Laserfiche WebLink
7' <br /> <br />X <br /> <br />1 <br />9 <br />" <br /> <br />R <br />A <br />C <br />K <br />7' <br /> <br />X <br /> <br />6 <br />" <br /> <br />W <br />M <br />1 <br />2 <br />3 <br />6 <br />7 <br />8 <br />5 <br />2 <br />7 <br />1 <br />4 <br />3 <br />8 <br />6 <br />4 <br />5 <br />8 <br />6 <br />9 <br />1 <br />6 <br />7 5 <br />2 <br />9 <br />8 <br />4 <br />3 <br />6 <br />5 <br />6 <br />1 TYP <br />3 TYP <br />22 F2 <br />6 <br />TYP <br />TYP <br />5 <br />4 <br />2 <br />6 <br />10TYP <br />6 <br />2 <br />OBLIQUE VIEW <br />11 <br />12 <br />10 <br />11 <br />12 <br />4 <br />TYP <br />10 <br />TYP <br />TYP <br />PROVIDE FACEPLATE LABELING PER SPECIFICATIONS. SEE SPECIFICATIONS FOR ALL OTHER <br />LABELING REQUIREMENTS. <br />PROVIDE FACEPLATE PER SPECIFICATIONS. FACEPLATE MATERIAL AND FINISH SHALL MATCH <br />ADJACENT / NEARBY POWER FACEPLATES. PROVIDE FLOOR BOX, POWER POLE & MODULAR <br />FURNITURE DEVICE BRACKETS / CUSTOM ADAPTERS AS REQUIRED FOR A COMPLETE <br />INSTALLATION. INCLUDE ALL COSTS IN BASE BID. <br />PROVIDE CAT-6 STATION CONNECTOR PER SPECIFICATIONS. COLOR PER SPECIFICATIONS. <br />PROVIDE (1) CAT-6, 4 PAIR UTP CABLE(S), COLOR OF CABLE(S) SHALL BE BLUE. TERMINATE <br />STATION END(S) IN STATION CONNECTOR(S) PER SPECIFICATIONS. TERMINATE RACK END(S) <br />CAT-6 PATCH PANEL(S) AT IDF RACK / CABINET PER SPECIFICATIONS. <br />BLANK INSERT. ALL UNUSED OPENINGS SHALL BE COVERED WITH A BLANK INSERT <br />MATCHING THE COLOR OF THE FACEPLATE. <br />WHERE THE FOLLOWING SYMBOLS ARE INDICATED ON THE ELECTRICAL DRAWINGS <br />ARCHITECTURAL DRAWINGS AND / OR STRUCTURED CABLING SYSTEM DRAWINGS: <br />THE FOLLOWING SHALL BE PROVIDED, AS DEPICTED IN THE FOLLOWING <br />DIAGRAMMATIC CONNECTIVITY DETAIL. <br />WHERE THE FOLLOWING SYMBOLS ARE INDICATED ON THE ELECTRICAL DRAWINGS <br />ARCHITECTURAL DRAWINGS AND / OR STRUCTURED CABLING SYSTEM DRAWINGS: <br />THE FOLLOWING SHALL BE PROVIDED, AS DEPICTED IN THE FOLLOWING <br />DIAGRAMMATIC CONNECTIVITY DETAIL. <br />WAP <br />WHERE THE FOLLOWING SYMBOLS ARE INDICATED ON THE ELECTRICAL DRAWINGS <br />ARCHITECTURAL DRAWINGS AND / OR STRUCTURED CABLING SYSTEM DRAWINGS: <br />THE FOLLOWING SHALL BE PROVIDED, AS DEPICTED IN THE FOLLOWING <br />DIAGRAMMATIC CONNECTIVITY DETAIL. <br />WAP <br />WP <br />WHERE THE FOLLOWING SYMBOLS ARE INDICATED ON THE ELECTRICAL DRAWINGS <br />ARCHITECTURAL DRAWINGS AND / OR STRUCTURED CABLING SYSTEM DRAWINGS: <br />THE FOLLOWING SHALL BE PROVIDED, AS DEPICTED IN THE FOLLOWING <br />DIAGRAMMATIC CONNECTIVITY DETAIL. <br />PROVIDE (1) CAT-6A, 4 PAIR UTP CABLE(S), COLOR OF CABLE(S) SHALL BE BLUE. TERMINATE <br />STATION END(S) IN STATION CONNECTOR(S) PER SPECIFICATIONS. TERMINATE RACK END(S) <br />CAT-6A PATCH PANEL(S) AT IDF RACK / CABINET PER SPECIFICATIONS. <br />PROVIDE CAT-6A STATION CONNECTOR PER SPECIFICATIONS. COLOR PER SPECIFICATIONS. <br />WHERE THE FOLLOWING SYMBOLS ARE INDICATED ON THE ELECTRICAL DRAWINGS <br />ARCHITECTURAL DRAWINGS AND / OR STRUCTURED CABLING SYSTEM DRAWINGS: <br />THE FOLLOWING SHALL BE PROVIDED, AS DEPICTED IN THE FOLLOWING <br />DIAGRAMMATIC CONNECTIVITY DETAIL. <br />WAP <br />H <br />4-SQUARE DEEP BOX AND WEATHERPROOF BLANK FACEPLATE, FLUSH TO EXTERIOR OR <br />INTERIOR WALL OR CEILING, WITH CONDUIT AND CONDUCTORS TO NEAREST IDF DATA <br />ROOM. <br />PROVIDE SURFACE-MOUNT, PLENUM-RATED TWO-PORT HOUSING (LEVITON 41089-2WP OR <br />EQUAL). MOUNT TO CONTRACTOR-PROVIDED IN-CEILING BRACKET WITH MULTI-FUNCTION <br />CLIP FOR ROD OR HANGER WIRE MOUNTING (LEVITON 49223-CBC OR EQUAL). PROVIDE 15FT <br />SLACK LOOP ON J-HOOK MOUNTED ABOVE HOUSINGS. MOUNT HOUSING 12 INCHES ABOVE <br />ACCESSIBLE CEILING TILE. <br />INSTALL DEDICATED SUSPENDED CEILING WIRE/HANGAR OR SUPPORT ROD/ROD HANGAR <br />DIRECTLY TO STRUCTURAL CEILING ABOVE TO SUPPORT WAP SURFACE MOUNT HOUSING. <br />PROVIDE J-HOOK ABOVE ACCESSIBLE CEILING PER SPECIFICATIONS. J-HOOKS SHALL BE <br />SPACED AT A MAXIMUM OF 5 FEET APART. <br />5 <br />3 <br />1 <br />7 <br />DATA DEVICE - 2 PORT <br />FACEPLATE DETAIL KEY NOTES: <br />OUTDOOR WIRELESS ACCESS POINT DEVICE <br />DATA DEVICE - 6 PORT <br />ABOVE CEILING WIRELESS ACCESS POINT DEVICE <br />2 <br />4 <br />WIRELESS ACCESS POINT - FLUSH MOUNT <br />TELECOM BACKBOARD AND PRIMARY BONDING BUSBAR <br />EXISTING RACK MOUNTED FIBER TERMINATION HOUSING. RELOCATE TO 1RU BELOW TOP OF <br />RACK. <br /> LAN RACK ELEVATION KEY NOTES: <br />EXISTING IDF FLOOR MOUNTED RACK. MODIFY AS REQUIRED. <br />TYPICAL IDF RACK ELEVATION DETAIL <br />DUAL PORT, SURFACE MOUNTED BOX (AMP #1116698-1 OR EQUAL) WITH CAT-6 PATCH CORD. <br />2 <br />CONNECT PBB TO ELECTRICAL PANEL GROUND BUS WITH 1/2"C. <br />AND #6AWG GROUND CONDUCTOR, BY E.C.. ALL CONNECTIONS <br />SHALL BE WITH 2-HOLE COMPRESSION LUGS. <br />U.L. LISTED TELECOMMUNICATIONS PRIMARY BONDING BUSBAR <br />(PBB). IN IDF ROOM PROVIDE PBB, CHATSWORTH #40153-012. <br />FINISHED FLOOR <br />8'-6" <br />INCOMING FEED CONDUITS AND INNER-BUILDING CONDUITS. <br />QUANTITY AND SIZE PER PLANS. <br />INNER-BUILDING CONDUITS AND SLEEVES. QUANTITY AND SIZE <br />PER PLANS. <br />TYP. <br />TYP. <br />INDIVIDUAL #6AWG BONDING CONDUCTORS TO EACH CABINET, <br />RACK, LADDER TRAY, CONDUIT, ETC. BY SCS CONTRACTOR. <br />CONNECT TO EQUIPMENT AND TO BONDING BUSBAR VIA 2-HOLE <br />COMPRESSION LUGS ONLY. DAISY-CHAINING OF BONDING <br />CONDUCTOR TO MORE THAN ONE PIECE OF EQUIPMENT IS <br />PROHIBITED. <br />TYP. <br />A.F.F. <br />E <br />C <br />B <br />D <br />F <br />A <br />F <br />E <br />D <br />C <br />B <br />A <br />TELECOM BACKBOARD AND BONDING DETAIL NOTES: <br />WHITE ENAMEL PAINTED A/C GRADE FIRE RATED PLYWOOD <br />TELECOM BACKBOARD, (8' HIGH x 3/4" THICK x WIDTH PER <br />PLANS) BY E.C.. LEAVE ONE FIRE MARSHAL STAMP UNPAINTED <br />ON EACH SHEET. MOUNT 6" ABOVE FINISHED FLOOR. <br />- ANCHOR TO WOOD STUD WALL WITH #14 TRUSS HEAD WOOD <br />SCREWS AT 16" ON CENTER. MINIMUM EMBEDMENT 1-1/2" INTO <br />STUDS. <br />- ANCHOR TO METAL STUD WALL WITH #12 SMS SCREWS AT 16" <br />ON CENTER. <br />- ANCHOR TO CMU WALL WITH 1/4" x 1-5/8" EMBED HILTI KWIK <br />HUS EZ SCREW ANCHOR (ICC ESR 3056). <br />- RECESS ALL SCREWS / BOLTS. <br />6" <br />FINISHED FLOOR <br />1U VACANT <br />1U HORIZONTAL CABLE MANAGER PER SPECIFICATIONS, PROVIDE 1U MANAGER ABOVE AND <br />BELOW EACH PATCH PANEL. <br />RACK MOUNTED 24-PORT CATEGORY-6A PATCH PANEL PER SPECIFICATIONS . QUANTITY AS <br />REQUIRED TO TERMINATE ALL CABLES. <br />EXISTING LADDER RUNWAY. SHOWN FOR REFERENCE. BOND RUNWAY TO TELECOM <br />BUSBAR IN ROOM. REFER TO TELECOM BACKBOARD AND PRIMARY BONDING BUSBAR <br />DETAIL ON THIS PAGE. <br />6" WIDE X 84" HIGH DOUBLE-SIDED VERTICAL CABLE MANAGERS. CHATSWORTH OR EQUAL <br />PER SPECIFICATIONS. <br />TYP <br />TYP <br />SCALE: N.T.S.7 <br />ACTIVE EQUIPMENT IS OWNER FURNISHED OWNER INSTALLED. CONTRACTOR SHALL <br />PROVIDE ALL CAT-6 PATCH CORDS PER SPECIFICATIONS. <br />RACK MOUNTED 48-PORT CATEGORY-6 PATCH PANEL PER SPECIFICATIONS . QUANTITY AS <br />REQUIRED TO TERMINATE ALL CABLES. <br />TYP <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />NOTE: WIRELESS ACCESS POINT ELECTRONICS AND MOUNTS ARE CONTRACTOR <br />FURNISHED CONTRACTOR INSTALLED. INCLUDE ALL COSTS IN BASE BID. <br />NOTE: WIRELESS ACCESS POINT ELECTRONICS AND MOUNTS ARE CONTRACTOR <br />FURNISHED CONTRACTOR INSTALLED. INCLUDE ALL COSTS IN BASE BID. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />TYP <br />TYP <br />TYP <br />TYP <br />1 <br />5 <br />4 <br />3 <br />6 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />04/09/2025 <br />T52.1 <br />TECHNOLOGY <br />DETAILS <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DESCRIPTION DATE <br />1 ASI #1 4/9/251 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1