Laserfiche WebLink
SINGLE SLIDER GLASS DOOR WITH CARD READER & ADA OPERATOR <br />STOREFRONT DOUBLE DOOR CARED READER W / ADA OPERATOR <br />SINGLE DOOR CARED READER <br />ACCESS CONTROL SYSTEM EXAMPLE ELEVATION <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />1 <br />2 <br />3 <br />4 <br />CEILING <br />CEILING <br />FINISHED FLOOR FINISHED FLOOR <br />DOOR NOTES: <br />SECURE SIDENON-SECURE SIDE <br />NON-SECURE SIDE <br />SECURE SIDE <br />FLOOR PLAN DIAGRAM: <br />DC DC <br />DCDC <br />1" CONDUIT, ACS COMPOSITE <br />CABLE(S) TO NEARSET TELECOM <br />ROOM <br />ED <br />ED <br />ET <br />ED <br />ED <br />CR <br />CR <br />J <br />ACS DOOR JUNCTION BOX IN <br />ACCESSIBLE CEILING SPACE <br />EMERGENCY OPERATION NOTE: <br />- DOOR MUST REMAIN UNLOCKED ON THE SECURE SIDE AT ALL TIMES. <br />SEQUENCE OF OPERATION: <br />-DOOR IS LOCKED AT ALL TIMES OR PER BUSINESS SCHEDULE ON THE NON SECURED SIDE. <br />-DOOR IS UNLOCKED ON THE SECURED SIDE AT ALL TIMES. <br />-TO OPEN DOOR FROM THE NON-SECURED SIDE, CARD MUST BE PRESENTED TO UNLOCK DOOR. <br />-REQUEST TO EXIT MOTION DETECTOR BYPASSES ACCESS SYSTEM ALARM ONLY ON EXIT. <br />DOOR COORDINATION NOTE: <br />-REQUEST TO EXIT MOTION SENSOR MAY NOT BE REQUIRED IF DOOR LOCKING HARDWARE HAS AN INTEGRATED <br />REQUEST TO EXIT SENSOR. COORDINATE WITH ARCHITECT AND DOOR HW VENDOR PRIOR TO ROUGH-IN AND <br />INSTALLATION. <br />-REFER TO ARCHITECT DOOR SCHEDULE AND DIV 8 SPEC FOR DOOR HARDWARE INFORMATION. <br />-EACH DOOR PANEL TO BE INDIVIDUALLY WIRED AND HOMERUN TO ACP. <br />MX <br />REX J-BOX. MAY <br />NOT BE REQUIRED. <br />SEE DOOR NOTE. <br />REX <br />MX <br />REX REX <br />PROVIDE ONLY IF DOOR HARDWARE <br />DOES NOT HAVE INTEGRATED REX. <br />REFER TO DOOR HARDWARE <br />SCHEDULE. <br />ELECTRIC POWER <br />TRANSFER HINGE <br />BY DOOR HW <br />VENDOR <br />ELECTRIC POWER <br />TRANSFER HINGE <br />BY DOOR HW <br />VENDOR <br />REX <br />ET <br />3/4" CONDUIT BY E.C. (TYP), <br />LOW VOLTAGE WIRING BY <br />SECURITY CONTRACTOR (TYP) <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 1 <br />1 <br />1 1 <br />1 <br />CEILINGCEILING <br />FINISHED FLOOR FINISHED FLOOR <br />DOOR NOTES: <br />SECURE SIDENON-SECURE SIDE <br />NON-SECURE SIDE <br />SECURE SIDE <br />1" CONDUIT, ACS COMPOSITE CABLE <br />TO NEARSET TELECOM ROOM <br />FLOOR PLAN DIAGRAM: <br />EMERGENCY OPERATION NOTE: <br />-NO EMERGENCY OPERATION NOTE <br />DC <br />SEQUENCE OF OPERATION: <br />-NORMAL DOOR STATE IS CLOSED AT ALL TIMES. <br />-DOOR IS LOCKED ON THE NON-SECURED SIDE AND UNLOCKED ON THE SECURED SIDE. <br />-TO OPEN DOOR FROM NON-SECURED SIDE, CARD MUST BE PRESENTED TO UNLOCK DOOR. <br />-REQUEST TO EXIT SENSOR BYPASSES ACCESS SYSTEM ALARM ONLY ON EXIT. <br />DC <br />MX <br />MX <br />EL <br />EL <br />CR <br />CR <br />ELECTRIC HINGE BY <br />DOOR HW VENDOR <br />J <br />CARD READER J-BOX, MAX 48" AFF. <br />SEE LOCATION PER PLANS. <br />MX J-BOX. <br />MAY NOT BE <br />REQUIRED. <br />SEE DOOR <br />NOTE. <br />ACS DOOR JUNCTION BOX IN <br />ACCESSIBLE CEILING SPACE <br />3/4" CONDUIT BY E.C. (TYP), <br />LOW VOLTAGE WIRING BY <br />SECURITY CONTRACTOR (TYP) <br />DOOR COORDINATION NOTE: <br />-REQUEST TO EXIT MOTION SENSOR MAY NOT BE REQUIRED IF DOOR LOCKING HARDWARE HAS AN INTEGRATED <br />REQUEST TO EXIT SENSOR. COORDINATE WITH ARCHITECT AND DOOR HW VENDOR PRIOR TO ROUGH-IN AND <br />INSTALLATION. <br />-REFER TO ARCHITECT DOOR SCHEDULE AND DIV 8 SPEC FOR DOOR HARDWARE INFORMATION. <br />REX <br />REX <br />PROVIDE ONLY IF DOOR HARDWARE <br />DOES NOT HAVE INTEGRATED REX. <br />REFER TO DOOR HARDWARE <br />SCHEDULE. <br />EH <br />DOOR HARDWARE <br />BY HW VENDOR <br />CEILINGCEILING <br />FINISHED FLOOR FINISHED FLOOR <br />DOOR NOTES: <br />SECURE SIDENON-SECURE SIDE <br />NON-SECURE SIDE <br />SECURE SIDE <br />1" CONDUIT, ACS COMPOSITE CABLE <br />TO NEARSET TELECOM ROOM <br />FLOOR PLAN DIAGRAM: <br />EMERGENCY OPERATION NOTE: <br />-NO EMERGENCY OPERATION NOTE <br />DC <br />DC <br />MX <br />CR <br />CR <br />J <br />MULLION MOUNTED CARD READER, <br />MAX 48" A.F.F. SEE LOCATION PER <br />PLANS. <br />ACS DOOR JUNCTION BOX IN <br />ACCESSIBLE CEILING SPACE <br />DOOR COORDINATION NOTE: <br />-REFER TO ARCHITECT DOOR SCHEDULE AND DIV 8 SPEC FOR DOOR OPERATOR, LOCKSET, AND DOOR <br />HARDWARE INFORMATION. DOOR AUTO-LOCK BY DOOR HARDWARE VENDOR. <br />-ELECTRICAL CONTRACTOR TO PROVIDE 120 VAC FOR DOOR OPERATOR POWER SUPPLY. <br />-DOOR OPERATOR SHALL BE INTEGRATED WITH ACCESS CONTROL SYSTEM BY ACCESS CONTROL CONTRACTOR, <br />REFER TO DOOR HARDWARE SCHEDULE. <br />OPERATOROPERATOR <br />SEQUENCE OF OPERATION: <br />-DOOR IS LOCKED AT ALL TIMES / PER USER SCHEDULE ON THE NON SECURED SIDE. <br />-DOOR IS UNLOCKED ON THE SECURED SIDE AT ALL TIMES. <br />-TO OPEN DOOR FROM NON-SECURED SIDE, CARD MUST BE PRESENTED TO UNLOCK DOOR. <br />-REQUEST TO EXIT MOTION DETECTOR BYPASSES ACCESS SYSTEM ALARM ONLY ON EXIT. <br />3/4" CONDUIT BY E.C. (TYP), <br />LOW VOLTAGE WIRING BY <br />SECURITY CONTRACTOR (TYP) <br />MX <br />ACCESS CONTROL SYSTEM <br />INTEGRATION TO DOOR <br />HARDWARE, SEE DOOR <br />NOTES <br />1 1 1 <br />1 <br />1 <br />AMAG <br />8DBC <br />AMAG <br />8DC, <br />FUTURE <br />AMAG <br />TRNSAC <br />4 X4 NEMA 1 <br />GUTTER <br />AMAG CAB5 <br />PANEL <br />ENCLOSURE <br />ALTRONIX <br />POWER <br />SUPPLY <br />WITH ACM8 <br />ACCESS SYSTEM ELEVATION NOTES: <br />-ACCESS CONTROL SYSTEM ELEVATION IS DIAGRAMMATIC <br />ONLY. ACCESS CONTROL CONTRACTOR IS RESPONSIBLE FOR <br />FINAL DESIGN, LAYOUT, AND QUANTITY OF ALL ACCESS <br />CONTROL SYSTEM COMPONENTS. <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />12" = 1'-0" <br />04/09/2025 <br />T52.2 <br />TECHNOLOGY <br />DETAILS <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DESCRIPTION DATE <br />1 ASI #1 4/9/25 <br />1 <br />1 <br />1 <br />1 <br />1