CR <br />ACP <br />CR <br />CR <br />CR <br />CR <br />CR <br />CR <br />CR <br />1 <br />2 <br />3 <br />4 <br />5 <br />2 <br />1 <br />3 <br />LOCAL AREA NETWORK (LAN) - VOIP SYSTEM DIAGRAM <br />ALL CABLING SHALL BE RATED FOR THE ENVIRONMENT FOR WHICH IT IS INSTALLED, PER <br />CALIFORNIA ELECTRICAL CODE AND TIA-568-C. <br />PROVIDE COMPLETE WITH ALL CABLES, DEVICES, MATERIAL, TERMINATIONS, TESTING, <br />AND LABOR, PER THE SPECIFICATIONS. <br />ACCESS CONTROL SYSTEM DIAGRAM <br />AMAG M2150 CONTROLLERS, POWER SUPPLY(S), LOCKABLE WALL MOUNT ENCLOSURE, ETCETERA, AS <br />REQUIRED. PROVIDE QUANTITIES AS REQUIRED TO ACCOMMODATE ALL ACCESS CONTROLLED <br />ELECTRIFIED DOOR HARDWARE, CARD READERS, ETCETERA, FOR A COMPLETE AND FULLY FUNCTIONAL <br />SYSTEM. <br />PROVIDE CATEGORY-6 PATCH CORD(S) AND CONNECT TO OWNER PROVIDE LAN NETWORK SWITCH. <br />COORDINATE CONNECTION AND VPN WITH OWNER IN FIELD. <br />PROVIDE RELAY AND CONNECTIONS TO FIRE ALARM CONTROL PANEL SO THAT POWER SUPPLIES SHALL <br />RELEASE ALL DEVICES UPON ACTIVATION OF FIRE ALARM SYSTEM. COORDINATE WITH FIRE ALARM <br />CONTRACTOR IN THE FIELD. <br />DEVICE CABLING PER DEVICE MANUFACTURER'S REQUIREMENTS. CABLE SHALL BE RATED FOR THE <br />ENVIRONMENT IN WHICH IT IS INSTALLED. <br />PROVIDE WALL MOUNTED PROXIMITY CARD READER PER SPECIFICATIONS. QUANTITY AND LOCATIONS <br />PER PLAN DRAWINGS. PROVIDE MULLION MOUNTED CARD READER WHEN SHOWN ON FLOOR PLANS. <br />RACK MOUNT CATEGORY-6 PATCH PANEL, INSTALL IN EXISTING IDF RACK. QUANTITY AS REQUIRED <br />TO TERMINATE ALL CAT-6 CABLES ON THIS PROJECT. SEE SPECIFICATIONS FOR MORE <br />INFORMATION. PROVIDE MACHINE GENERATED LABELS. <br />RACK MOUNT CATEGORY-6A PATCH PANEL, INSTALL IN EXISTING IDF RACK. QUANTITY AS <br />REQUIRED TO TERMINATE ALL CAT-6A CABLES ON THIS PROJECT. SEE SPECIFICATIONS FOR MORE <br />INFORMATION. PROVIDE MACHINE GENERATED LABELS. <br />INTERIOR WIRELESS ACCESS POINT (WAP) OUTLET. SEE FACEPLATE DETAILS AND LAN CABLE <br />SCHEDULE FOR MORE INFORMATION. QUANTITY AND LOCATIONS PER PLAN DRAWINGS. WAP <br />ELECTRONICS AND MOUNTS ARE C.F.C.I. REFER TO FACEPLATE DETAILS FOR SPECIFIC OUTLET <br />REQUIREMENTS FOR HARD LID AND ACCESSIBLE CEILINGS. <br />DUAL CATEGORY-6 OUTLET. SEE FACEPLATE DETAILS, AND LAN CABLE SCHEDULE FOR MORE <br />INFORMATION. QUANTITY AND LOCATIONS PER PLAN DRAWINGS. <br />EXTERIOR WIRELESS ACCESS POINT (WAP) OUTLET IN WEATHERPROOF SURFACE MOUNT J-BOX. <br />SEE FACEPLATE DETAILS AND LAN CABLE SCHEDULE FOR MORE INFORMATION. QUANTITY AND <br />LOCATIONS PER PLAN DRAWINGS. WAP ELECTRONICS AND MOUNTS ARE C.F.C.I. <br />EXISTING FIBER OPTIC CABLE HOUSING, PROTECT IN PLACE. <br />FLOOR BOX CATEGORY -6 OUTLET. PROVIDE # NUMBER OF CABLES. SEE FACEPLATE DETAILS, AND <br />LAN CABLE SCHEDULE FOR MORE INFORMATION. QUANTITY AND LOCATIONS PER PLAN DRAWINGS. <br />EXISTING SURVEILLANCE CAMERA WITH OUTLET, PROTECT IN PLACE. <br />REUSE EXISTING IDF RACK. REFER TO RACK ELEVATION DETAIL FOR MORE INFORMATION. <br />CATEGORY-6 CABLES PER LAN CABLE SCHEDULE ON THIS PAGE. REFER TO THE SPECIFICATIONS <br />FOR ADDITIONAL REQUIREMENTS. TERMINATE CAT-6 CABLES ON CAT-6 PANELS. <br />CATEGORY-6A CABLES PER LAN CABLE SCHEDULE ON THIS PAGE. REFER TO THE SPECIFICATIONS <br />FOR ADDITIONAL REQUIREMENTS. TERMINATE CAT-6A CABLES ON CAT-6A PANELS. <br />EXISTING OPTICAL FIBER, PROTECT IN PLACE. <br />QUAD CATEGORY-6 OUTLET. SEE LAN CABLE SCHEDULE FOR MORE INFORMATION. TERMINATE <br />INSIDE ABOVE CEILING PROJECTOR HOUSING IN SURFACE-MOUNT QUICKPORT BOX, 4-PORT <br />LEVITON #41089-4WP. COORDINATE WITH AV CONTRACTOR IN FIELD. <br />REFERENCE SPECIFICATIONS, CITY STANDARDS AND FACEPLATE DETAILS FOR <br />ADDITIONAL INFORMATION AND REQUIREMENTS. <br />1.DRAWINGS AND LAYOUTS ARE PRIMARILY DIAGRAMMATIC IN NATURE. CONTRACTOR IS <br />RESPONSIBLE FOR FINAL FOOTAGES AND EXACT LOCATIONS. <br />2. <br />LAN - VOIP SYSTEM GENERAL NOTES: <br />3. <br />4. <br />2D <br />LAN/VOIP CABLE SCHEDULE <br />DESIGNATOR CABLE QUANTITY AND TYPE <br />TWO (2) CATEGORY-6 UTP 4-PAIR CABLES <br />6A <br />OF EXISTING OPTICAL FIBER, PROTECT IN PLACE <br />6A TWO (2) CATEGORY-6A UTP 4-PAIR CABLES <br />2D <br />LAN / VOIP SYSTEM BLOCK DIAGRAM KEY NOTES: <br />6A <br />WP <br />WAP <br />WAP <br />UNLESS OTHERWISE NOTED IN SPECIFICATIONS OR PLAN DRAWINGS, PROVIDE ONE (1) <br />3-FOOT AND ONE (1) 10-FOOT CAT-6 PATCH CORD FOR EVERY CAT-6 CABLE TERMINATED. <br />INCLUDE ALL COSTS IN BASE BID. <br />5. <br />UNLESS OTHERWISE NOTED IN SPECIFICATIONS OR PLAN DRAWINGS, PROVIDE ONE (1) <br />3-FOOT AND ONE (1) 10-FOOT CAT-6A PATCH CORD FOR EVERY CAT-6A CABLE <br />TERMINATED. INCLUDE ALL COSTS IN BASE BID. <br />6. <br />WAP <br />H <br />OR <br />IDF <br />108 <br />2D <br />2 <br />6D <br />6 <br />6D TWO (2) CATEGORY-6 UTP 4-PAIR CABLES <br />DRAWINGS AND LAYOUTS ARE PRIMARILY DIAGRAMMATIC AND CONCEPTUAL IN NATURE. <br />CONTRACTOR IS RESPONSIBLE FOR FINAL FOOTAGES AND EXACT LOCATIONS. <br />SECURITY CONTRACTOR SHALL COORDINATE I.P. ADDRESS REQUIREMENTS AND <br />CONFIGURATION WITH THE OWNER'S I.T. DEPARTMENT ON SITE. <br />ACCESS CONTROL SYSTEM GENERAL NOTES: <br />SECURITY CONTRACTOR SHALL CHECK THE ARCHITECT'S DOOR HARDWARE SCHEDULE FOR <br />ALL RELATED COMPONENTS AND PROVIDE WHEN SPECIFICALLY REQUIRED BY THE <br />SECURITY CONTRACTOR. <br />ALL ACCESS CONTROL DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE <br />WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. <br />DOORS WITH OPPOSITE HAND SWINGS ARE MIRRORED VERSION OF THE DETAILS SHOWN ON <br />THIS SHEET. SEE ARCHITECTURAL PLANS FOR CORRECT DOOR SWING AND CARD READER <br />LOCATIONS. <br />ALL CONDUITS AND JUNCTION BOXES SHALL BE CONCEALED UNLESS OTHERWISE NOTED ON <br />PLANS OR SPECIFICATIONS. SOME INSTALLATIONS MAY REQUIRE ROUTING CONDUITS <br />UNDERGROUND AND/OR WITHIN TILT-UP CONCRETE PANELS, ETCETERA. COORDINATE <br />INSTALLATION WITH ALL OTHER TRADES AS REQUIRED. CONDUIT AND PULL BOXES SHALL BE <br />PROVIDED AND INSTALLED PER COMMUNICATIONS PATHWAYS GENERAL NOTES AND PER <br />DIVISION 26 ELECTRICAL SPECIFICATIONS. <br />SECURITY CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS AS OUTLINED IN 2019 <br />CBC 1010.1.9.8 FOR ALL ACCESS CONTROL DOORS AS REQUIRED. <br />ALL DEVICE HEIGHTS DEPICTED SHALL BE MODIFIED AS REQUIRED BY GOVERNING BUILDING <br />CODES. CONTRACTOR TO VERIFY/RECONCILE APPLICABLE CODE REQUIREMENTS AND ANY <br />DEVICE HEIGHT REQUIREMENTS DEPICTED ON ARCHITECTURAL OR INTERIOR DESIGN PLANS <br />& SPECIFICATIONS PRIOR TO DEVICE ROUGH-IN. CONFLICTS OR LACK OF MOUNTING HEIGHT <br />SPECIFICITY ON THE ARCHITECTURAL OR INTERIOR DESIGN PLANS & SPECIFICATIONS SHALL <br />BE CAUSE FOR THE CONTRACTOR TO ISSUE A FORMAL WRITTEN RFI FOR RESOLUTION. <br />DEVICE MOUNTING HEIGHT CLARIFICATIONS/SPECIFICATIONS SHALL NOT RESULT IN AN <br />ADDITIONAL COST TO THE OWNER - SECURITY CONTRACTOR SHALL INCLUDE ALL COSTS IN <br />BASE BID. <br />THE ACCESS CONTROL SYSTEM SHALL BE CONNECTED TO FIRE ALARM SYSTEM IN <br />COMPLIANCE WITH NFPA 72. SECURITY CONTRACTOR SHALL INSTALL CABLE FROM ACCESS <br />CONTROL SYSTEM AND COIL CABLE AT FIRE ALARM PANEL. FIRE ALARM CONTRACTOR SHALL <br />TERMINATE SECURITY CABLE TO FIRE ALARM PANEL. SECURITY CONTRACTOR SHALL <br />TERMINATE CABLE AT ACCESS CONTROL PANEL. SECURITY CONTRACTOR SHALL PROVIDE <br />ALL REQUIRED RELAYS AND OTHER COMPONENTS REQUIRED TO CONNECT TO FIRE ALARM <br />PANEL. <br />IN THE EVENT OF A POWER LOSS, ELECTRICALLY LOCKED DOORS IN A REQUIRED MEANS OF <br />EGRESS SHALL UNLOCK IN THE DIRECTION OF EGRESS WHERE REQUIRED BY OTHER LAWS, <br />CODES, AND GOVERNING STANDARDS, IN COMPLIANCE WITH NFPA 72 SECTION 21.10. <br />ACCESS CONTROL POWER SUPPLIES SHALL COMPLY WITH ACCESS CONTROL SYSTEM <br />(UL294), POWER SUPPLIES FOR FIRE PROTECTIVE SIGNALING SYSTEMS (UL1481) CALIFORNIA <br />STATE FIRE MARSHALL APPROVED AND NFPA 72 COMPLIANT. <br />ALL WIRING SHALL BE "POWER LIMITED" TYPE AND CONDUCTOR IS LISTED FOR SUCH USE. <br />COMPLY WITH CEC/NEC 725, 760 AND 800. <br />ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL PATHWAYS AND BACK BOXES FOR <br />DOORS, AND PATHWAYS BETWEEN THE ACCESS CONTROL PANELS AND ELECTRICAL FOR <br />POWER SUPPLIES, WHETHER SHOWN ON THE PLAN DRAWINGS OR NOT. E.C. SHALL PROVIDE <br />ALL REQUIRED 120VAC 20A CIRCUITS AND RECEPTACLES. <br />DOOR HARDWARE WITH WIRED INTEGRATED CARD / FOB READERS, DOOR POSITION SWITCH <br />AND REX SHALL BE FURNISHED, INSTALLED, AND PROGRAMMED BY THE SECURITY <br />CONTRACTOR, UNLESS OTHERWISE NOTED IN THE DIVISION 08 DOOR HARDWARE <br />SPECIFICATIONS AND THE DIVISION 28 ACCESS CONTROL SYSTEM SPECIFICATIONS. <br />SECURITY CONTRACTOR WILL WORK WITH CITY OF SANTA ANA ACCESS CONTROL <br />INTEGRATOR TO ACTIVATE THE NEW CONTROLLERS, CARD READERS, AND COMMISSION THE <br />OPERATIONS. <br />REFERENCE DIVISION 28 ACCESS CONTROL SYSTEM SPECIFICATIONS FOR ADDITIONAL <br />INFORMATION AND REQUIREMENTS. <br />THE SYSTEM DIAGRAM, PLAN DRAWINGS AND SPECIFICATIONS ARE GENERIC IN NATURE AND <br />PRESENTED IN A DESIGN-BUILD FORMAT FOR THE SECURITY CONTRACTOR TO FULLY <br />DESIGN, PROVIDE AND INSTALL A COMPLETE AND FULLY FUNCTIONAL SYSTEM. <br />SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ACCESS CONTROL SYSTEM <br />CONTROLLER BOARDS, BATTERIES, LOCKABLE ENCLOSURES AND POWER SUPPLIES IN MDF <br />AND IDF ROOMS. CONTRACTOR SHALL NOT INSTALL SUCH EQUIPMENT IN CLASSROOMS, <br />CUSTODIAN ROOMS, STORAGE ROOMS, ELECTRICAL ROOMS AND OFFICES UNLESS <br />SPECIFICALLY NOTED ON THE PLAN DRAWINGS. <br />SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESS CONTROL SYSTEM <br />COMPONENTS INCLUDING BUT NOT LIMITED TO AMAG M2150 CONTROLLERS, CARD <br />READERS, INTERFACE MODULES, POWER SUPPLIES, WALL MOUNTED LOCKABLE <br />ENCLOSURES, WIRING, SOFTWARE, LABOR, LICENSES, PROGRAMMING, FASTENERS, <br />LABELING, AND ALL OTHER COMPONENTS AND EQUIPMENT REQUIRED FOR A COMPLETE AND <br />FULLY FUNCTIONAL SYSTEM. INCLUDE ALL COSTS IN BASE BID. <br />ACCESS CONTROL SYSTEM BLOCK DIAGRAM KEY NOTES: <br />TYP <br />4D <br />4D FOUR (4) CATEGORY-6 UTP 4-PAIR CABLES <br />SCALE: N.T.S. <br />MPOE ROOM <br />OF <br />3 <br />1 <br />2 <br />4 TYP <br />TYP <br />TYP <br />TYP <br />6A10 11 <br />1 <br />2 <br />3 <br />4 <br />5 <br />8 <br />9 <br />10 <br />6 <br />6TYP <br />7 TYP <br />7 <br />9 <br />8 <br />11 <br />11 <br />IDF 108 <br />12 <br />12 <br />(E) (E) <br />(E) <br />(E) <br />SCALE: N.T.S. <br />4 <br />5 <br />TYP5 <br />TYP5 <br />13 13 <br />1 <br />2 <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />17. <br />18. <br />19. <br />LINE VOLTAGE 120VAC POWER RECEPTACLES EC EC <br />FIRE ALARM RELAY FOR FAIL-SAFE DOORS FC FC <br />CONDUIT / SLEEVES / BACKBOXES EC EC <br />MULLION MOUNTED CARD READERS AC AC <br />DOOR POSITION SENSORS / DOOR CONTACTS AC AC <br />ACCESS CONTROL SYSTEM WIRING AC AC <br />ELECTRIC HINGES HC HC <br />ELECTRIC POWER TRANSFER HINGES HC HC <br />PANIC HARDWARE W/ ELECTRIC LATCH RETRACTION HC HC <br />POWER SUPPLIES FOR PANIC HARDWARE W/ ELECTRIFIED LOCKSET HC AC/EC <br />ACCESS CONTROL LOCK POWER SUPPLIES AC AC/EC <br />PROXIMITY CREDENTIAL CARDS COSA COSA <br />ACS CONTROLLERS, READER BOARDS, I/O BOARDS & ENCLOSURES AC AC <br />ACCESS CONTROL POWER SUPPLIES AND ENCLOSURES AC AC/EC <br />WALL MOUNTED CARD READERS AC AC <br />ACCESS LEVEL PROGRAMMING COSA COSA <br />ACS ENTERPRISE SOFTWARE LICENSE COSA COSA <br />CARD USER DATABASE ENTRY COSA COSA <br />READER / DOOR PROGRAMMING COSA COSA <br />SCOPE OF WORK FURNISHED BY INSTALLED BY <br />ACCESS CONTROL SYSTEM (ACS) COSA COSA <br />ACCESS CONTROL CREDENTIALS COSA COSA <br />EC = ELECTRICL CONTRACTOR <br />HC = DOOR HARDWARE CONTRACTOR <br />SECURITY SYSTEMS SCOPE REPONSIBILITY CHART <br />LEGEND <br />A = ARCHITECT COSA = CITY OF SANTA ANA ACCESS INTEGRATOR <br />AC = SECURITY ACCESS CONTROL CONTRACTOR FC = FIRE ALARM CONTRACTOR <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />12" = 1'-0" <br />04/09/2025 <br />T52.3 <br />TECHNOLOGY <br />BLOCK <br />DIAGRAMS <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DESCRIPTION DATE <br />1 ASI #1 4/9/25 <br />1 <br />1 <br />1 <br />1