Laserfiche WebLink
Refrigerator <br />A21.2 <br />1 <br />A B <br />C <br />C <br />E F <br />F <br />1 <br />2 <br />3 <br />4 <br />5 <br />2 <br />A31.1 <br />1 <br />A31.1 <br />5' <br /> <br />- <br /> <br />6 <br />" <br />9' <br /> <br />- <br /> <br />2 <br />" <br />13 <br />' <br /> <br />- <br /> <br />8 <br />" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />3' - 8" <br />10 <br />' <br /> <br />- <br /> <br />6 <br />" <br />12 <br />' <br /> <br />- <br /> <br />0 <br />" <br />18' - 4"7' - 6"27' - 4"6' - 4"47' - 0" <br />106' - 6" <br />OPEN <br />131 <br />MEETING ROOM <br />130 <br />MECHANICAL <br />136 <br />STAFF LOUNGE <br />121 <br />STAFF WORKROOM <br />122 <br />STAFF RESTROOM <br />123 <br />COMMUNITY ROOM <br />110 <br />IDF <br />119 <br />STORAGE <br />118 <br />STORAGE <br />117 <br />ELEC. RM <br />111 <br />CUSTODIAL <br />113 <br />WOMEN'S <br />115 <br />MEN'S <br />116 <br />STORAGE/SUPPLIES <br />105 <br />CIRCULATION <br />WORKROOM <br />107 <br />INNOVATION CENTER <br />104 <br />LOBBY <br />CORRIDOR <br />106 <br />CHILDREN'S STACKS <br />124 <br />FAMILY RR <br />126 <br />OPEN <br />132 <br />OPEN <br />133 <br />OPEN <br />134 <br />8' - 1" <br />1 <br />3 <br />/ <br />4 <br />" <br />14' - 0 3/4" <br />10 <br />' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />LIBRARIAN <br />137 <br />W3.4 <br />W3.6 <br />W6.6 <br />W5.4 <br />W3.4 <br />E83 <br />N98 <br />N96 <br />E62 <br />N66 <br />E56E55 <br />E57 <br />N106 <br />N97 <br />N94 <br />N105 <br />N95 <br />N76N87 <br />E63 <br />W5.4 <br />W5.4 <br />1 <br />A61.1 <br />A31.2 <br />1 <br />PATIO <br />N79 <br />B <br />W3.4 <br />W3.6 <br />W3.6 <br />N90 N91 <br />N92 <br />4' - 0" <br />9" <br />4' - 0" <br />9" <br />4' - 0" <br />9" <br />4' - 0" <br />9" <br />4' - 0" <br />9" <br />4' - 0" <br />8 3/4" <br />4' - 0" <br />E84 <br />N101 <br />N102 <br />A31.4 <br />3 <br />4 <br />221000.E <br />W3.4 <br />W3.4 W3.4 <br />7' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />A31.4 5 <br />5' - 6 1/4" <br />A62.4 <br />3 <br />A31.41 <br />034 <br />6 <br />A31.4 13 <br />A31.4 <br />9 <br />A31.4 <br />11 <br />FRONT <br />LOBBY <br />ENTRANCE <br />-SF12/ A62.2 <br />21 <br />' <br /> <br />- <br /> <br />4 <br /> <br />1 <br />/ <br />4 <br />" <br />40' - 11" <br />A52.11 <br />OPEN <br />AREA <br />WINDOWS <br />-SF35/ A62.2 <br />INNOVATION <br />CENTER <br />-SF41/ A62.2 <br />A31.3 <br />1 <br />034 <br />W3.4 W3.4 <br />A62.5 <br />3 <br />A52.1 <br />2 <br />A52.1 <br />2 <br />A21.3 <br />1 <br />26' - 10 1/4" <br />24 <br />' <br /> <br />- <br /> <br />4 <br /> <br />1 <br />/ <br />4 <br />" <br />41' - 2" <br />2' - 5" <br />W1 <br />A62.4 <br />1 <br />2 <br />W2 <br />3 <br />2 <br />4 <br />7' <br /> <br />- <br /> <br />9 <br /> <br />3 <br />/ <br />4 <br />" <br />6' <br /> <br />- <br /> <br />0 <br />" <br />3 <br />A31.1 <br />4 <br />A31.1 <br />A21.2 <br />2 <br />W3.6 <br />E <br />C <br />7' - 8 1/2" <br />AB <br />H <br />F <br />G <br />L <br />H <br />C <br />L <br />L <br />L <br />L <br />O L <br />L <br />O <br />D <br />D <br />Q <br />3' - 3"3' - 3"5' - 4"5' - 4"3' - 3" <br />24 <br />' <br /> <br />- <br /> <br />4 <br /> <br />3 <br />/ <br />4 <br />" <br />10 <br />' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />12' - 2 1/2" <br />A62.3 <br />2 <br />28' - 5" <br />12 <br />' <br /> <br />- <br /> <br />3 <br /> <br />3 <br />/ <br />4 <br />" <br />8' - 1" <br />5' <br /> <br />- <br /> <br />0 <br /> <br />3 <br />/ <br />4 <br />" <br />17' - 6" <br />2' - 10 3/4" <br />1' <br /> <br />- <br /> <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />A31.412 <br />104400.C <br />104400.D <br />116100.B <br />10' - 2 1/2" <br />K <br />K <br />A31.1 5 <br />W3.4B SF3 <br />DETAIL <br />KEY-/ - <br />W3.4 <br />W7.8 <br />W1.1 <br />W2.1 <br />W7.5 <br />W7.5 <br />W7.5 <br />A62.1 <br />8 <br />A62.1 <br />8 <br />5 <br />A61.1 <br />5 <br />A61.1 <br />A52.14 <br />4 <br />E87 <br />N50 <br />N110 <br />5 <br />A52.1 <br />033000.G <br />N99 <br />178 <br />178 <br />221000.K 221000.K221000.K <br />W3.4 <br />4 <br />A <br />B <br />RESTROOM DOOR SIGNAGE - WOMEN 2/GEN-6 <br />RESTROOM DOOR SIGNAGE - MEN 3/GEN-6 <br />C RESTROOM DOOR SIGNAGE - ALL GENDERS 4/GEN-6 <br />D ASSISTIVE LISTENING SIGN 17/GEN-6 <br />F RESTROOM SIGN - WOMEN 6/GEN-6 <br />G RESTROOM SIGN - MEN 7/GEN-6 <br />H RESTROOM SIGN - ALL GENDERS 8/GEN-6 <br />K TACTILE EXIT ROUTE SIGN 12/GEN-6 <br />L TACTILE ROOM IDENTIFICATION SIGN 11/GEN-6 <br />M ACCESSIBLE ENTRY SIGN 9/GEN-6 <br />O TACTILE EXIT SIGN 14/GEN-6 <br />Q <br />R DIRECTIONAL ACCESS SIGN 10/GEN-6 <br />DESCRIPTION SHT.NO. <br />OCCUPANT LOAD SIGN 13/GEN-6 <br />S BOOK DROPOFF SIGNAGE 18/GEN-6 <br />I FIRE ALARM PANEL LOCATED INSIDE 15/GEN-6 <br />J FIRE ALARM EMERG. POWER SRC. 16/GEN-6 <br />NEW WOOD STUD WALL PER SHEET A61.1 <br />EXISTING WOOD STUD WALL <br />EXISTING CONCRETE WALL <br />WALL TYPE ANNOTATIONS, SEE SHEET <br />A61.1 FOR DETAILS <br />101 NUMBER INDICATES DOOR PER SCHEDULE, <br />REFER TO SHEET A52.1 <br />EXISTING FIRE EXTINGUISHER CABINET <br />FLOOR PLAN GENERAL NOTES: <br />1. ALL DIMENSIONS ARE TO CENTERLINE OF THE GRID LINES AND/OR TO THE FACE OF STUDS, U.N.O. <br />2. UNLESS NOTED OTHERWISE, ALL WALLS ARE FULL HEIGHT. <br />3. REFER TO SHEET GEN-4 FOR TYPICAL ACCESSIBILTY REQUIREMENTS AND DIMENSIONS. <br />4. REFER TO ENLARGED PLANS FOR DIMENSIONS AND CALLOUTS NOT SHOWN HERE ON SHEETS A31.2 <br />AND A31.3 <br />1i <br />60" MIN. ACCESSIBLE WHEELCHAIR <br />CLEAR TURNING SPACE <br />CLR. 60" MIN. <br />30"X48" MIN. ACCESSIBLE WHEELCHAIR <br />CLEAR FLOOR SPACE <br />30"X48" <br /> CLR. <br />EXIT <br />00 <br />NEW EXIT ID / SIGNAGE REFER TO ELECT W/ SECONDARY POWER <br />SOURCE. ALL EXIT DOORS SHALL LAHVE CODE COMPLAINT PANIC DEVICE <br />AND CLOSER U.O.N. <br />DISABLED ACCESS / EXIT PATH OF TRAVEL <br />DBL LINE = COMMON PATH OF TRAVEL <br />EXIT AEX <br />I <br />T <br /> <br />B <br />INDICATES TWO ACCESSIBLE EXITS BEYOND 75' TRAVEL DISTANCE <br />NEW CONCRETE SLAB ON GRADE PER <br />STRUCTURAL DRAWINGS. <br />EXISTING WALL TO REMAIN, PROVIDE <br />LATERAL BRACING, SEE STRUCTURAL <br />DRAWINGS SHEETS S1.2. <br />A B C D E F <br />1 <br />2 <br />3 <br />4 <br />5 <br />092116.C <br />092116.C <br />095100.C <br />095100.C095100.C <br />095100.C <br />095100.C095100.C <br />EQ <br />CL <br />CL <br />CL <br />CL <br />CL <br />CL <br />CL <br />CL <br />EQ <br />EQ <br />EQ <br />EQ <br />EQ <br />EQ <br />EQ <br />3' - 0"6' - 0" <br />EQ <br />EQ <br />CLCLCL <br />6' - 2"6' - 2" <br />MECHANICAL <br />136 <br />IDF <br />119 <br />STORAGE <br />118 <br />COMMUNITY ROOM <br />110 <br />STORAGE <br />117 <br />MEN'S <br />116 <br />WOMEN'S <br />115 <br />STAFF RESTROOM <br />123 <br />LIBRARIAN <br />137 <br />STAFF WORKROOM <br />122 <br />STAFF LOUNGE <br />121 <br />STORAGE/SUPPLIES <br />105 <br />CIRCULATION <br />WORKROOM <br />107 <br />LOBBY <br />101 <br />INNOVATION CENTER <br />104 <br />CHILDREN'S STACKS <br />124 <br />FAMILY RR <br />126 <br />MEETING ROOM <br />130 <br />CUSTODIAL <br />113 <br />VEST. <br />114 <br />VEST. <br />112 <br />ELEC. RM <br />111 <br />CORRIDOR <br />106 <br />OPEN <br />132 <br />OPEN <br />134 <br />OPEN <br />133 <br />OPEN <br />131 <br />CORRIDOR <br />102 <br />9' - 4" <br />8' - 0"8' - 0" <br />8' - 0" <br />8' - 0" <br />8' - 0" <br />8' - 0" <br />8' - 0" <br />8' - 0" <br />9' - 0" <br />8' - 0"8' - 0" <br />8' - 0" <br />8' - 0" <br />8' - 0" <br />8' - 0" <br />260000.C <br />260000.C <br />8' - 0" <br />CL <br />CL <br />4' <br /> <br />- <br /> <br />0 <br />" <br />CLCL <br />23' - 0"12' - 0" <br />CL <br />4' - 2"8' - 7" <br />3' <br /> <br />- <br /> <br />1 <br />0 <br /> <br />3 <br />/ <br />4 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />CL <br />CL <br />CL <br />3' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />CL <br />CL <br />CL <br />3' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />CL <br />CL <br />CL <br />3' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />CL <br />CL <br />CL <br />3' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />CL <br />3' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />CL <br />CL <br />CL <br />CL <br />4' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br /> <br />- <br /> <br />4 <br />" <br />4' <br /> <br />- <br /> <br />1 <br />" <br />5' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />OPEN <br />AREA <br />WINDOWS <br />-SF35/ A62.2 <br />INNOVATION <br />CENTER <br />-SF41/ A62.2 <br />5' <br /> <br />- <br /> <br />5 <br />" <br />2' - 6 1/2" <br />CL <br />3' - 2" <br />CL <br />3' - 3" <br />CL 1' <br /> <br />- <br /> <br />9 <br />" <br />CL <br />2' - 3" <br />CL <br />2' - 7" <br />CL2' <br /> <br />- <br /> <br />3 <br />" <br />CL <br />1' - 11 1/2" <br />CL <br />2' - 2 1/2" <br />CL <br />EQ <br />EQ <br />CL <br />3' <br /> <br />- <br /> <br />6 <br />" <br />CL <br />3' - 8 1/2" <br />CL <br />12' - 0" <br />092116.C <br />9' - 4" <br />CLCL <br />6' - 0"5' - 0" <br />CL <br />CL <br />3' <br /> <br />- <br /> <br />2 <br />" <br />6' <br /> <br />- <br /> <br />0 <br />" <br />+9' -4" <br />+8' -0" <br />+8' -0"+8' -0" <br />5' - 8" <br />1' - 11" <br />7' - 1" <br />4' - 4" <br />12' - 9 1/2" <br />130000.B <br />260000.C <br />2' <br /> <br />- <br /> <br />7 <br />" <br />095110.A <br />+11' -0" <br />+9' -4" <br />+9' -4" <br />+9' -4" <br />+9' -4" <br />+9' -4" <br />+18' - 0" <br />282300.B <br />A31.1 5 <br />A52.14 <br />5 <br />A52.1 <br />NOTES: <br />1. GYPSUM BOARD CEILINGS SHALL BE FRAMED WITH METAL STUD JOISTS, U.N.O. SEE <br />DETAIL 04/A64.4 FOR MORE INFORMATION. <br />2. FOR SUSPENDED ACOUSTICAL CEILING, REFER TO SHEET A64.4. <br />3. FOR PLASTER SOFFIT DETAILS, SEE DETAIL 9/A62.1 <br />4. AT ALL ROOMS WITHOUT CEILINGS (LABELLED AS "EXP" ON PLAN AND/OR ON THE <br />FINISH SCHEDULE), ALL EXPOSED SURFACES AND ELEMENTS SHALL BE PAINTED, <br />INCLUDING STRUCTURE, DECK ABOVE, AND ALL UTILITIES INCLUDING PIPING, <br />CONDUITS, DUCTWORK, ETC. <br />5. PLUMBING, ELECTRICAL, MECHANICAL AND FIRE PROTECTION COMPONENTS <br />ARE SHOWN FOR REFERNECE AND COORDINATION PURPOSES. REFER TO <br />PLUMBING, ELECTRICAL, MECHANICAL AND FIRE PROTECTION DRAWINGS <br />FOR COMPONENT AND SYSTEM QUANTITIES, TYPES AND REQUIREMENTS <br />6. CENTER LIGHTING FIXTURES BETWEEN OPPOSITE WALLS, U.N.O. <br />7. ALL DIMENSIONS, NOTES, KEYNOTES AND DETAILS CALLOUTS ARE TYPICAL, U.N.O. <br />8. SEE SHEET A50.1 FOR INTERIOR FINISH LEGEND <br />9. AT EXPOSED CEILINGS, ALL DUCTS, PIPES AND CONDUITS SHALL RUN PARALLEL OR <br />PERPENDICULAR TO WALL, AND AS CLOSE TO THE DECK ABOVE AS POSSIBLE. <br />PROVIDE ESCUTCHEONS FOR CONDUIT/PIPES AT WALLS WHERE EXPOSED. <br />* REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EMERGENCY LIGHTING. <br />EXTERIOR PLASTER SOFFIT, REFER TO NOTE 3 <br />2' X 4' SUSPENDED CEILING TILES, REFER TO NOTE <br />2 <br />RECESSED SUPPLY AIR GRILL, SEE MECH. DRAWINGS <br />RECESSED RETURN AIR GRILL, SEE MECH. DRAWINGS <br />2X2 LUMINAIRE, SEE ELEC. DRAWINGS* <br />RECESSED COMPACT FLUORESCENT DOWNLIGHT, SEE ELEC. DRAWINGS* <br />S S SPEAKERS, SEE ELECTRICAL DRAWINGS <br />EXIT SIGNAGE, SEE ELECTRICAL DRAWINGS <br />SUSPENDED STRIP FLUORESCENT, SEE ELEC. DRAWINGS* <br />SUSPENDED FLUORESCENT FIXTURE, SEE ELEC. DRAWINGS* <br />RECESSED EXHAUST AIR GRILL, SEE MECH. <br />DRAWINGS <br />2X4 LUMINAIRE, SEE ELEC. DRAWINGS* <br />GYP. BOARD CEILING, REFER TO NOTE 1 <br />ROOF HATCH ABOVE, REFER TO DET. 8/A62.6 <br />SURFACE MOUNTED FLUORESCENT FIXTURE, SEE ELEC. DRAWINGS* <br />WALL MOUNTED FLUORESCENT LIGHT FIXTURE, SEE ELEC. DRAWINGS* <br />WALL MOUNTED FLUORESCENT DOWNLIGHT, SEE ELEC. DRAWINGS* <br />WALL MOUNTED TO BE 8' - 0" TYP. <br />WALL MOUNTED FIXTURE AT STAIR, SEE ELEC. DRAWINGS* <br />DECORATIVE PENDANT MOUNTED FIXTURE, SEE ELEC. DRAWINGS* <br />2' X 2' SUSPENDED CEILING TILES, REFER TO NOTE <br />2 <br />SUSPENDED HEXAGONAL FLUORESCENT LIGHT FIXTURE, SEE ELEC. <br />DRAWINGS* <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />07/08/24 <br />A11.0 <br />RCP AND FLOOR <br />IMPROVEMENT <br />PLAN <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />1/8" = 1'-0"1IMPROVEMENT -FLOOR PLAN <br />SIGNAGE LEGEND <br />FLOOR PLAN LEGEND <br />034 EXISTING COLUMN TO REMAIN & PROTECTED IN PLACE <br />178 EXISTING PARTITION WALL TO REMAIN, SEE STRUCTURAL <br />DRAWINGS DETAILS 3, 5, 7/S1.2 FOR LATERAL BRACING. <br />033000.G NEW CONCRETE SLAB TO REPLACE DRY PACK AT HATCHED AREA, <br />SEE STRUCTURAL DRAWINGS DETAIL 9 / S1.2. <br />092116.C GYPSUM BOARD CEILING OVER (E) FRAMING,NEW GYPSUM BOARD <br />CEILING SHALL BE FRAMED WITH 2x6 FRAMING AT 16" O.C. (SHORT <br />DIRECTION OF CEILING). <br />095100.C SUSPENDED ACOUSTICAL CEILING TILES, SEE SHEET A/64.4 FOR <br />DETAILS <br />095110.A ADHERED DIRECT ATTACH ACOUSTICAL TECTUM CEILING, SEE <br />15/A64.4 <br />104400.C (E) FIRE EXTINGUISHER CABINET W/ EXTINGUISHER TO REMAIN <br />PROTECTED IN PLACE <br />104400.D (E) PULL BOX TO REMAIN PER FA DRAWINGS <br />116100.B (E) AED CABINET TO REMAIN PROTECTED IN PLACE <br />130000.B ROOF OF PC-APPROVED SHADE STRUCTURE. GENERAL <br />CONTRACTOR TO COORDINATE INSTALLATION OF PC SHADE <br />CANOPY <br />221000.E HI-LO ACCESSIBLE DRINKING FOUNTAIN, SEE PLUMBING <br />DRAWINGS DET. 3/GEN-4 AND DET. 12/A62.3 FOR ACCESSIBILITY <br />INFORMATION, 3/A62.3 AND 4/A62.3 FOR MOUNTING DETAILS <br />221000.K NEW FLOOR DRAIN, SEE PLUMBING PLANS DETAIL 1 / P11.2. <br />260000.C LIGHTING FIXTURE, SEE ELECTRICAL DRAWINGS <br />282300.B EXISTING VIDEO SECURITY SURVEILLANCE TO REMAIN PROTECTED <br />IN PLACE, TYP <br />1/8" = 1'-0"2IMPROVEMENT-REFLECTED CEILING PLAN <br />RCP LEGEND <br />KEYNOTES <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25 <br />3 ASI #03 07/02/25 <br />4 ASI #04 09/18/25 <br />4 <br />4 <br />4 <br />4 <br />4 <br />4 <br />4 <br />4 <br />4 <br />4