Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />PA <br />M <br />E <br />L <br />A <br /> <br />L <br />A <br />C <br />E <br />Y <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />32 <br />1 <br />7 <br /> SO <br />U <br />T <br />H <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />DATE:07/18/2025 <br />DRAWN BY <br />ESR <br />07/18/2025INITIAL DESIGN <br />POWER UP <br />SOLUTIONS LLC <br />C10 ELECTRICAL #1113778 <br />3855 ATHERTON RD, <br />ROCKLIN, CA 95765 <br />permit@gopowerupsolutions.com <br />08/21/2025CLIENT COMMENT A <br />09/08/2025CLIENT COMMENT B <br />LABELS <br />PV-8 <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />EVERY 10' ON CONDUIT & ENCLOSURES <br />LABEL LOCATION: <br />EMT/CONDUIT RACEWAY <br />SOLADECK / JUNCTION BOX <br />CODE REF: 2022 CEC 690.31 (D)(2) <br />LABEL- 1: <br />TERMINALS ON THE LINE AND LOAD SIDES MAY <br />BE ENERGIZED IN THE OPEN POSITION <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />LABEL LOCATION: <br />AC DISCONNECT <br />INVERTER <br />MAIN SERVICE PANEL <br />SUBPANEL <br />MAIN SERVICE DISCONNECT <br />CODE REF: 2022CEC 690.13(B) <br />LABEL- 2: <br />!WARNING TRI POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />THIRD SOURCE IS ESS SYSTEM <br />LABEL LOCATION: <br />PRODUCTION METER <br />UTILITY METER <br />MAIN SERVICE PANEL <br />SUBPANEL <br />CODE REF: 2022 CEC 705.12(D)(3) & 2022 CEC 690.59 <br />LABEL- 3: <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />WARNING! <br />LABEL LOCATION: <br />MAIN SERVICE PANEL <br />SUBPANEL <br />MAIN SERVICE DISCONNECT <br />COMBINER <br />CODE REF: 2022 CEC 110.27(C) & OSHA 1910.145 (f) (7) <br />LABEL- 4: <br />LABEL LOCATION: <br />MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) <br />SUBPANEL (ONLY IF SOLAR IS BACK-FED) <br />CODE REF: 2022 CEC 705.12(B)(3)(2) <br />LABEL- 5: <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />LABEL LOCATION: <br />AC DISCONNECT <br />CODE REF: 2022 CFC 2022 1205.4.1(1) & 2022 CEC 690.56(C) <br />LABEL- 6: <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />LABEL LOCATION: <br />AC DISCONNECT <br />CODE REF: 2022 CEC 690.(C) (2) <br />LABEL- 7: <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT (ONLY IF MAIN <br />SERVICE DISCONNECT IS USED) <br />CODE REF: 2022 CEC 690.13(B) <br />LABEL- 8: <br />PCS CONTROLLED <br />CURRENT SETTING 160 A <br />THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM <br />TOWARDS THE MAIN PANEL IS CONTROLLED <br />ELECTRONICALLY. REFER TO THE MANUFACTURER'S <br />INSTRUCTION FOR MORE INFORMATION. <br />LABEL LOCATION: <br />MAIN SERVICE PANEL <br />CODE REF: 2022 CEC 705.13 <br />LABEL- 9: <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />LABEL LOCATION: <br />AROUND THE CT WIRE BY CLAMP <br />CODE REF: UL 1741, SECTION 206.3 <br />LABEL- 10: <br />A <br />Signed 9/10/2025 <br />PCS CONTROLLED <br />CURRENT SETTING 140 A <br />THE MAIN BREAKER HAS BEEN <br />DOWNSIZED <br />TO 175 AMPS, NO UPSIZING <br />LABEL LOCATION: <br />MAIN SERVICE PANEL <br />LABEL- 11: