PLAN OR DETAIL NUMBER <br />PLAN OR DETAIL NAME <br />PLAN OR DETAIL SCALE <br />DETAIL REFERRED TO BY SECTION CUT <br />SHEET DETAIL IS LOCATED <br />ON <br />NAME <br />1 VIEW NAME <br />1/8" = 1'-0" <br />1 <br />M101 <br />1 <br />4 <br />3 <br />2 <br />SIMSIM <br />INDICATES SIMILAR DETAIL REFERENCED <br />IN MULTIPLE LOCATIONS <br />LEVEL NAME <br />10'-0"HEIGHT ABOVE <br />PROJECT 0'-0" <br />1 INDICATES NOTE USED TO DESCRIBE <br />ADDITIONAL INFORMATION ABOUT <br />WORK REQUIRED, SPECIFIC TO THE <br />SHEET AND/OR DETAIL <br />NO R HT <br />INDICATES DIRECTION OF TRUE NORTH <br />VIEW KEY <br />LINE TYPE AND TAG KEY: <br />NEW WORK BY THIS CONTRACTOR (WIDE LINE) <br />NEW <br />EXISTING TO BE REMOVED (SHORT DASHED PATTERN) <br />EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE) <br />EXISTING <br />EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN) <br />HALFTONING DOES NOT MODIFY SCOPE. <br />'TAG'-(E)TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING <br />'TAG'-(R)TAGS WITH DASH 'R' INDICATES THE REFERENCED OBJECT IS EXISTING TO BE <br />REMOVED <br />TAG UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL <br />INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST <br />INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL <br />T101 <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />20" MAX. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />20"-25" MAX. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" MAX.10"-24" MAX. <br />ADA GUIDELINES -FRONT ACCESS <br />ADA STANDARDS FOR ACCESSIBLE DESIGN <br />INSTALL ABOVE COUNTER <br />DEVICE AT 44" ABOVE <br />FINISHED FLOOR. <br />INSTALL ABOVE COUNTER <br />DEVICE AT 40" ABOVE <br />FINISHED FLOOR. <br />INSTALL DEVICE AT 18" <br />ABOVE FINISHED FLOOR. <br />ADA GUIDELINES -SIDE ACCESS <br />INSTALL DEVICE AT 44" <br />ABOVE FINISHED FLOOR. <br />INSTALL DEVICE AT 42" <br />ABOVE FINISHED FLOOR. <br />BRANCH CIRCUITS: LIGHTING, RECEPTACLES, <br />CONTROLS, ETC. <br />CONTROLS (LIGHTING, POWER, BUILDING AUTOMATION, ETC.) <br />INTERIOR LOCATIONS WITH FINISHED CEILING AND WALLS: CONCEALED IN WALLS <br />AND ABOVE FINISHED CEILINGS <br />CONDUIT INSTALLATION SCHEDULE <br />THE FOLLOWING SCHEDULE SHALL BE ADHERED TO UNLESS THEY CONSTITUTE A VIOLATION OF APPLICABLE <br />CODES OR ARE NOTED OTHERWISE ON THE DRAWINGS. THE INSTALLATION OF RMC CONDUIT WILL BE <br />PERMITTED IN PLACE OF ALL CONDUIT SPECIFIED IN THIS SCHEDULE. REFER TO CONDUIT AND BOXES <br />SPECIFICATION 26 05 33 FOR ADDITIONAL INFORMATION. <br />REFER TO E6-00 FOR SPECIFIC PERMITTED HC RATED AC CABLE INSTALLATION. <br />INSTALLATION TYPE EMT <br />X <br />X <br />X <br />INTERIOR LOCATIONS WITHOUT FINISHED CEILINGS: CONCEALED IN WALL, <br />EXPOSED ABOVE CEILINGS <br />EXISTING INTERIOR LOCATIONS WITH FINISHED CEILINGS AND WALLS: CONCEALED <br />IN WALLS AND ABOVE FINISHED CEILINGS UNLESS OTHERWISE NOTED <br />X <br />X <br />HC RATED AC <br />X <br />X <br />MECHANICAL CONTRACTORM.C. <br />ELECTRICAL CONTRACTORE.C. <br />CONTRACTOR ABBREVIATION KEY <br />ABBR:DESCRIPTION: <br />SW-1P 26 09 33 SWITCH -SINGLE POLE <br />OC SW-OC-D OCCUPANCY SENSOR -DUAL TECHNOLOGYD26 09 33 <br />SW-D-LED DIMMER -LEDD26 09 33 <br />JB 26 05 33 JUNCTION BOX <br />J <br />J <br />ECONN 26 05 33 ELECTRICAL CONNECTION <br />E <br />E <br />PANEL '###'26 24 16 PANELBOARD -SURFACE MOUNT <br />MX-#/MS-# <br />/CB-#/CS-# <br />26 24 19 MANUAL SWITCH / STARTER / COMBINATION <br />STARTER/ CIRCUIT BREAKER. REFER TO <br />DISC/STA SCHEDULE <br />ELECTRICAL SYMBOL LIST <br />SYMBOL:TAG:SPEC <br />SECTION:DESCRIPTION: <br />SW-OD DIMMER -WALL DIMMER <br />OCCUPANCY SENSORO26 09 33 <br />LINEAR LUMINAIRES <br />TROFFER <br />DOWNLIGHT LUMINAIRE <br />SINGLE FACE EXIT SIGN <br />DOUBLE FACE EXIT SIGN <br />REC-DUP 26 27 26 DUPLEX RECEPTACLE, 125V <br />REC-DUP-GFI 26 27 26 DUPLEX GFI RECEPTACLE, 125V <br />REC-QUAD 26 27 26 QUAD RECEPTACLE, 125V <br />REC-QUAD-GFI 26 27 26 QUAD GFI RECEPTACLE, 125V <br />REFER TO LUMINAIRE <br />SCHEDULE <br />S PAGING SPEAKER, CEILING MOUNT <br />D NURSE CALL DOME LIGHT, WALL MOUNT <br />N NURSE CALL STATION -WALL MOUNT <br />D NURSE CALL DOME LIGHT, CEILING MOUNT <br />RI <br />RI / CR <br />PAGING SYSTEM VOLUME CONTROL -WALL <br />MOUNT <br />REQUEST TO EXIT DEVICE -CEILING MOUNT <br />TECHNOLOGY SYSTEM ROUGH-IN <br />TECHNOLOGY SYSTEM ROUGH-IN; CARD <br />READER <br />SW-OC-P-O SWITCH -OCCUPANCY SENSOR <br />WALL SWITCHO26 09 33 <br />NT NURSE CALL PULL CORD STATION <br />WIRELESS ACCESS POINTWAP <br />X <br />NURSE CALL ANNUNCIATOR / MASTER -WALL <br />MOUNT <br />NCM <br />CCTV CAMERA -CEILING MOUNT <br />RI-TECH 26 05 33 <br />RI-TECH-CR 26 05 33 <br />V <br />PANEL '###'26 24 16 PANELBOARD -RECESSED MOUNT <br />SW-D-LED DIMMER -LED -3-WAY326 09 33 <br />OC SW-OC-D OCCUPANCY SENSOR -DUAL TECHNOLOGY - <br />2-POLED/ab 26 09 33 <br />TR #26 24 19 TRANSFORMER <br />ELECTRICAL ABBREVIATION KEY <br />AFF ABOVE FINISHED FLOOR <br />NIC NOT IN CONTRACT <br />ABBR:DESCRIPTION: <br />TYP TYPICAL <br />C CONDUIT <br />UON UNLESS OTHERWISE NOTED <br />GFI GROUND FAULT INTERRUPTER <br />NORMAL BRANCH LUMINAIRE <br />EMERGENCY LUMINAIRE <br />LUMINAIRE SYMBOL KEY <br />SYMBOL:DESCRIPTION: <br />1. THE ELECTRICAL LIGHTING DRAWINGS INDICATE EXISTING ELECTRICAL ITEMS TO BE <br />REMOVED. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED <br />AND DO NOT INDICATE EVERY BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED. THE <br />CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING <br />CONDITIONS. <br />2. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A <br />JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT <br />AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT. <br />3. BALLASTS MANUFACTURED PRIOR TO 1980 CONTAIN PCBs AND SHALL BE DISPOSED OF BY <br />A FEDERAL OR STATE E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH <br />SPECIFICATIONS. <br />4. HID AND FLUORESCENT LAMPS CONTAIN MERCURY AND SHALL BE DISPOSED OF BY A <br />FEDERAL OR STATE E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH <br />SPECIFICATIONS. <br />5. REUSE EXISTING CONDUIT, CIRCUITS AND LIGHTING CONTROL WHERE POSSIBLE. PROVIDE <br />NEW CONDUIT AND WIRE WHERE SHOWN, MISSING OR REQUIRED TO INSTALL THE NEW <br />LIGHT FIXTURES. <br />6. VERIFY MANUFACTURERS INSTALLATION GUIDELINES WITH EXISTING FIELD CONDITIONS <br />PRIOR TO BIDDING AND ORDERING NEW LIGHT FIXTURES AND INSTALLATION MATERIAL. <br />7. MATCH EXISTING PAINTED SURFACES. WHERE REPLACED LUMINAIRE DOES NOT FULLY <br />COVER EXISTING JUNCTION BOX OR PAINTED SURFACE. PROVIDE CUSTOM BACK PLATE <br />WHERE NECESSARY TO COVER ANY FIELD CONDITIONS THAT WOULD ALLOW INTRUSION <br />OF WATER AND CAULK WHERE NECESSARY. <br />ELECTRICAL LIGHTING DEMOLITION NOTES: <br />1. ALL LUMINAIRES SHOWN TO BE DEMOLISHED SHALL BE DISPOSED OF IF NOT REQUIRED BY <br />OWNER FOR ATTIC STOCK. CONFIRM WITH OWNER PRIOR TO DISPOSAL IF THE LAMPS, <br />LENS OR SUBSET OF LUMINAIRES SHOULD BE TURNED OVER FOR ATTIC STOCK. <br />2. REMOVE EXISTING LUMINAIRES AND WALL SWITCHES WHERE SHOWN. LOCATE AND <br />IDENTIFY ELECTRICAL CIRCUIT SERVING REMOVED LUMINAIRES FOR REUSE WITH NEW <br />DEVICES. <br />3. WHERE WALL SWITCH DEVICE IS REMOVED AND NOT REPLACED. PROVIDE WITH BLANK <br />SWITCH PLATE. <br />4. PROVIDE (1) UNSWITCHED LEG FROM PANEL SERVING THE EMERGENCY FIXTURES TO THE <br />SENSOR LEG SERVING THE NEW BATTERY BACK UP IN NEW LUMINAIRES. <br />5. CONNECT NEW LUMINAIRES TO CIRCUIT THAT SERVED PREVIOUSLY REMOVED LUMINAIRE <br />USING 2#12 &1#12 GND IN 3/4" C. EXTEND CONDUIT AND CONDUCTORS AS REQUIRED TO <br />MAKE CONNECTION. CONDUIT IN GOOD CONDITION SHALL BE REUSED IN PLACE. <br />6. NEW OCCUPANCY SENSORS TO BE INSTALLED IN A MANUAL ON/AUTO OFF' <br />CONFIGURATION. <br />7. COORDINATE LOCATIONS OF NEW LUMINAIRES WITH EXISTING DUCT, PIPING, STRUCTURAL <br />AND CEILING MOUNTED DEVICES. <br />ELECTRICAL LIGHTING REMODEL NOTES: <br />2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1 <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />CALIFORNIA CODE OF REGULATIONS (CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, <br />PART 2) TITLE 24, PART 2 <br />( 2021 INTERNATIONAL BUILDING CODE (IBC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 <br />( 2020 NATIONAL ELECTRICAL CODE (NEC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ENERGY CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 <br />2022 CALIFORNIA FIRE CODE (CFC) <br />CALIFORNIA CODES OF REGULATIONS (CRR) TITLE 24, PART 9 <br />( 2021 INTERNATIONAL FIRE CODE (IFC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA EXISTING BUILDING CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 10 <br />( 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)) <br />2022 CALIFORNIA REFERENCES STANDARDS CODE <br />CALIFORNIA DOE OF REGULATIONS (CCR) TITLE 24, PART 12 <br />AMERICANS WITH DISABILITIES ACT (ADA) <br />TITLE II -ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (ADAG) <br />1990 STATE FIRE MARSHAL REGULATIONS AND AMENDMENTS TO-DATE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, CALIFORNIA STATE <br />ACCESSIBILITY STANDARDS <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 19 <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />(CAL GREEN), PART II, TITLE 24 C.C.R <br />NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE [2016] EDITION <br />(CA AMENDED) <br />APPLICABLE CODES AND STANDARDS: <br />ELECTRICAL GENERAL NOTES: <br />LUMINAIRE <br />F1 = FIXTURE TAG <br />X-1 = PANEL AND CIRCUIT NUMBER <br />a = SWITH DESIGNATION <br />*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS <br />INFORMATION. EX: F1/X-1/a <br />DEVICE X-1 = PANEL AND CIRCUIT NUMBER. <br />*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS <br />INFORMATION. EX: X-1 / 1 <br />LUMINAIRE KEY: <br />DEVICE KEY: <br />ELECTRICAL RENOVATION NOTES: <br />1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD <br />SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND <br />REPORT ANY CONFLICTS BEFORE PROCEEDING. <br />2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. VERIFY EXISTING <br />CONDITIONS AND REPORT ANY CONFLICTS WITH NEW WORK BEFORE STARTING WORK. <br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED <br />TO, LIGHTING, POWER, AND SYSTEMS. <br />ELECTRICAL PHASING NOTES: <br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED <br />TO, LIGHTING, POWER, AND SYSTEMS. <br />1. REFER TO ARCHITECTURAL DRAWINGS FOR GENERAL DESCRIPTION OF PHASES. <br />ELECTRICAL DRAWINGS DEPICT THE INTENT OF THE FINAL DESIGN. THE ELECTRICAL <br />DRAWINGS DO NOT DEPICT THE MEANS AND METHODS TO MEET THE REQUIREMENTS OF <br />THE PHASING CRITERIA. <br />2. REVIEW PROJECT PHASING PLANS TO COORDINATE DEMOLITION WORK, OUTAGES, ETC. <br />WITH AFFECTED ADJACENT AREAS. <br />3. PROVIDE TEMPORARY LIGHTING, POWER, SYSTEMS, ETC. AS NEEDED TO MAINTAIN <br />SERVICE TO ALL AREAS DURING ALL PHASES OF PROJECT. <br />4. INSTALL TEMPORARY LIGHTING, CIRCUITS, ETC. AS NECESSARY TO KEEP ALL OCCUPIED <br />SPACES OPERATIONAL THROUGHOUT ALL PHASES OF THE PROJECT <br />5. PHASE DEMOLITION WORK TO MINIMIZE DOWNTIME. <br />ELECTRICAL INSTALLATION NOTES: <br />1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR <br />ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS ON <br />THIS PAGE FOR ADDITIONAL INFORMATION. <br />2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE <br />WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR <br />BRANCH CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN EACH <br />PHASE. <br />3. EMERGENCY BRANCH WIRING FOR FEEDERS AND BRANCH CIRCUITS SHALL BE ROUTED IN <br />SEPARATE RACEWAY, JUNCTION BOXES, PULL BOXES, AND CABINETS. WIRING FOR EACH <br />BRANCH SHALL BE INDEPENDENT FROM OTHER BRANCHES, INCLUDING THE NORMAL <br />BRANCH. <br />4. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT +42" FROM FLOOR (CENTERLINE <br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. DEVICES MAY BE SURFACE MOUNTED <br />WHEN CONDUIT IS SPECIFIED EXPOSED. <br />5. FLUSH MOUNT ALL DUPLEX RECEPTACLES AND TECHNOLOGY OUTLETS AT +18" FROM <br />FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND <br />OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED.MOUNT <br />EXTERIOR LOCATED RECEPTACLES WITH WHILE-IN-USE COVERS AT +20" FROM FINISHED <br />GRADE (CENTER DIMENSIONS) TO MAINTAIN INSTALLATION ADA COMPLIANCE. <br />6. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL <br />BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF <br />THROUGH-PENETRATION FIRESTOPS. REFER TO 03/A5-01 FOR ADDITIONAL INFORMATION <br />AND REQUIREMENTS SPECIFIC TO FIRESTOPPING. <br />7. CONNECTION FOR ELECTRIC WATER COOLERS (EWC) SHALL BE A JUNCTION BOX <br />CONCEALED BEHIND WATER COOLER ACCESS PLATE OR BE A GFI RECEPTACLE LOCATED <br />DIRECTLY BELOW AND CENTERED ON EWC. CONTRACTOR SHALL VERIFY TYPE OF EWC TO <br />BE INSTALLED. <br />8. MOUNT ALL FIRE ALARM PULL STATIONS AT +42" FROM FLOOR (CENTERLINE DIMENSION) <br />EXCEPT WHERE OTHERWISE NOTED. <br />9. INSTALL ALL WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES AT 90" ABOVE FINISHED <br />FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER, EXCEPT WHERE OTHERWISE <br />NOTED. HEIGHT SHALL BE MEASURED TO THE TOP OF THE DEVICE. <br />10. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND <br />EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES <br />IN CEILING TILE PATTERN. SMOKE DETECTORS AND OCCUPANCY/VACANCY SENSORS SHALL <br />BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN GRILLE. <br />11. CONTRACTOR SHALL VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT <br />LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. <br />PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL <br />ADJUST RECEPTACLES, OUTLETS, OR CONNECTION LOCATIONS TO ACCOMMODATE <br />FURNITURE AND/OR EQUIPMENT. <br />12. ELECTRICAL AND TECHNOLOGY EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, <br />OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL <br />MOUNTING OF ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT <br />SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE OTHER <br />CONTRACTOR. <br />13. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL <br />OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE <br />EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR <br />SEALED INTO OPENINGS. <br />14. ALL WELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS. <br />CONTRACTOR SHALL FURNISH TO THE ARCHITECT/ENGINEER CERTIFICATES QUALIFYING <br />EACH WELDER, PRIOR TO START OF WORK. THE ARCHITECT/ENGINEER RESERVES THE <br />RIGHT TO REQUIRE QUALIFYING DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF <br />ANY WELDERS ASSIGNED TO THE JOB. <br />15. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE <br />WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE <br />IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND <br />FINISH. <br />16. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY <br />AUDIO/VISUAL, AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING <br />MOUNTED DEVICES, OTHER THAN SPRINKLERS. <br />17. ELECTRICAL IDENTIFICATION. REFER TO SPECIFICATION SECTION 26 05 53 FOR <br />COLOR/LABEL REQUIREMENTS FOR CONDUIT, BOX, CABLE/W IRE, AND EQUIPMENT. <br />1. THE DEVICES SHOWN ON THE DRAWINGS CONSIDERED AS GENERAL COORDINATION <br />PURPOSE ONLY. <br />2. THE FIRE ALARM SYSTEM DRAWINGS SHALL BE PROVIDED BY THE FIRE ALARM <br />CONTRACTOR UNDER A DEFERRED APPROVAL PROCESS. <br />3. FIRE ALARM SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY OF SANTA ANA AND THE <br />EEOR FOR APPROVAL WITHIN 14 CALENDAR DAYS AFTER NOTICE TO PROCEED. THE FIRE <br />ALARM SHOP DRAWINGS SHALL CONTAIN THE FOLLOWING REQUIREMENTS <br />4. THE WORK SHALL NOT BE STARTED UNTIL THE DETAILED DRAWINGS, SPECIFICATIONS AND <br />ENGINEERING CALCULATIONS HAVE BEEN ACCEPTED AND APPROVED BY THE CITY OF <br />SANTA ANA AND THE EEOR. CONTRACTOR SHALL PROVIDE APPROVED COPY TO THE OWNER <br />REPRESENTATIVE. <br />FIRE ALARM DEFERRED APPROVAL NOTES: <br />a. INDICATE WHAT TYPE OF SYSTEM IS BEING PROVIDED. PROVIDE CATALOG DATA, <br />CSFM LISTING NUMBER AND MODEL NUMBER FOR EVERY FIRE ALARM SYSTEM <br />COMPONENT. <br />b. PROVIDE SINGLE LINE, RISER AND POINT-TO POINT WIRING DIAGRAMS. <br />c. AN EMERGENCY WARNING SYSTEM WITH VIRTUAL STROBE DEVICES IS REQUIRED <br />FOR THE HEARING IMPAIRED. <br />d. INDICATE THE CONDUIT SIZES, QUANTITY AND TYPE CONDUCTORS AND <br />WHETHER THE SYSTEM IS POWER LIMITED OR NON-POWER LIMITED. <br />e. PROVIDE BATTERY CALCULATIONS FOR THE ENTIRE SYSTEM (24 HOUR STANDBY, <br />5 MINUTE ALARM). <br />f. PROVIDE FLOOR PLANS SHOWING LOCATIONS OF ALL FIRE ALARM EQUIPMENT. <br />INTERCONNECT WIRING, REMOTE POWER SUPPLIERS AND ANNUNCIATOR. <br />g. INDICATE WHETHER THE SYSTEM IS INDEPENDENT OR INTERCONNECTED TO THE <br />EXISTING FIRE ALARM SYSTEM. <br />h. PROVIDE VOLTAGE DROP CALCULATIONS FOR THE LONGEST RUN AND THE <br />CIRCUITS WITH THE LARGEST LOAD REQUIRED FOR BOTH INITIATION AND SIGNAL <br />CIRCUITS. <br />ELECTRICAL SYMBOL LIST <br />SYMBOL:DESCRIPTION: <br />S #FIRE ALARM SMOKE DETECTOR, CEILING MOUNT <br />BLANK -PHOTOELECTRIC <br />FIRE ALARM MANUAL PULL STATIONF <br />FIRE ALARM VISUAL ALARM DEVICE, CEILING OR WALL MOUNT <br />CD = CANDELA RATING SELECTED BY NICET DESIGNER <br />FF COMBINATION AUDIO HORN AND VISUAL ALARM DEVICE WALL MOUNTED <br />CD = CANDELA RATING SELECTED BY NICET DESIGNER <br />FIRE ALARM REMOTE INDICATORRI <br />TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, <br />TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND SHALL <br />NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. <br />©2022 IMEG CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />The FUTURE. Built Smarter www.imegcorp.com <br />R <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO:FLOOR LEV:SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. 5th St Suite 2950 | Los Angeles, CA 90013 USA <br />Phone 310.820.4600 | Fax 310.207.4215 <br />www.huitt-zollars.com <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION <br />HOSPITALS NATIONAL <br />FACILITIES SERVICES 1800 <br />HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO.ISSUED DATE <br />0 <br />5' <br />50 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br />1/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />222 S. HARBOR BOULEVARD, SUITE 800 I ANAHEIM, CA 92805 <br />PH: 714.490.5555 I FAX: 714.490.5560 <br />IMEG PROJ. NO.: 22008618.00 <br />PROJECT #22008618.00 <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />E0-01 <br />ELECTRICAL COVERSHEET <br />CA394-1 <br />CAP0227721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />REFER TO SPECIFICATION SECTIONS LED LIGHTING 26 51 19 FOR ADDITIONAL INFORMATION AND REQUIREMENTS. <br />INTERIOR CORRELATED COLOR TEMPERATURE 3500K, COLOR RENDERING INDEX (CRI) AT OR ABOVE 80, UNLESS NOTED OTHERWISE. <br />CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION AND THE <br />SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE FIRST MANUFACTURER LISTED IS THE BASIS <br />OF DESIGN. <br />VERIFY AND COORDINATE ALL CEILING TYPES WITH LUMINAIRE MOUNTING AND TRIM REQUIREMENTS PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER. <br />CONFIRM ALL COLORS AND FINISHES OF ALL LUMINAIRE COMPONENTS WITH ARCHITECT AND INTERIOR DESIGNER PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER. <br />UNLESS INDICATED ON LIGHTING PLANS OR BELOW, REFER TO ARCHITECTURAL AND INTERIOR DESIGN ELEVATIONS, SECTIONS AND DETAILS FOR ALL SUSPENDED AND WALL MOUNTED LUMINAIRE <br />MOUNTING HEIGHTS. <br />UC - UNDER CABINET <br />RE - RECESSED O - OTHER (SEE DESCRIPTION) <br />0-10V - 0-10V DIMMING CL - CEILING SURFACE K - KSH12 .125" ACRYLIC LED - LIGHT EMITTING DIODE FIX - FIXTURE, FT - FOOT, LAMP <br />(TYPE) DRIVER: (MTG) MOUNTING: (L/L) LENS/LOUVER: (WATT) PER: (TYPE) LED <br />LED LUMINAIRE SCHEDULE <br />ITEM DESCRIPTION L/L MTG <br />DIMENSIONS WATT LED DRIVER <br />MANUFACTURER AND MODELL W H DIA. <br />ANSI <br />WATTS PER TYPE <br />DELIVERED <br />LUMENS <br />(MIN)VOLTS TYPE <br />A 2X4 CENTER BASKET, INDIRECT-DIRECT <br />TROFFER, HIGH PERFORMANCE DIFFUSER. <br />O RE 4'-0" 2'-0" 4 1/2" 57 W FIX LED 7200 LM 277 V 0-10 V MARK LIGHTING; <br />WHSR-2X4-90CRI-35K-7200LM-MIN <br />10-MVOLT-SWC-E10WLCP (where <br />shown) <br />A1 2X4 CENTER BASKET, INDIRECT-DIRECT <br />TROFFER, HIGH PERFORMANCE DIFFUSER. <br />O RE 4'-0" 2'-0" 4 1/2" 37 W FIX LED 4800 LM 277 V 0-10 V MARK LIGHTING; <br />WHSPR-2x4-90CRI-35K-4800LM-MI <br />N10-MVOLT-SWC-ZT <br />A1E 2X4 CENTER BASKET, INDIRECT-DIRECT <br />TROFFER, HIGH PERFORMANCE DIFFUSER. <br />PROVIDED WITH 90-MIN BATTERY PACK. <br />O RE 4'-0" 2'-0" 4 1/2" 37 W FIX LED 4800 LM 277 V 0-10 V MARK LIGHTING; <br />WHSPR-2x4-90CRI-35K-4800LM-MI <br />N10-MVOLT-SWC-E10WLCP-ZT <br />A2 2X4 TROFFER K RE 4'-0" 2'-0" 3 1/4" 29 W FIX LED 3922 LM 277 V 0-10 V LITHONIA LIGHTING <br />2GTL-4-40L-A12125-EZ1-LP835 <br />A3 2X4 TROFFER K RE 4'-0" 2'-0" 3 1/4" 35 W FIX LED 4777 LM 277 V 0-10 V LITHONIA LIGHTING <br />2GTL-4-48L-A12125-EZ1-LP835 <br />B OPEN DOWNLIGHT O RE 7 1/2" 6" 10 W FIX LED 1000 LM 277 V 0-10V GOTHAM LIGHTING <br />EVO6-35/10-AR-LSS-MD-MVOLT-EZ <br />10 <br />D ARCHITECTURAL LINEAR INDIRECT O WL 6'-0" 1 1/2" 2 5/16"32 W FIX LED 5190 LM 277 V 0-10 V MARK LIGHTING; <br />S1LWI-LLP-6FT-MSL6-I90CRI-I35K-1 <br />800LMF-MIN1-TGLD-MVOLT-WHTT- <br />ZT <br />EX SINGLE FACE EXIT SIGN - CEILING MOUNTE <br />GREEN LETTERS PROVIDED WITH 90-MIN <br />BATTERY PACK <br />O CL 1'-1" 1'-0 <br />3/4" <br />9 7/16" 4 W FIX LED 277 V LITHONIA LIGHTING <br />LE-S-1-G-ELN <br />NOTES: <br />1. {L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE. <br />2. [#B] PUSH BUTTON REFERS TO SCENE QUANTITY. CONTROL STATION SHALL BE CAPABLE OF [RAISE/LOWER AND] <br />SWITCHING ON/OFF FOR MULTIPLE SCENES AS INDICATED ON SHEETS AND THE LIGHTING SEQUENCE OF OPERATIONS {L##}. <br />COORDINATE QUANTITIES OF BUTTONS FOR CONTROL STATIONS WITH LIGHTING CONTROL MANUFACTURER. <br />3. [Z#] DENOTES LIGHTING CONTROL ZONE. PROVIDE SEPARATE CONTROL OF EACH CONTROLLED ZONE. LUMINAIRES <br />ASSOCIATED WITH THE SAME ZONE SHALL OPERATE TOGETHER WITHIN THE SAME PROGRAMMED SCENE. <br />4. a = SWITCH DESIGNATION FOR LIGHTING CONTROL <br />5. VERIFY AND COORDINATE ALL TIME CLOCK SETTINGS WITH OWNER PRIOR TO FINAL PROGRAMMING. <br />6. VERIFY AND COORDINATE ALL PUSH BUTTON WALL DEVICES AND QUANTITIES OF INDIVIDUAL BUTTONS WITH SCENES AND <br />ZONES PER LOCATION. <br />7. VERIFY AND COORDINATE ALL PUSH BUTTON QUANTITIES AND SCENE NAMES WITH OWNER PRIOR TO SUBMITTING <br />ENGRAVING TEMPLATE TO MANUFACTURER. <br />LIGHTING SEQUENCE OF OPERATION <br />PLAN ID LIGHTING SWITCHED <br />{LD1} Sequence: Lighting control provides occupancy control and manual dimming control in this space. <br />ON: <br />Lights turn on via occupancy sensor. <br />ADJUST: <br />Lights are raised / lowered using a wall control to 10-100% output. <br />OFF: <br />Lights turn off using a wall controller. <br />Lights automatically turn off via occupancy sensor after the space has been vacant for 15 minutes. <br />{LD2} Sequence: Lighting control provides occupancy control and manual dimmning control n this space. <br />ON: <br />Type 'D' light turns on via occupancy sensor to 100% maximum output, upon occupancy. <br />Type 'A' light turns on manually by staff. <br />ADJUST: <br />Lights are raised / lowered via wall control. <br />OFF: <br />Both lights turn off using the wall controller(s). After the space has been vacant for 15 minutes, Both lights will <br />automatically turn off. <br />{LD3} Sequence: Lighting control provides occupancy control and manual 3-way dimming control in this space. <br />ON: <br />Lights turn on using a wall control or via occupancy sensor. <br />OFF: <br />The lights turn off using the wall controller. <br />The lights are automatically turn off via occupancy sensor after the sapce has been vacant for 15 minutes. <br />{LS1} Sequence: Lighting control provides vacancy control and manual switching control in this space. <br />ON: <br />Lights turn via vacancy sensor. <br />ADJUST: <br />None. <br />OFF: <br />The lights turn off using the wall controller. <br />The lights are automatically turn off via vacancy sensor after the sapce has been vacant for 15 minutes. <br />CITY SUBMITTAL 11/03/2025 <br /> UNV <br /> UNV <br /> UNV <br /> UNV <br /> UNV <br /> UNV <br /> UNV <br /> UNV <br />1 CITY BACKCHECK #1 01/06/2026 <br />101125520, 20187249, 40140902