My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 E Dyer Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
1700 E Dyer Rd
>
1700 E Dyer Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:16 AM
Creation date
2/13/2026 5:01:11 AM
Metadata
Fields
Template:
Plan
Permit Number
20186841
101124762
Full Address
1700 E Dyer Rd
Street Number
1700
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
Document Relationships
101124762 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\1700 E Dyer Rd
20186841 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\1700 E Dyer Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
· GFCI CIRCUIT BREAKER INSTALLED WITHIN THE PANEL FOR SERVICE TO THE CIRCUIT OR <br />CIRCUITS. <br />· GFCI CIRCUIT BREAKER INSTALLED WITHIN AN INDIVIDUAL ENCLOSURE EXTERNAL TO THE PANEL <br />FOR SERVICE TO THE CIRCUIT. <br />· DEAD-FRONT GFCI DEVICE INSTALLED IN A READILY ACCESSIBLE LOCATION AS DEFINED BY THE <br />NEC (APPLICABLE TO 20 AMP, 120 VOLT CIRCUITS). <br />· AN INDIVIDUALLY MOUNTED EXTERNAL SPECIAL PURPOSE GROUND FAULT CIRCUIT INTERRUPTER <br />(SPGFCI) DEVICE SIMILAR TO “SHOCK BLOCK” PRODUCTS AS MANUFACTURED BY LITTLEFUSE, OR <br />APPROVED EQUAL. <br />· DEAD FRONT DEVICES SHALL BE BE LABELED TO IDENTIFY THE CIRCUIT AND THE LOAD SERVED <br />BY THE DEVICE. <br />TESTING <br />A. PROVIDE ALL TESTS AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. <br />B. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS REQUIRED TO ESTABLISH THE <br />ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS AND SUITABLE OPERATION OF EACH SYSTEM. <br />C. PROMPTLY CORRECT ANY FAILURES, DEFICIENCIES AND/OR DEFECTS REVEALED BY THESE TESTS. <br />AFTER CORRECTING FAILURES, DEFICIENCIES OF DEFECTS, CONDUCT NEW TESTING TO VERIFY THAT <br />THE DEFICIENCY HAS BEEN RECTIFIED AND THE SYSTEM IS FUNCTIONING PROPERLY. <br />D. NEW AND EXISTING PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10% <br />VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. <br />E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTING/EXIT SIGNAGE SYSTEM SHALL BE <br />PERFORMED IN THE PRESENCE OF THE OWNER AND THE AUTHORITY HAVING JURISDICTION TO <br />DEMONSTRATE PROPER OPERATION AND COMPLIANCE WITH APPLICABLE CODES AND SPECIFIED <br />REQUIREMENTS. <br />WARRANTY <br />A. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS, EQUIPMENT AND THE INSTALLATION TO BE <br />FREE OF DEFECTS THAT MAY DEVELOP IN ANY PART OF THEIR WORK CAUSED BY FAULTY <br />WORKMANSHIP, MATERIAL OR EQUIPMENT FAILURES, FOR A MINIMUM OF ONE (1) YEAR FROM THE DATE <br />OF SUBSTANTIAL COMPLETION OR FOR AS LONG AS NORMAL EQUIPMENT MANUFACTURER <br />WARRANTIES ARE IN EFFECT FROM THE DATE OF OWNER ACCEPTANCE OF THE PROJECT, WHICHEVER <br />IS LATER. <br />B. DURING THE ONE (1) YEAR WARRANTY PERIOD, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY <br />DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR DEFECTS IN THE WORK OR <br />EQUIPMENT FURNISHED AND/OR INSTALLED UNDER THE WORK OF THE ELECTRICAL CONTRACT. <br />RECEPTACLES <br />A. RECEPTACLES SHALL BE 20 AMP, 125 VOLT, 2-POLE, 3-WIRE, GROUNDING TYPE, NEMA 5-20R <br />WITH SCREW TERMINALS. HUBBELL 5362-W OR APPROVED EQUAL BY ONE OF THE ADDITIONAL <br />MANUFACTURERS SPECIFIED HEREIN. <br />B. GFCI RECEPTACLES SHALL BE 20 AMP, 125 VOLT, 2-POLE, 3-WIRE, GROUNDING TYPE, NEMA <br />5-20R FEED THROUGH TYPE CAPABLE OF PROTECTING DOWNSTREAM RECEPTACLES ON A SINGLE <br />CIRCUIT, SOLID STATE GROUND FAULT SENSING AND SIGNALING, 5 MILLIAMP TRIP LEVEL, NEMA <br />5-20R WITH SCREW TERMINALS. HUBBELL GF5362-X OR APPROVED EQUAL BY ONE OF THE <br />ADDITIONAL MANUFACTURERS SPECIFIED HEREIN. <br />C. ISOLATED GROUND RECEPTACLES SHALL BE ORANGE, 20 AMP, 125 VOLT, 2-POLE, 3-WIRE, <br />GROUNDING TYPE, NEMA 5-20R WITH SCREW TERMINALS. HUBBELL IG-5362-W OR APPROVED <br />EQUAL BY ONE OF THE ADDITIONAL MANUFACTURERS SPECIFIED HEREIN. <br />D. PROVIDE SPECIAL PURPOSE RECEPTACLES HAVING NEMA CONFIGURATIONS THAT MATE AND <br />MATCH THE NEMA PLUG CONFIGURATION PROVIDED WITH THE EQUIPMENT TO BE CONNECTED. <br />E. COVER PLATES FOR EXTERIOR RECEPTACLES SHALL BE RATED FOR “WEATHERPROOF WHILE <br />IN USE”. <br />F. DEVICE COLOR SHALL BE AS SELECTED BY THE OWNER/ARCHITECT. <br />G. QUAD RECEPTACLES SHALL CONSIST OF (2) DUPLEX RECEPTACLES INSTALLED IN A SINGLE <br />BOX UNDER A SINGLE COVER PLATE. <br />H. RECEPTACLES SHALL BE INSTALLED SURFACE MOUNTED IN UNFINISHED SPACES, FLUSH <br />MOUNTED IN FINISHED SPACES. <br />I. ADDITIONAL ACCEPTABLE MANUFACTURERS FOR SWITCHES AND RECEPTACLES: LEGRAND, <br />LEVITON. <br />GFCI PROTECTION: <br />A. ALL KITCHEN SINGLE PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 AMPS <br />OR LESS AND THREE PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 AMPS OR <br />LESS SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL IN <br />ACCORDANCE WITH NEC 210.8, (B), (1) - (10), OR THE EQUIVALENT REQUIREMENT WITHIN THE <br />APPLICABLE ELECTRICAL CODE. <br />B. THE “GFCI” NOTATION AT A DEVICE OR CIRCUIT BREAKER INDICATES THAT GFCI PROTECTION <br />SHALL BE PROVIDED FOR THE CIRCUIT OR CIRCUITS INDICATED. GFCI PROTECTION SHALL BE <br />PROVIDED BY ONE OF THE FOLLOWING MEANS: <br />· INTEGRAL GFCI PROTECTION WITHIN THE DEVICE (NEMA 5-20R RECEPTACLES), WHEN THE <br />DEVICE IS ABLE TO BE INSTALLED IN A READILY ACCESSIBLE LOCATION AS DEFINED BY THE <br />APPLICABLE ELECTRICAL CODE. <br />20 <br />2 <br />4 <br /> <br /> <br />D <br />X <br />U <br />- <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />© <br />SEAL <br />PROJECT TEAM <br />MUNICIPAL APPROVAL STAMP <br />THESE DRAWINGS ARE CONFIDENTIAL AND SHALL BE IN THE <br />POSSESSION OF AUTHORIZED INDIVIDUALS ONLY. THESE DOCUMENTS <br />ARE THE EXCLUSIVE PROPERTY OF DxU ARCHITECTS AND SHALL NOT <br />BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION <br />SHEET TITLE & NUMBER <br />CLIENT <br />PROJECT <br />PROJECT NUMBER: <br />APPROVED BY: KKDRAWN BY: YP <br />NO. DATE ISSUE <br />OWNER <br />METHOD ART CORP <br />CONTACT: BRYNN MINER <br />(P) 714.599.1112 <br />EMAIL: MYCAVALIERS@HOTMAIL.COM <br />11-05-25 <br />E002 <br />ELECTRICAL <br />SPECIFICATONS <br />7-ELEVEN WIN <br />COFFEE <br />1700 E DYER ROAD <br />SANTA ANA, CA. 92705 <br />STORE# 33155 <br />24-675 <br />Project Status <br />1 <br />1 City Comments
The URL can be used to link to this page
Your browser does not support the video tag.