ABOVE CEILING
<br />ADO AUTOMATIC DOOR OPENER
<br />AF AMP FRAME
<br />AFF ABOVE FINISHED FLOOR
<br />AFG ABOVE FINISHED GRADE
<br />AFI ARC FAULT CIRCUIT
<br /> INTERRUPTER
<br />AHU AIR HANDLING UNIT
<br />AL ALUMINUM
<br />ALT ALTERNATE
<br />AMP AMPERE
<br />AMPL AMPLIFIER
<br />ANNUN ANNUNCIATOR
<br />APPROX APPROXIMATELY
<br />AQ-STAT AQUASTAT
<br />ARCH ARCHITECT, ARCHITECTURAL
<br />AS AMP SWITCH
<br />AT AMP TRIP
<br />ATS AUTOMATIC TRANSFER SWITCH
<br />AUTO AUTOMATIC
<br />AUX AUXILIARY
<br />AV AUDIO VISUAL
<br />AWG AMERICAN WIRE GAUGE
<br />BATT BATTERY
<br />BD BOARD
<br />BLDG BUILDING
<br />BMS BUILDING MANAGEMENT SYSTEM
<br />C CONDUIT
<br />CAB CABINET
<br />CAT CATALOG
<br />CATV CABLE TELEVISION
<br />CB CIRCUIT BREAKER
<br />CCTV CLOSED CIRCUIT TELEVISION
<br />CKT CIRCUIT
<br />CLG CEILING
<br />COMB COMBINATION
<br />CMPR COMPRESSOR
<br />CONN CONNECTION
<br />CONST CONSTRUCTION
<br />CONT CONTINUATION OR CONTINUOUS
<br />CONTR CONTRACTOR
<br />CONV CONVECTOR
<br />CP CIRCULATING PUMP
<br />CRT CATHODE-RAY TUBE
<br />CT CURRENT TRANSFORMER
<br />CTR CENTER
<br />CU COPPER
<br />DCP DOMESTIC WATER CIRCULATING PUMP
<br />DEPT DEPARTMENT
<br />DET DETAIL
<br />DIA DIAMETER
<br />DISC DISCONNECT
<br />DIST DISTRIBUTION
<br />DN DOWN
<br />DPR DAMPER
<br />DS SAFETY DISCONNECT SWITCH
<br />DT DOUBLE THROW
<br />DWG DRAWING
<br />EC ELECTRICAL CONTRACTOR
<br />ELEC ELECTRIC, ELECTRICAL
<br />ELEV ELEVATOR
<br />ELU EMERGENCY LIGHTING UNIT
<br />EM EMERGENCY
<br />EMS ENERGY MANAGEMENT SYSTEM
<br />EMT ELECTRICAL METALLIC TUBING
<br />EP ELECTRIC PNEUMATIC
<br />EQUIP EQUIPMENT
<br />EWC ELECTRIC WATER COOLER
<br />EXIST EXISTING
<br />EXH EXHAUST
<br />EXP EXPLOSION PROOF
<br />FA FIRE ALARM
<br />FABP FIRE ALARM BOOSTER POWER
<br />SUPPLY PANEL
<br />FACP FIRE ALARM CONTROL PANEL
<br />FCU FAN COIL UNIT
<br />FIXT FIXTURE
<br />FLR FLOOR
<br />FLUOR FLUORESCENT
<br />FU FUSE
<br />FUDS FUSED SAFETY DISCONNECT SWITCH
<br />GA GAUGE
<br />GAL GALLON
<br />GALV GALVANIZED
<br />GC GENERAL CONTRACTOR
<br />GEN GENERATOR
<br />GFI GROUND FAULT CIRCUIT INTERRUPTER
<br />GFP GROUND FAULT PROTECTOR
<br />GND GROUND
<br />GRS GALVANIZED RIGID STEEL (CONDUIT)
<br />GYP BD GYPSUM BOARD
<br />HOA HANDS-OFF-AUTOMATIC SWITCH
<br />HORIZ HORIZONTAL
<br />HP HORSEPOWER
<br />HPF HIGH POWER FACTOR
<br />HT HEIGHT
<br />HTG HEATING
<br />HTR HEATER
<br />HV HIGH VOLTAGE
<br />HVAC HEATING, VENTILATING AND AIR
<br />CONDITIONING
<br />IC INTERRUPTING CAPACITY
<br />IG ISOLATED GROUND
<br />IMC INTERMEDIATE METAL CONDUIT
<br />INCAND INCANDESCENT
<br />IR INFRARED
<br />I/W INTERLOCK WITH
<br />J-BOX JUNCTION BOX
<br />KV KILOVOLT
<br />KVA KILOVOLT-AMPERE
<br />KVAR KILOVOLT-AMPERE REACTIVE
<br />KW KILOWATT
<br />KWH KILOWATT HOUR
<br />LOC LOCATE OR LOCATION
<br />LT LIGHT
<br />LTG LIGHTING
<br />LTNG LIGHTNING
<br />LV LOW VOLTAGE
<br />MAX MAXIMUM
<br />MAG.S MAGNETIC STARTER
<br />M/C MOMENTARY CONTACT
<br />MC MECHANICAL CONTRACTOR
<br />ELECTRICAL ABBREVIATIONS LIST ELECTRICAL SYMBOL NOTES
<br />EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING
<br />MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES
<br />DIRECTIONAL ARROW ON ILLUMINATED FACE(S). THE CIRCUIT DESIGNATION IS
<br />INDICATED BY A NUMBER. EXAMPLE: THE WALL MOUNTED EXIT LIGHT TYPE "E1"
<br />WITH SINGLE FACE AND DIRECTIONAL ARROW IS CONNECTED TO CIRCUIT 1.
<br />DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. THE SWITCH
<br />DESIGNATION IS INDICATED BY A LOWER CASE LETTER. EXAMPLE: SPLIT
<br />DUPLEX RECEPTACLE IS CONNECTED TO CIRCUIT 1 AND ONE RECEPTACLE
<br />OUTLET IS CONTROLLED BY SWITCH "d".
<br />THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
<br />EXAMPLE: SINGLE POLE SWITCH "d" TO CONTROL LIGHTING FIXTURES INDICATED
<br />BY "d".
<br />WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE: 600 WATT
<br />WALL BOX DIMMER TO CONTROL LIGHTING FIXTURES INDICATED BY "e". SEE
<br />SPECIFICATIONS FOR WATTAGE IF NOT INDICATED.
<br />SPECIAL CONNECTIONS. THE EQUIPMENT IS INDICATED BY A NUMBER IN A
<br />CIRCLE. SEE THE MOTOR AND EQUIPMENT SCHEDULE FOR THE LOAD
<br />DESCRIPTION AND TYPE OF CONNECTION. THE CIRCUIT DESIGNATION IS
<br />INDICATED BY NUMBER(S) ADJACENT TO THE SYMBOL. EXAMPLE: EQUIPMENT NO.
<br />ELEC-1; 1 PHASE CONNECTION TO CIRCUITS 2, 4.
<br />MOTOR CONNECTIONS. THE MOTOR IS INDICATED BY A NUMBER WITHIN OR
<br />CHARACTERS ADJACENT TO THE MOTOR SYMBOL. SEE THE MOTOR AND
<br />EQUIPMENT SCHEDULE FOR THE MOTOR DESCRIPTION AND ELECTRICAL
<br />REQUIREMENTS.
<br />TRANSFORMERS. THE TRANSFORMER TYPE IS INDICATED BY A NUMBER
<br />FOLLOWING THE UPPER CASE LETTER "T". SEE THE TRANSFORMER
<br />SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER
<br />DESCRIPTION AND REQUIREMENTS. EXAMPLE: TRANSFORMER TYPE "T1".
<br />PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING
<br />SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR
<br />DESIGNATION CODES.
<br />CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 1 # 12 CONDUCTOR
<br />PER PHASE, NEUTRAL, AND GROUND IN 1/2" CONDUIT UNLESS SPECIFIC
<br />EQUIPMENT REQUIRES A DIFFERENT SIZE.
<br />CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR PER PHASE IN ELECTRICAL
<br />CODE SIZED MINIMUM CONDUIT UNLESS A CONDUCTOR AND CONDUIT SIZE IS
<br />SHOWN ADJACENT.
<br />HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE PANELBOARD DESIGNATION
<br />IS SHOWN ADJACENT TO THE HOME RUN ARROW AS A NUMERATOR AND THE
<br />CIRCUIT DESIGNATION IS SHOWN AS THE DENOMINATOR. CIRCUIT BREAKER
<br />SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANELBOARD SCHEDULE
<br />WITH THE CORRESPONDING PANELBOARD AND CIRCUIT DESIGNATION.
<br />EXAMPLE: HOME RUN TO PANELBOARD P4N-102; CIRCUITS 1, 3, 5.
<br />SYMBOLSYMBOLSYMBOL
<br />ELECTRICAL SYMBOL LEGEND
<br />DESCRIPTION DESCRIPTION DESCRIPTION
<br />FIRE ALARM HORN W/STROBE
<br />FIRE ALARM BELL
<br />FIRE ALARM BELL W/STROBE
<br />FIRE ALARM CHIME W/STROBE
<br />TIME CONTROL SWITCH
<br />RELAY
<br />CABLE TAP BOX
<br />SAFETY DISC. SW. (FUSED)
<br />SAFETY DISC. SW. (NON-FUSED)
<br />COMB. MOTOR STARTER (FUSED)
<br />MOTOR
<br />TRANSFORMER
<br />FLOOR JUNCTION BOX
<br />JUNCTION BOX
<br />UTILITY SERVICE POWER POLE
<br />STATIC GROUND RECEPTACLE
<br />SURGERY SERVICE COLUMN
<br />POWER POLE (OPEN OFFICE STYLE)
<br />MULTIOUTLET ASSEMBLY
<br />RECEPT. ON CORD REEL
<br />FLOOR DUPLEX RECEPT.
<br />240V RECEPTACLE
<br />FOURPLEX RECEPT. ON EMERG. CIRCUIT
<br />FOURPLEX RECEPT.
<br />DUPLEX RECEPT. ON EMERG. CIRCUIT
<br />DUPLEX ISOLATED GROUND RECEPT.
<br />SPLIT DUPLEX RECEPT.
<br />DUPLEX RECEPT.
<br />SINGLE RECEPT.
<br />PUSH BUTTON
<br />TIME DELAY SWITCH
<br />TIMER SWITCH
<br />OCCUPANCY SENSOR W/ MANUAL SWITCH
<br />DIMMER SWITCH
<br />SWITCH W/PILOT
<br />KEYED SWITCH
<br />4-WAY SWITCH
<br />3-WAY SWITCH
<br />SINGLE POLE SWITCH
<br />BUS DUCT W/ PLUG IN DISCONNECT
<br />PS - D2
<br />T1
<br />PANELBOARD IDENTIFICATION
<br />1
<br />KEYED NOTE (SEE SCHEDULE)
<br />NUMBER OF SHEET WHERE DETAIL APPEARS
<br />NUMBER OF DETAIL ON SHEET
<br />REVISION NUMBER -SHOWN ON PLANS
<br />ROOM NAME AND NUMBER
<br />ITEM TO BE
<br />REMOVED
<br />AREA NOT IN
<br />CONTRACT
<br />1
<br />-
<br />---
<br />XX-1 IDENTITY (SEE SCHEDULE)
<br />XX-1
<br />EXISTING TO REMAIN
<br />XX-1
<br />RELOCATED
<br />XX-1
<br />DEMOLISHED
<br />1d
<br />d
<br />e
<br />2,4
<br />T1
<br />FLOOR CLEARANCE AREA
<br />CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD CONDITIONS
<br />CONDUIT IN FLOOR
<br />P4N-102
<br />1. EQUIPMENT DESIGNATION:
<br />L = LIGHTING
<br />P = POWER
<br />D = DISTRIBUTION
<br />S = SWITCHBOARD
<br />M = MOTOR CONTROL CENTER
<br />R = RELAY PANEL
<br />2. VOLTAGE DESIGNATION:
<br />1 = 120/240V -1PH
<br />2 = 240V -3PH
<br />3 = 208Y/120V -3PH
<br />4 = 480Y/277V -3PH
<br />5 = 120/208 -1PH
<br />6 = SPECIAL
<br />3. SYSTEM DESIGNATION:
<br />N = NORMAL
<br />E = EMERGENCY
<br />C = POWER CONDITIONED
<br />U = UNINTERRUPTIBLE POWER SOURCE
<br />4. FLOOR DESIGNATION:
<br />B = BASEMENT
<br />G = GROUND
<br />1 = FIRST FLOOR
<br />2 = SECOND FLOOR
<br />ETC.
<br />5. PANEL NO. DESIGNATION:
<br />01 = PANELBOARD #1
<br />02 = PANELBOARD #2
<br />03 = PANELBOARD #3
<br />ETC.
<br />FIRE ALARM PULL STATION
<br />FIRE ALARM DOOR HOLDER
<br />FIRE ALARM DOOR CLOSER
<br />FIRE ALARM SHUT DOWN RELAY
<br />CEILING DATA OUTLET
<br />FLOOR DATA OUTLET
<br /># OF VOICE AND # OF DATA OUTLETS.
<br />FOR EXAMPLE 1V2D = 1 VOICE, 2 DATA
<br />P4N-102
<br />1, 3, 5
<br />#10
<br />#12
<br />EXISTING TO REMAIN
<br />EXISTING TO BE REMOVED
<br />NEW
<br />GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL SYMBOLS.
<br />CEILING DUPLEX RECEPT.
<br />SPECIAL RECEPT.
<br />CEILING JUNCTION BOX
<br />FLOOR TELEPHONE OUTLET
<br />GFI DUPLEX RECEPT. (FEED THROUGH)
<br />GFI WEATHERPROOF RECEPT.
<br />DUPLEX RECEPT.
<br />(DESIGNATES SPECIFIC MOUNTING HEIGHT)48"
<br />GFI
<br />GFI
<br />WP
<br />CLNG
<br />ELEC-1
<br />Room
<br />6
<br />FIRE ALARM SPEAKER W/STROBE
<br />MCB MAIN CIRCUIT BREAKER
<br />MCC MOTOR CONTROL CENTER
<br />MDC MAIN DISTRIBUTION CENTER
<br />MDP MAIN DISTRIBUTION PANEL
<br />MFR MANUFACTURER
<br />MFS MAIN FUSED DISCONNECT SW
<br />MH MANHOLE
<br />MIC MICROPHONE
<br />MIN MINIMUM
<br />MISC MISCELLANEOUS
<br />MLO MAIN LUGS ONLY
<br />MMS MANUAL MOTOR STARTER
<br />MOA MULTIOUTLET ASSEMBLY
<br />MSP MOTOR STARTER PANELBOARD
<br />MSBD MAIN SWITCHBOARD
<br />MT MOUNT
<br />MT.C EMPTY CONDUIT
<br />MTS MANUAL TRANSFER SWITCH
<br />MTR MOTOR, MOTORIZED
<br />N.C. NORMALLY CLOSED
<br />NEC NATIONAL ELECTRICAL CODE
<br />NEMA NATIONAL ELECTRICAL
<br />MANUFACTURER'S ASSOCIATION
<br />NFDS NON-FUSED SAFETY DISCONNECT
<br />SWITCH
<br />NIC NOT IN CONTRACT
<br />NL NIGHT LIGHT
<br />N.O. NORMALLY OPEN
<br />NPF NORMAL POWER FACTOR
<br />NTS NOT TO SCALE
<br />OH OVERHEAD
<br />OL OVERLOADS
<br />PA PUBLIC ADDRESS
<br />PB PULL BOX OR PUSHBUTTON
<br />PE PNEUMATIC ELECTRIC
<br />PED PEDESTAL
<br />PF POWER FACTOR
<br />PH PHASE
<br />PIV POST INDICATING VALVE
<br />PNL PANEL
<br />PP POWER POLE
<br />PR PAIR
<br />PRI PRIMARY
<br />PROJ PROJECTION
<br />PRV POWER ROOF VENTILATOR
<br />PT POTENTIAL TRANSFORMER
<br />PVC POLYVINYL CHLORIDE (CONDUIT)
<br />PWR POWER
<br />QUAN QUANTITY
<br />RCPT RECEPTACLE
<br />REQD REQUIRED
<br />RM ROOM
<br />RSC RIGID STEEL CONDUIT
<br />RTU ROOF TOP UNIT
<br />SC SURFACE CONDUIT
<br />SEC SECONDARY
<br />SHT SHEET
<br />SIM SIMILAR
<br />S/N SOLID NEUTRAL
<br />SPEC SPECIFICATION
<br />SPKR SPEAKER
<br />SP SPARE
<br />SR SURFACE RACEWAY
<br />SS STAINLESS STEEL
<br />SSW SELECTOR SWITCH
<br />S/S STOP/START PUSHBUTTONS
<br />STA STATION
<br />STD STANDARD
<br />SURF SURFACE MOUNTED
<br />SW SWITCH
<br />SWBD SWITCHBOARD
<br />SYM SYMMETRICAL
<br />SYS SYSTEM
<br />TEL TELEPHONE
<br />TEL/DATA TELEPHONE/DATA
<br />TERM TERMINAL
<br />TL TWIST LOCK
<br />TR TAMPER RESISTANT
<br />T-STAT THERMOSTAT
<br />TTC TELEPHONE TERMINAL CABINET
<br />TV TELEVISION
<br />TVTC TELEVISION TERMINAL CABINET
<br />TYP TYPICAL
<br />UC UNDER COUNTER
<br />UE UNDERGROUND ELECTRICAL
<br />UG UNDERGROUND
<br />UH UNIT HEATER
<br />UT UNDERGROUND TELEPHONE
<br />UTIL UTILITY
<br />UV ULTRAVIOLET
<br />V VOLT
<br />VA VOLT-AMPERES
<br />VDT VIDEO DISPLAY TERMINAL
<br />VERT VERTICAL
<br />VFD VARIABLE FREQUENCY DRIVE
<br />VOL VOLUME
<br />W WATT
<br />W/ WITH
<br />WG WIRE GUARD
<br />WH WATER HEATER
<br />W/O WITHOUT
<br />WP WEATHERPROOF
<br />XFMR TRANSFORMER
<br />XFR TRANSFER
<br />∠ ANGLE
<br />@ AT
<br />▲ DELTA
<br />' FEET
<br />" INCHES
<br /># NUMBER
<br />Ø PHASE
<br />C CENTER LINE
<br />P PLATE
<br />EXIT LIGHT, WALL-MOUNTED, SHADING
<br />AND ARROWS INDICATE FACES AND
<br />DIRECTION
<br />WALL-MOUNTED FIXTURES, TYPICAL
<br />EXW1
<br />1
<br />LIGHTING FIXTURE TAG DESCRIPTORS:
<br />TOP VALUE: FIXTURE TYPE ID.
<br />BOTTOM VALUE, NUMBER: CIRCUIT NUMBER, REFER TO DRAWINGS FOR
<br />PANEL.
<br />BOTTOM VALUE, LOWERCASE LETTER: SWITCH DESIGNATION.
<br />ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE ONLY
<br />SWITCH IN THE SPACE.
<br />"x" IN PLACE OF THE SWITCH ID INDICATES NIGHT LIGHT, UNSWITCHED.
<br />S3
<br />1d
<br />ELECTRIC STRIKE
<br />MAGNETIC LOCK
<br />COMBINATION LOCK
<br />DOOR CONTACT
<br />CARD READER
<br />SECURITY KEYPAD
<br />MOTION DETECTOR
<br />NURSE CALL EMERG. STATION
<br />NURSE CALL CODE BLUE STATION
<br />NURSE CALL DUTY STATION
<br />NURSE CALL STAFF STATION
<br />NURSE CALL PATIENT STATION
<br />NURSE CALL DOME LIGHT (1-COLOR)
<br />TELEPHONE OUTLET
<br />VOICE/DATA OUTLET
<br />DOOR BELL
<br />DOOR BUZZER
<br />DOOR CHIME
<br />DOOR SIGNAL
<br />VOLUME CONTROL
<br />MICROPHONE OUTLET
<br />1V2D
<br />CATV OUTLET
<br />TV OUTLET
<br />NURSE CALL DOME LIGHT (2-COLORS)
<br />AUTO DOOR PUSH PAD
<br />EMERGENCY LIGHTING UNIT, WALL-
<br />MOUNTED, REMOTE BATTERY
<br />EMERGENCY LIGHTING UNIT, WALL-
<br />MOUNTED, INTEGRAL BATTERY
<br />EMERGENCY LIGHTING UNIT, CEILING-
<br />MOUNTED, INTEGRAL BATTERY
<br />EMERGENCY LIGHTING UNIT, CEILING-
<br />MOUNTED, REMOTE BATTERY
<br />LIGHTING FIXTURES, TYPICAL,
<br />RECTANGULAR
<br />FILLED CIRCLES INDICATE RECESSED,
<br />OPEN CIRCLES INDICATE SURFACE
<br />DIAGONAL LINE INDICATES LENSED
<br />OUTER DOTS INDICATE SUSPENDED
<br />LIGHTING FIXTURES, TYPICAL, ROUND
<br />CENTER DOT INDICATES PENDANT
<br />DIAGONAL LINE INDICATES LENSED
<br />CHEVRON INDICATES WALL WASH
<br />STRIP FIXTURE
<br />DIRECTIONAL LIGHT, TRACK, FLOOD
<br />EXIT LIGHT, CEILING-MOUNTED, SHADING
<br />AND ARROWS INDICATE FACES AND
<br />DIRECTION
<br />LINEAR LIGHT, TAPE LIGHT
<br />EXIT/ELU COMBO
<br />DIAGONAL HATCH INDICATES LIGHT ON A
<br />CRITICAL CIRCUIT
<br />SOLID HATCH INDICATES LIGHT ON AN
<br />EMERGENCY OR LIFE SAFETY CIRCUIT
<br />POLE/AREA LIGHTS
<br />POST-TOP AREA LIGHT
<br />BOLLARD LIGHT
<br />SPRINKLER FLOW SWITCH
<br />SPRINKLER VALVE TAMPER SWITCH
<br />DUCT SMOKE DETECTOR
<br />CEILING SMOKE DETECTOR
<br />THERMAL DETECTOR
<br />ELECTRICAL SHEET INDEX
<br />SHEET DESCRIPTION
<br />E000 ELECTRICAL TITLE SHEET
<br />E001 ELECTRICAL SPECIFICATONS
<br />E002 ELECTRICAL SPECIFICATONS
<br />E101 LEVEL 1 POWER PLAN
<br />SHEET COUNT: 4
<br />ELECTRICAL GENERAL NOTES
<br />A CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.
<br />RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.
<br />RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE
<br />THE STRUCTURE SHALL BE PVC.
<br />B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS
<br />SHALL BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR
<br />INACCESSIBLE SPACES. LOW VOLTAGE CABLES MAY BE RUN IN CABLE TRAY
<br />WHERE NOTED. LOW VOLTAGE CABLES MAY BE RUN IN CABLE SUPPORT HOOKS
<br />ABOVE ACCESSIBLE CEILINGS WHERE NOTED. LOW VOLTAGE CABLE SHALL BE
<br />PLENUM RATED IN PLENUM SPACES.
<br />C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND
<br />DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER
<br />LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.
<br />D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING
<br />SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA.
<br />PROVIDE DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING
<br />,UNLESS NOTED OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER
<br />CONDUCTORS INCLUDING EQUIPMENT GROUNDING CONDUCTORS
<br />PROPORTIONALLY FOR NO MORE THAN 3% VOLTAGE DROP ON BRANCH
<br />CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.
<br />E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION
<br />OF ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS
<br />TO MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO
<br />AREAS ABOVE ACCESSIBLE CEILINGS.
<br />F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF EQUIPMENT.
<br />CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS
<br />WITH EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO ROUGH-IN
<br />AND AT NO ADDITIONAL COST TO THE OWNER.
<br />G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS,
<br />EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS
<br />SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK
<br />DURING CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND
<br />FOREIGN MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.
<br />H THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
<br />USED IN THIS SET OF DRAWINGS.
<br />I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD
<br />WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS
<br />ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE
<br />NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND
<br />ORDINANCES.
<br />J FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT LOCATIONS ALONG
<br />WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO ROUGH-IN.
<br />ADJUST CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCH CIRCUITING
<br />ACCORDINGLY.
<br />K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A
<br />LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY
<br />FEES ASSOCIATED WITH THIS WORK.
<br />L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL
<br />GRADE, FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING
<br />LABORATORY UNO.
<br />M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING
<br />APPROVED SUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT
<br />SUPPLIED,AND MANUFACTURES OPERATION AND
<br />MAINTENANCE INSTRUCTIONS.
<br />20
<br />2
<br />4
<br />
<br />
<br />D
<br />X
<br />U
<br />-
<br />A
<br />R
<br />C
<br />H
<br />I
<br />T
<br />E
<br />C
<br />T
<br />S
<br />
<br />A
<br />l
<br />l
<br />
<br />r
<br />i
<br />g
<br />h
<br />t
<br />s
<br />
<br />r
<br />e
<br />s
<br />e
<br />r
<br />v
<br />e
<br />d
<br />.
<br />©
<br />SEAL
<br />PROJECT TEAM
<br />MUNICIPAL APPROVAL STAMP
<br />THESE DRAWINGS ARE CONFIDENTIAL AND SHALL BE IN THE
<br />POSSESSION OF AUTHORIZED INDIVIDUALS ONLY. THESE DOCUMENTS
<br />ARE THE EXCLUSIVE PROPERTY OF DxU ARCHITECTS AND SHALL NOT
<br />BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION
<br />SHEET TITLE & NUMBER
<br />CLIENT
<br />PROJECT
<br />PROJECT NUMBER:
<br />APPROVED BY: KKDRAWN BY: YP
<br />NO.DATE ISSUE
<br />OWNER
<br />METHOD ART CORP
<br />CONTACT: BRYNN MINER
<br />(P) 714.599.1112
<br />EMAIL: MYCAVALIERS@HOTMAIL.COM
<br />11-05-25
<br />E000
<br />ELECTRICAL TITLE
<br />SHEET
<br />7-ELEVEN WIN
<br />COFFEE
<br />1700 E DYER ROAD
<br />SANTA ANA, CA. 92705
<br />STORE# 33155
<br />24-675
<br />Project Status
<br />1 City Comments
|