HEAT PUMP WATER HEATER NOTES:
<br />·40 GALLON HEAT PUMP WATER HEATER TO BE
<br />INSTALLED PER MANUFACTURER INSTRUCTIONS.
<br />·WATER HEATER MUST BE NORTHWEST ENERGY
<br />EFFICIENCY ALLIANCE (NEEA) RATED HEAT PUMP
<br />WATER HEATER; SPECIFIC BRAND/MODEL, OR
<br />EQUIVALENT, MUST BE INSTALLED
<br />·METAL ENCLOSURE OR SIMILAR PROTECTION MUST BE
<br />INSTALLED.
<br />RECESSED DOWN LIGHT FIXTURE HIGH EFFICACY (CFL OR LED LIGHTING)
<br />CEILING LIGHT FIXTURE HIGH EFFICACY (CFL OR LED LIGHTING)
<br />ARC FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET
<br />GROUND FAULT INTERRUPTED DUPLEX OUTLET
<br />WEATHERPROOF OUTLET - G.F.C.I.
<br />WP/
<br />GFI
<br />GFI
<br />WALL MOUNTED W/ MOTION SENSOR AND TIMER LIGTH FIXTURE
<br />ELECTRIC / UTILITY SYMBOLS:
<br />EXHAUST FAN (MIN. 5 AIR CHANGES PER HOUR) WITH HUMIDITY CONTROL
<br />AND VACANCY IN BATHROOMS
<br />HOSE BIB AND SHUT OFF VALVEH.B.
<br />(INSTALL HIGH EFFICACY LIGHTING)
<br />CLG. FAN & LIGHT
<br />3-WAY SWITCH @ 48" HIGH
<br />HUMIDITY SENSOR @ 48" HIGH
<br />SINGLE POLE SWITCH @ 42" HIGH
<br />S
<br />S
<br />3
<br />S
<br />CARBON MANOXIDE ALARMSC.M.
<br />SLIDE DIMMER @ 48" HIGHS
<br />IONIZATION SMOKE ALARM WITH ALARM-SILENCING SWITCH HARDWIRED
<br />UL217
<br />GENERAL NOTES
<br />SMOKE ALARMS
<br />·SMOKE ALARMS SHALL BE LISTED PER UL 217, INSTALLED PER
<br />NFPA 72 AND SHALL BE CALIF. STATE FIRE MARSHALL LISTED.
<br />·SMOKE ALARMS SHALL BE INSTALLED MAINTAINED AND
<br />CONNECTED IN THE FOLLOWING LOCATIONS/MANNER:
<br />[R314.3,.4,.5]
<br />··IN EACH SLEEPING ROOM.
<br />··OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
<br />VICINITY OF THE BEDROOMS.
<br />··ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
<br />BASEMENT AND SPLIT LEVELS.
<br />··WHEN MORE THAN ONE SMOKE ALARM IS INSTALLED, THE
<br />ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A
<br />MANNER THAT THE ACTIVATION OF ONE ALARM WILL
<br />ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. THE
<br />ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER
<br />BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS
<br />CLOSED.
<br />··SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER
<br />FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED
<br />FROM COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH
<br />BATTERY BACKUP.
<br />··SMOKE ALARMS SHALL BE PROVIDED IN ALL NEW
<br />CONSTRUCTION LOCATED IN EACH SLEEPING ROOM, OUTSIDE
<br />EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY
<br />OF THE BEDROOMS, AND AT EACH ADDITIONAL FLOOR OR
<br />BASEMENT LEVEL. [CRC R314.3]
<br />··SMOKE ALARMS NOT INSTALLED A MINIMUM OF 20 FEET
<br />HORIZONTAL DISTANCE FROM COOKING EQUIPMENT.
<br />MONOXIDE ALARM REQUIREMENTS:
<br />·FOR DWELLING UNIT CONSTRUCTION HAVING AN ATTACHED
<br />GARAGE OR FUEL-BURNIG APPLIANCES, AN APPROVED CARBON
<br />MONOXIDE ALARM UL 2034/2075 SHALL BE INSTALLED,
<br />MAINTAINCE AND CONNECTED IN THE FOLLOWING
<br />LOCATIONS/MANNER:
<br />··OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE
<br />VICINITY OF THE BEDROOM(S).
<br />··ON EVERY LEVEL OF A DWELLING UNIT INCLUDING
<br />BASEMENTS.
<br />··WHERE MORE THAN ONE CO ALARM IS INSTALLED, THE
<br />ALARM SHALL BE INTERCONNECTED IN A MANNER THAT
<br />ACTIVATION OF ONE ALARM SHALL ACTIVATED ALL OF THE
<br />ALARMS.
<br />·IN EXISTING DWELLINGS WHERE WHERE A PERMIT FOR
<br />ALTERATIONS, REPAIRS OR ADDITIONS EXCEED $1000 CO
<br />ALARMS SHALL BE INSTALLED, MAINTAINED AND CONNECTED IN
<br />THE FOLLOWING LOCATIONS/MANNER: [314.3.1,.4,.6]
<br />··THE DWELLING SHALL BE EQUIPPED WITH CO ALARMS
<br />LOCATED AS REQUIRED FOR NEW CONSTRUCTION.
<br />··CO ALARMS ARE PERMITTED TO BE SOLELY BATTERY
<br />OPERATED WHERE NO CONSTRUCTION IS TAKING PLACE.
<br />LUMINARIES AND FANS
<br />·THIS CLASSIFICATION APPLIES ONLY TO ROOMS THAT ARE NOT
<br />KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, CLOSETS,
<br />OR UTILITY ROOMS. ALL INSTALLED LUMINARIES SHALL BE
<br />EITHER BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A
<br />VACANCY SENSOR OR DIMMER.
<br />·IN SINGLE-FAMILY RESIDENCIES, ALL LUMINARIES MOUNTED TO
<br />THE BUILDING (OR TO EITHER BUILDING ON THE SAME LOT)
<br />SHALL BE HIGH EFFICACY LUMINARIES, AND SHALL BE
<br />CONTROLLED BY A MOTION SENSOR AND ALSO BY A
<br />PHOTOCONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY
<br />MANAGEMENT CONTROL SYSTEM (EMCS) (OUTDOOR CEILING
<br />FANS WITH LIGHTS)
<br />·ALL SINGLE FAMILY OUTDOOR LIGHTING SHALL BE HIGH
<br />EFFICACY AND MUST BE CONTROLLED BY A MANUEL ON & OFF
<br />SWITCH AND ONE OF THE FOLLOWING AUTOMATIC CONTROL
<br />TYPES:
<br />··PHOTOCONTROL AND MOTION SENSOR
<br />··PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL
<br />··ASTRONOMICAL TIME CLOCK CONTROL
<br />··EMCS
<br />·LUMINARIES THAT ARE RECESSED INTO CEILINGS SHALL HAVE
<br />AIRTIGHT HOUSING TO PREVENT CONDITIONED AIR ESCAPING
<br />INTO THE CAVITY OR ATTIC, OR UNCONDITIONED AIR
<br />INFILTRATING FROM THE CEILING OR ATTIC INTO THE
<br />CONDITIONED SPACE (AT-LISTED). LUMINARIES THAT ARE
<br />RECESSED INTO INSULATED CEILINGS ARE REQUIRED TO BE
<br />RATED FOR INSULATION CONTACT ("IC-RATED").
<br />·BATHROOM EXHAUST FAN TO BE RATED FOR A MINIMUM OF 50
<br />CFM AND KITCHEN EXHAUST FAN TO BE RATED FOR A MINIMUM
<br />OF 100 CFM. [CEnC 150.0(O)]
<br />··LUMINARIES THAT ARE OR CONTAIN LIGHT SOURCES THAT
<br />MEET
<br />REFERENCE JOINT
<br />APPENDIX JA8 REQUIREMENTS FOR DIMMING, AND THAT ARE NOT
<br />CONTROLLED BE
<br />OCCUPANCY SENSORS, SHALL HAVE DIMMING CONTROLS. [CEnC
<br />150.0(k)2.J].
<br />·FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO
<br />TERMINATE TO THE OUTSIDE OF THE BUILDING.
<br />RECEPTACLES AND OUTLETS
<br />·FOR A ONE-FAMILY DWELLING AND EACH UNIT OF A TWO-FAMILY
<br />DWELLING THAT IS AT GRADE LEVEL, AT LEAST ONE RECEPTACLE
<br />OUTLET ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN
<br />6'-6" ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND
<br />BACK OF THE DWELLING. ALL EXTERIOR OUTLETS SHALL BE
<br />PROTECTED BY GFCI AND BE WEATHER PROOF. [2019 CEC -
<br />SECTION 406.8].
<br />·ALL EXTERIOR OUTLETS SHALL BE GFCI (NO LONGER AN
<br />EXCEPTION FOR HEIGHT) [2019 CEC - SECTION 210.8]. IN
<br />ADDITION, THE RECEPTACLE SHALL HAVE AN ENCLOSURE THAT
<br />IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED
<br />(ATTACHMENT PLUG CAP NOT INSERTED AND RECEPTACLE
<br />COVER CLOSED). ALL 15- AND 20- AMPERE, 125- AND 250-VOLT
<br />NONLOCKING RECEPTACLES SHALL BE LISTED
<br />WEATHER-RESISTANT TYPE. [2109 CEC - SECTION 406.9].
<br />·ANY HALLWAY 10' OR MORE IN LENGTH SHALL HAVE AT LEAST
<br />ONE RECEPTACLE. SHOW RECEPTACLES ON THE PLANS. (210.52
<br />(H) CEC)
<br />·AT LEAST ONE 120-VOLT, 20 AMPERE BRANCH CIRCUIT SHALL BE
<br />PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S).
<br />SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS PER CEC
<br />210.11.
<br />·AT LEAST TWO OR MORE 20-AMP SMALL-APPLIANCE BRANCH
<br />CIRCUITS SHALL BE PROVIDED AT THE KITCHEN. [CEC
<br />210.11(C)(1)]
<br />·PROVIDE ONE 20-AMP DEDICATED BRANCH CIRCUITS TO SUPPLY
<br />LAUNDRY RECEPTACLE OUTLET(S). THIS CIRCUIT SHALL HAVE NO
<br />OTHER OUTLETS PER CEC 210.11.(C)(2).
<br />·RECEPTACLE SERVING KITCHEN COUNTERTOP SHALL NOT BE
<br />SPACED MORE THAN 4 FEET APART. [CEC 210.52(C)(1)].
<br />·ALL 15 AND 20 AMP, 125 AND 250-VOLT, NONLOCKING TYPE
<br />RECEPTACLES IN A DWELLING UNIT SHALL BE LISTED
<br />TAMPER-RESISTANT RECEPTACLE [CEC 406.12(1)] EXCEPT FOR
<br />RECEPTACLES:
<br />··LOCATED MORE THAN 5 1/2 " ABOVE THE FLOOR.
<br />··THAT ARE PART OF A LUMINAIRE OR APPLIANCE.
<br />··LOCATED WITHIN A DEDICATED SPACE FOR APPLIANCE.
<br />··REPLACEMENT NONGROUNDING TYPE.
<br />·ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH
<br />CIRCUITS SUPPLYING OUTLETS (NOT JUST RECEPTACLES) AND
<br />UTILIZATION DEVICES INSTALLED IN DWELLING UNITS (INCLUDING
<br />KITCHENS, DINING ROOMS, CLOSETS, HALLWAYS, SUNROOMS,
<br />LAUNDRY, LIVING ROOMS, DENS, BEDROOMS) SHALL BE
<br />PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER,
<br />COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF
<br />THE BRANCH CIRCUIT. CEC 210.12(A)
<br />·ELECTRICAL RECEPTACLES OUTLETS, SWITCHES, AND
<br />CONTROLS (INCLUDING CONTROLS FOR HEATING VENTILATION
<br />AND AIR CONDITIONING) INTENDED TO BE USED BY THE
<br />OCCUPANTS SHALL BE LOCATED NOT MORE THAN 48 INCHES
<br />MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS
<br />THAN 15 INCHES MEASURE FROM THE BOTTOM OF THE OUTLET
<br />BOX ABOVE THE FINISH FLOOR.
<br />ELECTRICAL BOXES
<br />·ELECTRICAL BOXES SHALL HAVE DRYWALL, PLASTER, OR
<br />PLASTERBOARD SURFACES FINISHED SO THERE WILL BE NO
<br />GAPSOR OPEN SPACES GREATER THAN 1/8" AT THE EDGE OF THE
<br />BOX PER ARTICLE 314.21 (CEC). IN WALLS OR CEILINGS BOXES
<br />SHALL BE INSTALLED SO THAT THE FRONT EDGE OF THE BOX OR
<br />PLASTER RING SHALL NOT BE RECESSED MORE THAN 1/4" FROM
<br />NON-COMBUSTIBLE FINISH SURFACE AND SHALL BE FLUSHED
<br />WITH A COMBUSTIBLE SURFACE PER ARTICLE 314.20 (CEC).
<br />·ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE- PHASE,
<br />15 - AND 20 - AMPERE OUTLETS OR DEVICES INSTALLED IN
<br />DWELLING UNIT KITCHEN, FAMILY ROOMS, DINING ROOMS, LIVING
<br />ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
<br />RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS OR
<br />SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY AN
<br />ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE LISTED
<br />TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT.
<br />·NEW BOXES USED AT LUMINARIES OR LAMPHOLDER OUTLETS IN
<br />A CEILING SHALL BE REQUIRED TO SUPPORT A LUMINAIRE
<br />WEIGHING A MINIMUM OF 50 LBS. USED AT LUMINAIRE OUTLETS IN
<br />WALLS SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE
<br />MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF
<br />THE LUMINAIRE PERMITTED, IF OTHER THAN 50 LBS. OUTLET
<br />BOXES OR SYSTEM USED AS THE SOLE SUPPORT OF CEILING
<br />FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURES AS
<br />SUITABLE FOR THIS PURPOSE. (314.27 CEC).
<br />·THE PANEL OR SUB-PANEL SHALL PROVIDE CAPACITY TO INSTALL
<br />A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND
<br />SPACE(S) RESERVED TO PERMIT INSTALLATION OF A BRANCH
<br />CIRCUIT OVERCURRENT PROTECTIVE DEVICE.
<br />·THE SERVICE PANEL OR SUB-PANEL CIRCUIT DIRECTORY SHALL
<br />IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S)
<br />RESERVED FOR FUTURE EV CHARGING AS EV CAPABLE. THE
<br />RACEWAY TERMINATION LOCATION SHALL BE PERMANENT AND
<br />VISIBLY MARKED EV CAPABLE.
<br />·LOCATION OF ELECTRICAL SERVICE PANEL MUST BE APPROVED
<br />BY EDISON
<br />ELECTRICAL NOTES:
<br />·ALL JAB COMPLIANT LIGHT SOURCES, EXCEPT THOSE IN
<br />CLOSETS LESS THAN 70 SQUARE FEET AND THOSE IN HALLWAYS
<br />SHALL BE CONTROLLED BY A VACANCY SENSOR (150(K)2J CEC).
<br />·ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES (SUCH
<br />AS LIGHTS & SWITCHES) INSTALLED IN DWELLING UNIT KITCHENS,
<br />FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
<br />LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,
<br />CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS, &
<br />AREAS SHALL BE PROVIDED WITH ARC-FAULT
<br />CIRCUIT-INTERRUPTER (AFCI) PROTECTION. SEE CEC SECTION
<br />210.12(A) FOR PERMISSIBLE MEANS OF AFCI PROTECTION (210.12
<br />CEC).
<br />· IN BATHROOMS, LAUNDRY ROOMS, AND UTILITY ROOMS, AT
<br />LEAST ONE LUMINARIES IN EACH OF THE THOSE SPACES SHALL
<br />BE CONTROLLED BY A VACANCY SENSOR (150(K)2J CEC)
<br />MECHANICAL NOTES:
<br />·CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL
<br />DISCHARGE TO A PLUMBING FIXTURE OR AN APPROVED
<br />LOCATION BY MEANS OF AN INDIRECT WASTE PIPE. CONDENSATE
<br />LINES SHALL NOT TERMINATE IN LANDSCAPE OR YARDS AREAS.
<br />(310.5 CMC).
<br />·DUCTS FOR DRYER VENTS SHALL BE A MINIMUM OF 4" IN
<br />DIAMETER. THE EXHAUST DUCT SHALL NOT EXCEED A TOTAL
<br />COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FT.
<br />INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET SHALL BE
<br />DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCEES OF TWO.
<br />(CMC 504.3.1.)
<br />·A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A
<br />MINIMUM OF 4" IN DIAMETER. THE EXHAUST DUCT SHALL NOT
<br />EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGHT
<br />OF 14', INCLUDING TWO 90 DEGREE ELBOWS. TWO FEETS SHALL
<br />BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCEES OF TWO.
<br />(504.4.2 CMC).
<br />A.504.4.1 PROVISIONS FOR MAKEUP AIR.
<br />A.A.MAKEUP AIR SHALL BE PROVIDED IN ACCORDANCE WITH THE
<br />FOLLOWING:
<br />A.B.MAKEUP AIR SHALL BE PROVIDED FOR TYPE 1 CLOTHES
<br />DRYERS IN ACCORDANCE WITH THE MANUFACTURER'S
<br />INSTRUCTIONS. [NFPA 54:10.4.3.1]. WHERE A CLOSET IS
<br />DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN
<br />OPENING OF NOT LESS THAN 100 SQUARE INCHES (0.065 M2)
<br />FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY
<br />OTHER APPROVED MEANS.
<br />133/4"11"
<br />77/8"
<br />93/8"107/8"
<br />4"
<br />80 CFM/1.0 Sones @ 0.10" SP.
<br />70 CFM @ 0.25" SP.
<br />SPECIFICATIONS
<br />LEDAK80H
<br />EXHAUST FAN WITH LIGHT
<br />·IAQ FAN
<br />CONTINUOUSLY
<br />RUNNING IS
<br />LOCATED IN
<br />BATHROOM AREA -
<br />IS A EXHAUST FAN
<br />OF 80 CFM
<br />·TWO EXHAUST FAN
<br />OF 80 CFM EA. WITH
<br />HUMIDITY CONTROL
<br />AND 5 AIR CHANGES
<br />PER HOUR MIN. SEE
<br />DETAIL ON
<br />ELECTRICAL/UTILITY
<br />SYMBOLS.
<br />·ONE EXHAUST FAN
<br />OF 100 CFM MIN. ON
<br />TOP OF THE STOVE.
<br />IAQ FAN
<br />ELECTRICAL PLAN
<br />FACTOR
<br />2
<br />QUANTITY
<br />3
<br />4
<br />5
<br />6
<br />3 x 408 SQ FT
<br />1500 X 2
<br />VOLT AMPERES
<br />1,224
<br />3,000
<br />1,500
<br />5,724
<br />3,000
<br />953
<br />1500 X 1
<br />1
<br />7 3,953
<br />General Lighting (SQFT X 3 VA/SQ FT (Table 220.12)
<br />Small Appliance Circuits (1500 VA per circuit) (NEC 220.52 (A)) (minimum 2)
<br />Laundry Circuit (1500 VA per circuit) (NEC 220.52 (B))
<br />Total General Lighting Load
<br />First 3000 VA @ 100%
<br />Net General Lighting Load (Per NEC 220.42)
<br />*Fixed Appliances
<br />Garbage Disposal
<br />Bathroom Fan (1 X 20)
<br />(VA)
<br />"General Lighting"
<br />Total General Lighting Load 5,724 - 3000 = 2,724 @ 35% =
<br />Microwave
<br />Dishwasher
<br />*Other Loads (including motors, EV charger(s), etc.)
<br />9 Electric Range (8,000VA or Nameplate)**
<br />10 Heat Pump MINI SPLIT
<br />11
<br />12
<br />Electric Dryer (5000 VA minimum)**
<br />13
<br />Electric Vehicle Charger
<br />YES NO
<br />20
<br />TOTAL 1,147
<br />8 3 or less Appliances, Total Appliance VA; 4 or more Appliances, 75% of Total Appliance VA (NEC 220.53): 1,147 x 75% =1,147
<br />YES NO
<br />3,300
<br />14
<br />15
<br />25% of largest motor (NEC 430.24)1,800
<br />Total Service Load Volt-Amperes (VA) (Add lines 7, 8, & 9, thru 16)=28,199
<br />Total Service Load Volt-Amperes 28,199 / 240-volts = 117 Amperes
<br />ELECTRICAL LOAD CALCULATIONS
<br />16
<br />Other:
<br />Heat Pump Electric Water Heater
<br />Electric Induction Oven
<br />D
<br />H
<br />MS
<br />1,127
<br />8,000
<br />5,000
<br />4,999
<br />SCALE:
<br />SHEET No:
<br />DATE:
<br />DRAWN BY:
<br />DATE SHEET:
<br />CONTENT:
<br />DATE PROJECT:
<br />OWNER:
<br />ADDRESS:
<br />A.P.N.:
<br />TITLE:
<br />REVISION DATE
<br />DATE PROJECT NO.
<br />RESPONSABLE:
<br />1
<br />2
<br />3
<br />NOTE:
<br />4
<br />5
<br />6
<br />1671 THIRD ST. SUITE 102
<br />NORCO, CA. 92680
<br />PH: (951) 407-1131
<br />ELECTRICAL
<br />PLAN
<br />ELVIRA KENNEDY
<br />E-1
<br />3/8" = 1'-0"LEGEND
<br />NEW WALL
<br />UL 2034/2075, CARBON MONOXIDE ALARMS SHALL BE
<br />INTERCONNECTED AND HARDWIRED. [CRC R315.1.1 & R315.1.2]
<br />12K
<br />MINI SPLIT
<br />HOOD VENT OVER RANGE
<br />ATTIC
<br />ACCESS
<br />30" X 30"
<br />ONE HOUR FIRE WALL
<br />MS
<br />80 CFM
<br />80 CFM
<br />100 CFM
<br />E
<br />NEW ELECTRICAL
<br />100 AMPS
<br />SUB-PANEL
<br />GFI
<br />GFI
<br />GFI
<br />GFI
<br />SS
<br />S
<br />S
<br />S SS
<br />S
<br />S S
<br />H.B.
<br />C.M.
<br />D
<br />D
<br />D
<br />H
<br />H
<br />IRMA DE LA TORRE
<br />1702 S. GARNSEY ST.
<br />SANTA ANA, CA 92707
<br />013-244-01
<br />DISCONNECTDC
<br />GFI
<br />MS
<br />S
<br />VACANCY SENSOR @ 48" HIGHS
<br />V
<br />S
<br />COVERED PATIO
<br />MINI SPLIT CONDENSER
<br />WITH 3'X3' CONCRETE
<br />PAD UNDERNEATH
<br />DECEMBER 4, 2024
<br />H
<br />MINI SPLIT
<br />CONDENSER WITH
<br />30"X30" CONCRETE
<br />PAD UNDERNEATH
<br />W/
<br />H NEW 40 GAL.
<br />ELECTRIC WATER
<br />HEATER INSIDE
<br />ARCHITECTURAL
<br />COMPATIBLE
<br />ENCLOSURE ,
<br />(SEE SPEC SHEET)
<br />PROPOSED NEW
<br />DETACHED ADU,
<br />LEGALIZATION OF
<br />WINDOWS & COVERED
<br />PATIO, PROPOSED NEW &
<br />MODIFICATION TO
<br />CONCRETE WALL
|