Laserfiche WebLink
DETAIL REFERENCE <br />DETAIL NUMBER 1 <br />A101SHEET ON WHICH DETAIL IS SHOWN <br />BUILDING SECTION REFERENCE <br />SECTION NUMBER 1 <br />A101SHEET ON WHICH SECTION IS SHOWN <br />INTERIOR ELEVATION REFERENCE <br />ELEVATION NUMBER 1 <br />A101SHEET ON WHICH ELEVATION IS <br />SHOWN <br />EXTERIOR ELEVATION REFERENCE <br />SHEET ON WHICH ELEVATION IS SHOWN A101 <br />DOOR REFERENCE 101 <br />WINDOW REFERENCE 1 <br />REVISIONS <br />1REVISION NUMBER <br />STOREFRONT REFERENCE <br />WALL TYPES A1.6 <br />GRIDLINE REFERENCE 1 <br />TOILET ROOM ACCESSORY SYMBOL 1 <br />MATERIAL REFERENCE 101 <br />View <br />Name <br />1/ A101 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />1 1/2" = 1'-0" <br />07/08/24 <br />GEN-2 <br />GENERAL NOTES <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />ABBREVIATIONS <br />A.B. ANCHOR BOLT (S) <br />A.C. ASPHALT CONCRETE PAVING <br />ACOUS ACOUSTIC <br />AC. T. ACOUSTICAL TILE <br />A.D. AREA DRAIN <br />ADJ. ADJUSTABLE <br />AGG AGGREGATE <br />ALT. ALTERNATE <br />ALUM. ALUMINUM <br />APPROX. APPROXIMATE <br />APT. APARTMENT <br />ASPH. ASPHALT <br />A.S.T.M. AMERICAN SOCIETY OF <br />TESTING MATERIALS <br />@ AT <br />B.B BOTTOM OF BEAM <br />BD. BOARD <br />BLK. BLOCK <br />BLK'G. BLOCKING <br />BM. BEAM <br />BOT. BOTTOM <br />BDRM. BEDROOM <br />BR. BROOM <br />CAB. CABINET <br />CPT. CARPET <br />C.B. CATCH BASIN <br />CEM. CEMENT <br />CEM. PLAS. CEMENT PLASTER <br />C. CENTER LINE <br />CER. CERAMIC <br />C.I. CAST IRON <br />CIRC. CIRCULAR <br />CLG. CEILING <br />CLR. CLEAR <br />C.M.T. CERAMIC MOSAIC TILE <br />COMPC. COMPOSITION <br />CONC. CONCRETE <br />CONT. CONTINUOUS <br />CTSK. COUNTERSUNK <br />CU. FT. CUBIC FEET <br />CU. IN. CUBIC INCH <br />CU. YD. CUBIC YARD <br />D. DRYER <br />D.F. DOUGLAS FIR <br />D.F. DRINKING FOUNTAIN <br />DIA. DIAMETER <br />DIM. DIMENSION <br />DN. DOWN <br />DR. DOOR <br />D.S. DOWN SPOUT <br />DSP. DRY STANDPIPE <br />DUP. DUPLICATE <br />DW. DISHWASHER <br />DWGS. DRAWINGS <br />E. EAST <br />EA. EACH <br />E.J. EXPANSION JOINT <br />ELEVA. ELEVATOR <br />ELEV. ELEVATION <br />ENCL. ENCLOSURE <br />EQ. EQUAL <br />EQUIP. EQUIPMENT <br />E.W.W.M. ELECTRIC WELDED WIRE MESH <br />EXPN. EXPANSION <br />EXP. EXPOSED <br />EXT. EXTERIOR <br />EXTR. EXTINGUISHER <br />FHS FLAT HEAD SCREW <br />F.A.U. FORCED AIR UNIT <br />F.F. FINISH FLOOR <br />F.G. FIXED GLASS <br />FHWS FLAT HEAD WOOD SCREW <br />FIN. FINISH <br />FIXT. FIXTURE <br />FLASH. FLASHING <br />FLR FLOOR <br />FLR'G FLOORING <br />FLUOR. FLUORESCENT <br />F.O.C. FACE OF CONCRETE <br />F.O.M. FACE OF MASONRY <br />F.O.S. FACE OF STUD <br />F.O.W. FACE OF WALL <br />F.P. FIRE PLACE <br />F.S. FINISH SURFACE <br />FREQ. FREQUENCY <br />FT. FEET, FOOT <br />FTG. FOOTING <br />FXC FIRE EXTINGUISHER & CABINET <br />GA. GAUGE <br />GALV. GALVANIZED <br />G.I. GALVANIZED IRON (STEEL) <br />GUN. FUNITE <br />GYP. GYPSUM <br />GYP. BD. GYPSUM BOARD <br />H.B. HOSE BIBB <br />H.C. HOLLOW CORE <br />HD DEAD <br />H.M. HOWLLOW METAL <br />HORIZ. HORIZONTAL <br />HR. HOUR <br />I. IRON <br />I.D. INSIDE DIAMETER <br />INC. INCORPORATED <br />INSUL. INSULATION <br />INT INTERIOR <br />JT. JOINT <br />JST. JOIST <br />K. KITCHEN <br />LAM. LAMINATED <br />LAM. PLAS. LAMINATED PLASTIC <br />LAV. LAVATORY <br />LT. LIGHT <br />LVR. LOUVER <br />M.C. MEDICINE CABINET <br />MECH. MECHANICAL <br />MEMB. MEMBRANE <br />MET. METAL <br />MFG. MANUFACTURE <br />M.H. MAN HOLE <br />MIN. MINIMUM <br />MIR. MIRROR <br />MTG. MOUNTING <br />MTL. METAL <br />N. NORTH <br />NAT. NATURAL <br />N.I.C. NOT IN CONTRACT <br />NO. NUMBER <br />N.T.S. NOT TO SCALE <br />O/ OVER <br />O.C. ON CENTER <br />O.D. OVERFLOW DRAIN <br />OPP. OPPOSITE <br />OV. OVEN <br />OVHD. OVERHEAD <br />PB. PUSHBUTTON <br />PC PULL CHAIN <br />PL PLATE <br />P PROPERTY LINE <br />PLAS. PLASTER <br />PL. GLS. PLATE GLASS <br />PLAST. PLASTER <br />PLYWD. PLYWOOD <br />PNL. PANEL <br />PR. PAIR <br />PRCST. PRECAST <br />PREFAB. PREFABRICATED <br />% [ERCEMT <br />QRY. QUARRY <br />QTY. QUANTITY <br />RAD. RADIUS <br />R. RISER <br />R.A.G. RETURN AIR GRILLE <br />RD. ROAD <br />R.D. ROOF DRAIN <br />RDWD. REDWOOD <br />RECP. RECEPTABLE <br />REF. REFERENCE <br />REF. REFRIGERATOR <br />REG. REGISTER <br />REINF. REINFORCEMENT <br />REQ'D REQUIRED <br />RES. FLR. RESILIENT FLOORING <br />RET. RETAINING <br />RF. ROOF <br />RF'G. ROOFING <br />RM. ROOM <br />RO. ROUGH <br />R.O. ROUGH OPENING <br />RUB. RUBBER <br />R.B. RUBBER (RESILIENT) BASE <br />S. SOUTH <br />S.C. SOLID CORE <br />S.D. STORM DRAIN <br />SHT. SHEET <br />SHT'G SHEATHING <br />SIM. SIMILAR <br />S&P SHELF AND POLE <br />SPECS. SPECIFICATIONS <br />SPRKL. SPRINKLER <br />SQ. IN. SQUARE INCH <br />SQ. FT. SQUARE FOOT <br />ST. STEEL <br />STOR. STORAGE <br />STRUCT. STRUCTURAL <br />SUSP. SUSPENDED <br />SIM. SIMILAR <br />S4S SMOOTH FOUR SIDES <br />T TREAD <br />T&B TOP AND BOTTOM <br />T.B. TOP OF BEAM <br />T.C. TOP OF CURB <br />T.C. TOP OF CONCRETE <br />T.G. TOP OF GRATE <br />TEL TELEPHONE <br />TEMP. TEMPERED <br />T&G TONGUE AND GROOVE <br />THK. THICK <br />THRESH THRESHOLD <br />T.P. TOP OF PAVING <br />T.S. TOP OF SHEATHING <br />T.W. TOP OF WALL <br />TYP. TYPICAL <br />UL UNDERWRITER'S LABEL <br />ULT. ULTIMATE <br />UNFIN. UNFINISHED <br />U.R.F. UNDER ROOF FRAMING <br />V.A.T. VINYL ASBESTOS TILE <br />VENT. VENTILATOR <br />VERT. VERTICAL <br />VIT. VITREOUS <br />VOL. VOLUME <br />V.T. VINYL TILE <br />W. WEST <br />W/ WITH <br />W.C. WATER CLOSET <br />WD. WOOD <br />W WIDE FLANGE (STEEL) <br />W.G. WIRE GLASS <br />W.H. WATER HEATER <br />W.I. WROUGHT IRON <br />W/O WITH OUT <br />WP. WATERPROOFING <br />WS WEATHERSTRIPPING <br />W.S.P. WET STANDPIPE <br />WT. WEIGHT <br />YD. YARD <br />ARCHITECTURAL SYMBOLS LEGENDGENERAL NOTES <br />1. SITE DEVELOPMENT <br />A. GRADE AND DEVELOP SITE SUCH THAT ALL PRIMARY BUILDING ENTRANCES ARE <br />ACCESSIBLE TO THE PHYSICALLY DISABLED FROM THE PUBLIC WAY AND DISABLED PARKING <br />PROVIDED. <br />B. ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, FACILITIES AND SPACES <br />ON THE SAME SITE. WHERE MORE THAN ONE ROUTE IS PROVIDED, ALL ROUTES SHALL BE <br />ACCESSIBLE <br />C. IF AN ACCESSIBLE ROUTE HAS A CHANGE IN LEVEL GREATER THAN 1/2", THEN A CURB RAMP, <br />RAMP, ELEVATOR, OR PLATFORM LIFT SHALL BE PROVIDED. <br />D. ALL WALKS, HALLS, CORRIDORS, AISLES, AND OTHER SPACES THAT ARE PART OF AN <br />ACCESSIBLE ROUTE SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 48 INCHES AND A CLEAR <br />HEIGHT OF 80 INCHES. <br />2. WALKS AND SIDEWALKS <br />A. WALKS AND SIDEWALKS SUBJECT TO THESE REGULATIONS SHALL HAVE A CONTINUOUS <br />COMMON SURFACE, NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL <br />EXCEEDING 1/2", AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH. <br />B. ALL SIDEWALKS SHALL BE STABLE, FIRM AND SLIP RESISTANT. <br />C. SURFACE CROSS SLOPES SHALL NOT EXCEED 1:48 (CBC 11B-403.3). <br />D. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATINGS WHENEVER <br />POSSIBLE. GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN <br />THE GRATING SHALL BE LIMITED TO 1/2" IN THE DIRECTION OF TRAFFIC FLOW. <br />E. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2". <br />WHEN CHANGES DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 <br />EXCEPT THAT LEVELS NOT EXCEEDING 1/4" MAY BE VERTICAL. <br />F. WHEN CHANGES IN LEVELS GREATER THAN 1/2" ARE NECESSARY THEY SHALL COMPLY WITH <br />THE REQUIREMENTS FOR CURB RAMPS OR RAMPS AS REQUIRED. <br />G. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60" SQUARE AT A DOOR <br />OR GATE THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48" WIDE BY 44" DEEP AT A <br />DOOR OR GATE THAT SWINGS AWAY FROM THE WALK. SUCH WALKS SHALL EXTEND 24" TO THE <br />SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK. <br />H. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 5%, IT MUST <br />COMPLY WITH THE PROVISIONS FOR PEDESTRIAN RAMPS (PER CBC 11B-405). <br />I. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS AT LEAST 5 FEET IN <br />LENGTH AT INTERVALS NOT EXCEEDING 400 FEET. <br />3. ENTRANCES AND DOORWAYS <br />A. PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO THE <br />DISABLED. <br />B. ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE "ISA" SIGN AND WITH <br />ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED VISIBLE FROM APPROACHING PEDESTRIAN <br />WAYS. <br />C. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND ARE IN THE PATH OF <br />TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC <br />BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE <br />WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. <br />D. HAND ACTIVATED DOOR HARDWARE SHALL BE CENTERED BETWEEN 34" AND 44" ABOVE THE <br />FLOOR (CBC 11B-404.2.7). <br />E. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE <br />LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL BE A MINIMUM 60" SQUARE IN THE <br />DIRECTION OF THE DOOR SWING AND A MINIMUM 44" SQUARE OPPOSITE THE DIRECTION OF <br />DOOR SWING (48" IF THE DOOR HAS BOTH LATCH AND CLOSER). THE SQUARES SHALL BE <br />MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. SEE NOTE <br />I BELOW FOR STRIKE SIDE REQUIREMENTS. <br />F. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS <br />SHALL EXTEND 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18" PAST <br />THE STRIKE EDGE FOR INTERIOR DOORS AND THE PRIMARY ENTRANCE TO THE DWELLING <br />UNIT. <br />G THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF <br />THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED NO GREATER <br />THAN 1:2. <br />H. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT SLIDING AND POCKET DOORS SHALL HAVE A <br />SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR <br />FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. <br />I. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS FOR EXTERIOR DOORS <br />AND 5 LBS FOR INTERIOR DOORS, SUCH PULL OR PUSH EFFORT SHALL BE APPLIED AT RIGHT <br />ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. <br />COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE <br />ABOVE STANDARDS. THE AUTHORITY HAVING JURISDICTION MAY INCREASE THE MAXIMUM <br />EFFORT TO OPERATE FIRE DOORS TO ACHIEVE POSITIVE LATCHING, BUT NOT TO EXCEED 15 <br />LBS MAX. <br />J. EXIT DOORS MUST OPEN FROM THE INSIDE WITHOUT A KEY, OR ANY SPECIAL KNOWLEDGE <br />OR EFFORT. EXIT DOORS FROM BUILDINGS OR ROOMS SERVING 10 OR FEWER OCCUPANTS <br />MAY HAVE A NIGHT LATCH, DEADBOLT OR SECURITY CHAIN, AS LONG AS THE DOORS CAN STILL <br />BE OPENED FROM THE INSIDE WITHOUT A KEY, SPECIAL KNOWLEDGE OR EFFORT. IN ADDITION, <br />THESE DEVICES ARE NOT MOUNTED MORE THAN 48" ABOVE THE FLOOR. MANUALLY OPERATED <br />EDGE BOLTS, SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. WHEN <br />EXIT DOORS ARE USED IN PAIRS AND AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF <br />WITH THE FLUSH BOLT MUST HAVE NO DOORKNOB OR SURFACE MOUNTED HARDWARE. THE <br />UNLATCHING OF ANY LEAF MUST NOT REQUIRE MORE THAN ONE OPERATION. <br />K. EVERY REQUIRED EXIT MUST BE LARGE ENOUGH TO PERMIT A DOOR AT LEAST 3'-0" WIDE BY <br />6'-8" HIGH. EXIT DOORS SHALL OPEN AT LEAST 90 DEGREES AND PROVIDE A CLEAR WIDTH OF <br />AT LEAST 32". <br />L. THRESHOLDS AT ALL EXTERIOR DOORS SHALL BE NO HIGHER THAN 1/2". SUCH THRESHOLDS <br />SHALL BE BEVELED NO GREATER THAN 1:2. <br />M. THE FLOOR LANDING IMMEDIATELY OUTSIDE THE ENTRY MAY BE SLOPED UP TO 1/8" PER <br />FOOT IN THE DIRECTION AWAY FROM THE PRIMARY ENTRANCE FOR DRAINAGE. <br />N. THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING <br />OTHER THAN A REQUIRED EXIT STAIRWAY, MUST HAVE AT LEAST 48" OF CLEAR SPACE FROM <br />ANY DOOR OPENING INTO THE VESTIBULE WHEN THE DOOR IS OPEN 90 DEGREES FROM ITS <br />CLOSED POSITION. DOORS IN SERIES MUST SWING IN THE SAME DIRECTION OR AWAY FROM <br />THE SPACE BETWEEN THE DOORS. <br />4. STAIRWAYS <br />A. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. STAIRWAYS SHALL HAVE <br />INTERMEDIATE HANDRAILS WHERE REQUIRED SUCH THAT ALL PORTIONS OF THE STAIRWAY <br />WIDTH REQUIRED FOR EGRESS CAPACITY ARE WITHIN 30 INCHES OF A HANDRAIL. <br />INTERMEDIATE HANDRAILS SHALL BE SPACED AT EQUAL INTERVALS WITHIN THE WIDTH OF <br />THE STAIRWAY AND BE CONTINUOUS FOR THE ENTIRE LENGTH. <br />B. HANDRAILS MUST BE 34 TO 38 INCHES ABOVE THE NOSING OF THE TREADS AND MUST <br />EXTEND IN THE DIRECTION OF THE STAIR RUN FOR AT LEAST 12" BEYOND THE TOP NOSING <br />AND 12" PLUS THE TREAD WIDTH BEYOND THE BOTTOM NOSING. <br />C. ENDS SHALL BE RETURNED OR SHALL TERMINATE IN A NEWEL POST OR SAFETY <br />TERMINAL. <br />D. HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2- <br />INCH BETWEEN THE WALL AND THE HANDRAIL. <br />E. THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4-INCHES NOR <br />MORE THAN 1 1/2-INCHES IN CROSS-SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE <br />AN EQUIVALENT GRIPPING SURFACE AND SHALL HAVE A SMOOTH SURFACE WITH NO SHARP <br />OR ABRASIVE CORNERS AND ALL EDGES MUST HAVE A MINIMUM 1/8" RADIUS. <br />F. THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR SHALL BE <br />MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR THE FULL WIDTH OF THE TREAD AT <br />LEAST 2-INCHES WIDE PLACED PARALLEL TOAND NOT MORE THAN 1-INCH FROM THE NOSE OF <br />THE STEP OR LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A <br />MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. <br />G. WHERE STAIRWAYS OCCUR OUTSIDE A BUILDING, THE UPPER APPROACH AND ALL <br />TREADS SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2- <br />INCHES WIDE AND PLACED PARALLEL TO AND NOT MORE THAN 1-INCH FROM THE NOSE OF <br />THE STEP OR LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A <br />MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A <br />PAINTED STRIP SHALL BE ACCEPTABLE. <br />H. ALL TREAD SURFACES SHALL BE SLIP RESISTANT. <br />I. TREADS SHALL HAVE A SMOOTH, ROUNDED OR CHAMFERED EXPOSED EDGES, AND NO <br />ABRUPT EDGES AT THE NOSING (LOWER FRONT EDGE). <br />J. NOSING SHALL NOT PROJECT MORE THAN 1-1/4 INCH PAST THE FACE OF THE RISER <br />BELOW. <br />K. STAIR RISERS SHALL BE SOLID PER CBC 11B-504. <br />5. SANITARY FACILITIES <br />A. WHEELCHAIR ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A <br />DOOR THAT HAS AN AUTOMATIC CLOSING DEVICE, AND SHALL HAVE A CLEAR <br />UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WHEN LOCATED AT THE END AND 34-INCHES <br />WHEN LOCATED AT THE SIDE WITH THE DOOR POSITION AT AN ANGLE OF 90 DEGREES FROM <br />ITS CLOSED POSITION. <br />B. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE <br />TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR FLUSH VALVES <br />SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44-INCHES <br />ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER <br />THAN 5 POUNDS PER FOOT. <br />C. WHERE URINALS ARE PROVIDED AT LEAST ONE WITH A RIM PROJECTING A MINIMUM OF 14- <br />INCHES FROM THE WALL AND AT A MAXIMUM OF 17-INCHES ABOVE THE FLOOR SHALL BE <br />PROVIDED. <br />D. URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT <br />REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST AND SHALL BE MOUNTED <br />NO MORE THAN 44" ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS <br />SHALL BE NO GREATER THAN 5 POUNDS PER FOOT. <br />E. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE <br />COVERED. <br />F. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND <br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE <br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER <br />FOOT. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE <br />EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET <br />REMAINS OPEN FOR AT LEAST 10 SECONDS. <br />G. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM GLASS EDGE NOT MORE THAN 40- <br />INCHES ABOVE THE FLOOR. <br />H. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL OPERABLE <br />PARTS NOT MORE THAN 40-INCHES FROM THE FLOOR. <br />I. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL OR PARTITION WITHIN 7" TO <br />9" TO CENTERLINE FROM THE FRONT EDGE OF THE TOILET SEAT, MOUTED BELOW THE GRAB <br />BAR, AT A MINIMUM HEIGHT OF 19 INCHES, AND 36 INCHES MAXIMUM TO THE FAR EDGE FROM <br />THE REAR WALL. DISPENSERS SHALL PERMIT CONTINUOUS FLOW AND NOT CONTROL <br />DELIVERY (CBC 11B-604.7). <br />J. GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVICES SHALL BE <br />DESIGNED FOR 250 LB. PER CBC 1607A.8.2. <br />K. GRAB BARS: <br />1. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACE OF A GRAB BAR SHALL BE <br />1-1/4" TO 1-1/2" OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. <br />2. IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN <br />THE WALL AND THE GRAB BARS SHALL BE 1-1/2". <br />3. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT SHALL BE FREE OF <br />ANY SHARP OR ABRASIVE ELEMENTS. <br />4. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br />5. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". <br />6. SWITCHES CONTROLS AND ELECTRICAL OUTLETS <br />A. RECEPTACLE OUTLETS SHALL BE 15" MIN ABOVE THE FINISHED FLOOR TO THE BOTTOM OF <br />THE BOX PER CBC 11B-308.1.2. <br />B. SWITCHES SHALL BE 48" MAX. ABOVE THE FINISHED FLOOR TO THE TOP OF THE BOX <br />(11B-308.1.1). <br />C. IF REACH IS OVER AN OBSTRUCTION ( FOR EXAMPLE, A BASE CABINET ) BETWEEN 20" AND <br />25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH, OR 46" <br />FOR SIDE APPROACH PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. THE <br />OBSTRUCTION MAY NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH THE CONTROL. <br />D. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" ABOVE <br />THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. <br />E. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED THEY SHALL ACTIVATE A MEANS OF <br />WARNINGTHE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY <br />OF NOT MORE THAN 60 FLASHES PER MINUTE. <br />1. THESE DOCUMENTS AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN <br />INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SVA ARCHITECTS, <br />AND ARE NOT TO BE USED, IN WHOLE OR IN PART FOR ANOTHER PROJECT WITHOUT <br />THE WRITTEN AUTHORIZATION OF SVA ARCHITECTS. <br />2. THE WORK SHOWN ON THESE DRAWINGS AS EXISTING CONDITIONS WAS <br />PREPARED FROM INFORMATION FURNISHED BY THE OWNER. WHILE THIS <br />INFORMATION IS BELIEVED TO BE RELIABLE, SVA ARCHITECTS INC. IS NOT <br />RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OF ANY WORK SHOWN AS EXISTING <br />NOR IS SVA ARCHITECTS INC. RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH <br />MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. <br />3. EACH BIDDER SHALL POSSESS AT THE TIME OF BID A CLASS B OR THE <br />APPROPRIATE CLASS C CONTRACTOR'S LICENSE PURSUANT TO PUBLIC CONTRACT <br />CODE SECTION 3300 AND BUSINESS AND PROFESSIONS CODE SECTION 7028.15. THE <br />SUCCESSFUL BIDDER MUST MAINTAIN THE LICENSE THROUGHOUT THE DURATION OF <br />THIS CONTRACT. <br />4. FIRE SAFETY DURING CONSTRUCTION AND THE DURATION OF THIS CONTRACT: <br />A. GENERAL: FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH 2022 <br />CALIFORNIA FIRE CODE TITLE 24, PART 9, CHAPTER 33. <br />B. ACCESS ROADS: FIRE DEPARTMENT ACCESS ROADS SHALL BE ESTABLISHED AND <br />MAINTAINED IN ACCORDANCE WITH SECTION C.F.C SECTION 3311. <br />C. WATER SUPPLY: WATER MAINS AND HYDRANTS SHALL BE OPERATIONAL IN <br />ACCORDANCE WITH C.F.C SECTION 3311. <br />D. BUILDING ACCESS: ACCESS TO BUILDINGS FOR THE PURPOSE OF FIREFIGHTING <br />SHALL BE PROVIDED. CONSTRUCTION MATERIAL SHALL NOT BLOCK ACCESS TO <br />BUILDINGS, HYDRANTS OR FIRE APPLIANCES. <br />E. ALTERATIONS OF BUILDINGS: SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />SECTIONS 1405, 1411, 1413, AND 1415. <br />G. FIRE WATCH: MAINTAIN FIRE WATCH WHEN REQUIRED BY THE BUILDING OFFICIAL <br />AND WHEN EXISTING FIRE PROTECTION SYSTEMS ARE SHUT DOWN FOR ALTERATIONS. <br />FIRE WATCH SHALL REMAIN IN EFFECT UNTIL EXISTING FIRE PROTECTION SYSTEMS <br />ARE RETURNED TO SERVICE OR AS ALLOWED BY THE BUILDING OFFICIAL. <br />5. NOT USED <br />6. STATEMENT (TITLE 24, PART 6): NONRESIDENTIAL ENERGY STANDARDS <br />COMPLIANCE: THE DESIGN INDICATED HEREIN COMPLIES WITH THE REQUIREMENTS OF <br />THE ENERGY CONSERVATION STANDARDS OF TITLE 24, PART 6, CALIFORNIA CODE OF <br />REGULATIONS. THE PROPOSED BUILDING WILL BE IN COMPLIANCE WITH THE ENERGY <br />CONSERVATION STANDARDS PROVIDED IT IS BUILT ACCORDING TO THESE DRAWINGS <br />AND SPECIFICATIONS AND PROVIDED ANY FUTURE IMPROVEMENTS ARE COMPLETED <br />ACCORDING TO THE REQUIREMENTS OF TITLE 24, PART 6, CALIFORNIA CODE OF <br />REGULATIONS. THESE PLANS AND SPECIFICATIONS HAVE BEEN PREPARED TO INCLUDE <br />ALL SIGNIFICANT ENERGY CONSERVATION FEATURES REQUIRED FOR COMPLIANCE <br />WITH THE STANDARDS. BUILDING AREAS THAT ARE UNCONDITIONED AND/OR NOT <br />SUBJECT TO THE STANDARDS ARE INDICATED ON THE PLANS. <br />ENVELOPE MANDATORY MEASURES: <br />A. INSTALLED INSULATING MATERIALS SHALL HAVE BEEN CERTIFIED BY THE <br />MANUFACTURER TO COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR <br />INSULATING MATERIAL. <br />B. ALL INSULATING MATERIALS SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME <br />SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF [TITLE 24, PART 2, <br />CALIFORNIA BUILDING CODE, SECTIONS 720 AND 803.] <br />C. ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE THAT ARE <br />POTENTIAL AND OBSERVABLE SOURCES OF AIR LEAKAGE SHALL BE CAULKED, <br />GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED. <br />D. SITE CONSTRUCTED DOORS, AND WINDOWS SHALL BE CAULKED BETWEEN THE UNIT <br />AND THE BUILDING, AND SHALL BE WEATHERSTRIPPED (EXCEPT FOR UNFRAMED <br />GLASS DOORS AND FIRE DOORS). <br />E. MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION <br />RATES CERTIFIED BY THE MANUFACTURER IN ACCORDANCE WITH TITLE 24, PART 6, <br />CALIFORNIA CODE OF REGULATIONS, SECTION 116(a)1. <br />F. MANUFACTURED FENESTRATION PRODUCTS IN THE ENVELOPE OF THE BUILDING, <br />INCLUDING, BUT NOT LIMITED TO, WINDOWS, SLIDING GLASS DOORS, FRENCH DOORS, <br />SKYLIGHTS, CURTAIN WALLS, AND GARDEN WINDOWS MUST BE LABELED FOR U-VALUE <br />IN ACCORDANCE WITH THE (NFRC) NATIONAL FENESTRATION RATING COUNCIL'S <br />INTERIM U-VALUE RATING PROCEDURE. <br />G. NOT USED. <br />7. INSPECTOR OF RECORD REQUIREMENTS: A. ONE OR MORE INSPECTORS <br />EMPLOYED BY THE OWNER IN ACCORDANCE WITH THE REQUIREMENTS OF TITLE 24 <br />PART 1 OF THE CALIFORNIA CODE OF REGULATIONS WILL BE ASSIGNED TO THE WORK. <br />THE INSPECTORS DUTIES ARE SPECIFICALLY DEFINED IN SECTION 4-342 OF SAID TITLE <br />24, PART 1 AND IN ADDITION SHALL BE AS STIPULATED IN INTERPRETATION OF <br />REGULATION DOCUMENT IR A-8. B. INSPECTOR SHALL BE CERTIFIED AS A CLASS [2] <br />INSPECTOR. INSPECTOR SHALL ALSO BE SPECIFICALLY APPROVED BY THE BUILDING <br />DEPARTMENT FOR THIS PROJECT AT LEAST 10 DAYS PRIOR TO THE START OF ANY <br />WORK FOR THIS PROJECT. <br />8. ALL WORK SHOWN ON THESE DRAWINGS SHALL COMPLY WITH THE REQUIREMENTS <br />OF TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR). <br />9. CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY <br />AN ADDENDUM OR A CCD APPROVED BY THE BUILDING DEPARTMENT. <br />10. GRADING PLANS, DRAINAGE IMPRPOVEMENTS, ROAD AND ACCESS REQUIREMENTS <br />AND ENVIROMENTAL HEALTH CONCIDERATIONS SHALL COMPLY WITH ALL LOCAL <br />ORDINANCES. <br />11. DRINKING WATER SHALL COMPLY WITH ALL LOCAL HEALTH DEPARTMENT <br />REQUIREMENTS. <br />12. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE <br />APPLICABLE CODES. ALL ENGINEERING SHALL COMFORM WITH ALL APPLICABLE <br />MUNICIPAL, STATE AND FEDERAL REGULATIONS HAVING JURISDICTION INCLUDING <br />ACCESSIBILITY STANDARDS AND ADA REQUIREMENTS. <br />13. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE. <br />THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD <br />PRIOR TO BIDDING AND START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE <br />ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING WORK. <br />14. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF MASONRY UNITS, <br />CENTERLINE OF COLUMNS AND BEAMS, OR FACE OF STUDS, UNLESS OTHERWIS <br />NOTED. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB OR TOP OF <br />INTERIOR PAVING UNLESS NOTED OTHERWISE. CEILING HEIGHT DIMENSIONS ARE TO <br />FINISHED SURFACES UNLESS NOTED OTHERWISE. <br />15. THE CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS <br />ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL <br />DRAWINGS BEFORE PROCEEDING WITH INSTALLATION OF CIVIL, STRUCTURAL <br />MECHANICAL, PLUMBING, AND ELECTRICAL WORK. SHOULD THERE BE ANY <br />DISCREPANCIES BETWEEN THE ARCHITECT'S AND THE CONSULTING ENGINEER'S <br />DRAWINGS AND SPECIFICATIONS THAT WOULD CAUSE A CONFLICT, IT SHALL BE <br />BROUGHT TO THE ARCHITECTS ATTENTION FOR CLARIFICATION PRIOR TO <br />INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE <br />ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS <br />EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT. <br />16. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO <br />BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING <br />ABBREVIATIONS OR THEIR EXACT MEANING, THE ARCHITECT SHALL BE NOTIFIED FOR <br />CLARIFICATION. <br />17. DETAILS AND NOTES MARKED "TYPICAL" SHALL APPLY IN ALL SIMILAR CASES <br />UNLES SPECIFICALLY INDICATED OTHERWISE. <br />18. THE BID DOCUMENTS ARE COMPRISED OF THE DRAWINGS, PROJECT MANUAL <br />GENERAL CONDITIONS, GENERAL REQUIREMENTS AND TECHNICAL SPECIFICATIONS <br />AND ALL SUPPLEMENTAL DOUCMENTS (BID ADDENDA, ETC.). THE GENERAL <br />CONTRACTOR IS EXPECTED TO READ ALL DOCUMENTS AND BECOME FAMILIAR WITH <br />THE CONTENT CONTAINED WITHIN THESE DOCUMENTS. IF DISCREPANCIES OCCUR <br />BETWEEN DIFFERENT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER AND <br />THE ARCHITECT TO REQUEST CLARIFICATION. SVA ARCHITECTS, INC. AND THEIR <br />ENGINEERS ARE THE AUTHORS OF THESE DOCUMENTS AND WILL PROVIDE <br />CLARIFICATIOIN WHERE NECESSARY. <br />19. THESE DOCUMENTS WERE PREPARED BASED ON AS-BUILT DOCUMENTS PROVIDED <br />BY THE OWNER AND SITE OBSERVATIONS MADE BY THE DESIGN TEAM. THE <br />CONTRACTOR SHALL FIELD VERIFY ALL FIELD CONDTIONS PRIOR TO PREPARING SHOW <br />DRAWINGS FOR REVIEW. <br />20. 2X WOOD BLOCKING AND/OR METAL STUD BLOCKING SHALL BE PROVIDED IN ALL <br />WALLS WHERE EQUIPMENT, ACCESSORIES AND/OR CABINETS ARE SHOWN TO BE <br />MOUNTED TO THE WALLS. ALL AFFECTED AREAS REQURIED TO BE OPENED UP TO <br />INSTALL SUCH BLOCKING SHALL BE PATCHED AND REPAIRED TO MATCH ADJOINING <br />SURFACE TEXTURE AND FINISHES <br />21. WHERE DOMOLITION IS SHOWN OR DESCRIBED IN NOTES ON THE DRAWINGS, SUCH <br />ITEMS SHALL INCLUDE ALL SYSTEMS WITHIN THE DEMOLISHED ITEM. FOR INSTANCE, <br />WALL DEMOLITION SHALL INCLUDE THE CURB, FINISHES ON EACH SIDE AND <br />ELECTRICAL AND/OR PLUMBING COMPONENTS WITHIN. PLUMBING AND/OR ELECTRICAL <br />SYSTEMS WITHIN DEMOLISHED COMPONENTS SHALL BE COORDINATED WITH <br />RESPECTIVE DRAWINGS FOR RE-ROUTING OR CAPPING SYSTEMS. <br />18. ALL RUBBISH AND DEBRIS RESULTING FROM DEMOLITION AND/OR NEW WORK SHALL BE <br />DISPOSED OF OFF-SITE DAILY AND SHALL NOT BE ALLOWED TO ACCUMULATE. <br />19. SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH SECTION 01 30 00 OF SPECIFICATIONS AND AS <br />REQUIRED BY INDIVIDUAL SPECIFICATION SECTIONS. <br />20. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL PRIOR TO BID. <br />REQUEST FOR SUBSTITUTION SHALL BE IN ACCORDANCE WITH SECTION 01 60 00 OF SPECIFICATIONS. <br />21. NOT USED <br />22. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE FLUSH. <br />23. NOT USED <br />24. NOT USED <br />25. INSTALL METAL CORNER BEADS AT ALL EXPOSED GYPSUM BOARD EDGES INSTALL CASING BEADS <br />WHEREVER GYPSUM BOARD, PLASTER, ETC. ABUTS DISSIMILAR FINISH MATERIAL AND PROVIDE <br />SEALANT AS REQUIRED. <br />26. GYPSUM BOARD SHALL EXTEND TO UNDERSIDE OF STRUCTURE ABOVE AT ALL COLUMNS AND <br />EXTERIOR PERIMETER WALLS UNLESS OTHERWISE NOTED. <br />27. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES, AND <br />SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, STAIR RAILINGS, <br />TOILET ROOM ACCESSORIES AND PARTITIONS, AND OF ALL WALL MOUNTED OR SUSPENDED <br />MECHANICAL, ELECTRICAL, OR MISCELLANEOUS EQUIPMENT. <br />28. ALL GLAZING SHALL COMPLY WITH THE CONSUMER PRODUCT SAFETY COMMISSION <br />REQUIREMENTS (C.P.S.C.), CFC, AND CBC. <br />29. CONTACT BETWEEN DISSIMILAR METAL SHALL BE PROTECTED AGAINST GALVANIC CORROSION. <br />30. ALL DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR <br />THRESHOLDS, ETC. SHALL BE TAKEN OFF DOOR. ALL DOORS AND FRAME SHALL BE REINFORCED <br />WHERE REQUIRED FOR CLOSERS, STOPS, AND HARDWARE. <br />31. ROOFING SYSTEM SHALL BEAR U.L. LISTING AS A CLASS "A" SYSTEM. ALL MANUFACTURED <br />MATERIALS USED SHALL BEAR THE APPROPRIATE U.L. LABEL. <br />32. ALL WOOD TRIM, SPACER, FILLER, ETC., THROUGHOUT JOB SHOULD BE FIRE TREATED. <br />33. INSPECTION AND TESTING LABORATORY MUST BE IN THE EMPLOY OF THE OWNER, NOT THE <br />CONTRACTOR. <br />34. NOT USED <br />35. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY <br />SPECIAL KNOWLEGE. LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. <br />36. EXIT SIGNS SHALL HAVE 6" MINIMUM HEIGHT LETTERS AND SHALL CONFORM TO SECTION 1013 OF <br />THE CALIFORNIA BUILDING CODE. <br />37. FURNISH AND INSTALL ACCESS DOORS, FIRE DAMPERS, ETC. IN CEILING AND WALL <br />CONSTRUCTION LOCATED AS REQUIRED BY INSTALLATION OF MECHANICAL PLUMBING, AND <br />ELECTRICAL WORK AND AS APPROVED BY THE ARCHITECT. PROVIDE RATED ASSEMBLIES IN RATED <br />WALLS AND CEILINGS AND SHALL BE APPROVED BY BUILDING INSPECTOR PRIOR TO INSTALLATION. <br />38. FURNISH AND INSTALL EMERGENCY LIGHTING AS SPECIFIED AND INDICATED BUT IN NO CASE <br />SHALL THE LIGHT VALUE BE LESS THAN ONE FOOT CANDLE AT FLOOR LEVEL IN ALL EXIT CORRIDORS <br />AND STAIR SHAFTS (CBC SECTION 1008). <br />39. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH INTO WHICH A PERSON IS <br />REQUIRED TO DECEND UNLESS A PERMIT IS OBTAINED FROM THE STATE OF CALIFORNIA DIVISION OF <br />INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING PERMIT. <br />40. NOT USED. <br />41. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 18" OF THE ADJACENT <br />FLOOR SHALL BE GLASS APPROVED FOR IMPACT HAZARD. <br />42. ALL LIGHT GAUGE METAL STUDS AND BRACING SHALL COMPLY WITH 2016 CALIFORNIA BUILDING <br />CODE. <br />43. IF OCCURS, INSTALLATION OF SHORING, UNDERPINNING, AND/OR SLOT CUTTING EXCAVATIONS <br />SHALL BE PERFORMED UNDER THE CONTINUOUS INSPECTION AND APPROVAL OF THE GEOTECHNICAL <br />ENGINEER. <br />44. ALL CONSTRUCTION SHALL PERFORMED IN ACCORDANCE WITH THE STATE CONSTRUCTION <br />SAFETY ORDERS ENFORCED BY THE STATE DIVISION OF INDUSTRIAL SAFETY. <br />45. DIMENSIONS AND CONDITIONS AT THE JOB SITE SHALL BE VERIFIED BY ALL CONTRACTORS. IT IS <br />THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE EXISTING CONDITIONS PRIOR TO <br />SUBMITTING BIDS TO THE OWNER SINCE PROPOSALS MUST TAKE INTO CONSIDERATION ALL SUCH <br />CONDITIONS THAT MAY AFFECT THE WORK. DISCREPANCIES IN THE DRAWINGS OR BETWEEN THE <br />DRAWINGS AND ACTUAL FIELD CONDITION SHALL BE REPORTED TO THE ARCHITECT. REVISED <br />DRAWINGS OR INSTRUCTIONS SHALL BE ISSUED BY THE OWNER PRIOR TO THE INSTALLATION OF ANY <br />WORK. <br />46. CONTRACTORS SHALL PROVIDE AND INSTALL ALL CONCRETE HOUSEKEEPING PADS FOR <br />MECHANICAL AND ELECTRICAL EQUIPMENT, AS REQUIRED. <br />47. ALL GYPSUM WALL BOARD TO BE 5/8" THICK TYPE 'X' UNLESS OTHERWISE NOTED OR REQUIRED <br />FOR SPECIFIC WALL CONSTRUCTION. <br />48. THERMAL INSULATION SHALL BE PROVIDED PER TYPICAL ASSEMBLIES NOTED ON DRAWINGS. <br />REFER TO SPECS FOR PRODUCT INFORMATION. <br />49. PROVIDE SAFETY GLASS AT LOCATIONS REQUIRED BY CBC SECTION 2406 AND BY OTHER <br />APPLICABLE CODE. <br />50. ROOF DRAINS DISCHARGING WATER MUST BE CONDUCTED UNDER THE SIDEWALK <br />51. DOORS SHALL NOT PROJECT MORE THAN 7 INCHES INTO THE REQUIRED CORRIDOR WIDTH WHEN <br />FULLY OPENED OR MORE THAN ONE HALF INTO THE REQUIRED WIDTH WHEN IN ANY POSITION. (CBC <br />SECTION 1005.7.1) <br />52. PUBLIC HALLWAYS AND EXIT COURT PASSAGEWAYS TO HAVE 7'-0" CLEAR HEIGHT TO LOWEST <br />PROJECTION. (CBC SECTION 1005.3) <br />53. OCCUPANCY LOAD SIGNS SHALL BE POSTED IN EACH CLASSROOM, ASSEMBLY ROOM, OR SIMILAR <br />PURPOSE ROOM, HAVING AN OCCUPANT LOAD OF 50 OR MORE. <br />54. NOT USED <br />55. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF <br />THE ARCHITECT/ENGINEER WHOSE SIGNATURE APPEARS HEREON. <br />56. THESE DRAWINGS DO NOT CONTAIN THE NECESSARY COMPONENTS FOR CONSTRUCTION <br />SAFETY. <br />57. LOCATIONS OF ALL UTILITIES SHOWN ARE APPROXIMATE AND CONTRACTOR SHALL EXERCISE <br />EXTREME CAUTION IN EXCAVATING AND TRENCHING ON THIS SITE TO AVOID INTERCEPTING EXISTING <br />PIPING OR CONDUITS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL <br />EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE <br />ARCHITECT IS NOT RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES <br />WHETHER OR NOT SHOWN OR DETAILED AND INSTALLED BY ANY OTHER CONTRACT. THE <br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT SHOULD ANY UNIDENTIFIED CONDITIONS <br />BE DISCOVERED. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF <br />UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE <br />PROSECUTION OF THIS WORK. <br />58. THE PROJECT APPLICANT SHALL COMPLY WITH THE REQUIREMENTS OF THE ENGINEERING <br />DIVISION FOR ALL PUBLIC IMPROVEMENTS. <br />ACCESSIBILITY NOTES <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1