Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />PA <br />M <br />E <br />L <br />A <br /> <br />L <br />A <br />C <br />E <br />Y <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />32 <br />1 <br />7 <br /> SO <br />U <br />T <br />H <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />DATE:07/18/2025 <br />DRAWN BY <br />ESR <br />07/18/2025INITIAL DESIGN <br />POWER UP <br />SOLUTIONS LLC <br />C10 ELECTRICAL #1113778 <br />3855 ATHERTON RD, <br />ROCKLIN, CA 95765 <br />permit@gopowerupsolutions.com <br />08/21/2025CLIENT COMMENT A <br />09/08/2025CLIENT COMMENT B <br />WIRING <br />CALCULATIONS <br />PV-7 <br />PERCENT OF <br />VALUES <br />NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN EMT <br />.80 4-6 <br />.70 7-9 <br />.50 10-20 <br />AMBIENT TEMPERATURE SPECS <br />RECORD LOW TEMP 3° <br />AMBIENT TEMP (HIGH TEMP 2%)37° <br />MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/K <br />ELECTRICAL NOTES <br />1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2.ALL CONDUCTORS SHALL BE RATED UPTO 600V FOR RESIDENTIAL AND 1000V FOR COMMERCIAL AND 90 DEGREE C WET <br />ENVIRONMENT. <br />3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS <br />POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, <br />SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6.WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM <br />ACCORDINGLY. <br />7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE <br />GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE <br />SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. <br />MAX INPUT POWER 320W-540W <br />NOMINAL AC VOLTAGE RATING 240V/ 211-264V <br />MAX AC CURRENT 1.58A <br />MAX MODULES PER CIRCUIT 10 (SINGLE PHASE) <br />MAX OUTPUT POWER 380 VA <br />SOLAR MODULE SPECIFICATIONS <br /> IMP 10.77A <br /> VOC 45.30V <br /> ISC 11.14A <br /> TEMP. COEFF. VOC -0.27%/K <br /> MODULE DIMENSION 74.00"L x 41.1"W x 1.26"D (In Inch) <br />A <br />Signed 9/10/2025 <br />405W MODULE <br /> VMP 37.13V <br />HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ MANUFACTURER / MODEL #EB SH IQ8HC-72-M-DOM-US <br />MICRO INVERTERS <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL # <br />MIN/MAX DC VOLT RATING 22V MIN/ 58V MAX