DETAIL REFERENCE
<br />DETAIL NUMBER 1
<br />A101SHEET ON WHICH DETAIL IS SHOWN
<br />BUILDING SECTION REFERENCE
<br />SECTION NUMBER 1
<br />A101SHEET ON WHICH SECTION IS SHOWN
<br />INTERIOR ELEVATION REFERENCE
<br />ELEVATION NUMBER 1
<br />A101SHEET ON WHICH ELEVATION IS
<br />SHOWN
<br />EXTERIOR ELEVATION REFERENCE
<br />SHEET ON WHICH ELEVATION IS SHOWN A101
<br />DOOR REFERENCE 101
<br />WINDOW REFERENCE 1
<br />REVISIONS
<br />1REVISION NUMBER
<br />STOREFRONT REFERENCE
<br />WALL TYPES A1.6
<br />GRIDLINE REFERENCE 1
<br />TOILET ROOM ACCESSORY SYMBOL 1
<br />MATERIAL REFERENCE 101
<br />View
<br />Name
<br />1/ A101
<br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS
<br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF
<br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY
<br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR
<br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA
<br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018.
<br />SCALE:
<br />REVISIONS:
<br />OW
<br />N
<br />E
<br />R
<br />:
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />
<br />N
<br />A
<br />M
<br />E
<br />:
<br />CL
<br />I
<br />E
<br />N
<br />T
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />:
<br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707
<br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM
<br />DATE ISSUED:
<br />PROJECT NO:
<br />1 1/2" = 1'-0"
<br />07/08/24
<br />GEN-2
<br />GENERAL NOTES
<br />2022-40123
<br />CI
<br />T
<br />Y
<br />
<br />O
<br />F
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />NE
<br />W
<br />H
<br />O
<br />P
<br />E
<br />
<br />L
<br />I
<br />B
<br />R
<br />A
<br />R
<br />Y
<br />MO
<br />D
<br />E
<br />R
<br />N
<br />I
<br />Z
<br />A
<br />T
<br />I
<br />O
<br />N
<br />12
<br />2
<br />
<br />N
<br />.
<br />
<br />N
<br />E
<br />W
<br />H
<br />O
<br />P
<br />E
<br />
<br />S
<br />T
<br />.
<br />,
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />ABBREVIATIONS
<br />A.B. ANCHOR BOLT (S)
<br />A.C. ASPHALT CONCRETE PAVING
<br />ACOUS ACOUSTIC
<br />AC. T. ACOUSTICAL TILE
<br />A.D. AREA DRAIN
<br />ADJ. ADJUSTABLE
<br />AGG AGGREGATE
<br />ALT. ALTERNATE
<br />ALUM. ALUMINUM
<br />APPROX. APPROXIMATE
<br />APT. APARTMENT
<br />ASPH. ASPHALT
<br />A.S.T.M. AMERICAN SOCIETY OF
<br />TESTING MATERIALS
<br />@ AT
<br />B.B BOTTOM OF BEAM
<br />BD. BOARD
<br />BLK. BLOCK
<br />BLK'G. BLOCKING
<br />BM. BEAM
<br />BOT. BOTTOM
<br />BDRM. BEDROOM
<br />BR. BROOM
<br />CAB. CABINET
<br />CPT. CARPET
<br />C.B. CATCH BASIN
<br />CEM. CEMENT
<br />CEM. PLAS. CEMENT PLASTER
<br />C. CENTER LINE
<br />CER. CERAMIC
<br />C.I. CAST IRON
<br />CIRC. CIRCULAR
<br />CLG. CEILING
<br />CLR. CLEAR
<br />C.M.T. CERAMIC MOSAIC TILE
<br />COMPC. COMPOSITION
<br />CONC. CONCRETE
<br />CONT. CONTINUOUS
<br />CTSK. COUNTERSUNK
<br />CU. FT. CUBIC FEET
<br />CU. IN. CUBIC INCH
<br />CU. YD. CUBIC YARD
<br />D. DRYER
<br />D.F. DOUGLAS FIR
<br />D.F. DRINKING FOUNTAIN
<br />DIA. DIAMETER
<br />DIM. DIMENSION
<br />DN. DOWN
<br />DR. DOOR
<br />D.S. DOWN SPOUT
<br />DSP. DRY STANDPIPE
<br />DUP. DUPLICATE
<br />DW. DISHWASHER
<br />DWGS. DRAWINGS
<br />E. EAST
<br />EA. EACH
<br />E.J. EXPANSION JOINT
<br />ELEVA. ELEVATOR
<br />ELEV. ELEVATION
<br />ENCL. ENCLOSURE
<br />EQ. EQUAL
<br />EQUIP. EQUIPMENT
<br />E.W.W.M. ELECTRIC WELDED WIRE MESH
<br />EXPN. EXPANSION
<br />EXP. EXPOSED
<br />EXT. EXTERIOR
<br />EXTR. EXTINGUISHER
<br />FHS FLAT HEAD SCREW
<br />F.A.U. FORCED AIR UNIT
<br />F.F. FINISH FLOOR
<br />F.G. FIXED GLASS
<br />FHWS FLAT HEAD WOOD SCREW
<br />FIN. FINISH
<br />FIXT. FIXTURE
<br />FLASH. FLASHING
<br />FLR FLOOR
<br />FLR'G FLOORING
<br />FLUOR. FLUORESCENT
<br />F.O.C. FACE OF CONCRETE
<br />F.O.M. FACE OF MASONRY
<br />F.O.S. FACE OF STUD
<br />F.O.W. FACE OF WALL
<br />F.P. FIRE PLACE
<br />F.S. FINISH SURFACE
<br />FREQ. FREQUENCY
<br />FT. FEET, FOOT
<br />FTG. FOOTING
<br />FXC FIRE EXTINGUISHER & CABINET
<br />GA. GAUGE
<br />GALV. GALVANIZED
<br />G.I. GALVANIZED IRON (STEEL)
<br />GUN. FUNITE
<br />GYP. GYPSUM
<br />GYP. BD. GYPSUM BOARD
<br />H.B. HOSE BIBB
<br />H.C. HOLLOW CORE
<br />HD DEAD
<br />H.M. HOWLLOW METAL
<br />HORIZ. HORIZONTAL
<br />HR. HOUR
<br />I. IRON
<br />I.D. INSIDE DIAMETER
<br />INC. INCORPORATED
<br />INSUL. INSULATION
<br />INT INTERIOR
<br />JT. JOINT
<br />JST. JOIST
<br />K. KITCHEN
<br />LAM. LAMINATED
<br />LAM. PLAS. LAMINATED PLASTIC
<br />LAV. LAVATORY
<br />LT. LIGHT
<br />LVR. LOUVER
<br />M.C. MEDICINE CABINET
<br />MECH. MECHANICAL
<br />MEMB. MEMBRANE
<br />MET. METAL
<br />MFG. MANUFACTURE
<br />M.H. MAN HOLE
<br />MIN. MINIMUM
<br />MIR. MIRROR
<br />MTG. MOUNTING
<br />MTL. METAL
<br />N. NORTH
<br />NAT. NATURAL
<br />N.I.C. NOT IN CONTRACT
<br />NO. NUMBER
<br />N.T.S. NOT TO SCALE
<br />O/ OVER
<br />O.C. ON CENTER
<br />O.D. OVERFLOW DRAIN
<br />OPP. OPPOSITE
<br />OV. OVEN
<br />OVHD. OVERHEAD
<br />PB. PUSHBUTTON
<br />PC PULL CHAIN
<br />PL PLATE
<br />P PROPERTY LINE
<br />PLAS. PLASTER
<br />PL. GLS. PLATE GLASS
<br />PLAST. PLASTER
<br />PLYWD. PLYWOOD
<br />PNL. PANEL
<br />PR. PAIR
<br />PRCST. PRECAST
<br />PREFAB. PREFABRICATED
<br />% [ERCEMT
<br />QRY. QUARRY
<br />QTY. QUANTITY
<br />RAD. RADIUS
<br />R. RISER
<br />R.A.G. RETURN AIR GRILLE
<br />RD. ROAD
<br />R.D. ROOF DRAIN
<br />RDWD. REDWOOD
<br />RECP. RECEPTABLE
<br />REF. REFERENCE
<br />REF. REFRIGERATOR
<br />REG. REGISTER
<br />REINF. REINFORCEMENT
<br />REQ'D REQUIRED
<br />RES. FLR. RESILIENT FLOORING
<br />RET. RETAINING
<br />RF. ROOF
<br />RF'G. ROOFING
<br />RM. ROOM
<br />RO. ROUGH
<br />R.O. ROUGH OPENING
<br />RUB. RUBBER
<br />R.B. RUBBER (RESILIENT) BASE
<br />S. SOUTH
<br />S.C. SOLID CORE
<br />S.D. STORM DRAIN
<br />SHT. SHEET
<br />SHT'G SHEATHING
<br />SIM. SIMILAR
<br />S&P SHELF AND POLE
<br />SPECS. SPECIFICATIONS
<br />SPRKL. SPRINKLER
<br />SQ. IN. SQUARE INCH
<br />SQ. FT. SQUARE FOOT
<br />ST. STEEL
<br />STOR. STORAGE
<br />STRUCT. STRUCTURAL
<br />SUSP. SUSPENDED
<br />SIM. SIMILAR
<br />S4S SMOOTH FOUR SIDES
<br />T TREAD
<br />T&B TOP AND BOTTOM
<br />T.B. TOP OF BEAM
<br />T.C. TOP OF CURB
<br />T.C. TOP OF CONCRETE
<br />T.G. TOP OF GRATE
<br />TEL TELEPHONE
<br />TEMP. TEMPERED
<br />T&G TONGUE AND GROOVE
<br />THK. THICK
<br />THRESH THRESHOLD
<br />T.P. TOP OF PAVING
<br />T.S. TOP OF SHEATHING
<br />T.W. TOP OF WALL
<br />TYP. TYPICAL
<br />UL UNDERWRITER'S LABEL
<br />ULT. ULTIMATE
<br />UNFIN. UNFINISHED
<br />U.R.F. UNDER ROOF FRAMING
<br />V.A.T. VINYL ASBESTOS TILE
<br />VENT. VENTILATOR
<br />VERT. VERTICAL
<br />VIT. VITREOUS
<br />VOL. VOLUME
<br />V.T. VINYL TILE
<br />W. WEST
<br />W/ WITH
<br />W.C. WATER CLOSET
<br />WD. WOOD
<br />W WIDE FLANGE (STEEL)
<br />W.G. WIRE GLASS
<br />W.H. WATER HEATER
<br />W.I. WROUGHT IRON
<br />W/O WITH OUT
<br />WP. WATERPROOFING
<br />WS WEATHERSTRIPPING
<br />W.S.P. WET STANDPIPE
<br />WT. WEIGHT
<br />YD. YARD
<br />ARCHITECTURAL SYMBOLS LEGENDGENERAL NOTES
<br />1. SITE DEVELOPMENT
<br />A. GRADE AND DEVELOP SITE SUCH THAT ALL PRIMARY BUILDING ENTRANCES ARE
<br />ACCESSIBLE TO THE PHYSICALLY DISABLED FROM THE PUBLIC WAY AND DISABLED PARKING
<br />PROVIDED.
<br />B. ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, FACILITIES AND SPACES
<br />ON THE SAME SITE. WHERE MORE THAN ONE ROUTE IS PROVIDED, ALL ROUTES SHALL BE
<br />ACCESSIBLE
<br />C. IF AN ACCESSIBLE ROUTE HAS A CHANGE IN LEVEL GREATER THAN 1/2", THEN A CURB RAMP,
<br />RAMP, ELEVATOR, OR PLATFORM LIFT SHALL BE PROVIDED.
<br />D. ALL WALKS, HALLS, CORRIDORS, AISLES, AND OTHER SPACES THAT ARE PART OF AN
<br />ACCESSIBLE ROUTE SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 48 INCHES AND A CLEAR
<br />HEIGHT OF 80 INCHES.
<br />2. WALKS AND SIDEWALKS
<br />A. WALKS AND SIDEWALKS SUBJECT TO THESE REGULATIONS SHALL HAVE A CONTINUOUS
<br />COMMON SURFACE, NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL
<br />EXCEEDING 1/2", AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH.
<br />B. ALL SIDEWALKS SHALL BE STABLE, FIRM AND SLIP RESISTANT.
<br />C. SURFACE CROSS SLOPES SHALL NOT EXCEED 1:48 (CBC 11B-403.3).
<br />D. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATINGS WHENEVER
<br />POSSIBLE. GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN
<br />THE GRATING SHALL BE LIMITED TO 1/2" IN THE DIRECTION OF TRAFFIC FLOW.
<br />E. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2".
<br />WHEN CHANGES DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2
<br />EXCEPT THAT LEVELS NOT EXCEEDING 1/4" MAY BE VERTICAL.
<br />F. WHEN CHANGES IN LEVELS GREATER THAN 1/2" ARE NECESSARY THEY SHALL COMPLY WITH
<br />THE REQUIREMENTS FOR CURB RAMPS OR RAMPS AS REQUIRED.
<br />G. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60" SQUARE AT A DOOR
<br />OR GATE THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48" WIDE BY 44" DEEP AT A
<br />DOOR OR GATE THAT SWINGS AWAY FROM THE WALK. SUCH WALKS SHALL EXTEND 24" TO THE
<br />SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK.
<br />H. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 5%, IT MUST
<br />COMPLY WITH THE PROVISIONS FOR PEDESTRIAN RAMPS (PER CBC 11B-405).
<br />I. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS AT LEAST 5 FEET IN
<br />LENGTH AT INTERVALS NOT EXCEEDING 400 FEET.
<br />3. ENTRANCES AND DOORWAYS
<br />A. PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO THE
<br />DISABLED.
<br />B. ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE "ISA" SIGN AND WITH
<br />ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED VISIBLE FROM APPROACHING PEDESTRIAN
<br />WAYS.
<br />C. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND ARE IN THE PATH OF
<br />TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC
<br />BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE
<br />WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.
<br />D. HAND ACTIVATED DOOR HARDWARE SHALL BE CENTERED BETWEEN 34" AND 44" ABOVE THE
<br />FLOOR (CBC 11B-404.2.7).
<br />E. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE
<br />LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL BE A MINIMUM 60" SQUARE IN THE
<br />DIRECTION OF THE DOOR SWING AND A MINIMUM 44" SQUARE OPPOSITE THE DIRECTION OF
<br />DOOR SWING (48" IF THE DOOR HAS BOTH LATCH AND CLOSER). THE SQUARES SHALL BE
<br />MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. SEE NOTE
<br />I BELOW FOR STRIKE SIDE REQUIREMENTS.
<br />F. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS
<br />SHALL EXTEND 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18" PAST
<br />THE STRIKE EDGE FOR INTERIOR DOORS AND THE PRIMARY ENTRANCE TO THE DWELLING
<br />UNIT.
<br />G THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF
<br />THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED NO GREATER
<br />THAN 1:2.
<br />H. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT SLIDING AND POCKET DOORS SHALL HAVE A
<br />SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR
<br />FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.
<br />I. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS FOR EXTERIOR DOORS
<br />AND 5 LBS FOR INTERIOR DOORS, SUCH PULL OR PUSH EFFORT SHALL BE APPLIED AT RIGHT
<br />ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS.
<br />COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE
<br />ABOVE STANDARDS. THE AUTHORITY HAVING JURISDICTION MAY INCREASE THE MAXIMUM
<br />EFFORT TO OPERATE FIRE DOORS TO ACHIEVE POSITIVE LATCHING, BUT NOT TO EXCEED 15
<br />LBS MAX.
<br />J. EXIT DOORS MUST OPEN FROM THE INSIDE WITHOUT A KEY, OR ANY SPECIAL KNOWLEDGE
<br />OR EFFORT. EXIT DOORS FROM BUILDINGS OR ROOMS SERVING 10 OR FEWER OCCUPANTS
<br />MAY HAVE A NIGHT LATCH, DEADBOLT OR SECURITY CHAIN, AS LONG AS THE DOORS CAN STILL
<br />BE OPENED FROM THE INSIDE WITHOUT A KEY, SPECIAL KNOWLEDGE OR EFFORT. IN ADDITION,
<br />THESE DEVICES ARE NOT MOUNTED MORE THAN 48" ABOVE THE FLOOR. MANUALLY OPERATED
<br />EDGE BOLTS, SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. WHEN
<br />EXIT DOORS ARE USED IN PAIRS AND AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF
<br />WITH THE FLUSH BOLT MUST HAVE NO DOORKNOB OR SURFACE MOUNTED HARDWARE. THE
<br />UNLATCHING OF ANY LEAF MUST NOT REQUIRE MORE THAN ONE OPERATION.
<br />K. EVERY REQUIRED EXIT MUST BE LARGE ENOUGH TO PERMIT A DOOR AT LEAST 3'-0" WIDE BY
<br />6'-8" HIGH. EXIT DOORS SHALL OPEN AT LEAST 90 DEGREES AND PROVIDE A CLEAR WIDTH OF
<br />AT LEAST 32".
<br />L. THRESHOLDS AT ALL EXTERIOR DOORS SHALL BE NO HIGHER THAN 1/2". SUCH THRESHOLDS
<br />SHALL BE BEVELED NO GREATER THAN 1:2.
<br />M. THE FLOOR LANDING IMMEDIATELY OUTSIDE THE ENTRY MAY BE SLOPED UP TO 1/8" PER
<br />FOOT IN THE DIRECTION AWAY FROM THE PRIMARY ENTRANCE FOR DRAINAGE.
<br />N. THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING
<br />OTHER THAN A REQUIRED EXIT STAIRWAY, MUST HAVE AT LEAST 48" OF CLEAR SPACE FROM
<br />ANY DOOR OPENING INTO THE VESTIBULE WHEN THE DOOR IS OPEN 90 DEGREES FROM ITS
<br />CLOSED POSITION. DOORS IN SERIES MUST SWING IN THE SAME DIRECTION OR AWAY FROM
<br />THE SPACE BETWEEN THE DOORS.
<br />4. STAIRWAYS
<br />A. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. STAIRWAYS SHALL HAVE
<br />INTERMEDIATE HANDRAILS WHERE REQUIRED SUCH THAT ALL PORTIONS OF THE STAIRWAY
<br />WIDTH REQUIRED FOR EGRESS CAPACITY ARE WITHIN 30 INCHES OF A HANDRAIL.
<br />INTERMEDIATE HANDRAILS SHALL BE SPACED AT EQUAL INTERVALS WITHIN THE WIDTH OF
<br />THE STAIRWAY AND BE CONTINUOUS FOR THE ENTIRE LENGTH.
<br />B. HANDRAILS MUST BE 34 TO 38 INCHES ABOVE THE NOSING OF THE TREADS AND MUST
<br />EXTEND IN THE DIRECTION OF THE STAIR RUN FOR AT LEAST 12" BEYOND THE TOP NOSING
<br />AND 12" PLUS THE TREAD WIDTH BEYOND THE BOTTOM NOSING.
<br />C. ENDS SHALL BE RETURNED OR SHALL TERMINATE IN A NEWEL POST OR SAFETY
<br />TERMINAL.
<br />D. HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2-
<br />INCH BETWEEN THE WALL AND THE HANDRAIL.
<br />E. THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4-INCHES NOR
<br />MORE THAN 1 1/2-INCHES IN CROSS-SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE
<br />AN EQUIVALENT GRIPPING SURFACE AND SHALL HAVE A SMOOTH SURFACE WITH NO SHARP
<br />OR ABRASIVE CORNERS AND ALL EDGES MUST HAVE A MINIMUM 1/8" RADIUS.
<br />F. THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR SHALL BE
<br />MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR THE FULL WIDTH OF THE TREAD AT
<br />LEAST 2-INCHES WIDE PLACED PARALLEL TOAND NOT MORE THAN 1-INCH FROM THE NOSE OF
<br />THE STEP OR LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A
<br />MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR.
<br />G. WHERE STAIRWAYS OCCUR OUTSIDE A BUILDING, THE UPPER APPROACH AND ALL
<br />TREADS SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2-
<br />INCHES WIDE AND PLACED PARALLEL TO AND NOT MORE THAN 1-INCH FROM THE NOSE OF
<br />THE STEP OR LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A
<br />MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A
<br />PAINTED STRIP SHALL BE ACCEPTABLE.
<br />H. ALL TREAD SURFACES SHALL BE SLIP RESISTANT.
<br />I. TREADS SHALL HAVE A SMOOTH, ROUNDED OR CHAMFERED EXPOSED EDGES, AND NO
<br />ABRUPT EDGES AT THE NOSING (LOWER FRONT EDGE).
<br />J. NOSING SHALL NOT PROJECT MORE THAN 1-1/4 INCH PAST THE FACE OF THE RISER
<br />BELOW.
<br />K. STAIR RISERS SHALL BE SOLID PER CBC 11B-504.
<br />5. SANITARY FACILITIES
<br />A. WHEELCHAIR ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A
<br />DOOR THAT HAS AN AUTOMATIC CLOSING DEVICE, AND SHALL HAVE A CLEAR
<br />UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WHEN LOCATED AT THE END AND 34-INCHES
<br />WHEN LOCATED AT THE SIDE WITH THE DOOR POSITION AT AN ANGLE OF 90 DEGREES FROM
<br />ITS CLOSED POSITION.
<br />B. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE
<br />TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR FLUSH VALVES
<br />SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44-INCHES
<br />ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER
<br />THAN 5 POUNDS PER FOOT.
<br />C. WHERE URINALS ARE PROVIDED AT LEAST ONE WITH A RIM PROJECTING A MINIMUM OF 14-
<br />INCHES FROM THE WALL AND AT A MAXIMUM OF 17-INCHES ABOVE THE FLOOR SHALL BE
<br />PROVIDED.
<br />D. URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT
<br />REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST AND SHALL BE MOUNTED
<br />NO MORE THAN 44" ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS
<br />SHALL BE NO GREATER THAN 5 POUNDS PER FOOT.
<br />E. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE
<br />COVERED.
<br />F. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND
<br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE
<br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER
<br />FOOT. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE
<br />EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET
<br />REMAINS OPEN FOR AT LEAST 10 SECONDS.
<br />G. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM GLASS EDGE NOT MORE THAN 40-
<br />INCHES ABOVE THE FLOOR.
<br />H. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL OPERABLE
<br />PARTS NOT MORE THAN 40-INCHES FROM THE FLOOR.
<br />I. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL OR PARTITION WITHIN 7" TO
<br />9" TO CENTERLINE FROM THE FRONT EDGE OF THE TOILET SEAT, MOUTED BELOW THE GRAB
<br />BAR, AT A MINIMUM HEIGHT OF 19 INCHES, AND 36 INCHES MAXIMUM TO THE FAR EDGE FROM
<br />THE REAR WALL. DISPENSERS SHALL PERMIT CONTINUOUS FLOW AND NOT CONTROL
<br />DELIVERY (CBC 11B-604.7).
<br />J. GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVICES SHALL BE
<br />DESIGNED FOR 250 LB. PER CBC 1607A.8.2.
<br />K. GRAB BARS:
<br />1. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACE OF A GRAB BAR SHALL BE
<br />1-1/4" TO 1-1/2" OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE.
<br />2. IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN
<br />THE WALL AND THE GRAB BARS SHALL BE 1-1/2".
<br />3. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT SHALL BE FREE OF
<br />ANY SHARP OR ABRASIVE ELEMENTS.
<br />4. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
<br />5. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8".
<br />6. SWITCHES CONTROLS AND ELECTRICAL OUTLETS
<br />A. RECEPTACLE OUTLETS SHALL BE 15" MIN ABOVE THE FINISHED FLOOR TO THE BOTTOM OF
<br />THE BOX PER CBC 11B-308.1.2.
<br />B. SWITCHES SHALL BE 48" MAX. ABOVE THE FINISHED FLOOR TO THE TOP OF THE BOX
<br />(11B-308.1.1).
<br />C. IF REACH IS OVER AN OBSTRUCTION ( FOR EXAMPLE, A BASE CABINET ) BETWEEN 20" AND
<br />25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH, OR 46"
<br />FOR SIDE APPROACH PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. THE
<br />OBSTRUCTION MAY NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH THE CONTROL.
<br />D. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" ABOVE
<br />THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK.
<br />E. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED THEY SHALL ACTIVATE A MEANS OF
<br />WARNINGTHE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY
<br />OF NOT MORE THAN 60 FLASHES PER MINUTE.
<br />1. THESE DOCUMENTS AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN
<br />INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SVA ARCHITECTS,
<br />AND ARE NOT TO BE USED, IN WHOLE OR IN PART FOR ANOTHER PROJECT WITHOUT
<br />THE WRITTEN AUTHORIZATION OF SVA ARCHITECTS.
<br />2. THE WORK SHOWN ON THESE DRAWINGS AS EXISTING CONDITIONS WAS
<br />PREPARED FROM INFORMATION FURNISHED BY THE OWNER. WHILE THIS
<br />INFORMATION IS BELIEVED TO BE RELIABLE, SVA ARCHITECTS INC. IS NOT
<br />RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OF ANY WORK SHOWN AS EXISTING
<br />NOR IS SVA ARCHITECTS INC. RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
<br />MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT.
<br />3. EACH BIDDER SHALL POSSESS AT THE TIME OF BID A CLASS B OR THE
<br />APPROPRIATE CLASS C CONTRACTOR'S LICENSE PURSUANT TO PUBLIC CONTRACT
<br />CODE SECTION 3300 AND BUSINESS AND PROFESSIONS CODE SECTION 7028.15. THE
<br />SUCCESSFUL BIDDER MUST MAINTAIN THE LICENSE THROUGHOUT THE DURATION OF
<br />THIS CONTRACT.
<br />4. FIRE SAFETY DURING CONSTRUCTION AND THE DURATION OF THIS CONTRACT:
<br />A. GENERAL: FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH 2022
<br />CALIFORNIA FIRE CODE TITLE 24, PART 9, CHAPTER 33.
<br />B. ACCESS ROADS: FIRE DEPARTMENT ACCESS ROADS SHALL BE ESTABLISHED AND
<br />MAINTAINED IN ACCORDANCE WITH SECTION C.F.C SECTION 3311.
<br />C. WATER SUPPLY: WATER MAINS AND HYDRANTS SHALL BE OPERATIONAL IN
<br />ACCORDANCE WITH C.F.C SECTION 3311.
<br />D. BUILDING ACCESS: ACCESS TO BUILDINGS FOR THE PURPOSE OF FIREFIGHTING
<br />SHALL BE PROVIDED. CONSTRUCTION MATERIAL SHALL NOT BLOCK ACCESS TO
<br />BUILDINGS, HYDRANTS OR FIRE APPLIANCES.
<br />E. ALTERATIONS OF BUILDINGS: SHALL COMPLY WITH APPLICABLE PROVISIONS OF
<br />SECTIONS 1405, 1411, 1413, AND 1415.
<br />G. FIRE WATCH: MAINTAIN FIRE WATCH WHEN REQUIRED BY THE BUILDING OFFICIAL
<br />AND WHEN EXISTING FIRE PROTECTION SYSTEMS ARE SHUT DOWN FOR ALTERATIONS.
<br />FIRE WATCH SHALL REMAIN IN EFFECT UNTIL EXISTING FIRE PROTECTION SYSTEMS
<br />ARE RETURNED TO SERVICE OR AS ALLOWED BY THE BUILDING OFFICIAL.
<br />5. NOT USED
<br />6. STATEMENT (TITLE 24, PART 6): NONRESIDENTIAL ENERGY STANDARDS
<br />COMPLIANCE: THE DESIGN INDICATED HEREIN COMPLIES WITH THE REQUIREMENTS OF
<br />THE ENERGY CONSERVATION STANDARDS OF TITLE 24, PART 6, CALIFORNIA CODE OF
<br />REGULATIONS. THE PROPOSED BUILDING WILL BE IN COMPLIANCE WITH THE ENERGY
<br />CONSERVATION STANDARDS PROVIDED IT IS BUILT ACCORDING TO THESE DRAWINGS
<br />AND SPECIFICATIONS AND PROVIDED ANY FUTURE IMPROVEMENTS ARE COMPLETED
<br />ACCORDING TO THE REQUIREMENTS OF TITLE 24, PART 6, CALIFORNIA CODE OF
<br />REGULATIONS. THESE PLANS AND SPECIFICATIONS HAVE BEEN PREPARED TO INCLUDE
<br />ALL SIGNIFICANT ENERGY CONSERVATION FEATURES REQUIRED FOR COMPLIANCE
<br />WITH THE STANDARDS. BUILDING AREAS THAT ARE UNCONDITIONED AND/OR NOT
<br />SUBJECT TO THE STANDARDS ARE INDICATED ON THE PLANS.
<br />ENVELOPE MANDATORY MEASURES:
<br />A. INSTALLED INSULATING MATERIALS SHALL HAVE BEEN CERTIFIED BY THE
<br />MANUFACTURER TO COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR
<br />INSULATING MATERIAL.
<br />B. ALL INSULATING MATERIALS SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME
<br />SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF [TITLE 24, PART 2,
<br />CALIFORNIA BUILDING CODE, SECTIONS 720 AND 803.]
<br />C. ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE THAT ARE
<br />POTENTIAL AND OBSERVABLE SOURCES OF AIR LEAKAGE SHALL BE CAULKED,
<br />GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED.
<br />D. SITE CONSTRUCTED DOORS, AND WINDOWS SHALL BE CAULKED BETWEEN THE UNIT
<br />AND THE BUILDING, AND SHALL BE WEATHERSTRIPPED (EXCEPT FOR UNFRAMED
<br />GLASS DOORS AND FIRE DOORS).
<br />E. MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION
<br />RATES CERTIFIED BY THE MANUFACTURER IN ACCORDANCE WITH TITLE 24, PART 6,
<br />CALIFORNIA CODE OF REGULATIONS, SECTION 116(a)1.
<br />F. MANUFACTURED FENESTRATION PRODUCTS IN THE ENVELOPE OF THE BUILDING,
<br />INCLUDING, BUT NOT LIMITED TO, WINDOWS, SLIDING GLASS DOORS, FRENCH DOORS,
<br />SKYLIGHTS, CURTAIN WALLS, AND GARDEN WINDOWS MUST BE LABELED FOR U-VALUE
<br />IN ACCORDANCE WITH THE (NFRC) NATIONAL FENESTRATION RATING COUNCIL'S
<br />INTERIM U-VALUE RATING PROCEDURE.
<br />G. NOT USED.
<br />7. INSPECTOR OF RECORD REQUIREMENTS: A. ONE OR MORE INSPECTORS
<br />EMPLOYED BY THE OWNER IN ACCORDANCE WITH THE REQUIREMENTS OF TITLE 24
<br />PART 1 OF THE CALIFORNIA CODE OF REGULATIONS WILL BE ASSIGNED TO THE WORK.
<br />THE INSPECTORS DUTIES ARE SPECIFICALLY DEFINED IN SECTION 4-342 OF SAID TITLE
<br />24, PART 1 AND IN ADDITION SHALL BE AS STIPULATED IN INTERPRETATION OF
<br />REGULATION DOCUMENT IR A-8. B. INSPECTOR SHALL BE CERTIFIED AS A CLASS [2]
<br />INSPECTOR. INSPECTOR SHALL ALSO BE SPECIFICALLY APPROVED BY THE BUILDING
<br />DEPARTMENT FOR THIS PROJECT AT LEAST 10 DAYS PRIOR TO THE START OF ANY
<br />WORK FOR THIS PROJECT.
<br />8. ALL WORK SHOWN ON THESE DRAWINGS SHALL COMPLY WITH THE REQUIREMENTS
<br />OF TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR).
<br />9. CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY
<br />AN ADDENDUM OR A CCD APPROVED BY THE BUILDING DEPARTMENT.
<br />10. GRADING PLANS, DRAINAGE IMPRPOVEMENTS, ROAD AND ACCESS REQUIREMENTS
<br />AND ENVIROMENTAL HEALTH CONCIDERATIONS SHALL COMPLY WITH ALL LOCAL
<br />ORDINANCES.
<br />11. DRINKING WATER SHALL COMPLY WITH ALL LOCAL HEALTH DEPARTMENT
<br />REQUIREMENTS.
<br />12. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE
<br />APPLICABLE CODES. ALL ENGINEERING SHALL COMFORM WITH ALL APPLICABLE
<br />MUNICIPAL, STATE AND FEDERAL REGULATIONS HAVING JURISDICTION INCLUDING
<br />ACCESSIBILITY STANDARDS AND ADA REQUIREMENTS.
<br />13. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE.
<br />THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD
<br />PRIOR TO BIDDING AND START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE
<br />ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING WORK.
<br />14. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF MASONRY UNITS,
<br />CENTERLINE OF COLUMNS AND BEAMS, OR FACE OF STUDS, UNLESS OTHERWIS
<br />NOTED. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB OR TOP OF
<br />INTERIOR PAVING UNLESS NOTED OTHERWISE. CEILING HEIGHT DIMENSIONS ARE TO
<br />FINISHED SURFACES UNLESS NOTED OTHERWISE.
<br />15. THE CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS
<br />ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE
<br />RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL
<br />DRAWINGS BEFORE PROCEEDING WITH INSTALLATION OF CIVIL, STRUCTURAL
<br />MECHANICAL, PLUMBING, AND ELECTRICAL WORK. SHOULD THERE BE ANY
<br />DISCREPANCIES BETWEEN THE ARCHITECT'S AND THE CONSULTING ENGINEER'S
<br />DRAWINGS AND SPECIFICATIONS THAT WOULD CAUSE A CONFLICT, IT SHALL BE
<br />BROUGHT TO THE ARCHITECTS ATTENTION FOR CLARIFICATION PRIOR TO
<br />INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE
<br />ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS
<br />EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT.
<br />16. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO
<br />BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING
<br />ABBREVIATIONS OR THEIR EXACT MEANING, THE ARCHITECT SHALL BE NOTIFIED FOR
<br />CLARIFICATION.
<br />17. DETAILS AND NOTES MARKED "TYPICAL" SHALL APPLY IN ALL SIMILAR CASES
<br />UNLES SPECIFICALLY INDICATED OTHERWISE.
<br />18. THE BID DOCUMENTS ARE COMPRISED OF THE DRAWINGS, PROJECT MANUAL
<br />GENERAL CONDITIONS, GENERAL REQUIREMENTS AND TECHNICAL SPECIFICATIONS
<br />AND ALL SUPPLEMENTAL DOUCMENTS (BID ADDENDA, ETC.). THE GENERAL
<br />CONTRACTOR IS EXPECTED TO READ ALL DOCUMENTS AND BECOME FAMILIAR WITH
<br />THE CONTENT CONTAINED WITHIN THESE DOCUMENTS. IF DISCREPANCIES OCCUR
<br />BETWEEN DIFFERENT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER AND
<br />THE ARCHITECT TO REQUEST CLARIFICATION. SVA ARCHITECTS, INC. AND THEIR
<br />ENGINEERS ARE THE AUTHORS OF THESE DOCUMENTS AND WILL PROVIDE
<br />CLARIFICATIOIN WHERE NECESSARY.
<br />19. THESE DOCUMENTS WERE PREPARED BASED ON AS-BUILT DOCUMENTS PROVIDED
<br />BY THE OWNER AND SITE OBSERVATIONS MADE BY THE DESIGN TEAM. THE
<br />CONTRACTOR SHALL FIELD VERIFY ALL FIELD CONDTIONS PRIOR TO PREPARING SHOW
<br />DRAWINGS FOR REVIEW.
<br />20. 2X WOOD BLOCKING AND/OR METAL STUD BLOCKING SHALL BE PROVIDED IN ALL
<br />WALLS WHERE EQUIPMENT, ACCESSORIES AND/OR CABINETS ARE SHOWN TO BE
<br />MOUNTED TO THE WALLS. ALL AFFECTED AREAS REQURIED TO BE OPENED UP TO
<br />INSTALL SUCH BLOCKING SHALL BE PATCHED AND REPAIRED TO MATCH ADJOINING
<br />SURFACE TEXTURE AND FINISHES
<br />21. WHERE DOMOLITION IS SHOWN OR DESCRIBED IN NOTES ON THE DRAWINGS, SUCH
<br />ITEMS SHALL INCLUDE ALL SYSTEMS WITHIN THE DEMOLISHED ITEM. FOR INSTANCE,
<br />WALL DEMOLITION SHALL INCLUDE THE CURB, FINISHES ON EACH SIDE AND
<br />ELECTRICAL AND/OR PLUMBING COMPONENTS WITHIN. PLUMBING AND/OR ELECTRICAL
<br />SYSTEMS WITHIN DEMOLISHED COMPONENTS SHALL BE COORDINATED WITH
<br />RESPECTIVE DRAWINGS FOR RE-ROUTING OR CAPPING SYSTEMS.
<br />18. ALL RUBBISH AND DEBRIS RESULTING FROM DEMOLITION AND/OR NEW WORK SHALL BE
<br />DISPOSED OF OFF-SITE DAILY AND SHALL NOT BE ALLOWED TO ACCUMULATE.
<br />19. SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH SECTION 01 30 00 OF SPECIFICATIONS AND AS
<br />REQUIRED BY INDIVIDUAL SPECIFICATION SECTIONS.
<br />20. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL PRIOR TO BID.
<br />REQUEST FOR SUBSTITUTION SHALL BE IN ACCORDANCE WITH SECTION 01 60 00 OF SPECIFICATIONS.
<br />21. NOT USED
<br />22. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE FLUSH.
<br />23. NOT USED
<br />24. NOT USED
<br />25. INSTALL METAL CORNER BEADS AT ALL EXPOSED GYPSUM BOARD EDGES INSTALL CASING BEADS
<br />WHEREVER GYPSUM BOARD, PLASTER, ETC. ABUTS DISSIMILAR FINISH MATERIAL AND PROVIDE
<br />SEALANT AS REQUIRED.
<br />26. GYPSUM BOARD SHALL EXTEND TO UNDERSIDE OF STRUCTURE ABOVE AT ALL COLUMNS AND
<br />EXTERIOR PERIMETER WALLS UNLESS OTHERWISE NOTED.
<br />27. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES, AND
<br />SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, STAIR RAILINGS,
<br />TOILET ROOM ACCESSORIES AND PARTITIONS, AND OF ALL WALL MOUNTED OR SUSPENDED
<br />MECHANICAL, ELECTRICAL, OR MISCELLANEOUS EQUIPMENT.
<br />28. ALL GLAZING SHALL COMPLY WITH THE CONSUMER PRODUCT SAFETY COMMISSION
<br />REQUIREMENTS (C.P.S.C.), CFC, AND CBC.
<br />29. CONTACT BETWEEN DISSIMILAR METAL SHALL BE PROTECTED AGAINST GALVANIC CORROSION.
<br />30. ALL DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR
<br />THRESHOLDS, ETC. SHALL BE TAKEN OFF DOOR. ALL DOORS AND FRAME SHALL BE REINFORCED
<br />WHERE REQUIRED FOR CLOSERS, STOPS, AND HARDWARE.
<br />31. ROOFING SYSTEM SHALL BEAR U.L. LISTING AS A CLASS "A" SYSTEM. ALL MANUFACTURED
<br />MATERIALS USED SHALL BEAR THE APPROPRIATE U.L. LABEL.
<br />32. ALL WOOD TRIM, SPACER, FILLER, ETC., THROUGHOUT JOB SHOULD BE FIRE TREATED.
<br />33. INSPECTION AND TESTING LABORATORY MUST BE IN THE EMPLOY OF THE OWNER, NOT THE
<br />CONTRACTOR.
<br />34. NOT USED
<br />35. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY
<br />SPECIAL KNOWLEGE. LOCKING DEVICES SHALL BE OF AN APPROVED TYPE.
<br />36. EXIT SIGNS SHALL HAVE 6" MINIMUM HEIGHT LETTERS AND SHALL CONFORM TO SECTION 1013 OF
<br />THE CALIFORNIA BUILDING CODE.
<br />37. FURNISH AND INSTALL ACCESS DOORS, FIRE DAMPERS, ETC. IN CEILING AND WALL
<br />CONSTRUCTION LOCATED AS REQUIRED BY INSTALLATION OF MECHANICAL PLUMBING, AND
<br />ELECTRICAL WORK AND AS APPROVED BY THE ARCHITECT. PROVIDE RATED ASSEMBLIES IN RATED
<br />WALLS AND CEILINGS AND SHALL BE APPROVED BY BUILDING INSPECTOR PRIOR TO INSTALLATION.
<br />38. FURNISH AND INSTALL EMERGENCY LIGHTING AS SPECIFIED AND INDICATED BUT IN NO CASE
<br />SHALL THE LIGHT VALUE BE LESS THAN ONE FOOT CANDLE AT FLOOR LEVEL IN ALL EXIT CORRIDORS
<br />AND STAIR SHAFTS (CBC SECTION 1008).
<br />39. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH INTO WHICH A PERSON IS
<br />REQUIRED TO DECEND UNLESS A PERMIT IS OBTAINED FROM THE STATE OF CALIFORNIA DIVISION OF
<br />INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING PERMIT.
<br />40. NOT USED.
<br />41. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 18" OF THE ADJACENT
<br />FLOOR SHALL BE GLASS APPROVED FOR IMPACT HAZARD.
<br />42. ALL LIGHT GAUGE METAL STUDS AND BRACING SHALL COMPLY WITH 2016 CALIFORNIA BUILDING
<br />CODE.
<br />43. IF OCCURS, INSTALLATION OF SHORING, UNDERPINNING, AND/OR SLOT CUTTING EXCAVATIONS
<br />SHALL BE PERFORMED UNDER THE CONTINUOUS INSPECTION AND APPROVAL OF THE GEOTECHNICAL
<br />ENGINEER.
<br />44. ALL CONSTRUCTION SHALL PERFORMED IN ACCORDANCE WITH THE STATE CONSTRUCTION
<br />SAFETY ORDERS ENFORCED BY THE STATE DIVISION OF INDUSTRIAL SAFETY.
<br />45. DIMENSIONS AND CONDITIONS AT THE JOB SITE SHALL BE VERIFIED BY ALL CONTRACTORS. IT IS
<br />THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE EXISTING CONDITIONS PRIOR TO
<br />SUBMITTING BIDS TO THE OWNER SINCE PROPOSALS MUST TAKE INTO CONSIDERATION ALL SUCH
<br />CONDITIONS THAT MAY AFFECT THE WORK. DISCREPANCIES IN THE DRAWINGS OR BETWEEN THE
<br />DRAWINGS AND ACTUAL FIELD CONDITION SHALL BE REPORTED TO THE ARCHITECT. REVISED
<br />DRAWINGS OR INSTRUCTIONS SHALL BE ISSUED BY THE OWNER PRIOR TO THE INSTALLATION OF ANY
<br />WORK.
<br />46. CONTRACTORS SHALL PROVIDE AND INSTALL ALL CONCRETE HOUSEKEEPING PADS FOR
<br />MECHANICAL AND ELECTRICAL EQUIPMENT, AS REQUIRED.
<br />47. ALL GYPSUM WALL BOARD TO BE 5/8" THICK TYPE 'X' UNLESS OTHERWISE NOTED OR REQUIRED
<br />FOR SPECIFIC WALL CONSTRUCTION.
<br />48. THERMAL INSULATION SHALL BE PROVIDED PER TYPICAL ASSEMBLIES NOTED ON DRAWINGS.
<br />REFER TO SPECS FOR PRODUCT INFORMATION.
<br />49. PROVIDE SAFETY GLASS AT LOCATIONS REQUIRED BY CBC SECTION 2406 AND BY OTHER
<br />APPLICABLE CODE.
<br />50. ROOF DRAINS DISCHARGING WATER MUST BE CONDUCTED UNDER THE SIDEWALK
<br />51. DOORS SHALL NOT PROJECT MORE THAN 7 INCHES INTO THE REQUIRED CORRIDOR WIDTH WHEN
<br />FULLY OPENED OR MORE THAN ONE HALF INTO THE REQUIRED WIDTH WHEN IN ANY POSITION. (CBC
<br />SECTION 1005.7.1)
<br />52. PUBLIC HALLWAYS AND EXIT COURT PASSAGEWAYS TO HAVE 7'-0" CLEAR HEIGHT TO LOWEST
<br />PROJECTION. (CBC SECTION 1005.3)
<br />53. OCCUPANCY LOAD SIGNS SHALL BE POSTED IN EACH CLASSROOM, ASSEMBLY ROOM, OR SIMILAR
<br />PURPOSE ROOM, HAVING AN OCCUPANT LOAD OF 50 OR MORE.
<br />54. NOT USED
<br />55. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF
<br />THE ARCHITECT/ENGINEER WHOSE SIGNATURE APPEARS HEREON.
<br />56. THESE DRAWINGS DO NOT CONTAIN THE NECESSARY COMPONENTS FOR CONSTRUCTION
<br />SAFETY.
<br />57. LOCATIONS OF ALL UTILITIES SHOWN ARE APPROXIMATE AND CONTRACTOR SHALL EXERCISE
<br />EXTREME CAUTION IN EXCAVATING AND TRENCHING ON THIS SITE TO AVOID INTERCEPTING EXISTING
<br />PIPING OR CONDUITS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL
<br />EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE
<br />ARCHITECT IS NOT RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES
<br />WHETHER OR NOT SHOWN OR DETAILED AND INSTALLED BY ANY OTHER CONTRACT. THE
<br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT SHOULD ANY UNIDENTIFIED CONDITIONS
<br />BE DISCOVERED. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF
<br />UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE
<br />PROSECUTION OF THIS WORK.
<br />58. THE PROJECT APPLICANT SHALL COMPLY WITH THE REQUIREMENTS OF THE ENGINEERING
<br />DIVISION FOR ALL PUBLIC IMPROVEMENTS.
<br />ACCESSIBILITY NOTES
<br />DESCRIPTION DATE
<br />1 ASI #01 04/09/25
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
|