Laserfiche WebLink
B. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE <br />TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR FLUSH VALVES <br />SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44" INCHES <br />ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER <br />THAN 5 POUNDS PER FOOT. <br />C. WHERE URINALS ARE PROVIDED AT LEAST ONE WITH A RIM PROJECTING A MINIMUM OF 14 <br />INCHES FROM THE WALL AND AT A MAXIMUM OF 17 INCHES ABOVE THE FLOOR SHALL BE <br />PROVIDED. <br />D. URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT <br />REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST AND SHALL BE MOUNTED <br />NO MORE THAN 44" ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVE CONTROLS SHALL <br />BE NO GREATER THAN 5 POUNDS PER FOOT. <br />E. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE <br />COVERED. <br />F. FAUCET CONTROLS AND OPEARTING MECHANISMS SHALL BE OPERABLE WITH ONE HAND <br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE <br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER <br />FOOT. LEVEL OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE <br />EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET <br />REMAINS OPEN FOR AT LEAST 10 SECONDS. <br />G. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH <br />THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH <br />FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL <br />BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAXIMUM <br />ABOVE THE FINISH FLOOR OR GROUND. <br />7. ACCESSIBLE TOILET COMPARTMENTS: <br />A. SEE TOILET ROOM FLOOR PLAN FOR ACCESSIBLE TOILET STALL LOCATION. <br />B.VERIFY TOILET ACCESSORIES & TYPE OF PARTITION IN SPECS. <br />C. PROVIDE BACKING IN WALL & TOILET PARTITION FOR GRAB BAR ANCHORAGE. <br />D. COMPARTMENT DOOR TO PROVIDE MINIMUM 18" STRIKE-SIDE CLEARANCE (CBC <br />11B604.8.1). <br />E. DOOR PULL AT ACCESSIBLE COMPARTMENT SHALL COMPLY WITH CBC SECTION <br />11B-404.2.7 AND NOT REQUIRE GRASPING OR TWISTING. <br />F. OPENING HARDWARE IS CENTERED BETWEEN 34" AND 44" ABOVE FINISH FLOOR (CBC <br />11B-404.2.7). <br />G. TOILET PAPER DISPENSER SHALL PERMIT CONTINUOUS PAPER FLOW AND SHALL NOT <br />CONTROL DELIVERY (CBC 11B-604.9.6). <br />H. ACCESSIBLE COMPARTMENT DOOR EQUIPPED WITH AN AUTOMATIC CLOSING DEVICES (5 <br />SECONDS MIN. SWEEP TIME FROM OPEN POSITION OF 90 DEGREES TO A POINT 12 DEGREES <br />FROM THE LATCH). <br />I. SEE ACCESSIBILITY NOTES FOR ADDITIONAL REQUIREMENTS. <br />J. FLUSH CONTROL SHALL BE ON WIDE SIDE OF TOILET COMPARTMENT AT ALL ACCESSIBLE <br />STALLS, TYP. <br />K. WHERE ONLY ONE TYPE OF TOILET FIXTURE OR ACCESSORY IS USED, IT SHALL BE <br />POSITIONED FOR ACCESSIBILITY. <br />H. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL OPERABLE <br />PARTS NOT MORE THAN 40 INCHES FROM THE FLOOR. <br />I. LOCATE TOILET TISSUE DISPENSERS ON THE WALL OR PARTITION WITHIN 7 INCHES <br />MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE <br />CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE <br />GRAB BAR, 19 INCHES MINIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED <br />BEHIND GRAB BARS (CBC 11B- 604.7) <br />J. GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVICES SHALL BE <br />DESIGNED FOR 250 LB. PER LINEAR FOOT LOAD. <br />K. GRAB BARS (REFER DETAIL ): <br />1) THE DIAMETER OR WIDTH OF THE GRIPPING SURFACE OF A GRAB BAR SHALL BE <br />1-1/4" TO 1-1/2" OR THE SHAPE SHALL PROVIDE EQUIVALENT GRIPPING SURFACE. <br />2) IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN <br />THE WALL AND GRAB BARS SHAL LBE 1-1/2". <br />3) A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT SHALL BE FREE OF <br />ANY SHARP OR ABRASIVE ELEMENTS. <br />4) GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br />5) EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". <br />L. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. <br />1. ENTRANCES AND DOORWAYS: (REFER TO DETAIL ) <br />A. PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO THE <br />DISABLED. <br />B. RECESSED DOOR MATS SHALL BE ANCHORED TO PREVENT INTERFERENCE WITH WHEELCHAIRS. <br />C. ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE SIGN (INTERNATION SYMBOL <br />OF ACCESSIBILITY) AND WITH ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED VISIBLE FROM <br />APPROACHING PEDESTRIAN WAYS. <br />D. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND <br />CLEAR. THE LEVEL AND CLEAR AREA SHALL BE A MINIMUM 60" SQUARE IN THE DIRECTION OF THE <br />DOOR SWING AND A MINIMUM 44" SQUARE OPPOSITE THE DIRECTION OF DOOR SWING. THE SQUARES <br />SHALL BE MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. SEE <br />NOTE E BELOW FOR STRIKE SIDE CLEARANCES. <br />E. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL <br />EXTEND 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18" PAST THE STRIKE <br />EDGE FOR INTERIOR DOORS. <br />F. THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE <br />DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED NO GREATER THAN 1:2. <br />G. THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING OTHER THAN <br />A REQUIRED EXIT STAIRWAY, MUST HAVE AT LEAST 48" OF CLEAR SPACE FROM ANY DOOR OPENING <br />INTO THE VESTIBULE WHEN THE DOOR IS OPEN 90 DEGREES FROM ITS CLOSED POSITION. DOOR IN <br />SERIES MUST SWING IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS. <br />H. WHERE A PAIR OF DOORS, MANUALLY OR AUTOMATICALLY OPERATED, IS UTILIZED, AT LEAST ONE <br />OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING 32" WIDE W/ THE LEAF <br />POSITIONED 90 DEGREES FROM ITS CLOSED POSITION. <br />I. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTMOATIC AND SLIDING SHALL HAVE A SMOOTH, <br />UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO OPEN BY A WHEELCHAIR FOOTREST WITHOUT <br />CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED A 10" <br />HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE <br />DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATED A TRAP OR HAZARDOUS <br />CONDITION. <br />J. MAXIMUM EFFORT TO OPERATED DOORS SHALL NOT EXCEED 5 LB. SUCH PULL OR PUSH EFFORT <br />SHALL BE APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR <br />FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO <br />MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO <br />OPERATE THE DOOR MAY BE INCREASED TO THE MAXIMUM ALLOWABLE BY THE APPROPRIATE <br />ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. <br />2. DRINKING FOUNTAINS: (REFER TO DETAIL ) <br />A. ON ANY FLOOR WHERE DRINKING FOUNTAINS ARE PROVIDED, THERE SHALL BE A DRINKING <br />FOUNTAIN THAT IS ACCESSIBLE TO INDIVIDUALS WHO USE WHEELCHAIRS AND ONE ACCESSIBLE TO <br />THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING ("HI-LO" FOUNTAIN) PER CBC 11B-211.2) WHERE <br />MORE THAN ONE IS PROVIDED ON A FLOOR, 50% SHALL COMPLY WITH THESE REQUIREMENTS.(CBC <br />11B-211.3) <br />B. THE DRINKING FOUNTAIN SHALL BE A MINIMUM OF 18 INCHES AND A MAXIMUM OF 19 INCHES IN <br />DEPTH AND THERE SHALL BE A CLEAR AND UNOBSTRUCTED KNEE SPACE UNDER THE DRINKING <br />FOUNTAIN NOT LESS THAN 27 INCHES IN HEIGHT, 30 INCHES IN WIDTH, AND 8 INCHES IN DEPTH, THE <br />DEPTH MEASUREMENT BEING TAKEN FROM THE FRONT EDGE OF THE FOUNTAIN. ADDITIONALLY <br />THERE SHALL BE TOE CLEARANCE OF 9 INCHES IN HEIGHT ABOVE THE FLOOR, AND 17 INCHES IN <br />DEPTH FROM THE FRONT EDGE OF THE FOUNTAIN. A SIDE APPROACH DRINKING FOUNTAIN IS NOT <br />ACCEPTABLE. <br />C. THE BUBBLER SHALL BE ACTIVATED BY A CONTROL WHICH IS EASILY OPERATED BY A DISABLED <br />PERSON SUCH AS A HAND-OEPRATED LEVER TYPE LOCATED WITHIN 5 INCHES OF THE FRONT OF THE <br />DRINKING FOUNTAIN. THE BUBBLER OUTLET ORIFICE SHALL BE LOCATED WITHIN 6 INCHES OF THE <br />FRONT OF THE DRINKING FOUNTAIN AND SHALL BE WITHIN 36 INCHES OF THE FLOOR. THE WATER <br />STREAM FROM THE BUBBLER SHALL BE SUBSTANTIALLY PARALLEL TO THE FRONT EDGE OF THE <br />DRINKING FOUNTAIN. THE SPOUT SHALL PROVIDE A FLOW OF WATER THAT IS AT LEAST 4 INCHES <br />HIGH SO AS TO ALLOW THE INSERTION OF A CUP OR GLASS UNDER THE FLOW OF WATER. THE FORCE <br />REQUIRED TO ACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LB. <br />D. WATER FLOW. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES (102 MM) HIGH MINIMUM <br />AND SHALL BE LOCATED 5 INCHES (127 MM) MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF <br />THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE <br />UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3 INCHES (76 MM) OF THE FRONT OF THE UNIT, THE <br />ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED <br />BETWEEN 3 INCHES (76 MM) AND 5 INCHES (127 MM) MAXIMUM FROM THE FRONT OF THE UNIT, THE <br />ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM. <br />3. SANITARY FACILITIES: <br />A. WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC <br />CLOSING DEVICE, AND SHALL HAVE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32" INCHES WHEN <br />LOCATED AT THE END AND 34" INCHES WHEN LOCATED AT THE SIDE WITH THE DOOR POSITION AT AN <br />ANGLE OF 90 DEGREES AWAY FROM ITS CLOSED POSITION. <br />3. SWITCHES, CONTROLS AND ELECTRICAL OUTLETS:(REFER TO DETAIL ) <br />A. ELECTRICAL AND COMMUNICATION SYSTEMS OUTLETS SHALL BE MOUNTED NOT LESS THAN 15 <br />INCHES ABOVE THE FLOOR OR WORKING PLATFORM. <br />B. THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES AND OTHER <br />OPERABLE EQUIPMENT SHALL BE 48" MAXIMUM AND 15" MINIMUM ABOVE THE FINISH FLOOR OR <br />WORKING PLATFORM AT BOTH FORWARD AND PARALLEL APPROACH PER CBC 11B-308.2.1 AND <br />11B-308.3.1 <br />C. IF REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, A BASE CABINET) BETWEEN 20" AND 25" IN <br />DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH. FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO <br />46". THE OBSTURCTION MAY NOT EXTEND MORE THAN 24" FROM THE WALL BENEATH THE CONTROL. <br />D. FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" ABOVE THE LEVEL OF THE FLOOR, <br />WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. <br />E. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED THEY SHALL ACTIVATE A MEANS OF WARNING <br />THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN <br />60 FLASHES PER MINUTE. <br />F. WARNING SYSTEMS SHALL COMPLY WITH NFPA 72 AND 72G (AS AMENDED BY CHAPTER 35) AND <br />SHALL PROVIDE VISUAL ALARMS (I.E. STROBES) IN RESTROOMS, CORRIDORS, MULTI-PURPOSES <br />ROOMS, LOBBIES, MEETING ROOMS, AND ANY OTHER COMMON USE ROOMS (CBC 11B-702.1). <br />4. ADDITIONAL COMPLIANCE REQUIREMENTS: <br />A. AT LEAST 5%, AND A MINIMUM WIDTH OF 30", OF EACH TABLE/COUNTER WORK SURFACE AND/OR <br />TRANSACTION STATION IN EMPLOYEE WORK AREAS, SHALL HAVE A SURFACE BETWEEN 28" AND 34" <br />ABOVE THE FLOOR( CBC 11B-203.9). <br />B. ALL ACCESSIBLE AT TABLES OR COUNTERS SHALL PROVIDE KNEE CLEARANCE OF AT LEAST 27" <br />HIGH, 30" WIDE, AND 19" DEEP (11B-902.2, 11B-306.3.3 & 11B-306.3.5) <br />11 <br />A62.3 <br />5 <br />- <br />3 <br />- <br />6 <br />- <br />STAFF TOILET ROOM PLUMBING FIXTURE HEIGHTS/DIMENSIONS <br />9" <br />(19" MIN. FOR SINK) <br />17" MIN. <br />6" MAX. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />@ <br />A <br />P <br />R <br />O <br />N <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />6" <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />INSULATED <br />PIPES <br />ELEVATIONSECTION <br />LAVATORY NOTES: <br />1. THERE SHALL BE NO SHARP OR ABRASIVE <br />SURFACES UNDER THE LAVATORY. <br />2. ALL HOT WATER & DRAIN PIPES ACCESSIBLE <br />UNDER LAVATORIES MUST BE INSULATED OR <br />OTHERWISE COVERED. <br />BACKSPLASH <br />WHERE <br />OCCURS <br />PLAN <br />GRAB BAR, <br />SEE ELEVATION <br />@ SIDE DOOR <br />60" MIN. CLR <br />RECESSED TOILET <br />ACCESSORIES, <br />SEE PLAN & <br />ELEVATIONS <br />17 <br />" <br /> <br />- <br /> <br />1 <br />8 <br />" <br />SIDE DOOR <br />34" MIN. CLR <br />@ <br />A <br />P <br />R <br />O <br />N <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />4" <br />MIN. TO SIDEWALL <br />OR FIXTURE CLEAR <br />SPACE <br />MAX. PROJECTION <br />OF ACCESSORIES <br />FACE OF WALL <br />FO <br />F <br />FACE OF WALL <br />1' - 6" <br />ACCESSIBLE STD. <br />URINAL <br />1' <br /> <br />- <br /> <br />3 <br />" <br />MA <br />X <br />. <br />1' <br /> <br />- <br /> <br />5 <br />" <br />32" MIN. CLR <br />4' <br /> <br />- <br /> <br />0 <br />" <br />MIN. <br />1' - 6"STRIKE SIDE CLEARANCE <br />2' <br /> <br />- <br /> <br />0 <br />" <br />SIDE <br />ELEVATION <br />FRONT <br />ELEVATION <br />T. <br />O <br />. <br /> <br />R <br />A <br />I <br />L <br /> <br /> <br />3 <br />6 <br /> <br />" <br />24" MIN. <br />54" MIN. <br />FLUSH VALVE <br />@ WIDE SIDE <br />GRAB BAR <br />4' - 6" <br />FOF <br />17" - 18" <br />T. <br />O <br />. <br />S <br />. <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />MIN. <br />1' - 0" <br />MIN. <br />2' - 0" <br />GRAB BAR <br />3' - 0" MIN. <br />13-1/2" MIN. <br />PROJECTION FROM <br />WALL (CBC <br />11B-605.2) <br />36" MIN. CLEAR <br />WHERE WALLS OR <br />PROJECTIONS <br />EXTEND MORE THAN <br />24" FROM FRONT OF <br />CLEAR SPACE <br />4" MAX. <br />EN <br />D <br /> <br />D <br />O <br />O <br />R <br />32 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />5' <br /> <br />- <br /> <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />@ END DOOR <br />48" MIN. CLR <br />FLOOR-MOUNTED TOILET <br />59" MIN (INWARD SWING DOOR) <br />TOILET ROOM ACCESSORY MOUNTING HEIGHTS <br />PAPER TOWEL <br />DISPENSER & WASTE <br />SECTION - <br />FULLY RECESSED <br />ELEVATION SECTION - <br />SEMI-RECESSED <br />4" <br />MAX. <br />3' <br /> <br />- <br /> <br />4 <br />" <br />P.T. <br />DISP. <br />FRAMELESS MIRROR <br />(SIZE PER INTERIOR <br />ELEVATIONS) <br />MIRROR 35 <br />" <br /> <br />M <br />A <br />X <br /> <br />O <br />T <br />H <br />E <br />R <br />W <br />I <br />S <br />E <br />40 <br />" <br /> <br />M <br />A <br />X <br /> <br />O <br />V <br />E <br />R <br /> <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br /> <br />O <br />R <br /> <br />L <br />A <br />V <br />O <br />R <br />A <br />T <br />O <br />R <br />Y <br />TO <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br /> <br />O <br />F <br /> <br />RE <br />F <br />L <br />E <br />C <br />T <br />E <br />D <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br />27 <br />" <br /> <br />M <br />A <br />X <br />. <br />8" MIN. <br />MA <br />X <br />. <br />4" <br />. <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />T. <br />O <br />. <br /> <br />R <br />A <br />I <br />L <br /> <br />3 <br />6 <br /> <br />" <br />TY <br />P <br />. <br />1' <br /> <br />- <br /> <br />0 <br />" <br />EQ. EQ. <br />PAPER TOWEL <br />DISPENSER AND <br />WASTE RECEPTACLE <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />SOAP DISPENSERS <br />FIXTURE MOUNTING <br />SINK AND MIRROR URINAL & URINAL SCREENS FLOOR & WALL MOUNTED WC <br />NOTE: <br />VERIFY LOCATION OF BLOCKING WITH TYPE AND LOCATION OF FIXTURE OR PARTITION <br />BEFORE INSTALLATION, SEE PLAN FOR ACTUAL FIXTURE LOCATION. REFER TO <br />MANUFACTURER FOR RECOMMENDED MOUNTAING HARDWARE. <br />TYPICAL MIRROR SUPPORT: <br />4" X 20 GA STEEL TRACK, ATTACH TO (2) STUDS MIN. WITH (3) #8 <br />S.M.S. EACH STUD, CUT AND BEND FLANGES TO STUDS, EXTEMD 4" <br />MAX AT ENDS. <br />TYPICAL FIXTURE AND PARTITION <br />SUPPORT: 4" X 16 GA STEEL TRACK, <br />ATTACH TO (3) STUDS MIN WITH (3) # <br />8 S.M.S. EACH STUD, CUT AND BEND <br />FLANGES AT STUDS, EXTEND 4" MAX <br />AT ENDS. COORDINATE WITH <br />PLUMBING BRACKET, TYP. <br />HAND DRYER <br />MA <br />X <br />. <br />3' <br /> <br />- <br /> <br />4 <br />" <br /> <br /> <br />A <br />F <br />F <br />8" 3" <br />ELECTRIC HAND <br />DRYER REFER TO <br />ELECTRICAL <br />DWGS. FOR <br />POWER <br />FLOOR-MOUNTED TOILET <br />59" MIN (INWARD SWING DOOR) <br />FLOOR-MOUNTED TOILET <br />59" MIN (INWARD SWING DOOR) <br />56" MIN (INWARD SWING DOOR) <br />TOILET PARTITION SYSTEM <br />PARTITION OR WALL-MOUNTED <br />TOILET TISSUE DISPENSER (& <br />FEMININE NAPKIN DISPOSAL IN <br />WOMEN'S RESTROOMS) <br />GRAB BARS. FOR <br />MOUNTING SEE DET. <br />FIN. FLOOR 1' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />2' <br /> <br />- <br /> <br />4 <br />" <br />TOILET TISSUE DISPENSER <br />LOCATED WITHIN 7" - 9" OF THE <br />FRONT EDGE OF THE TOILET SEAT <br />FACE OF WALL <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />TOILET COMPARTMENT ACCESSORIES <br />INDIVIDUAL ITEMS <br />7" - 9" <br />36" MAX. <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br />11 <br />A62.3 <br />NOTES: <br />1. REFER TO SPECIFICATIONS AND TOILET ACCESSORY SCHEDULE FOR MORE INFORMATION. <br />2. FOR TOILET PARTITIONS REFER TO SPECIFICATIONS AND DETAIL <br />3. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION ON SPECIFIC FIXTURES. <br />TY <br />P <br />I <br />C <br />A <br />L <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br />5' <br /> <br />- <br /> <br />0 <br />" <br />4' - <br />0 <br />" <br />44 <br />" <br /> <br />@ <br /> <br />D <br />O <br />O <br />R <br />S <br /> <br />W <br />I <br />T <br />H <br />O <br />U <br />T <br /> <br />CL <br />O <br />S <br />E <br />R <br /> <br />& <br /> <br />L <br />A <br />T <br />C <br />H <br />48 <br />" <br /> <br />@ <br /> <br />D <br />O <br />O <br />R <br />S <br /> <br />W <br />I <br />T <br />H <br />4' - 0" <br />MIN. CLR <br />2' - 10"CLOSERS & LATCH <br />12" MIN. CLR AT DOORS W/ <br />LEVEL LANDING AT BOTH SIDES OF <br />DOOR (@ EXTERIOR - 2% MAX SLOPE <br />ALLOWED IN EITHER DIRECTION) - <br />CLEARANCES PER CBC FIGURE <br />11B-404.2.4.1 <br />24" MIN. CLR @ OUT-SWINGING EXT.DOORS <br />18" MIN. CLR @ INTERIOR DOORS <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />REACH DEPTH <br />10" MAX. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />REACH DEPTH <br />10" MAX. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />GREATER THAN <br />10" TO 24" MAX <br />TO 25" MAX. <br />REACH DEPTH <br />GREATER THAN 20" <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />UNOBSTRUCTED <br />SIDE REACH <br />OBSTRUCTED HIGH SIDE REACH <br />OBSTRUCTED HIGH FORWARD REACH <br />11B-308.2.2 <br />11B-902.3 <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />REACH DEPTH <br />20" MAX <br />UNOBSTRUCTED <br />FORWARD REACH <br />REACH RANGE NOTES <br />FORWARD REACH TO WALL MOUNTED OBJECTS W/O OBSTRUCTIONS <br />• 30"x48" CLEAR FLOOR SPACE FOR FORWARD APPROAC IS PROVIDED TO <br />OBJECT. <br />• ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE ADJOINS AN <br />ACCESIBLE ROUTE OR ADJOINTS ANOTHER WHEELCHAIR CLEAR FLOOR SPACE <br />SIDE REACH - WALL MOUNTED OBJECTS W/0 OBSTRUCTIONS <br />• 30"x48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH IS PROVIDED AT <br />OBJECT. <br />• ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE ADJOINS AN <br />ACCESIBLE ROUTE OR ADJOINTS ANOTHER WHEELCHAIR CLEAR FLOOR SPACE <br />AISLE <br />48" CLR. MIN. <br />FORWARD APPROACH (KNEE UNDER COUNTER)SIDE APPROACH <br />AISLE <br />36" CLR. MIN. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />27 <br />" <br /> <br />M <br />I <br />I <br />N <br />. <br />28 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />- <br /> <br />3 <br />4 <br />' <br /> <br />M <br />A <br />X <br />. <br />28 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />- <br /> <br />3 <br />4 <br />' <br /> <br />M <br />A <br />X <br />. <br />ELEVATION <br />3' <br /> <br />- <br /> <br />6 <br />" <br /> <br />U <br />. <br />N <br />. <br />O <br />. <br />8" MIN. <br />ELEC. <br />SWITCH <br />T-STAT <br />TELE/CRT <br />POWER <br /> 1' - 0" MAX. <br />2'-0" AT PARTY WALLS <br />AND AREA <br />SEPEARATIONS <br />OUTLETS SECTION <br />HORIZONTAL METAL STRAP <br />BETWEEN STUDS <br />1' - 0" MAX. <br />TELE/DATA/POWER <br />J-BOXES <br />MI <br />N <br />. <br />1' <br /> <br />- <br /> <br />3 <br />" <br /> <br />NOTES: <br />1. REF PLANS FOR FIXTURE LOCATIONS. <br />2. ALL AREAS AFFECTED BY INSTALLATION OF NEW D.F. SHALL BE <br />PATCHED AND REPAINTED TO MATCH (E) TEXTURE AND FINISH. <br />3. REFERENCE THE ELECTRICAL DRAWINGS FOR POWER. <br />ELEVATION <br />CL <br />27 <br />" <br /> <br />M <br />I <br />N <br />SP <br />O <br />U <br />T <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />36 <br />" <br /> <br />M <br />A <br />X <br />BACK PANEL <br />PUSH BUTTON <br />CONTROL, <br />TYP. <br />ACCESSIBLE <br />LOCATION <br />32" MIN CLR <br />PLAN <br />30"X48" <br />REQUIRED <br />CLEAR FLOOR <br />SPACE <br />18 <br />" <br />- <br />1 <br />9 <br />" <br />ACCESSIBLE <br />LOCATION <br />1' - 3" 1' - 3" <br />3" <br /> <br />M <br />A <br />X <br />. <br />TY <br />P <br />. <br />1' <br /> <br />- <br /> <br />6 <br />" <br />3' - 10" <br />PIPE RAILS <br />PER DETAIL <br />SP <br />O <br />U <br />T <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />38 <br />" <br /> <br />T <br />O <br /> <br />4 <br />3 <br />" <br /> 1'-4" MIN.1' - 6" <br />CLCLPIPE RAILS <br />1' - 3"1' - 3" <br />3 <br />A62.3 <br />12 <br />A62.3 <br />WIDTH PER INT. ELEVATION <br />KN <br />E <br />E <br />S <br />P <br />A <br />C <br />E <br />2' <br /> <br />- <br /> <br />3 <br />" <br />30" MIN. CLR. <br />ADJACENT CASEWORK WHERE OCCURS <br />REFER TO INTERIOR ELEVATIONS <br />COUNTERTOP AS SCHEDULED <br />2' <br /> <br />- <br /> <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />HATCHED AREA <br />MUST BE <br />ACCESSIBLE <br />4" <br />2' - 0" <br />WALL PER PLAN <br />INSULATE HOT WATER PIPE & DRAIN, TYP. THERE SHALL BE <br />NO SHARP OR ABRASIVE OBJECTS OR SURFACES UNDER <br />SINK <br />ACCESSIBLE UNDERMOUNT VANITY W/ WITH MAX DEPTH <br />OF 6-1/2", REFER TO PLUMBING <br />KN <br />E <br />E <br />S <br />P <br />A <br />C <br />E <br />2' <br /> <br />- <br /> <br />3 <br />" <br />MAX. <br />6" <br />4" <br />1" <br />ANCHORAGE AT BASE AND WALL PER TYPICAL <br />CASEWORK ANCHORAGE DETAIL 13/A62.1. <br />3' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0" <br />VAN1' <br /> <br />- <br /> <br />0 <br />" <br />NOTE: <br />1. ACCESSIBILITY SIGNACE SHALL COMPLY WITH SECTION 11B-502.6 <br />WHITE EMBLEM <br />WHITE STRIPING <br />3'-0" X 3'-0" PAINTED <br />INTERNATIONAL SYMBOL <br />OF ACCESSIBLITY <br />BLUE FIELD COLOR <br />SHALL BE EQUAL TO <br />COLOR NO. 15090 FEDERAL <br />STANDARD 595a <br />12" HIGH LETTERS <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />07/08/24 <br />GEN-4 <br />GENERAL <br />ACCESSIBILITY <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />ACCESSIBILITY NOTES <br />3/8" = 1'-0"1TOILET ROOM ACCESSORIES AND PLUMBING FIXTURE HEIGHT3/8" = 1'-0"5ACCESSIBLE DOOR LANDING <br />3/8" = 1'-0"2ACCESSIBLE REACH RANGE <br />3/8" = 1'-0"6ACC. SWITCH CONTROLS & OUTLETS <br />1/2" = 1'-0"3ACC. DUAL HEIGHT DRINKING FOUNTAIN <br />3/4" = 1'-0"4ACCESSIBLE SINK W/ CASEWORK <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25 <br />3 ASI #03 07/02/25 <br />1" = 1'-0"7ADA ACCESSIBLITY SYMBOL