SCALE: <br />SHEET No: <br />DATE: <br />DRAWN BY: <br />DATE SHEET: <br />CONTENT: <br />DATE PROJECT: <br />OWNER: <br />ADDRESS: <br />A.P.N.: <br />TITLE: <br />REVISION DATE <br />DATE PROJECT NO. <br />RESPONSABLE: <br />1 <br />2 <br />3 <br />NOTE: <br />4 <br />5 <br />6 <br />1671 THIRD ST. SUITE 102 <br />NORCO, CA. 92680 <br />PH: (951) 407-1131 <br />WATER FIXTURE UNIT (WFU) <br />WATER PIPE SIZED PER 2022 CALIFORNIA PLUMBING CODE TABLE 610.3 <br />METER AND <br />STREET <br />SERVICE <br />(INCHES) <br />BUILDING <br />SUPPLY <br />AND BRANCHES <br />(INCHES)100 150 200 250 300 <br />MAXIMUM ALLOWABLE <br />LENGTH (FEET) <br />PRESSURE RANGE - OVER 60 PSI <br />3/4"1 1/4"39 <br />TABLE 610.4 FIXTURE UNIT TABLE FOR <br />DETERMINING WATER PIPE AND METER SIZE <br />PLUMBING FIXTURE <br />WFU/ <br />FIXTURE TOTAL FIXTURES WFU <br />TOTAL WFU 26 <br />1 42SINK <br />39 39 39 39 <br />MIN. FIXTURE BRANCH <br />SIZE1,4 (INCHES) <br />1 <br />NEW ADU <br />PLUMBING <br />PLAN <br />ELVIRA KENNEDY <br />3/8" = 1'-0" <br />P-1 <br />2 82SHOWER HEAD 1 <br />LENGTH FROM WATER METER TO FURTHEST WATER FIXTURE: 109 FEET <br />WATER CLOSET, 1.6 GPF <br />LAVATORY <br />2 <br />2 <br />10 <br />4 <br />2.5 <br />1 <br />2 <br />2 <br />GENERAL NOTES: <br />DETERMINING PROPER SIZE: <br />PROPER SIZING OF THE PIPE IS IMPORTANT SO THAT EACH GAS APPLIANCE RECEIVES ENOUGH GAS TO PERFORM PROPERLY. EACH <br />APPLIANCE HAS A MINIMUM INPUT DEMAND IN BTUS PER HOUR. EACH TYPE OF PIPE MATERIAL ALSO HAS A DIFFERENT FLOW RATES. <br />THE CHART BELOW GIVES SOME EXAMPLES OF TYPICAL BTU DEMANDS FROM TABLE 12-1. TO PROPERLY DETERMINING THE PIPE SIZE <br />FOR YOUR JOB, CONSULT THE 2022 CPC, CHAPTER 12. WHEN PROVIDING GAS LOAD CALCULATIONS, THE CURRENT CODES AND <br />TABLES MUST BE DOCUMENTED IN YOUR SUBMITTAL. <br />TO CONVERT FROM BTUS TO CUBIC FEET PER HOUR DIVIDE BTU/1100 (EXAMPLE: 50,000 BTU BY 1100 = 45.5 CUBIC FEET OF GAS PER <br />HOUR). SEE THE EXAMPLE ON PAGE 2 TO HELP FURTHER ILLUSTRATE THIS. TO GET BTU FROM CUBIC FEET, MULTIPLY CUBIC X FEET <br />1100 (45.5 CUBIC FEET X 1100 = 50,000 BTU.) <br />APPROVED GAS PIPING FITTING MATERIALS <br />APPROVED MATERIALS ARE DESCRIBED IN SECTION CPC 2022 SECTION 1208. METALLIC PIPE, METALLIC TUBING AND PLASTIC, TUBING <br />AND FITTINGS ARE SAMPLES OF APPROVED MATERIALS. COPPER, BRASS AND ALUMINUM ALLOY PIPING SHALL NOT BE USED EXCEPT <br />UNDER CERTAIN CONDITIONS AS OUTLINED IN SECTION 1208.6 WILL REQUIRE THE SUBMITTAL OF AN ALTERNATE MATERIALS REQUEST <br />AND BUILDING OFFICIAL APPROVAL. <br />WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, <br />CPVC AND OTHER PLASTIC WATER PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 604 OF <br />THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURERS RECOMMENDED INSTALLATION STANDARDS. <br />CPVC WATER PIPING REQUIRES A CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC. 604.1.1 OF THE CPC PRIOR TO PERMIT <br />ISSUANCE. <br />CUTTING PIPE <br />IF YOU ARE CUTTING METALLIC PIPE OR TUBING, YOU MUST REAM THE CUT OF YOUR PIPE SO YOU MAINTAIN THE FULL INSIDE <br />DIAMETER OF THE PIPE AND BE CLEAR OF CUTTING BURRS AND DEFECTS IN THE STRUCTURE AND/OR THREADING PER SECTION <br />1208.6.8. <br />SPECIAL INSTRUCTIONS <br />ALL INSTALLATION SHALL BE IN COMPLIANCE WITH SECTION 1210.0 FOR UNDERGROUND, COVERING, PROTECTION AGAINST <br />CORROSION. <br />TESTING <br />A PRESSURE TEST, PROVIDED BY APPLICANT, IS REQUIRED PER THE 2022 CPC, SECTION 1213. TEST PRESSURE SHALL BE MEASURED <br />WITH A MANOMETER OR WITH A PRESSURE-MEASURING DEVICE DESIGNED AND CALIBRATED TO READ, RECORD, OR INDICATE A <br />PRESSURE LOSS DUE TO LEAKAGE DURING THE PRESSURE TEST PERIOD. THE SOURCE OF PRESSURE SHALL BE ISOLATED BEFORE <br />THE PRESSURE TESTS ARE MADE. MECHANICAL GAUGES USED TO MEASURE TEST PRESSURES SHALL HAVE A RANGE SUCH THAT THE <br />HIGHEST END OF THE SCALE IS NOT GREATER THAN FIVE TIMES THE TEST PRESSURE. <br />WATER PIPING MATERIALS <br />WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, <br />CPVC AND OTHER PLASTIC WATER PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 604 OF <br />THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURERS RECOMMENDED INSTALLATION STANDARDS. <br />CPVC WATER PIPING REQUIRES A CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC. 604.1.1 OF THE CPC PRIOR TO PERMIT <br />ISSUANCE. <br />WATER HEATING SYSTEM NOTES <br />A.A DEDICATED 125-VOLT, 20-AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRICAL PANEL WITH A 120/240-VOLT <br />3 CONDUCTORS, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER <br />HEATER WITH NO OBSTRUCTIONS. IN ADDITION, ALL OF THE FOLLOWING: <br />i.BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORK USPARE" AND BE ELECTRICALLY ISOLATED; <br />AND <br />ii.A SERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER FOR <br />THE BRANCH CIRCUIT IN "A" ABOVE AND LABELED WITH THE WORDS "FUTURE 240V USE"; AND <br />B.A CATEGORY ILL OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE BETWEEN THE OUTSIDE TERMINATION AND THE SPACE <br />WHERE THE WATER HEATER IS INSTALLED; AND <br />C.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND <br />ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE; AND <br />INSPECTION <br />WHEN THE INSTALLATION AND TESTING YOUR SYSTEM FOR LEAKS IS COMPLETE, PLEASE SCHEDULE YOUR INSPECTION <br />ACCORDINGLY. THE INSPECTOR WILL NEED TO SEE THE COMPLETE SYSTEM BEING TESTED. YOU MUST SUPPLY THE TEST GAUGE AS <br />DESCRIBED ABOVE. THE SYSTEM MUST BE UNDER TEST WHEN THE INSPECTOR ARRIVES. (SECTIONS 1213.3 AND SECTION 318.0) <br />1.THE SHOWER SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVE OF PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION <br />PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE. <br />2.BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH SHOWERS AND SHOWER COMPARTMENTS SHALL BE <br />FINISHED WITH A NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6 FT. ABOVE THE FLOOR. (CRC R307.2 CBC 1209.2.3) <br />3.CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUM BACKERS <br />SHALL BE AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. <br />NOTES <br />DUCTS PENETRATING WALL OR CEILING SEPARATIONS BETWEEN A GARAGE AND A DWELLING UNIT SHALL BE CONSTRUCTED OF A <br />MINIMUM 26 GAGE SHEET METAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />WATER CLOSET SHALL HAVE 15" TO ANY WALL OR OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24" CLEAR SPACE IN FRONT. <br />(402.5 CPC). <br />WATER HEATERS LOCATED IN SEISMIC DESIGN CATEGORIES C, D, E, & F, AS DEFINED BY THE BUILDING CODE, SHALL HAVE STRAPS <br />LOCATED IN THE UPPER AND LOWER 1/3 OF ITS VERTICAL DIMENSION. (507.2 CPC). <br />WATER CLOSETS SHALL HAVE AN AVERAGE WATER CONSUMPTION OF NOT MORE THAN 1.6 GALLONS OF WATER PER FLUSH, 1.28 <br />GALLONS PER FLUSH AFTER JULY 1, 2011. (401.3 CPC). <br />WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, <br />CPVC ANDOTHER PLASTIC WATER PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 604 OF <br />THE CPC, INSTALLATION STANDARDS OF APPENDIX 1 OF THE CPC AND MANUFACTURERS RECOMMENDED INSTALLATION STANDARDS. <br />CPVC WATER PIPING REQUIRES A CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC 604.1.1 OF THE CPC PRIOR TO PERMIT <br />ISSUANCE. <br />CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL DISCHARGE TO A PLUMBING FIXTURE OR AN APPROVED LOCATION BY <br />MEANS OF AN INDIRECT WASTE PIPE. CONDENSATE LINES SHALL NOT TERMINATE IN LANDSCAPE OR YARDS AREAS. (310.5 CMC). <br />A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A MINIMUM OF 4" IN DIAMETER. THE EXHAUST DUCT SHALL NOT EXCEED <br />A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGHT OF 14', INCLUDING TWO 90 DEGREE ELBOWS. TWO FEETS SHALL BE <br />DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCEES OF TWO. (504.4.2 CMC). <br />504.4.1 PROVISIONS FOR MAKEUP AIR. <br />MAKEUP AIR SHALL BE PROVIDED IN ACCORDANCE WITH THE FOLLOWING: <br />MAKEUP AIR SHALL BE PROVIDED FOR TYPE 1 CLOTHES DRYERS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. [NFPA <br />54:10.4.3.1]. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING OF NOT LESS THAN 100 <br />SQUARE INCHES (0.065 M2) FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS. <br />PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON-COMPLIANT PLUMBING FIXTURES WITHIN THIS RESIDENCE SHALL <br />BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. ANY BUILDING FINALED ON OR BEFORE 01/01/94 ARE REQUIRED TO <br />REPLACE NON COMPLIANT FIXTURES (Note to PCer: this does not apply to repairs). <br />AS PER CHAPTER 12 OF 2019 CALIFORNIA PLUMBING CODE: <br /> 1215.0 REQUIRED GAS PIPING SIZE <br /> 1215.2 TABLES FOR SIZING GAS PIPING SYSTEMS <br /> TABLE 1215.2(1) <br />SCHEDULE 40 METALLIC PIPE <br />HOT, COLD WATER & WASTE LINE PLAN <br />3 4" PEX COLD WATER LINE SUPPLY3/4" <br />3 4" PEX HOT WATER LINE SUPPLY (INSULATED)3/4" <br />LEGEND <br />WASTE PIPE <br />2" ABS VENT <br />2"V <br />12K <br />ATTIC <br />ACCESS <br />30" X 30" <br />E <br />IRMA DE LA TORRE <br />1702 S. GARNSEY ST. <br />SANTA ANA, CA 92707 <br />013-244-011/2" CW <br />1/2" HW <br />1/2" CW <br />1/2" CW <br />1/2" HW <br />1/2" CW <br />1/2" HW <br />1/2" CW <br />1/2" HW <br />12K <br />ATTIC <br />ACCESS <br />30" X 30" <br />E <br />2" <br />2" <br />3" <br />2" <br />2" <br />3" <br />TO EXISTING SEWAGE <br />TO WATER METER <br />DECEMBER 4, 2024 <br />W/ <br />HNEW 40 GAL. ELECTRIC <br />WATER HEATER INSIDE <br />ARCHITECTURAL <br />COMPATIBLE <br />ENCLOSURE , <br />(SEE SPEC SHEET) <br />W/ <br />H <br />PROPOSED NEW <br />DETACHED ADU, <br />LEGALIZATION OF <br />WINDOWS & COVERED <br />PATIO, PROPOSED NEW & <br />MODIFICATION TO <br />CONCRETE WALL