A
<br />A
<br />B
<br />B
<br />C
<br />C
<br />D
<br />D
<br />E
<br />E
<br />F
<br />F
<br />1 1
<br />2 2
<br />3 3
<br />4 4
<br />5 5
<br />5'
<br />
<br />-
<br />
<br />6
<br />"
<br />9'
<br />
<br />-
<br />
<br />2
<br />"
<br />13
<br />'
<br />
<br />-
<br />
<br />8
<br />"
<br />8'
<br />
<br />-
<br />
<br />0
<br />"
<br />3' - 8"
<br />12
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />18' - 4"7' - 6"27' - 4"6' - 4"47' - 0"
<br />106' - 6"
<br />MECHANICAL
<br />PATIO
<br />STOR.KIT.
<br />STAFF
<br />WORKROOM/LOUNGE
<br />KITCHEN RESTROOM
<br />MULTIPURPOSE
<br />ROOM
<br />STORAGE
<br />ELEC. RM JAN.
<br />MENS WOMENS
<br />COORIDOR
<br />STORAGE/SUPPLIES WORKROOM
<br />INNOVATION
<br />CENTER
<br />CHILDRENS
<br />STACKS MEDIA CENTERFAMILY RR
<br />OPEN
<br />LOBBY
<br />3' - 0"5' - 6 3/4"
<br />7' - 6"
<br />001
<br />001
<br />001 001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />001 001
<br />001
<br />001
<br />001
<br />001001
<br />001
<br />001
<br />001
<br />001
<br />001
<br />011.A
<br />011.A
<br />009
<br />011.A
<br />011.A
<br />011.A
<br />011.A 011.A
<br />011.A
<br />154
<br />154
<br />154
<br />154
<br />154
<br />154160161153
<br />049
<br />011.A
<br />011.A
<br />166
<br />166
<br />114 114
<br />114
<br />005
<br />005
<br />005
<br />032
<br />005
<br />005
<br />005
<br />004
<br />005005005005005
<br />009
<br />127127
<br />004
<br />011.A
<br />011.A
<br />169
<br />172
<br />173
<br />-
<br />260000.G
<br />27
<br />'
<br />
<br />-
<br />
<br />1
<br />0
<br />"
<br />13' - 3"
<br />31
<br />'
<br />
<br />-
<br />
<br />7
<br />"
<br />10' - 10"260000.G
<br />24
<br />'
<br />
<br />-
<br />
<br />1
<br />0
<br />
<br />3
<br />/
<br />4
<br />"
<br />13
<br />'
<br />
<br />-
<br />
<br />1
<br />0
<br />"
<br />3' - 10"
<br />22' - 4 1/4"
<br />8' - 6 3/4"
<br />11' - 1"
<br />1'
<br />
<br />-
<br />
<br />0
<br />"
<br />8' - 5 1/4"260000.G
<br />29
<br />'
<br />
<br />-
<br />
<br />2
<br />
<br />1
<br />/
<br />4
<br />"
<br />260000.G
<br />260000.G
<br />260000.G
<br />260000.G
<br />260000.G
<br />8' - 1 1/2"
<br />7'
<br />
<br />-
<br />
<br />4
<br />"
<br />2' - 10 1/4"
<br />9'
<br />
<br />-
<br />
<br />8
<br />"
<br />1' - 7"
<br />10' - 6"7' - 7 1/4"
<br />8' - 10 1/2"
<br />8'
<br />
<br />-
<br />
<br />3
<br />"
<br />24' - 9"
<br />260000.G
<br />260000.G
<br />260000.G260000.G260000.G
<br />260000.G
<br />4'
<br />
<br />-
<br />
<br />4
<br />"
<br />4'
<br />
<br />-
<br />
<br />5
<br />
<br />1
<br />/
<br />2
<br />"
<br />7' - 11"
<br />1' - 0"2' - 10"
<br />3'
<br />
<br />-
<br />
<br />0
<br />"
<br />8' - 2"
<br />12
<br />'
<br />
<br />-
<br />
<br />3
<br />
<br />3
<br />/
<br />4
<br />"
<br />1. DEMOLITION DRAWINGS PREPARED BY THE ARCHITECT ARE FOR A GENERAL DESCRIPTION OF
<br />EXISTING BUILDING COMPONENTS, ASSEMBLIES AND MATERIALS TO BE REMOVED. DEMOLITION
<br />CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND QUANTITIES.
<br />2. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PROVIDING NECESSARY PERMITS REQUIRED
<br />BY FEDERAL, STATE AND LOCAL MUNICIPAL AGENCIES HAVING JURISDICTIONAL AUTHORITY
<br />OVER ANY ASPECT OF THE DEMOLITION SCOPE.
<br />3. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION WORK.
<br />4. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL
<br />DEMOLISHED MATERIALS IN A MANNER COMPLIANT TO FEDERAL, STATE AND LOCAL MUNICIPAL
<br />REQUIREMENTS AND GUIDELINES.
<br />5. DEMOLITION CONTRACTOR SHALL COORDINATE ALL WORK SCHEDULES WITH OWNER. IN NO
<br />CASE SHALL DEMOLITION WORK BE CONDUCTED DURING HOURS PROHIBITED BY LOCAL
<br />MUNICIPALITY.
<br />6. PLANS ARE BASED ON EXISTING RECORD DRAWINGS AND VISUAL OBSERVATION.
<br />UNIDENTIFIED ITEMS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNERS
<br />REPRESENTATIVE PRIOR TO REMOVAL.
<br />7. ALSO REFERENCE CIVIL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL
<br />DEMOLITION DRAWINGS FOR ADDITIONAL COORDINATION OF ITEMS TO BE REMOVED OR
<br />PROTECTED IN PLACE.
<br />8. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION COORDINATION AND PATCH BACK FOR
<br />STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DEMOLITION.
<br />9. ELECTRICAL CONTRACTOR TO LOCATE CONNECTIVITY AND CONDUIT RUNS.
<br />EXISTING METAL STUD WALL
<br />EXISTING CONCRETE WALL
<br />EXISTING WALL TO BE REMOVED
<br />EXISTING STOREFRONT SYSTEM TO BE REMOVED
<br />EXISTING DOOR/FRAME/HW TO BE REMOVED
<br />REMOVE (E) DRY PACK AND PROVIDE (N)
<br />CONCRETE SLAB FLOOR.
<br />EXISTING ITEM & EQUIPMENT
<br />TO BE DEMOLISHED
<br />SAWCUT AND REMOVE PORTION
<br />OF (E) CONCRETE SLAB
<br />A
<br />A
<br />B
<br />B
<br />C
<br />C
<br />D
<br />D
<br />E
<br />E
<br />F
<br />F
<br />1 1
<br />2 2
<br />3 3
<br />4 4
<br />5 5
<br />080
<br />080
<br />080080
<br />080
<br />116
<br />116
<br />116 116
<br />116
<br />080
<br />116
<br />080080
<br />080080
<br />080
<br />080080
<br />N.I.C.
<br />N.I.C.
<br />+9' -0"
<br />+8' -0"
<br />+8' -0"
<br />+8' -0"+8' -0"
<br />+9' -0"
<br />+8' -0"
<br />+8' -0"
<br />+8' -0"+8' -0"
<br />+8' -0"+8' -0"+8' -0"
<br />+8' -0"
<br />+9' -4"
<br />+8' -0"
<br />+8' -0"+8' -0"
<br />+9' -4"
<br />+9' -4"
<br />+9' -4"
<br />+8' -0"
<br />165
<br />117
<br />162
<br />163
<br />153153077200.A
<br />167
<br />167
<br />167
<br />167
<br />168
<br />+18' - 0"
<br />282300.B
<br />282300.B
<br />282300.B 282300.B
<br />170
<br />170
<br />282300.B
<br />170
<br />170
<br />282300.B
<br />-
<br />127
<br />127
<br />080
<br />TYP.
<br />TYP.
<br />TYP.
<br />NOTES:
<br />1. GYPSUM BOARD CEILINGS SHALL BE FRAMED WITH METAL STUD JOISTS, U.N.O. SEE DETAIL 02/A64.4
<br />FOR MORE INFORMATION.
<br />2. FOR SUSPENDED ACOUSTICAL CEILING, REFER TO SHEET A64.6.
<br />3. NOT USED
<br />4. AT ALL ROOMS WITHOUT CEILINGS (LABELLED AS "EXP" ON PLAN AND/OR ON THE FINISH SCHEDULE),
<br />ALL EXPOSED SURFACES AND ELEMENTS SHALL BE PAINTED, INCLUDING STRUCTURE, DECK ABOVE, AND
<br />ALL UTILITIES INCLUDING PIPING, CONDUITS, DUCTWORK, ETC.
<br />5. PLUMBING, ELECTRICAL, MECHANICAL AND FIRE PROTECTION COMPONENTS ARE SHOWN FOR
<br />REFERNECE AND COORDINATION PURPOSES. REFER TO PLUMBING, ELECTRICAL, MECHANICAL AND FIRE
<br />PROTECTION DRAWINGS FOR COMPONENT AND SYSTEM QUANTITIES, TYPES AND REQUIREMENTS
<br />6. CENTER LIGHTING FIXTURES BETWEEN OPPOSITE WALLS, U.N.O.
<br />7. ALL DIMENSIONS, NOTES, KEYNOTES AND DETAILS CALLOUTS ARE TYPICAL, U.N.O.
<br />8. SEE SHEET A50.1 FOR INTERIOR FINISH LEGEND
<br />9. AT EXPOSED CEILINGS, ALL DUCTS, PIPES AND CONDUITS SHALL RUN PARALLEL OR PERPENDICULAR
<br />TO WALL, AND AS CLOSE TO THE DECK ABOVE AS POSSIBLE. PROVIDE ESCUTCHEONS FOR
<br />CONDUIT/PIPES AT WALLS WHERE EXPOSED.
<br />* REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EMERGENCY LIGHTING.
<br />(E) 2' X 4' ACT
<br />CEILING
<br />SYSTEM TO
<br />BE REMOVED
<br />(E) GYP. BOARD
<br />CEILING TO BE
<br />REMOVED
<br />(E) 2' X 2' ACT
<br />CEILING SYSTEM
<br />TO BE REMOVED
<br />(E) EXTERIOR PLASTER
<br />SOFFIT CEILING TO BE
<br />REMOVED
<br />(E) WOOD T&G TO
<br />REMAIN AND BE
<br />PROTECTED IN
<br />PLACE
<br />(E) BEAMS THAT ARE TO BE
<br />PROTECTED IN PLACE. GYPSUM
<br />BOARD CEILING TO BE
<br />REMOVED.
<br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS
<br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF
<br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY
<br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR
<br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA
<br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018.
<br />SCALE:
<br />REVISIONS:
<br />OW
<br />N
<br />E
<br />R
<br />:
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />
<br />N
<br />A
<br />M
<br />E
<br />:
<br />CL
<br />I
<br />E
<br />N
<br />T
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />:
<br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707
<br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM
<br />DATE ISSUED:
<br />PROJECT NO:
<br />As indicated
<br />07/08/24
<br />A10.0
<br />RCP AND FLOOR
<br />DEMOLITION
<br />PLANS
<br />2022-40123
<br />CI
<br />T
<br />Y
<br />
<br />O
<br />F
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />NE
<br />W
<br />H
<br />O
<br />P
<br />E
<br />
<br />L
<br />I
<br />B
<br />R
<br />A
<br />R
<br />Y
<br />MO
<br />D
<br />E
<br />R
<br />N
<br />I
<br />Z
<br />A
<br />T
<br />I
<br />O
<br />N
<br />12
<br />2
<br />
<br />N
<br />.
<br />
<br />N
<br />E
<br />W
<br />H
<br />O
<br />P
<br />E
<br />
<br />S
<br />T
<br />.
<br />,
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />1/8" = 1'-0"1DEMOLITION -FLOOR PLAN DEMOLITION NOTES
<br />DEMO PLAN LEGEND
<br />001 EXISTING DOOR & FRAME TO BE REMOVED IN ITS ENTIRETY
<br />004 DEMOLISH EXISTING CASEWORK/CABINETRY AS SHOWN
<br />005 REMOVE ALL EXISTING PLUMBING FIXTURES (INCLUDING TOILETS, SINKS,
<br />CHANGING TABLES), PARTITIONS AND RESTROOM ACCESSORIES
<br />THROUGHOUT EXISTING RESTROOM
<br />009 APPROXIMATE AREA TO BE SAWCUT TO REMOVE PORTION OF EXISTING
<br />CONCRETE SLAB FOR NEW WORK REFER TO OTHER DISCIPLINES FOR
<br />EXTENT OF WORK (SLAB TO BE REPLACED WITH NEW WORK - PER
<br />13/A62.3)
<br />011.A DEMOLISH EXISTING WALL, TYP.
<br />032 EXISTING STOREFRONT SYSTEM TO BE REMOVED IN THEIR ENTIRETY
<br />049 EXISTING DRINKING FOUNTAIN TO BE REMOVED
<br />080 DEMOLISH EXISTING CEILING, INCLUDING ALL SUPPORTS, FIXTURES,
<br />ETC.
<br />114 EXISTING WINDOW & FRAME TO BE REMOVED AND FILLED WITH NEW
<br />WALL SEE 01/A11.0
<br />116 DEMO EXISTING CEILING GRID IN ENTIRETY INCLUDING RUNNERS, EDGE
<br />TRIMS, SUPPORTS, SPLAY WIRES, COMPRESSION STRUTS, AND CEILING
<br />TILES
<br />117 REMOVE EXISTING LIGHT FIXTURES, COORDINATE WITH THE DISTRICT'S
<br />REPRESENTATIVE FOR RETENTION AND REUSE
<br />127 DEMO EXISTING CARPET TILE AND VCT FLOORING, CLEAN AND PREP
<br />FOR NEW FINISH
<br />153 (E) GATE TRELLIS, POSTS, LOW CMU WALL, AND ALL FOOTINGS
<br />ASSOCIATED WITH EXISTING TRELLIS TO BE REMOVED IN ITS ENTERITY,
<br />PREP AREA FOR INSTALLATION OF (N) SHADE CANOPY. PATCH AND
<br />REPAIR CONCRETE WHERE NEEDED
<br />154 REMOVE WALL MOUNTED WOOD PANELING, CLEAN AND PREP
<br />SUBSTRATE FOR PARASOLEIL ALUMINUM "CORTEN" PANEL ATTACHMENT
<br />160 REMOVE EXISTING METAL GATE FENCING, TYP.
<br />161 REMOVE EXISTING METAL GATE DOUBLE DOOR, TYP.
<br />162 REMOVE EXISTING MECHANICAL SUPPLY IN ITS ENTIRETY
<br />163 REMOVE EXISTING MECHANICAL RETURN IN ITS ENTIRETY
<br />165 EXISTING WOOD CEILING PANELING IS TO REMAIN PROTECTED IN PLACE
<br />166 DEMO EXISTING WOOD WALL PANELING. CLEAN AND PREP SURFACE
<br />FOR NEW TYPE X GYP.
<br />167 PROTECT IN PLACE EXISTING EXPOSED WOOD BEAMS AND COLUMNS,
<br />BEAMS/COLUMNS ARE TO BE CLEANED, PREPPED, TO BE WALNUT SHELL
<br />BLASTED TO REMOVE EXISTING FINISH AND SEALED WITH A CLEAR
<br />PENETRATING WOOD SEALER. WALNUT SHELL ABRASIVES TBD IN FIELD
<br />BASED ON TESTING OF EXISTING FINISH REFER TO A50.1 FOR PAINT
<br />FINISH TYP.
<br />168 DEMO EXISTING PENDANT LIGHT, SEE ELECTRICAL TYP.
<br />169 REMOVE AND REPLACE EXISTING DRYWALL IN PREPARATION FOR NEW
<br />WORK. PREP DRYWALL FOR INSTALL OF "FLO" INTERLOCKINGROCK
<br />MODULAR ACOUSTIC WALL PANELS, SEE SPEC
<br />170 DEMO EXISTING VIDEO SURVEILLANCE CAMERA, PATCH AND REPAIR
<br />EXTERIOR IN KIND, TYP.
<br />172 EXISTING CABINETRY AND KITCHEN EQUIPMENT TO BE REMOVED IN ITS
<br />ENTIRETY.
<br />173 EXISTING SLOPING SIDEWALK TO BE DEMOLISHED AND REPLACED WITH
<br />S.O.G.
<br />077200.A (N) ROOF HATCH, SEE DET. 1/A14.1
<br />260000.
<br />G
<br />EXISTING ELECTRICAL POWER BOX IN THE GROUND
<br />282300.B EXISTING VIDEO SECURITY SURVEILLANCE TO REMAIN PROTECTED IN
<br />PLACE, TYP
<br />1/8" = 1'-0"2DEMOLITION -REFLECTED CEILING PLAN
<br />DEMO RCP LEGEND
<br />DESCRIPTION DATE
<br />1 ASI #01 04/09/25
<br />4 ASI #04 09/18/25
<br />4
<br />4
<br />4
|