Laserfiche WebLink
A <br />A <br />B <br />B <br />C <br />C <br />D <br />D <br />E <br />E <br />F <br />F <br />1 1 <br />2 2 <br />3 3 <br />4 4 <br />5 5 <br />5' <br /> <br />- <br /> <br />6 <br />" <br />9' <br /> <br />- <br /> <br />2 <br />" <br />13 <br />' <br /> <br />- <br /> <br />8 <br />" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />3' - 8" <br />12 <br />' <br /> <br />- <br /> <br />0 <br />" <br />18' - 4"7' - 6"27' - 4"6' - 4"47' - 0" <br />106' - 6" <br />MECHANICAL <br />PATIO <br />STOR.KIT. <br />STAFF <br />WORKROOM/LOUNGE <br />KITCHEN RESTROOM <br />MULTIPURPOSE <br />ROOM <br />STORAGE <br />ELEC. RM JAN. <br />MENS WOMENS <br />COORIDOR <br />STORAGE/SUPPLIES WORKROOM <br />INNOVATION <br />CENTER <br />CHILDRENS <br />STACKS MEDIA CENTERFAMILY RR <br />OPEN <br />LOBBY <br />3' - 0"5' - 6 3/4" <br />7' - 6" <br />001 <br />001 <br />001 001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />001 001 <br />001 <br />001 <br />001 <br />001001 <br />001 <br />001 <br />001 <br />001 <br />001 <br />011.A <br />011.A <br />009 <br />011.A <br />011.A <br />011.A <br />011.A 011.A <br />011.A <br />154 <br />154 <br />154 <br />154 <br />154 <br />154160161153 <br />049 <br />011.A <br />011.A <br />166 <br />166 <br />114 114 <br />114 <br />005 <br />005 <br />005 <br />032 <br />005 <br />005 <br />005 <br />004 <br />005005005005005 <br />009 <br />127127 <br />004 <br />011.A <br />011.A <br />169 <br />172 <br />173 <br />- <br />260000.G <br />27 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />13' - 3" <br />31 <br />' <br /> <br />- <br /> <br />7 <br />" <br />10' - 10"260000.G <br />24 <br />' <br /> <br />- <br /> <br />1 <br />0 <br /> <br />3 <br />/ <br />4 <br />" <br />13 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />3' - 10" <br />22' - 4 1/4" <br />8' - 6 3/4" <br />11' - 1" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />8' - 5 1/4"260000.G <br />29 <br />' <br /> <br />- <br /> <br />2 <br /> <br />1 <br />/ <br />4 <br />" <br />260000.G <br />260000.G <br />260000.G <br />260000.G <br />260000.G <br />8' - 1 1/2" <br />7' <br /> <br />- <br /> <br />4 <br />" <br />2' - 10 1/4" <br />9' <br /> <br />- <br /> <br />8 <br />" <br />1' - 7" <br />10' - 6"7' - 7 1/4" <br />8' - 10 1/2" <br />8' <br /> <br />- <br /> <br />3 <br />" <br />24' - 9" <br />260000.G <br />260000.G <br />260000.G260000.G260000.G <br />260000.G <br />4' <br /> <br />- <br /> <br />4 <br />" <br />4' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />7' - 11" <br />1' - 0"2' - 10" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />8' - 2" <br />12 <br />' <br /> <br />- <br /> <br />3 <br /> <br />3 <br />/ <br />4 <br />" <br />1. DEMOLITION DRAWINGS PREPARED BY THE ARCHITECT ARE FOR A GENERAL DESCRIPTION OF <br />EXISTING BUILDING COMPONENTS, ASSEMBLIES AND MATERIALS TO BE REMOVED. DEMOLITION <br />CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND QUANTITIES. <br />2. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PROVIDING NECESSARY PERMITS REQUIRED <br />BY FEDERAL, STATE AND LOCAL MUNICIPAL AGENCIES HAVING JURISDICTIONAL AUTHORITY <br />OVER ANY ASPECT OF THE DEMOLITION SCOPE. <br />3. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION WORK. <br />4. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL <br />DEMOLISHED MATERIALS IN A MANNER COMPLIANT TO FEDERAL, STATE AND LOCAL MUNICIPAL <br />REQUIREMENTS AND GUIDELINES. <br />5. DEMOLITION CONTRACTOR SHALL COORDINATE ALL WORK SCHEDULES WITH OWNER. IN NO <br />CASE SHALL DEMOLITION WORK BE CONDUCTED DURING HOURS PROHIBITED BY LOCAL <br />MUNICIPALITY. <br />6. PLANS ARE BASED ON EXISTING RECORD DRAWINGS AND VISUAL OBSERVATION. <br />UNIDENTIFIED ITEMS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNERS <br />REPRESENTATIVE PRIOR TO REMOVAL. <br />7. ALSO REFERENCE CIVIL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL <br />DEMOLITION DRAWINGS FOR ADDITIONAL COORDINATION OF ITEMS TO BE REMOVED OR <br />PROTECTED IN PLACE. <br />8. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION COORDINATION AND PATCH BACK FOR <br />STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DEMOLITION. <br />9. ELECTRICAL CONTRACTOR TO LOCATE CONNECTIVITY AND CONDUIT RUNS. <br />EXISTING METAL STUD WALL <br />EXISTING CONCRETE WALL <br />EXISTING WALL TO BE REMOVED <br />EXISTING STOREFRONT SYSTEM TO BE REMOVED <br />EXISTING DOOR/FRAME/HW TO BE REMOVED <br />REMOVE (E) DRY PACK AND PROVIDE (N) <br />CONCRETE SLAB FLOOR. <br />EXISTING ITEM & EQUIPMENT <br />TO BE DEMOLISHED <br />SAWCUT AND REMOVE PORTION <br />OF (E) CONCRETE SLAB <br />A <br />A <br />B <br />B <br />C <br />C <br />D <br />D <br />E <br />E <br />F <br />F <br />1 1 <br />2 2 <br />3 3 <br />4 4 <br />5 5 <br />080 <br />080 <br />080080 <br />080 <br />116 <br />116 <br />116 116 <br />116 <br />080 <br />116 <br />080080 <br />080080 <br />080 <br />080080 <br />N.I.C. <br />N.I.C. <br />+9' -0" <br />+8' -0" <br />+8' -0" <br />+8' -0"+8' -0" <br />+9' -0" <br />+8' -0" <br />+8' -0" <br />+8' -0"+8' -0" <br />+8' -0"+8' -0"+8' -0" <br />+8' -0" <br />+9' -4" <br />+8' -0" <br />+8' -0"+8' -0" <br />+9' -4" <br />+9' -4" <br />+9' -4" <br />+8' -0" <br />165 <br />117 <br />162 <br />163 <br />153153077200.A <br />167 <br />167 <br />167 <br />167 <br />168 <br />+18' - 0" <br />282300.B <br />282300.B <br />282300.B 282300.B <br />170 <br />170 <br />282300.B <br />170 <br />170 <br />282300.B <br />- <br />127 <br />127 <br />080 <br />TYP. <br />TYP. <br />TYP. <br />NOTES: <br />1. GYPSUM BOARD CEILINGS SHALL BE FRAMED WITH METAL STUD JOISTS, U.N.O. SEE DETAIL 02/A64.4 <br />FOR MORE INFORMATION. <br />2. FOR SUSPENDED ACOUSTICAL CEILING, REFER TO SHEET A64.6. <br />3. NOT USED <br />4. AT ALL ROOMS WITHOUT CEILINGS (LABELLED AS "EXP" ON PLAN AND/OR ON THE FINISH SCHEDULE), <br />ALL EXPOSED SURFACES AND ELEMENTS SHALL BE PAINTED, INCLUDING STRUCTURE, DECK ABOVE, AND <br />ALL UTILITIES INCLUDING PIPING, CONDUITS, DUCTWORK, ETC. <br />5. PLUMBING, ELECTRICAL, MECHANICAL AND FIRE PROTECTION COMPONENTS ARE SHOWN FOR <br />REFERNECE AND COORDINATION PURPOSES. REFER TO PLUMBING, ELECTRICAL, MECHANICAL AND FIRE <br />PROTECTION DRAWINGS FOR COMPONENT AND SYSTEM QUANTITIES, TYPES AND REQUIREMENTS <br />6. CENTER LIGHTING FIXTURES BETWEEN OPPOSITE WALLS, U.N.O. <br />7. ALL DIMENSIONS, NOTES, KEYNOTES AND DETAILS CALLOUTS ARE TYPICAL, U.N.O. <br />8. SEE SHEET A50.1 FOR INTERIOR FINISH LEGEND <br />9. AT EXPOSED CEILINGS, ALL DUCTS, PIPES AND CONDUITS SHALL RUN PARALLEL OR PERPENDICULAR <br />TO WALL, AND AS CLOSE TO THE DECK ABOVE AS POSSIBLE. PROVIDE ESCUTCHEONS FOR <br />CONDUIT/PIPES AT WALLS WHERE EXPOSED. <br />* REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EMERGENCY LIGHTING. <br />(E) 2' X 4' ACT <br />CEILING <br />SYSTEM TO <br />BE REMOVED <br />(E) GYP. BOARD <br />CEILING TO BE <br />REMOVED <br />(E) 2' X 2' ACT <br />CEILING SYSTEM <br />TO BE REMOVED <br />(E) EXTERIOR PLASTER <br />SOFFIT CEILING TO BE <br />REMOVED <br />(E) WOOD T&G TO <br />REMAIN AND BE <br />PROTECTED IN <br />PLACE <br />(E) BEAMS THAT ARE TO BE <br />PROTECTED IN PLACE. GYPSUM <br />BOARD CEILING TO BE <br />REMOVED. <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />07/08/24 <br />A10.0 <br />RCP AND FLOOR <br />DEMOLITION <br />PLANS <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />1/8" = 1'-0"1DEMOLITION -FLOOR PLAN DEMOLITION NOTES <br />DEMO PLAN LEGEND <br />001 EXISTING DOOR & FRAME TO BE REMOVED IN ITS ENTIRETY <br />004 DEMOLISH EXISTING CASEWORK/CABINETRY AS SHOWN <br />005 REMOVE ALL EXISTING PLUMBING FIXTURES (INCLUDING TOILETS, SINKS, <br />CHANGING TABLES), PARTITIONS AND RESTROOM ACCESSORIES <br />THROUGHOUT EXISTING RESTROOM <br />009 APPROXIMATE AREA TO BE SAWCUT TO REMOVE PORTION OF EXISTING <br />CONCRETE SLAB FOR NEW WORK REFER TO OTHER DISCIPLINES FOR <br />EXTENT OF WORK (SLAB TO BE REPLACED WITH NEW WORK - PER <br />13/A62.3) <br />011.A DEMOLISH EXISTING WALL, TYP. <br />032 EXISTING STOREFRONT SYSTEM TO BE REMOVED IN THEIR ENTIRETY <br />049 EXISTING DRINKING FOUNTAIN TO BE REMOVED <br />080 DEMOLISH EXISTING CEILING, INCLUDING ALL SUPPORTS, FIXTURES, <br />ETC. <br />114 EXISTING WINDOW & FRAME TO BE REMOVED AND FILLED WITH NEW <br />WALL SEE 01/A11.0 <br />116 DEMO EXISTING CEILING GRID IN ENTIRETY INCLUDING RUNNERS, EDGE <br />TRIMS, SUPPORTS, SPLAY WIRES, COMPRESSION STRUTS, AND CEILING <br />TILES <br />117 REMOVE EXISTING LIGHT FIXTURES, COORDINATE WITH THE DISTRICT'S <br />REPRESENTATIVE FOR RETENTION AND REUSE <br />127 DEMO EXISTING CARPET TILE AND VCT FLOORING, CLEAN AND PREP <br />FOR NEW FINISH <br />153 (E) GATE TRELLIS, POSTS, LOW CMU WALL, AND ALL FOOTINGS <br />ASSOCIATED WITH EXISTING TRELLIS TO BE REMOVED IN ITS ENTERITY, <br />PREP AREA FOR INSTALLATION OF (N) SHADE CANOPY. PATCH AND <br />REPAIR CONCRETE WHERE NEEDED <br />154 REMOVE WALL MOUNTED WOOD PANELING, CLEAN AND PREP <br />SUBSTRATE FOR PARASOLEIL ALUMINUM "CORTEN" PANEL ATTACHMENT <br />160 REMOVE EXISTING METAL GATE FENCING, TYP. <br />161 REMOVE EXISTING METAL GATE DOUBLE DOOR, TYP. <br />162 REMOVE EXISTING MECHANICAL SUPPLY IN ITS ENTIRETY <br />163 REMOVE EXISTING MECHANICAL RETURN IN ITS ENTIRETY <br />165 EXISTING WOOD CEILING PANELING IS TO REMAIN PROTECTED IN PLACE <br />166 DEMO EXISTING WOOD WALL PANELING. CLEAN AND PREP SURFACE <br />FOR NEW TYPE X GYP. <br />167 PROTECT IN PLACE EXISTING EXPOSED WOOD BEAMS AND COLUMNS, <br />BEAMS/COLUMNS ARE TO BE CLEANED, PREPPED, TO BE WALNUT SHELL <br />BLASTED TO REMOVE EXISTING FINISH AND SEALED WITH A CLEAR <br />PENETRATING WOOD SEALER. WALNUT SHELL ABRASIVES TBD IN FIELD <br />BASED ON TESTING OF EXISTING FINISH REFER TO A50.1 FOR PAINT <br />FINISH TYP. <br />168 DEMO EXISTING PENDANT LIGHT, SEE ELECTRICAL TYP. <br />169 REMOVE AND REPLACE EXISTING DRYWALL IN PREPARATION FOR NEW <br />WORK. PREP DRYWALL FOR INSTALL OF "FLO" INTERLOCKINGROCK <br />MODULAR ACOUSTIC WALL PANELS, SEE SPEC <br />170 DEMO EXISTING VIDEO SURVEILLANCE CAMERA, PATCH AND REPAIR <br />EXTERIOR IN KIND, TYP. <br />172 EXISTING CABINETRY AND KITCHEN EQUIPMENT TO BE REMOVED IN ITS <br />ENTIRETY. <br />173 EXISTING SLOPING SIDEWALK TO BE DEMOLISHED AND REPLACED WITH <br />S.O.G. <br />077200.A (N) ROOF HATCH, SEE DET. 1/A14.1 <br />260000. <br />G <br />EXISTING ELECTRICAL POWER BOX IN THE GROUND <br />282300.B EXISTING VIDEO SECURITY SURVEILLANCE TO REMAIN PROTECTED IN <br />PLACE, TYP <br />1/8" = 1'-0"2DEMOLITION -REFLECTED CEILING PLAN <br />DEMO RCP LEGEND <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25 <br />4 ASI #04 09/18/25 <br />4 <br />4 <br />4