Laserfiche WebLink
HEAT PUMP WATER HEATER NOTES: <br />·40 GALLON HEAT PUMP WATER HEATER TO BE <br />INSTALLED PER MANUFACTURER INSTRUCTIONS. <br />·WATER HEATER MUST BE NORTHWEST ENERGY <br />EFFICIENCY ALLIANCE (NEEA) RATED HEAT PUMP <br />WATER HEATER; SPECIFIC BRAND/MODEL, OR <br />EQUIVALENT, MUST BE INSTALLED <br />·METAL ENCLOSURE OR SIMILAR PROTECTION MUST BE <br />INSTALLED. <br />RECESSED DOWN LIGHT FIXTURE HIGH EFFICACY (CFL OR LED LIGHTING) <br />CEILING LIGHT FIXTURE HIGH EFFICACY (CFL OR LED LIGHTING) <br />ARC FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET <br />GROUND FAULT INTERRUPTED DUPLEX OUTLET <br />WEATHERPROOF OUTLET - G.F.C.I. <br />WP/ <br />GFI <br />GFI <br />WALL MOUNTED W/ MOTION SENSOR AND TIMER LIGTH FIXTURE <br />ELECTRIC / UTILITY SYMBOLS: <br />EXHAUST FAN (MIN. 5 AIR CHANGES PER HOUR) WITH HUMIDITY CONTROL <br />AND VACANCY IN BATHROOMS <br />HOSE BIB AND SHUT OFF VALVEH.B. <br />(INSTALL HIGH EFFICACY LIGHTING) <br />CLG. FAN & LIGHT <br />3-WAY SWITCH @ 48" HIGH <br />HUMIDITY SENSOR @ 48" HIGH <br />SINGLE POLE SWITCH @ 42" HIGH <br />S <br />S <br />3 <br />S <br />CARBON MANOXIDE ALARMSC.M. <br />SLIDE DIMMER @ 48" HIGHS <br />IONIZATION SMOKE ALARM WITH ALARM-SILENCING SWITCH HARDWIRED <br />UL217 <br />GENERAL NOTES <br />SMOKE ALARMS <br />·SMOKE ALARMS SHALL BE LISTED PER UL 217, INSTALLED PER <br />NFPA 72 AND SHALL BE CALIF. STATE FIRE MARSHALL LISTED. <br />·SMOKE ALARMS SHALL BE INSTALLED MAINTAINED AND <br />CONNECTED IN THE FOLLOWING LOCATIONS/MANNER: <br />[R314.3,.4,.5] <br />··IN EACH SLEEPING ROOM. <br />··OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE <br />VICINITY OF THE BEDROOMS. <br />··ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING <br />BASEMENT AND SPLIT LEVELS. <br />··WHEN MORE THAN ONE SMOKE ALARM IS INSTALLED, THE <br />ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A <br />MANNER THAT THE ACTIVATION OF ONE ALARM WILL <br />ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. THE <br />ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER <br />BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS <br />CLOSED. <br />··SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER <br />FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED <br />FROM COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH <br />BATTERY BACKUP. <br />··SMOKE ALARMS SHALL BE PROVIDED IN ALL NEW <br />CONSTRUCTION LOCATED IN EACH SLEEPING ROOM, OUTSIDE <br />EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY <br />OF THE BEDROOMS, AND AT EACH ADDITIONAL FLOOR OR <br />BASEMENT LEVEL. [CRC R314.3] <br />··SMOKE ALARMS NOT INSTALLED A MINIMUM OF 20 FEET <br />HORIZONTAL DISTANCE FROM COOKING EQUIPMENT. <br />MONOXIDE ALARM REQUIREMENTS: <br />·FOR DWELLING UNIT CONSTRUCTION HAVING AN ATTACHED <br />GARAGE OR FUEL-BURNIG APPLIANCES, AN APPROVED CARBON <br />MONOXIDE ALARM UL 2034/2075 SHALL BE INSTALLED, <br />MAINTAINCE AND CONNECTED IN THE FOLLOWING <br />LOCATIONS/MANNER: <br />··OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE <br />VICINITY OF THE BEDROOM(S). <br />··ON EVERY LEVEL OF A DWELLING UNIT INCLUDING <br />BASEMENTS. <br />··WHERE MORE THAN ONE CO ALARM IS INSTALLED, THE <br />ALARM SHALL BE INTERCONNECTED IN A MANNER THAT <br />ACTIVATION OF ONE ALARM SHALL ACTIVATED ALL OF THE <br />ALARMS. <br />·IN EXISTING DWELLINGS WHERE WHERE A PERMIT FOR <br />ALTERATIONS, REPAIRS OR ADDITIONS EXCEED $1000 CO <br />ALARMS SHALL BE INSTALLED, MAINTAINED AND CONNECTED IN <br />THE FOLLOWING LOCATIONS/MANNER: [314.3.1,.4,.6] <br />··THE DWELLING SHALL BE EQUIPPED WITH CO ALARMS <br />LOCATED AS REQUIRED FOR NEW CONSTRUCTION. <br />··CO ALARMS ARE PERMITTED TO BE SOLELY BATTERY <br />OPERATED WHERE NO CONSTRUCTION IS TAKING PLACE. <br />LUMINARIES AND FANS <br />·THIS CLASSIFICATION APPLIES ONLY TO ROOMS THAT ARE NOT <br />KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, CLOSETS, <br />OR UTILITY ROOMS. ALL INSTALLED LUMINARIES SHALL BE <br />EITHER BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A <br />VACANCY SENSOR OR DIMMER. <br />·IN SINGLE-FAMILY RESIDENCIES, ALL LUMINARIES MOUNTED TO <br />THE BUILDING (OR TO EITHER BUILDING ON THE SAME LOT) <br />SHALL BE HIGH EFFICACY LUMINARIES, AND SHALL BE <br />CONTROLLED BY A MOTION SENSOR AND ALSO BY A <br />PHOTOCONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY <br />MANAGEMENT CONTROL SYSTEM (EMCS) (OUTDOOR CEILING <br />FANS WITH LIGHTS) <br />·ALL SINGLE FAMILY OUTDOOR LIGHTING SHALL BE HIGH <br />EFFICACY AND MUST BE CONTROLLED BY A MANUEL ON & OFF <br />SWITCH AND ONE OF THE FOLLOWING AUTOMATIC CONTROL <br />TYPES: <br />··PHOTOCONTROL AND MOTION SENSOR <br />··PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL <br />··ASTRONOMICAL TIME CLOCK CONTROL <br />··EMCS <br />·LUMINARIES THAT ARE RECESSED INTO CEILINGS SHALL HAVE <br />AIRTIGHT HOUSING TO PREVENT CONDITIONED AIR ESCAPING <br />INTO THE CAVITY OR ATTIC, OR UNCONDITIONED AIR <br />INFILTRATING FROM THE CEILING OR ATTIC INTO THE <br />CONDITIONED SPACE (AT-LISTED). LUMINARIES THAT ARE <br />RECESSED INTO INSULATED CEILINGS ARE REQUIRED TO BE <br />RATED FOR INSULATION CONTACT ("IC-RATED"). <br />·BATHROOM EXHAUST FAN TO BE RATED FOR A MINIMUM OF 50 <br />CFM AND KITCHEN EXHAUST FAN TO BE RATED FOR A MINIMUM <br />OF 100 CFM. [CEnC 150.0(O)] <br />··LUMINARIES THAT ARE OR CONTAIN LIGHT SOURCES THAT <br />MEET <br />REFERENCE JOINT <br />APPENDIX JA8 REQUIREMENTS FOR DIMMING, AND THAT ARE NOT <br />CONTROLLED BE <br />OCCUPANCY SENSORS, SHALL HAVE DIMMING CONTROLS. [CEnC <br />150.0(k)2.J]. <br />·FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO <br />TERMINATE TO THE OUTSIDE OF THE BUILDING. <br />RECEPTACLES AND OUTLETS <br />·FOR A ONE-FAMILY DWELLING AND EACH UNIT OF A TWO-FAMILY <br />DWELLING THAT IS AT GRADE LEVEL, AT LEAST ONE RECEPTACLE <br />OUTLET ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN <br />6'-6" ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND <br />BACK OF THE DWELLING. ALL EXTERIOR OUTLETS SHALL BE <br />PROTECTED BY GFCI AND BE WEATHER PROOF. [2019 CEC - <br />SECTION 406.8]. <br />·ALL EXTERIOR OUTLETS SHALL BE GFCI (NO LONGER AN <br />EXCEPTION FOR HEIGHT) [2019 CEC - SECTION 210.8]. IN <br />ADDITION, THE RECEPTACLE SHALL HAVE AN ENCLOSURE THAT <br />IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED <br />(ATTACHMENT PLUG CAP NOT INSERTED AND RECEPTACLE <br />COVER CLOSED). ALL 15- AND 20- AMPERE, 125- AND 250-VOLT <br />NONLOCKING RECEPTACLES SHALL BE LISTED <br />WEATHER-RESISTANT TYPE. [2109 CEC - SECTION 406.9]. <br />·ANY HALLWAY 10' OR MORE IN LENGTH SHALL HAVE AT LEAST <br />ONE RECEPTACLE. SHOW RECEPTACLES ON THE PLANS. (210.52 <br />(H) CEC) <br />·AT LEAST ONE 120-VOLT, 20 AMPERE BRANCH CIRCUIT SHALL BE <br />PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). <br />SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS PER CEC <br />210.11. <br />·AT LEAST TWO OR MORE 20-AMP SMALL-APPLIANCE BRANCH <br />CIRCUITS SHALL BE PROVIDED AT THE KITCHEN. [CEC <br />210.11(C)(1)] <br />·PROVIDE ONE 20-AMP DEDICATED BRANCH CIRCUITS TO SUPPLY <br />LAUNDRY RECEPTACLE OUTLET(S). THIS CIRCUIT SHALL HAVE NO <br />OTHER OUTLETS PER CEC 210.11.(C)(2). <br />·RECEPTACLE SERVING KITCHEN COUNTERTOP SHALL NOT BE <br />SPACED MORE THAN 4 FEET APART. [CEC 210.52(C)(1)]. <br />·ALL 15 AND 20 AMP, 125 AND 250-VOLT, NONLOCKING TYPE <br />RECEPTACLES IN A DWELLING UNIT SHALL BE LISTED <br />TAMPER-RESISTANT RECEPTACLE [CEC 406.12(1)] EXCEPT FOR <br />RECEPTACLES: <br />··LOCATED MORE THAN 5 1/2 " ABOVE THE FLOOR. <br />··THAT ARE PART OF A LUMINAIRE OR APPLIANCE. <br />··LOCATED WITHIN A DEDICATED SPACE FOR APPLIANCE. <br />··REPLACEMENT NONGROUNDING TYPE. <br />·ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH <br />CIRCUITS SUPPLYING OUTLETS (NOT JUST RECEPTACLES) AND <br />UTILIZATION DEVICES INSTALLED IN DWELLING UNITS (INCLUDING <br />KITCHENS, DINING ROOMS, CLOSETS, HALLWAYS, SUNROOMS, <br />LAUNDRY, LIVING ROOMS, DENS, BEDROOMS) SHALL BE <br />PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, <br />COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF <br />THE BRANCH CIRCUIT. CEC 210.12(A) <br />·ELECTRICAL RECEPTACLES OUTLETS, SWITCHES, AND <br />CONTROLS (INCLUDING CONTROLS FOR HEATING VENTILATION <br />AND AIR CONDITIONING) INTENDED TO BE USED BY THE <br />OCCUPANTS SHALL BE LOCATED NOT MORE THAN 48 INCHES <br />MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS <br />THAN 15 INCHES MEASURE FROM THE BOTTOM OF THE OUTLET <br />BOX ABOVE THE FINISH FLOOR. <br />ELECTRICAL BOXES <br />·ELECTRICAL BOXES SHALL HAVE DRYWALL, PLASTER, OR <br />PLASTERBOARD SURFACES FINISHED SO THERE WILL BE NO <br />GAPSOR OPEN SPACES GREATER THAN 1/8" AT THE EDGE OF THE <br />BOX PER ARTICLE 314.21 (CEC). IN WALLS OR CEILINGS BOXES <br />SHALL BE INSTALLED SO THAT THE FRONT EDGE OF THE BOX OR <br />PLASTER RING SHALL NOT BE RECESSED MORE THAN 1/4" FROM <br />NON-COMBUSTIBLE FINISH SURFACE AND SHALL BE FLUSHED <br />WITH A COMBUSTIBLE SURFACE PER ARTICLE 314.20 (CEC). <br />·ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE- PHASE, <br />15 - AND 20 - AMPERE OUTLETS OR DEVICES INSTALLED IN <br />DWELLING UNIT KITCHEN, FAMILY ROOMS, DINING ROOMS, LIVING <br />ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, <br />RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS OR <br />SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY AN <br />ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE LISTED <br />TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT. <br />·NEW BOXES USED AT LUMINARIES OR LAMPHOLDER OUTLETS IN <br />A CEILING SHALL BE REQUIRED TO SUPPORT A LUMINAIRE <br />WEIGHING A MINIMUM OF 50 LBS. USED AT LUMINAIRE OUTLETS IN <br />WALLS SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE <br />MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF <br />THE LUMINAIRE PERMITTED, IF OTHER THAN 50 LBS. OUTLET <br />BOXES OR SYSTEM USED AS THE SOLE SUPPORT OF CEILING <br />FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURES AS <br />SUITABLE FOR THIS PURPOSE. (314.27 CEC). <br />·THE PANEL OR SUB-PANEL SHALL PROVIDE CAPACITY TO INSTALL <br />A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND <br />SPACE(S) RESERVED TO PERMIT INSTALLATION OF A BRANCH <br />CIRCUIT OVERCURRENT PROTECTIVE DEVICE. <br />·THE SERVICE PANEL OR SUB-PANEL CIRCUIT DIRECTORY SHALL <br />IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) <br />RESERVED FOR FUTURE EV CHARGING AS EV CAPABLE. THE <br />RACEWAY TERMINATION LOCATION SHALL BE PERMANENT AND <br />VISIBLY MARKED EV CAPABLE. <br />·LOCATION OF ELECTRICAL SERVICE PANEL MUST BE APPROVED <br />BY EDISON <br />ELECTRICAL NOTES: <br />·ALL JAB COMPLIANT LIGHT SOURCES, EXCEPT THOSE IN <br />CLOSETS LESS THAN 70 SQUARE FEET AND THOSE IN HALLWAYS <br />SHALL BE CONTROLLED BY A VACANCY SENSOR (150(K)2J CEC). <br />·ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES (SUCH <br />AS LIGHTS & SWITCHES) INSTALLED IN DWELLING UNIT KITCHENS, <br />FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, <br />LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, <br />CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS, & <br />AREAS SHALL BE PROVIDED WITH ARC-FAULT <br />CIRCUIT-INTERRUPTER (AFCI) PROTECTION. SEE CEC SECTION <br />210.12(A) FOR PERMISSIBLE MEANS OF AFCI PROTECTION (210.12 <br />CEC). <br />· IN BATHROOMS, LAUNDRY ROOMS, AND UTILITY ROOMS, AT <br />LEAST ONE LUMINARIES IN EACH OF THE THOSE SPACES SHALL <br />BE CONTROLLED BY A VACANCY SENSOR (150(K)2J CEC) <br />MECHANICAL NOTES: <br />·CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL <br />DISCHARGE TO A PLUMBING FIXTURE OR AN APPROVED <br />LOCATION BY MEANS OF AN INDIRECT WASTE PIPE. CONDENSATE <br />LINES SHALL NOT TERMINATE IN LANDSCAPE OR YARDS AREAS. <br />(310.5 CMC). <br />·DUCTS FOR DRYER VENTS SHALL BE A MINIMUM OF 4" IN <br />DIAMETER. THE EXHAUST DUCT SHALL NOT EXCEED A TOTAL <br />COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FT. <br />INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET SHALL BE <br />DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCEES OF TWO. <br />(CMC 504.3.1.) <br />·A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A <br />MINIMUM OF 4" IN DIAMETER. THE EXHAUST DUCT SHALL NOT <br />EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGHT <br />OF 14', INCLUDING TWO 90 DEGREE ELBOWS. TWO FEETS SHALL <br />BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCEES OF TWO. <br />(504.4.2 CMC). <br />A.504.4.1 PROVISIONS FOR MAKEUP AIR. <br />A.A.MAKEUP AIR SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />FOLLOWING: <br />A.B.MAKEUP AIR SHALL BE PROVIDED FOR TYPE 1 CLOTHES <br />DRYERS IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTRUCTIONS. [NFPA 54:10.4.3.1]. WHERE A CLOSET IS <br />DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN <br />OPENING OF NOT LESS THAN 100 SQUARE INCHES (0.065 M2) <br />FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY <br />OTHER APPROVED MEANS. <br />133/4"11" <br />77/8" <br />93/8"107/8" <br />4" <br />80 CFM/1.0 Sones @ 0.10" SP. <br />70 CFM @ 0.25" SP. <br />SPECIFICATIONS <br />LEDAK80H <br />EXHAUST FAN WITH LIGHT <br />·IAQ FAN <br />CONTINUOUSLY <br />RUNNING IS <br />LOCATED IN <br />BATHROOM AREA - <br />IS A EXHAUST FAN <br />OF 80 CFM <br />·TWO EXHAUST FAN <br />OF 80 CFM EA. WITH <br />HUMIDITY CONTROL <br />AND 5 AIR CHANGES <br />PER HOUR MIN. SEE <br />DETAIL ON <br />ELECTRICAL/UTILITY <br />SYMBOLS. <br />·ONE EXHAUST FAN <br />OF 100 CFM MIN. ON <br />TOP OF THE STOVE. <br />IAQ FAN <br />ELECTRICAL PLAN <br />FACTOR <br />2 <br />QUANTITY <br />3 <br />4 <br />5 <br />6 <br />3 x 408 SQ FT <br />1500 X 2 <br />VOLT AMPERES <br />1,224 <br />3,000 <br />1,500 <br />5,724 <br />3,000 <br />953 <br />1500 X 1 <br />1 <br />7 3,953 <br />General Lighting (SQFT X 3 VA/SQ FT (Table 220.12) <br />Small Appliance Circuits (1500 VA per circuit) (NEC 220.52 (A)) (minimum 2) <br />Laundry Circuit (1500 VA per circuit) (NEC 220.52 (B)) <br />Total General Lighting Load <br />First 3000 VA @ 100% <br />Net General Lighting Load (Per NEC 220.42) <br />*Fixed Appliances <br />Garbage Disposal <br />Bathroom Fan (1 X 20) <br />(VA) <br />"General Lighting" <br />Total General Lighting Load 5,724 - 3000 = 2,724 @ 35% = <br />Microwave <br />Dishwasher <br />*Other Loads (including motors, EV charger(s), etc.) <br />9 Electric Range (8,000VA or Nameplate)** <br />10 Heat Pump MINI SPLIT <br />11 <br />12 <br />Electric Dryer (5000 VA minimum)** <br />13 <br />Electric Vehicle Charger <br />YES NO <br />20 <br />TOTAL 1,147 <br />8 3 or less Appliances, Total Appliance VA; 4 or more Appliances, 75% of Total Appliance VA (NEC 220.53): 1,147 x 75% =1,147 <br />YES NO <br />3,300 <br />14 <br />15 <br />25% of largest motor (NEC 430.24)1,800 <br />Total Service Load Volt-Amperes (VA) (Add lines 7, 8, & 9, thru 16)=28,199 <br />Total Service Load Volt-Amperes 28,199 / 240-volts = 117 Amperes <br />ELECTRICAL LOAD CALCULATIONS <br />16 <br />Other: <br />Heat Pump Electric Water Heater <br />Electric Induction Oven <br />D <br />H <br />MS <br />1,127 <br />8,000 <br />5,000 <br />4,999 <br />SCALE: <br />SHEET No: <br />DATE: <br />DRAWN BY: <br />DATE SHEET: <br />CONTENT: <br />DATE PROJECT: <br />OWNER: <br />ADDRESS: <br />A.P.N.: <br />TITLE: <br />REVISION DATE <br />DATE PROJECT NO. <br />RESPONSABLE: <br />1 <br />2 <br />3 <br />NOTE: <br />4 <br />5 <br />6 <br />1671 THIRD ST. SUITE 102 <br />NORCO, CA. 92680 <br />PH: (951) 407-1131 <br />ELECTRICAL <br />PLAN <br />ELVIRA KENNEDY <br />E-1 <br />3/8" = 1'-0"LEGEND <br />NEW WALL <br />UL 2034/2075, CARBON MONOXIDE ALARMS SHALL BE <br />INTERCONNECTED AND HARDWIRED. [CRC R315.1.1 & R315.1.2] <br />12K <br />MINI SPLIT <br />HOOD VENT OVER RANGE <br />ATTIC <br />ACCESS <br />30" X 30" <br />ONE HOUR FIRE WALL <br />MS <br />80 CFM <br />80 CFM <br />100 CFM <br />E <br />NEW ELECTRICAL <br />100 AMPS <br />SUB-PANEL <br />GFI <br />GFI <br />GFI <br />GFI <br />SS <br />S <br />S <br />S SS <br />S <br />S S <br />H.B. <br />C.M. <br />D <br />D <br />D <br />H <br />H <br />IRMA DE LA TORRE <br />1702 S. GARNSEY ST. <br />SANTA ANA, CA 92707 <br />013-244-01 <br />DISCONNECTDC <br />GFI <br />MS <br />S <br />VACANCY SENSOR @ 48" HIGHS <br />V <br />S <br />COVERED PATIO <br />MINI SPLIT CONDENSER <br />WITH 3'X3' CONCRETE <br />PAD UNDERNEATH <br />DECEMBER 4, 2024 <br />H <br />MINI SPLIT <br />CONDENSER WITH <br />30"X30" CONCRETE <br />PAD UNDERNEATH <br />W/ <br />H NEW 40 GAL. <br />ELECTRIC WATER <br />HEATER INSIDE <br />ARCHITECTURAL <br />COMPATIBLE <br />ENCLOSURE , <br />(SEE SPEC SHEET) <br />PROPOSED NEW <br />DETACHED ADU, <br />LEGALIZATION OF <br />WINDOWS & COVERED <br />PATIO, PROPOSED NEW & <br />MODIFICATION TO <br />CONCRETE WALL