SUMMARY <br />A. GENERAL AND SUPPLEMENTARY CONDITIONS WITHIN THE SPECIFICATIONS ARE HEREBY <br />INCORPORATED AND BECOME PART OF THESE SPECIFICATIONS AND AS SUCH SHALL BE <br />APPLICABLE TO THE WORK OF THE ELECTRICAL CONTRACT. <br />B. PRIOR TO SUBMISSION OF A BID PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND <br />BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AND LIMITATIONS THAT IMPACT THE WORK OF <br />THIS CONTRACT. NO ADDITIONAL COSTS TO THE OWNER SHALL BE PERMITTED FOR CHANGES TO <br />THE WORK AS A RESULT OF THE CONTRACTORS FAILURE TO VISIT THE SITE PRIOR TO BIDDING AND <br />IDENTIFY ITEMS THAT WERE ABLE TO BE VERIFIED DURING A SITE VISIT PRIOR TO THE SUBMISSION <br />OF A BID PROPOSAL. <br />C. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, RIGGING, AND <br />MISCELLANEOUS ITEMS AS REQUIRED FOR A COMPLETE, OPERATIONAL, FUNCTIONAL AND CODE <br />COMPLIANT ELECTRICAL INSTALLATION AS SHOWN ON THE DRAWINGS AND AS SPECIFIED IN THESE <br />SPECIFICATIONS. <br />LANDLORDS REQUIREMENTS <br />A. ALL WORK OF THIS CONTRACT SHALL BE COMPLETED IN STRICT ACCORDANCE WITH ALL <br />APPLICABLE LANDLORD REQUIREMENTS INCLUDING BUT NOT NECESSARILY LIMITED TO; <br />LANDLORD'S WORK LETTER, LANDLORD'S CONSTRUCTION CRITERIA AND/OR THE <br />TENANT/LANDLORD AGREEMENT. THIS CONTRACTOR SHALL EXAMINE THESE DOCUMENTS PRIOR TO <br />THE SUBMISSION OF A BID PROPOSAL. <br />B. ALL APPLICABLE LANDLORD REQUIREMENTS INCLUDING BUT NOT NECESSARILY LIMITED TO THE <br />LANDLORD'S WORK LETTER, LANDLORDS CONSTRUCTION CRITERIA AND/OR THE TENANT/LANDLORD <br />AGREEMENT DOCUMENTS SHALL BE CONSIDERED PART OF THESE SPECIFICATIONS. <br />EXISTING CONDITIONS <br />A. THE CONTRACT DOCUMENTS ARE BASED ON INFORMATION PROVIDED TO THE CONSULTANT AT <br />THE TIME OF DESIGN. THIS CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO <br />SUBMITTING A BID PROPOSAL. <br />BIDS AND SUBSTITUTIONS <br />A. PRIOR TO SUBMISSION OF A BID PROPOSAL, CONTRACTOR SHALL THOROUGHLY REVIEW THE <br />BID INSTRUCTIONS AND ALL CIVIL, ARCHITECTURAL, STRUCTURAL, FOOD SERVICE AND MEPFP AND <br />TELECOMMUNICATION CONSTRUCTION DOCUMENTS. <br />B. SHOULD THE CONTRACTOR WISH TO SUBMIT AN ALTERNATE PRODUCT TO THE <br />MANUFACTURERS NAMED IN THESE SPECIFICATIONS OR ON THE DRAWINGS FOR ANY EQUIPMENT, <br />THE CONTRACTOR SHALL SUBMIT A VOLUNTARY ALTERNATIVE A MINIMUM OF SEVEN (7) CALENDAR <br />DAYS PRIOR TO BID, STATING THE MANUFACTURER'S NAME, MODEL NUMBER, WRITTEN, DETAILED <br />PRODUCT DATA. <br />C. WORK PERFORMED OR CONSTRUCTED WITH UNAPPROVED EQUALS IS AT CONTRACTOR'S RISK <br />AND ANY REQUIRED CORRECTION OF WORK INCORPORATING UNAPPROVED EQUALS SHALL BE AT <br />CONTRACTOR'S SOLE COST AND EXPENSE. <br />D. NO SUBSTITUTIONS PERMITTED FOR LIGHTING FIXTURES. <br />QUALITY ASSURANCE <br />A. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. <br />B. PROVIDE PERMITS, INSPECTIONS, FINAL CERTIFICATES OF INSPECTION BY THE AUTHORITY <br />HAVING JURISDICTION, PERMIT AND INSPECTION FEES AND ALL MATERIALS, EQUIPMENT AND LABOR <br />AS REQUIRED FOR A COMPLETE, FUNCTIONAL, FULLY OPERATIONAL AND CODE COMPLIANT <br />ELECTRICAL SYSTEM. <br />C. THIS CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND ACCESSORIES FOR A <br />COMPLETE FUNCTIONAL AND CODE COMPLIANT ELECTRICAL INSTALLATION, WHETHER OR NOT <br />SHOWN ON THE DRAWINGS OR SPECIFIED IN THESE SPECIFICATIONS. <br />D. EC SHALL VERIFY THE VOLTAGE AND AMPERAGE REQUIREMENTS OF ALL EQUIPMENT <br />DELIVERED TO THE SITE PRIOR TO CONNECTION. EC SHALL NOTIFY THE OWNER OF ANY <br />DIFFERENCES <br />E. REQUIREMENTS OF REGULATORY AGENCIES: <br />1. PERMITS: ARRANGE AND PAY FOR ALL PERMITS, INSPECTIONS AND UTILITY CONNECTIONS <br />REQUIRED. <br />2. PROVIDE ALL TESTS AND INSPECTIONS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. <br />3. PROVIDE A SIGNED CERTIFICATE OF INSPECTION AT THE COMPLETION OF THE PROJECT. <br />INCLUDE IN OPERATION AND MAINTENANCE MANUALS. <br />F. CODES AND STANDARDS <br />1. COMPLY WITH SPECIFIED CODES AND STANDARDS. IF CONFLICT EXISTS BETWEEN CODES OR <br />STANDARDS AND DRAWINGS, PROJECT MANUAL OR ADDENDA REQUIREMENTS, REQUEST <br />CLARIFICATION FROM ARCHITECT/ENGINEER. <br />2. CONFORM TO THE INSTALLATION RULES AND REGULATIONS OF THE CODES AND STANDARDS <br />LISTED INCLUDING ALL SUBSEQUENTLY PUBLISHED AMENDMENTS THERETO ISSUED PRIOR TO THE <br />DATE OF THE BIDDING DOCUMENTS. <br />3. CONFORM TO THE REQUIREMENTS OF ALL LOCAL, STATE AND FEDERAL AGENCIES WHICH HAVE <br />AUTHORITY OVER THIS PROJECT. <br />4. COMPLY WITH THE APPLICABLE EDITION OF THE FOLLOWING CODES AND STANDARDS THAT <br />HAVE BEEN ADOPTED BY AND ARE ENFORCED BY THE AUTHORITY HAVING JURISDICTION: <br />a. INTERNATIONAL BUILDING CODE. <br />b. INTERNATIONAL ENERGY CONSERVATION CODE <br />c. INTERNATIONAL MECHANICAL CODE <br />d. NATIONAL ELECTRICAL CODE <br />e. INTERNATIONAL FIRE CODE <br />f. LIFE SAFETY CODE, NFPA 101 <br />g. AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES <br />h. ALL LOCAL CODES AND ORDINANCES ADOPTED AND ENFORCED BY THE AUTHORITY HAVING <br />JURISDICTION. <br />F. REFERENCED STANDARDS: <br />1. ALL EQUIPMENT, APPARATUS, MATERIALS AND SYSTEMS SHALL BE RATED, TESTED, FABRICATED <br />AND INSTALLED IN ACCORDANCE WITH THE APPLICABLE INDUSTRY STANDARDS. <br />2. ALL EQUIPMENT, APPARATUS, MATERIALS AND SYSTEMS SHALL BE LISTED AND LABELED BY A <br />NATIONALLY RECOGNIZED TESTING LABORATORY (UL, ETL, ETC) <br />ELECTRICAL CONTRACT DOCUMENTS <br />A. THE ELECTRICAL DRAWINGS (DRAWINGS) AND THE SPECIFICATIONS SHALL TOGETHER FORM A <br />SET OF CONTRACT DOCUMENTS FOR THE ELECTRICAL WORK. NEITHER THE DRAWINGS OR THE <br />SPECIFICATIONS SHALL BE COMPLETE WITHOUT THE OTHER. ANY ITEM SHOWN ONLY ON THE <br />DRAWINGS OR SPECIFIED ONLY IN THE SPECIFICATIONS SHALL BE CONSIDERED AS IF SHOWN AND <br />SPECIFIED IN BOTH. <br />B. ELECTRICAL DRAWINGS AND SPECIFICATIONS: COMPLY WITH THE FOLLOWING REQUIREMENTS: <br />1. CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL DRAWINGS AND SPECIFICATIONS <br />WITHIN THE CONTRACT DOCUMENTS, INCLUDING, BUT NOT NECESSARILY LIMITED TO, <br />GEOTECHNICAL, LANDSCAPE, CIVIL, ARCHITECTURAL, STRUCTURAL, FOOD SERVICE, MECHANICAL, <br />PLUMBING, TELECOMMUNICATION AND FIRE PROTECTION DRAWINGS AND SPECIFICATIONS. <br />2. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO INDICATE <br />APPROXIMATE LOCATION ONLY OF ELECTRICAL WORK. THE ACTUAL LOCATION OF ANY ELECTRICAL <br />WORK SHALL NOT INTERFERE WITH THE LOCATION, CLEARANCES, ETC. REQUIRED BY THE WORK OF <br />OTHER TRADES. <br />3. PRIOR TO ROUGH-IN, CONTRACTOR SHALL COORDINATE ALL DEVICE LOCATIONS WITH THE <br />ARCHITECTURAL WALL ELEVATIONS, CASEWORK/CABINETRY ELEVATIONS AND DETAILS AND THE <br />FINAL, APPROVED FOOD SERVICE SHOP DRAWINGS. <br />C. DEFINITIONS: THE FOLLOWING TERMS ARE USED ON THE ELECTRICAL DRAWINGS AND IN THE <br />SPECIFICATIONS AND SHALL BE DEFINED AS FOLLOWS: <br />1. CONTRACTOR - THE ELECTRICAL CONTRACTOR OR ANY OF THEIR SUB-CONTRACTORS. <br />2. WORK - ALL MATERIAL, LABOR, TRANSPORTATION OF THE ELECTRICAL CONTRACTOR OR ANY OF <br />THEIR SUB-CONTRACTORS. <br />3. FURNISH - PURCHASE, SUBMIT FOR REVIEW AND APPROVAL, COORDINATE WITH THE CONTRACT <br />DOCUMENTS AND DELIVER TO THE PROJECT SITE IN NEW, UNDAMAGED CONDITION, STORE AS <br />DIRECTED, PROTECT FROM DAMAGE DURING STORAGE. <br />4. INSTALL - INSTALL IN PLACE, MAKE READY FOR CONNECTION TO THE REQUIRED SERVICE. <br />5. CONNECT - CONNECT TO THE REQUIRED SERVICE AS REQUIRED FOR PROPER OPERATION, <br />TEST FOR PROPER OPERATION AND FUNCTIONALITY IN ACCORDANCE WITH MANUFACTURER'S <br />REQUIREMENTS AND REQUIREMENTS SPECIFIED WITHIN THESE SPECIFICATIONS AND TURN OVER <br />TO THE OWNER IN FULL OPERATING CONDITION. <br />6. PROVIDE - FURNISH, INSTALL AND CONNECT AS DEFINED HEREIN FOR A COMPLETE, <br />FUNCTIONAL AND CODE COMPLIANT INSTALLATION READY FOR INTENDED USE. <br />7. FINISHED SPACE - SPACES HAVING WALLS PAINTED OR FINISHED WITH WALL COVERING, LAY-IN <br />OR DRYWALL CEILINGS, AND FINISHED FLOORING MATERIALS. EXAMPLES OF FINISHED SPACES <br />INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, ALL SPACES IN A DWELLING UNIT, OFFICES, <br />LOBBIES, CORRIDORS, TOILET ROOMS, ETC. <br />8. UNFINISHED SPACES - SPACES WITH UNFINISHED WALLS AND FLOORS AND TYPICALLY ARE NOT <br />EQUIPPED WITH A CEILING. EXAMPLES INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, <br />MECHANICAL ROOMS, ELECTRICAL ROOMS, SERVICE AREAS, ETC. <br />9. SHALL - ACTION THAT IS REQUIRED WITHOUT OPTION OR QUALIFICATION. <br />10. REMOVE - DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM <br />OFF SITE UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND RE-INSTALLED. <br />11. REMOVE AND SALVAGE - CAREFULLY DETACH FROM EXISTING CONSTRUCTION IN A MANNER <br />TO PREVENT DAMAGE AND DELIVER TO OWNER READY FOR RE-USE. <br />12. REMOVE AND REINSTALL - DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE FOR RE- <br />USE, RE-INSTALL AND RECONNECT WHERE INDICATED SUCH THAT THE RE-INSTALLED ITEM IS <br />FULLY OPERATIONAL. <br />13. EXISTING TO REMAIN - EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE <br />PERMANENTLY REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, REMOVED <br />AND SALVAGED OR REMOVED AND RE-INSTALLED. <br />RECORD DOCUMENTS <br />A. DURING THE PROGRESS OF THE WORK, CONTRACTOR SHALL MAINTAIN A CURRENT (DAILY) AS- <br />BUILT SET OF THE DRAWINGS AND SPECIFICATIONS, INDICATING THEREON ALL WORK INSTALLED AT <br />VARIANCE WITH SUCH CONTRACT DOCUMENTS INCLUDING, WITHOUT LIMITATION, WORK COVERED BY <br />ADDENDA, FIELD WORK ORDERS, CHANGE ORDERS, AND ENGINEERS <br />B. CONTRACTOR SHALL PROVIDE THE TENANT WITH THE FINAL AS-BUILT SET OF DRAWINGS AT THE <br />COMPLETION OF THE WORK. <br />COORDINATION WITH LANDLORD AND UTILITY COMPANIES <br />A. PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL COORDINATE THE WORK OF THIS <br />CONTRACT WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE AND AUTHORIZED <br />REPRESENTATIVES OF EACH SERVING UTILITY THAT WILL PROVIDE SERVICE TO THIS SITE, INCLUDING <br />BUT NOT NECESSARILY LIMITED TO, ELECTRIC, TELEPHONE AND CABLE/SATELLITE TV SERVICE <br />PROVIDERS. <br />B. CONTRACTOR SHALL MEET WITH AUTHORIZED REPRESENTATIVES OF THE LANDLORD AND EACH <br />UTILITY TO DISCUSS LANDLORD UTILITY COMPANY SCOPE OF WORK, CONTRACTOR SCOPE OF WORK, <br />POINT OF SERVICE PICK-UP, DETAILS REGARDING SYSTEM INTERFACE, UTILITY COMPANY STANDARDS <br />TO BE COMPLIED WITH, ETC. <br />COORDINATION WITH OTHER TRADES <br />A. ELECTRICAL WORK SHALL BE INSTALLED SO AS TO NOT CONFLICT WITH THE WORK OF OTHER <br />TRADES. <br />B. SET ALL SLEEVES AND CUT AND PATCH ALL MISCELLANEOUS HOLES NECESSARY FOR THE <br />CONVENIENT AND PROPER INSTALLATION OF THE WORK. <br />C. CONFER WITH THE OTHER CONTRACTORS REGARDING THE LOCATION AND SIZE OF PIPES, <br />EQUIPMENT, DUCTS, OPENINGS AND SPECIAL ARCHITECTURAL TREATMENTS IN ORDER THAT THERE <br />MAY BE NO INTERFERENCES BETWEEN THE INSTALLATION OR THE PROGRESS OF THE WORK OF ANY <br />CONTRACTOR ON THE PROJECT. <br />D. ALL LINE VOLTAGE WIRING AND FINAL CONNECTIONS TO COMPLETE MECHANICAL SYSTEMS SHALL <br />BE PROVIDED BY THE ELECTRICAL CONTRACTOR. <br />E. PROVIDE FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT FURNISHED/PROVIDED BY OTHERS, <br />(HVAC EQUIPMENT, PLUMBING EQUIPMENT, COMMERCIAL KITCHEN EQUIPMENT, ETC. <br />F. COORDINATE THE NEMA CONFIGURATION OF THE RECEPTACLE TO BE PROVIDED WITH THE NEMA <br />PLUG CONFIGURATION OF THE CORD/PLUG ASSEMBLY FURNISHED WITH THE EQUIPMENT TO BE <br />INSTALLED. PROVIDE RECEPTACLES HAVING A NEMA CONFIGURATION THAT MATCHES THE NEMA <br />CONFIGURATION OF THE PLUG ON THE EQUIPMENT. <br />G. PROVIDE FINAL COORDINATION OF AVAILABLE POWER (VOLTAGE/PHASE) WITH OTHER TRADES <br />PRIOR TO THEIR ORDERING OF EQUIPMENT. <br />H. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL <br />WORK TO BE PROVIDED ASSOCIATED WITH MECHANICAL EQUIPMENT. <br />I. WHERE ELECTRICAL WORK (CONDUIT BOXES, RECEPTACLES, DISCONNECT SWITCHES, ETC.) ARE <br />SECURED DIRECTLY TO THE HOUSING OF MECHANICAL EQUIPMENT, THEY SHALL BE INSTALLED ON A <br />PORTION OF THE EQUIPMENT HOUSING NOT REQUIRED TO BE REMOVED FOR ROUTINE <br />MAINTENANCE. PRIOR TO INSTALLATION, COORDINATE ALL ELECTRICAL WORK AT MECHANICAL <br />EQUIPMENT WITH MECHANICAL CONTRACTOR. <br />FIRE STOPPING <br />A. PROVIDE FIRE STOPPING FOR PENETRATIONS BY CONDUIT OR CABLES AND OTHER EQUIPMENT <br />THROUGH FIRE-RATED VERTICAL BARRIERS (WALLS AND PARTITIONS), HORIZONTAL BARRIERS <br />(FLOOR/CEILING ASSEMBLIES) AND VERTICAL SHAFT WALLS AND PARTITIONS. <br />B. FIRESTOP SYSTEM INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF ATME E 814 OR UL <br />1479 TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO OR GREATER THAN THAT OF THE <br />CONSTRUCTION BEING PENETRATED. <br />SEISMIC RESTRAINT <br />A. PROVIDE SEISMIC RESTRAINT FOR ELECTRICAL WORK AND SYSTEMS AND EQUIPMENT IN STRICT <br />ACCORDANCE WITH THE APPLICABLE BUILDING CODE AND THE REQUIREMENTS OF THE AUTHORITY <br />HAVING JURISDICTION. <br />B. SUBMIT ALL REQUIRED DETAILS TO THE AUTHORITY HAVING JURISDICTION FOR REVIEW AND <br />APPROVAL. <br />CUTTING & PATCHING <br />A. PRIOR TO CORE DRILLING OR SAW CUTTING OPERATIONS, CONTRACTOR SHALL X-RAY OR GROUND <br />PENETRATING RADAR (GPR) THE EXISTING SLAB TO DETERMINE THE LOCATION OF ANY EXISTING <br />UTILITIES, STRUCTURAL MEMBERS. ETC. COORDINATE ALL SCANNING, CUTTING AND CORE DRILLING <br />OPERATIONS WITH GC AND LANDLORD PRIOR TO COMMENCEMENT OF WORK. <br />B. CORE-DRILL OR SAW-CUT EXISTING FLOORS, WALLS, ROOF, ETC., AS REQUIRED FOR THE <br />INSTALLATION OF THE ELECTRICAL WORK. EXISTING UTILITIES AND STRUCTURAL COMPONENTS, <br />INCLUDING BUT NOT NECESSARILY LIMITED TO, COLUMNS, BEAMS, GIRDERS, PLATES OR JOISTS SHALL <br />NOT BE CUT. <br />C. PATCH SURROUNDING AREAS FLUSH WITH ADJACENT SURFACES AND PREPARE TO RECEIVE <br />SPECIFIED FINISHES. <br />D. PATCH AND REPAIR ROOF TO MATCH EXISTING ROOFING SYSTEM. ALL ROOF WORK SHALL BE <br />PERFORMED TO MEET THE WARRANTY REQUIREMENTS OF THE EXISTING ROOFING SYSTEM. <br />GROUNDING <br />A. PROVIDE ELECTRICAL SYSTEM AND EQUIPMENT GROUNDING IN ACCORDANCE WITH APPLICABLE <br />N.E.C. REQUIREMENTS. <br />B. THE METALLIC CONDUIT SYSTEM SHALL BE GROUNDED AND BONDED TO FORM AN EQUIPMENT <br />GROUNDING CONDUCTOR. <br />C. PROVIDE AN INSULATED EQUIPMENT GROUND CONDUCTOR WITHIN ALL FEEDERS AND BRANCH <br />CIRCUITS. THIS EQUIPMENT GROUND CONDUCTOR SHALL BE IN ADDITION TO THE EQUIPMENT GROUND <br />CONDUCTOR FORMED BY THE METALLIC CONDUIT SYSTEM. <br />EQUIPMENT IDENTIFICATION <br />A. PROVIDE EQUIPMENT LABELS ON PANELBOARDS, DISCONNECT SWITCHES, CONTACTORS, <br />TRANSFORMERS, CONTROLS, ETC. EQUIPMENT LABELS SHALL BE ENGRAVED PHENOLIC RESIN <br />NAMEPLATES ATTACHED TO ENCLOSURE WITH MECHANICAL FASTENERS. SELF-ADHESIVE NAMEPLATES <br />ARE NOT ACCEPTABLE. LETTERING SHALL BE 1/2" HIGH, BLACK TEXT ON WHITE BACKGROUND. <br />B. ENGRAVED NAMEPLATES ATTACHED TO COMPONENTS SHALL IDENTIFY THE EQUIPMENT <br />DESIGNATION, NAME OF THE "UPSTREAM" POWER SOURCE (AS APPLICABLE), VOLTAGE AND PHASE. <br />CONDUCTORS <br />A. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, #12 AWG MINIMUM. <br />B. CONDUCTORS #12 AND #10 AWG SHALL BE SOLID; #8 AWG AND LARGER SHALL BE STRANDED. <br />C. THE USE OF ALUMINUM CONDUCTORS IS NOT ACCEPTABLE. <br />D. EXPOSED, INTERIOR FEEDERS: TYPE THHN-THWN, SINGLE CONDUCTORS IN CONDUIT. <br />E. FEEDERS INSTALLED CONCEALED IN CEILINGS, WALLS, PARTITIONS: TYPE THHN-THWN, SINGLE <br />CONDUCTORS IN CONDUIT. <br />F. FEEDERS INSTALLED CONCEALED IN CONCRETE, BELOW SLABS-ON-GRADE AND <br />UNDERGROUND: TYPE THHN-THWN, SINGLE CONDUCTORS IN PVC CONDUIT. <br />G. EXPOSED, INTERIOR, BRANCH CIRCUITS: TYPE THHN-THW N, SINGLE CONDUCTORS IN CONDUIT. <br />H. BRANCH CIRCUITS CONCEALED IN EXISTING AND NEW CEILINGS, WALLS, AND PARTITIONS: <br />TYPE THHN-THWN, SINGLE CONDUCTORS IN CONDUIT. <br />I. BRANCH CIRCUITS CONCEALED BELOW SLABS-ON-GRADE, AND UNDERGROUND: TYPE THHN- <br />THWN, SINGLE CONDUCTORS IN CONDUIT. <br />J. ACCEPTABLE MANUFACTURERS FOR CONDUCTORS: GENERAL CABLE COMPANY, CAROL, <br />ANACONDA, ROME, SOUTHWIRE. <br />K. CLASS 1 CONTROL CIRCUITS: TYPE THHN-THWN, IN CONDUIT. <br />L. CLASS 2 CONTROL CIRCUITS: POWER-LIMITED PLENUM RATED CABLE, CONCEALED IN BUILDING <br />FINISHES. <br />M. THE USE OF NON-METALLIC-SHEATHED CABLE (TYPE NM) AND ARMORED CABLE (TYPE AC OR BX) <br />IS NOT ACCEPTABLE <br />N. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCH LOCK FOR #8 AWG AND SMALLER, THOMAS <br />AND BETTS LOCK-TITE FOR #6 AND LARGER. <br />O. PROVIDE #10 AWG CONDUCTORS FOR BRANCH CIRCUITS HAVING A CONDUCTOR LENGTH <br />LONGER THAN 75 FEET. <br />P. SIZE OF CONDUCTORS AND CABLES INDICATED OR SPECIFIED ARE IN AMERICAN WIRE GAGE <br />(AWG - BROWN AND SHARPE). <br />Q. INSTALL ALL WIRING IN APPROVED RACEWAY AND ENCLOSURES, EXCEPT WHERE SPECIFIED OR <br />INDICATED, FOR LOW-VOLTAGE WIRING OR, WHERE TYPE MC CABLE IS INDICATED, SPECIFIED AS <br />ACCEPTABLE, OR BOTH. <br />R. SUPPORT ALL CONDUCTORS AND CABLES IN VERTICAL INSTALLATIONS, AS REQUIRED BY <br />NFPA-70, BY INSTALLING CABLE SUPPORTS OR PLUG-TYPE CONDUIT RISER SUPPORTS, OR WIRE- <br />MESH SAFETY GRIPS. <br />S. INSTALL ALL CONDUCTORS AND CABLE IN RACEWAYS CONTINUOUS WITHOUT TAPS OR SPLICES. <br />SPLICE OR TAP ONLY IN APPROVED BOXES AND ENCLOSURES WITH APPROVED SOLDERLESS <br />CONNECTORS, OR CRIMP CONNECTORS AND TERMINAL BLOCKS FOR CONTROL WIRING, AND KEEP <br />TO THE MINIMUM REQUIRED. INSULATE ALL SPLICES, TAPS, AND JOINTS AS REQUIRED BY CODE. <br />T. ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS: DESIGNED, PROPERLY <br />SIZED, AND UL LISTED FOR THE SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND <br />INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, USING THE <br />MANUFACTURER'S RECOMMENDED TOOLS. <br />U. WHERE WIRING IS INDICATED AS INSTALLED, BUT THE CONNECTION IS INDICATED "FUTURE" OR <br />"BY OTHER DIVISION, TRADES, OR CONTRACTS", LEAVE A MINIMUM OF 3' FOOT "PIGTAIL" AT THE BOX, <br />TAPE THE ENDS OF CONDUCTORS, AND COVER THE BOX. <br />V. VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 3 PERCENT. <br />W. WHEN NEW CONDUCTORS ARE CONNECTED TO EXISTING CONDUCTORS, THE NEW <br />CONDUCTORS SHALL BE OF THE SAME AWG, CONDUCTOR MATERIAL, INSULATION TYPE <br />TEMPERATURE RATING,. ETC. AS THE EXISTING CONDUCTORS TO WHICH BEING CONNECTED. <br />I. PULLBOXES AND JUNCTION BOXES THAT ARE CUSTOM FABRICATED FOR THE APPLICATION <br />SHALL BE FABRICATED BY A SHOP/FACILITY THAT IS CERTIFIED BY A NRTL FOR THE FABRICATION <br />OF SUCH ENCLOSURES. <br />J. NEW OUTLET BOXES INSTALLED WITHIN NEW OR EXISTING STUD WALL CONSTRUCTION SHALL <br />BE MOUNTED TO A STUD OR MOUNTED IN A BRACKET THAT SPANS STUD-TO-STUD, CADDY TSGB <br />BRACKET OR APPROVED EQUAL. THE USE OF "OLD WORK" TYPE BOXES THAT. SECURE ONLY TO <br />THE DRYWALL ARE NOT ACCEPTABLE. <br />K. ACCEPTABLE MANUFACTURERS FOR BOXES: APPLETON, STEEL CITY, RACO. <br />PANELBOARDS <br />A. CIRCUIT BREAKERS SHALL HAVE A MINIMUM AMPERE INTERRUPTING CAPACITY (AIC) OF 10,000 <br />AMPERES FOR 120/208V SYSTEMS, 14,000 FOR 277/480V SYSTEMS <br />B. WHERE THE POWER SYSTEM STUDY IDENTIFIES AVAILABLE FAULT CURRENT VALUES AT <br />EXISTING AND NEW PANELS THAT ARE HIGHER THAN THE MINIMUM AIC RATINGS SPECIFIED <br />HEREIN, PROVIDE CIRCUIT BREAKERS IN THE PANELS THAT HAVE AIC RATINGS GREATER THAN THE <br />AVAILABLE FAULT CURRENT AT THE PANEL AS DETERMINED BY THE POWER SYSTEM STUDY. <br />C. PROVIDE NEW CIRCUIT DIRECTORIES WITHIN NEW AND EXISTING PANELS TO REFLECT THE <br />WORK OF THIS CONTRACT. DIRECTORY SHALL BE TYPEWRITTEN OR COMPUTER GENERATED. <br />HANDWRITTEN CIRCUIT DIRECTORIES ARE NOT ACCEPTABLE. <br />D. UTILIZE FINAL, OWNER ASSIGNED ROOM NAMES AND NUMBERS TO IDENTIFY SPACES WITHIN <br />THE CIRCUIT DIRECTORIES. COMPLY WITH NEC 408.4 WHEN IDENTIFYING CIRCUITS IN CIRCUIT <br />DIRECTORIES. <br />E. PANEL CIRCUITS SHALL BE CONFIGURED SUCH THAT THE LOAD IS DISTRIBUTED EVENLY <br />ACROSS ALL THREE PHASES TO WITHIN 10% IN ACCORDANCE WITH N.E.C. REQUIREMENTS. <br />F. ALL NEW AND EXISTING PANELBOARDS SHALL BE LABELED TO IDENTIFY THE AMOUNT OF FAULT <br />CURRENT AVAILABLE AT THE PANEL AS DETERMINED BY THE POWER SYSTEM STUDY TO BE <br />PERFORMED. LABEL SHALL BE MACHINE PRINTED, BLACK TEXT ON CLEAR, SELF ADHESIVE TAPE. <br />INSTALL LABEL ADJACENT TO PANELBOARDS ENGRAVED NAMEPLATE. <br />G. ALL NEW AND EXISTING PANELBOARDS SHALL BE LABELED TO IDENTIFY THE ARC FLASH <br />HAZARD CHARACTERISTICS AT THE PANEL AS DETERMINED BY THE POWER SYSTEM STUDY TO BE <br />PERFORMED. <br />H. ALL “SPARE” CIRCUIT BREAKERS SHALL BE SET TO THE “OFF” POSITION. <br />I. PROVIDE HANDLE TIES ON ALL MULTI-WIRE BRANCH CIRCUITS IN ACCORDANCE WITH NEC <br />210.4(B) <br />J. WHEN NEW CIRCUIT BREAKERS ARE ADDED TO AN EXISTING PANEL, THE NEW CIRCUIT <br />BREAKERS SHALL BE OF THE SAME MANUFACTURE AS THE EXISTING PANEL, SHALL BE OF A <br />'LETTER TYPE' COMPATIBLE WITH THE EXISTING PANEL SUCH THAT THE UL LISTING OF THE <br />EXISTING PANEL IS MAINTAINED AND SHALL HAVE AN AIC RATING EQUAL TO OR GREATER THAN <br />THE AIC RATING OF THE EXISTING OVERCURRENT PROTECTIVE DEVICES WITHIN THE EXISTING <br />PANEL. <br />C. THE COVERS OF ALL OUTLET AND JUNCTION BOXES INSTALLED ABOVE CEILINGS AND INSTALLED <br />EXPOSED IN UNFINISHED SPACES SHALL BE LABELED TO IDENTIFY THE SERVING PANEL, VOLTAGE, <br />PHASE AND CIRCUIT NUMBERS CONTAINED WITHIN THE BOX. LABEL SHALL BE LEGIBLY HANDWRITTEN <br />WITH BLACK, FELT TIP PERMANENT MARKER. <br />D. THE COVER PLATES OF ALL WIRING DEVICES SHALL BE LABELED TO IDENTIFY THE SERVING PANEL <br />AND THE CIRCUITS SERVING THE DEVICE. LABELS SHALL BE MACHINE PRINTED, BLACK TEXT ON A <br />CLEAR, SELF ADHESIVE LABEL. <br />CONDUIT AND FITTINGS <br />A. ALL INTERIOR AND EXTERIOR CONDUITS SHALL BE INSTALLED AND SUPPORTED IN ACCORDANCE <br />WITH N.E.C. REQUIREMENTS. <br />B. MINIMUM CONDUIT SIZE SHALL BE ¾” TRADE SIZE. SWITCH LEGS SHALL BE ½” TRADE SIZE. <br />C. WITHIN INTERIOR FINISHED SPACES, ALL CONDUIT SHALL BE INSTALLED CONCEALED WITHIN NEW <br />AND EXISTING WALLS AND ABOVE NEW AND EXISTING CEILINGS. <br />D. CONDUIT INSTALLED WITHIN THE INTERIOR OF THE BUILDING SHALL BE GALVANIZED ELECTRICAL <br />METALLIC TUBING (EMT). CONDUIT FITTINGS FOR INDOOR EMT CONDUITS SHALL BE CAST METAL, <br />COMPRESSION TYPE. <br />E. EMT SHALL BE USED FOR INTERIOR FEEDERS AND BRANCH CIRCUITS INSTALLED EXPOSED IN <br />UNFINISHED SPACES, CONCEALED ABOVE NEW OR EXISTING CEILINGS OR CONCEALED WITHIN EXISTING <br />AND NEW INTERIOR PARTITIONS. <br />F. CONDUITS INSTALLED EXPOSED ON THE EXTERIOR OF THE BUILDING SHALL BE GALVANIZED RIGID <br />STEEL. FITTINGS SHALL BE THREADED TYPE. <br />G. CONDUITS INSTALLED UNDER SLAB ON GRADE CONSTRUCTION SHALL BE RIGID NON-METALLIC <br />(RNC), SCHEDULE 40 PVC. RNC COMPLYING WITH NEMA TC 2 AND UL 651 UNLESS OTHERWISE <br />INDICATED. FITTINGS FOR RIGID NON-METALLIC CONDUIT SHALL COMPLY WITH NEMA TC 3; MATCH TO <br />CONDUIT TYPE AND MATERIAL. <br />H. PROVIDE CONDUIT EXPANSION FITTINGS IN ALL CONDUIT RUNS THAT EXTEND ACROSS BUILDING <br />EXPANSION JOINTS AND WHERE MOVEMENT MAY BE ENCOUNTERED. <br />I. CONDUIT SHALL BE SUPPORTED FROM STRUCTURE ONLY. <br />J. PVC CONDUIT SHALL ONLY BE USED BELOW GRADE. <br />K. PROVIDE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO VIBRATING EQUIPMENT WITHIN INTERIOR <br />DRY LOCATIONS. MAXIMUM CONDUIT LENGTH SHALL BE 36 INCHES. <br />L. PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO VIBRATING EQUIPMENT IN <br />WET OR OUTDOOR LOCATIONS. MAXIMUM CONDUIT LENGTH SHALL BE 36 INCHES. <br />M. PROVIDE FLEXIBLE METAL CONDUIT FOR FINAL CONNECTIONS TO RECESSED LIGHT FIXTURES <br />(FIXTURE WHIPS). MAXIMUM CONDUIT LENGTH SHALL BE 72 INCHES. <br />N. PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT FOR FINAL ELECTRICAL CONNECTIONS TO FOOD <br />SERVICE EQUIPMENT. <br />O. CONDUITS THAT EXTEND UP TO THE ROOF LEVEL TO SERVE ROOF MOUNTED MECHANICAL <br />EQUIPMENT INSTALLED ON A CURB SHALL BE ROUTED WITHIN THE EQUIPMENT CURB. COORDINATE <br />ELECTRICAL WORK WITH MECHANICAL EQUIPMENT INSTALLER. <br />P. PROVIDE CONDUIT SEALING FITTINGS IN ALL CONDUITS THAT EXTEND FROM NON-REFRIGERATED <br />SPACES TO REFRIGERATED SPACES PER NEC 300.7(A). PROVIDE EXPANSION JOINTS FOR CONDUIT AS <br />REQUIRED TO COMPENSATE FOR THERMAL EXPANSION AND CONTRACTION. <br />Q. ALL CONDUITS INSTALLED IN ASSOCIATION WITH THE WALK-IN COOLER FREEZER SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE WALK-IN MANUFACTURERS RECOMMENDATIONS AND <br />REQUIREMENTS. COORDINATE ALL CONDUIT INSTALLATION WITH WALK-IN EQUIPMENT INSTALLER. <br />R. ACCEPTABLE MANUFACTURERS FOR GALVANIZED RIGID CONDUIT, EMT, FLEXIBLE METAL CONDUITS <br />AND LIQUID-TIGHT FLEXIBLE METAL CONDUITS SHALL BE ALLIED, REPUBLIC, WHEATLAND, ELECTRI-FLEX <br />AND ANACONDA. <br />S. ACCEPTABLE MANUFACTURERS FOR CONDUIT FITTINGS SHALL BE THOMAS AND BETTS OR <br />APPROVED EQUAL. <br />TYPE MC CABLE <br />A. A.TYPE MC CABLE: 600V, UNJACKETED: ANSI E119 AND E814, UL STANDARDS 44 OR 83 (AS <br />APPLICABLE), AND 1569, NFPA 70 ARTICLE 330; ALUMINUM OR GALVANIZED STEEL INTERLOCKED <br />ARMOR; THHM- OR XHHW-INSULATED CONDUCTORS; COLOR CODE: ICEA METHOD 1, WITH GREEN <br />INSULATED GROUNDING CONDUCTOR. <br />B. USES PERMITTED <br />B.1.IN LIEU OF FLEXIBLE CONDUIT AND WIRING FROM LIGHT FIXTURES IN ACCESSIBLE CEILINGS TO <br />JUNCTION BOXES (ATTACHED TO BUILDING STRUCTURE) ABOVE THE CEILING. PROVIDE CABLE <br />WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5' <br />FOOT RADIUS OF ITS INSTALLED LOCATION, BUT NOT EXCEEDING 6' FEET IN UNSUPPORTED <br />LENGTHS. <br />B.2.FOR VERTICAL DROPS IN STUD WALLS. <br />C. USES NOT PERMITTED: <br />C.1.HOMERUNS TO PANELSBOARDS. <br />C.2.WHERE EXPOSED TO VIEW. <br />C.3.WHERE EXPOSED TO DAMAGE. <br />C.4.HAZARDOUS LOCATIONS. <br />C.5.WET LOCATIONS <br />C.6.INSTALLED HORIZONTALLY WITHIN STUD WALL <br />C.7.WHEN RESTRICTED OTHERWISE ABOVE, AND WHEN SPECIFICALLY DISALLOWED BY THE LOCAL <br />AHJ, OWNER OR BOTH. <br />CONDUCTOR COLOR CODING <br />A. PROVIDE COLOR CODING SYSTEM AS LISTED BELOW FOR ALL FEEDERS AND BRANCH CIRCUITS <br />AND USED AS A BASIS FOR BALANCING LOAD ON PANELS, AND TO BE PHASE IDENTIFICATION. <br />B. COLOR CODING FOR CONDUCTOR #12 AWG THROUGH #6 AWG SHALL CONSIST OF COLOR <br />CODED THERMOPLASTIC INSULATION OF THE COLORS SPECIFIED HEREIN. <br />C. COLOR CODING FOR CONDUCTORS #8 AWG AND LARGER SHALL BE FIELD APPLIED SELF <br />ADHESIVE TAPE OF THE COLOR SPECIFIED HEREIN FOR THE PARTICULAR PHASE. <br />D. 120/208V: PHASE A--BLACK, PHASE B--RED, PHASE C--BLUE, NEUTRAL--WHITE, EQUIPMENT <br />GROUND--GREEN, ISOLATED GROUND--GREEN WITH DISTINCTIVE WHITE OR YELLOW MARKINGS. <br />BOXES AND FITTINGS <br />A. ALL OUTLET BOXES SHALL BE UL LISTED AND LABELED FOR USE IN THE SPACE THEY OCCUPY <br />AND THE PURPOSE THEY SERVE. <br />B. SHEET METAL OUTLET AND DEVICE BOXES FOR DRY, INTERIOR APPLICATIONS: COMPLY WITH <br />NEMA OS 1 AND UL 514A. <br />C. CAST-METAL OUTLET AND DEVICE BOXES FOR EXTERIOR APPLICATIONS: COMPLY WITH <br />NEMA FB 1, FERROUS ALLOY, TYPE FS OR FD, WITH GASKETED COVER. <br />D. OUTLET BOXES INSTALLED WITHIN FIRE RATED ASSEMBLIES SHALL HAVE A FIRE RATING EQUAL <br />TO OR GREATER THAN THE RATING OF THE WALL IN WHICH IT IS INSTALLED. <br />E. OUTLET BOXES SHALL BE 4 INCHES SQUARE BY 2 1/8 INCHES DEEP , EXCEPT FOR 2" PARTITIONS <br />SHALL BE AT LEAST 1-1/2" DEEP. <br />F. OUTLET BOXES FOR VOICE AND DATA DEVICES SHALL BE 4 11/16 INCHES SQUARE BY 2 1/8 <br />INCHES DEEP. <br />G. ALL PULLBOXES SHALL BE CONSTRUCTED OF GALVANIZED STEEL, OF METAL GAUGE AND <br />PHYSICAL SIZE AS REQUIRED BY THE N.E.C. FOR THE NUMBER AND SIZE OF CONDUITS AND <br />CONDUCTORS ASSOCIATED WITH THE PULLBOX. <br />H. FIXTURE OUTLET BOXES IN/OR ON CEILINGS SHALL NOT BE LESS THAN 1-1/2" DEEP OR LESS <br />THAN 4" SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH <br />3/8" FIXTURE STUDS FASTENED THROUGH THE BOTTOM OF THE BOX WITH FOUR BOLTS. <br />MATCH THE WIRING DEVICE. <br />20 <br />2 <br />4 <br /> <br /> <br />D <br />X <br />U <br />- <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />© <br />SEAL <br />PROJECT TEAM <br />MUNICIPAL APPROVAL STAMP <br />THESE DRAWINGS ARE CONFIDENTIAL AND SHALL BE IN THE <br />POSSESSION OF AUTHORIZED INDIVIDUALS ONLY. THESE DOCUMENTS <br />ARE THE EXCLUSIVE PROPERTY OF DxU ARCHITECTS AND SHALL NOT <br />BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION <br />SHEET TITLE & NUMBER <br />CLIENT <br />PROJECT <br />PROJECT NUMBER: <br />APPROVED BY: KKDRAWN BY: YP <br />NO. DATE ISSUE <br />OWNER <br />METHOD ART CORP <br />CONTACT: BRYNN MINER <br />(P) 714.599.1112 <br />EMAIL: MYCAVALIERS@HOTMAIL.COM <br />11-05-25 <br />E001 <br />ELECTRICAL <br />SPECIFICATONS <br />7-ELEVEN WIN <br />COFFEE <br />1700 E DYER ROAD <br />SANTA ANA, CA. 92705 <br />STORE# 33155 <br />24-675 <br />Project Status